898 resultados para Maes, Nicolaes, 1632-1693.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The behavior of two cationic copper complexes of acetylacetonate and 2,2'-bipyridine or 1,10-phenanthroline, [Cu(acac)(bipy)]Cl (1) and [Cu(acac)(phen)]Cl (2), in organic solvents and ionic liquids, was studied by spectroscopic and electrochemical techniques. Both complexes showed solvatochromism in ionic liquids although no correlation with solvent parameters could be obtained. By EPR spectroscopy rhombic spectra with well-resolved superhyperfine structure were obtained in most ionic liquids. The spin Hamiltonian parameters suggest a square pyramidal geometry with coordination of the ionic liquid anion. The redox properties of the complexes were investigated by cyclic voltammetry at a Pt electrode (d = 1 mm) in bmimBF(4) and bmimNTf(2) ionic liquids. Both complexes 1 and 2 are electrochemically reduced in these ionic media at more negative potentials than when using organic solvents. This is in agreement with the EPR characterization, which shows lower A(z) and higher g(z) values for the complexes dissolved in ionic liquids, than in organic solvents, due to higher electron density at the copper center. The anion basicity order obtained by EPR is NTf2-, N(CN)(2)(-), MeSO4- and Me2PO4-, which agrees with previous determinations. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Crossed classification models are applied in many investigations taking in consideration the existence of interaction between all factors or, in alternative, excluding all interactions, and in this case only the effects and the error term are considered. In this work we use commutative Jordan algebras in the study of the algebraic structure of these designs and we use them to obtain similar designs where only some of the interactions are considered. We finish presenting the expressions of the variance componentes estimators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The benzoyl hydrazone based dimeric dicopper(II) complex [Cu2(R)(CH3O)(NO3)]2(CH3O)2 (R-Cu2+), recently reported by us, catalyzes the aerobic oxidation of catechols (catechol (S1), 3,5- itertiarybutylcatechol (S2) and 3-nitrocatechol (S3)) to the corresponding quinones (catecholase like activity), as shown by UV–Vis absorption spectroscopy in methanol/HEPES buffer (pH 8.2) medium at 25 C. The highest activity is observed for the substituted catechol (S2) with the electron donor tertiary butyl group, resulting in a turnover frequency (TOF) value of 1.13 103 h1. The complex R-Cu2+ also exhibits a good catalytic activity in the oxidation (without added solvent) of 1-phenylethanol to acetophenone by But OOH under low power (10 W) microwave (MW) irradiation. 2014 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: A prática médica actual tem a crescente preocupação de avaliar e melhorar a qualidade dos serviços médicos prestados aos seus doentes. O objectivo principal deste trabalho foi analisar a morbilidade/mortalidade das cirurgias realizadas no Serviço de Ginecologia da Maternidade Dr. Alfredo da Costa, e possíveis factores associados ao aparecimento de complicações pós-operatórias. Material e Métodos: Foi feito um estudo retrospectivo de todas as cirurgias realizadas no ano de 2001, tendo sido analisadas múltiplas variáveis, como a idade, patologias anteriores, dias de internamento, tipo de anestesia, tempo cirúrgico, tipo de cirurgia e respectiva via de abordagem, “graduação” do cirurgião, uso de antibioterapia e complicações intra e pós-operatórias. Resultados: Dos 561 doentes, 1% tiveram complicações intra-operatórias e 8.9% tiveram complicações pós-operatórias. Dentro destas últimas, as “urinárias” foram as mais frequentes, seguidas pelas complicações da ferida operatória. Não se encontrou qualquer associação estatisticamente significativa entre estas complicações e a presença de patologias anteriores ou mesmo pelo tipo de cirurgia, anestesia realizada ou “graduação” do cirurgião. A via laparoscópica, o uso de antibioterapia intra-operatoriamente e uma duração da cirurgia inferior a 60 minutos esteve associado a menos complicações. Conclusões: Confirma-se mais uma vez a importância de um menor tempo cirúrgico e do uso de antibioterapia profiláctica na redução da morbilidade operatória, assim como a utilização da via laparoscópica, para redução de complicações.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Gelastic seizures are a frequent and well established manifestation of the epilepsy associated with hypothalamic hamartomas. The scalp EEG recordings very seldom demonstrate clear spike activity and the information about the ictal epilepsy dynamics is limited. In this work, we try to isolate epileptic rhythms in gelastic seizures and study their generators. Methods: We extracted rhythmic activity from EEG scalp recordings of gelastic seizures using decomposition in independent components (ICA) in three patients, two with hypothalamic hamartomas and one with no hypothalamic lesion. Time analysis of these rhythms and inverse source analysis was done to recover their foci of origin and temporal dynamics. Results: In the two patients with hypothalamic hamartomas consistent ictal delta (2–3 Hz) rhythms were present, with subcortical generators in both and a superficial one in a single patient. The latter pattern was observed in the patient with no hypothalamic hamartoma visible in MRI. The deep generators activated earlier than the superficial ones, suggesting a consistent sub-cortical origin of the rhythmical activity. Conclusions: Our data is compatible with early and brief epileptic generators in deep sub-cortical regions and more superficial ones activating later. Significance: Gelastic seizures express rhythms on scalp EEG compatible with epileptic activity originating in sub-cortical generators and secondarily involving cortical ones.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El treball ofereix una visió de conjunt de la recerca duta a terme a Espanya en determinació d’estructures cristal•lines, des dels seus inicis fins 1955, data en la què assoliren un cert grau de consolidació. La perspectiva historiogràfica seguida pretén establir un equilibri entre el tractament de les qüestions tècniques i les relatives a l’organització dels diferents equips de recerca, sense oblidar el context econòmic i polític en que van tenir lloc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.