867 resultados para MINIMALLY INVASIVE NEUROSURGERY
Resumo:
Vertebroplasty is a minimally invasive surgical procedure, which requires efficacious percutaneous cement delivery via a cannulated needle to restore the strength and stiffness in osteoporotic vertebral bodies. Cement viscosity is understood to influence the injectability, cohesion and cement retention within the vertebral body. Altering the liquid to powder ratio modifies the viscosity of bone cement; however, the cement viscosity-response association between cement fill and augmentation of strength and stiffness is unknown. The aim of this study was to determine the relationship between viscosity, cement fill and the potential augmentation of strength and stiffness in an open pore foam structure that was representative of osteoporotic cancellous bone using an in vitro prophylactic vertebroplasty model. The results showed a strong linear correlation between compressive strength and stiffness augmentation with percentage cement fill, the extent of which was strongly dependent on the cement viscosity. Significant forces were required to ensure maximum delivery of the high viscosity cement using a proprietary screw-driven cement delivery technology. These forces could potentially exceed the normal human physical limit. Similar trends were observed when comparing the results from this study and previously reported cadaveric and animal based in vitro models.
Resumo:
The formidable barrier properties of the uppermost layer of the skin, the stratum corneum, impose significant limitations for successful systemic delivery of broad range of therapeutic molecules particularly macromolecules and genetic material. Microneedle (MN) has been proposed as a strategy to breach the stratum corneum barrier function in order to facilitate effective transport of molecules across the skin. This strategy involves use of micron sized needles fabricated of different materials and geometries to create transient aqueous conduits across the skin. MN, alone or with other enhancing strategies, has been demonstrated to dramatically enhance the skin permeability of numerous therapeutic molecules including biopharmaceuticals either in vitro, ex vivo or in vivo experiments. This suggested the promising use of MN technology for various possible clinical applications such as insulin delivery, transcutaneous immunisations and cutaneous gene delivery. MN has been proved as minimally invasive and painless in human subjects. This review article focuses on recent and future developments for MN technology including the latest type of MN design, challenges and strategies in MNs development as well as potential safety aspects based on comprehensive literature review pertaining to MN studies to date. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
Background Sentinel lymph node biopsy is a recently developed, minimally invasive technique for staging the axilla in patients with breast cancer. It has been suggested that this technique will avoid the morbidity associated with more extensive axillary dissection. A wide range of different methods and materials has been employed for lymphatic mapping, but there has been little consensus on the most reliable and reproducible technique.
Methods This is a comprehensive review of all published literature on sentinel node biopsy in breast cancer, using the Medline and Embase databases and cross-referencing of major articles on the subject.
Results and conclusion Sentinel node biopsy is a valid technique in breast cancer management, providing valuable axillary staging information. The optimal technique of lymphatic mapping utilizes a combination of vital blue dye and radiolabelled colloid. However, there remain controversial issues which require to be resolved before sentinel node biopsy becomes a widely accepted part of breast cancer care.
Resumo:
Objective: Development and validation of a selective and sensitive LCMS method for the determination of methotrexate polyglutamates in dried blood spots (DBS).
Methods: DBS samples [spiked or patient samples] were prepared by applying blood to Guthrie cards which was then dried at room temperature. The method utilised 6-mm disks punched from the DBS samples (equivalent to approximately 12 μl of whole blood). The simple treatment procedure was based on protein precipitation using perchloric acid followed by solid phase extraction using MAX cartridges. The extracted sample was chromatographed using a reversed phase system involving an Atlantis T3-C18 column (3 μm, 2.1x150 mm) preceded by Atlantis guard column of matching chemistry. Analytes were subjected to LCMS analysis using positive electrospray ionization.
Key Results: The method was linear over the range 5-400 nmol/L. The limits of detection and quantification were 1.6 and 5 nmol/L for individual polyglutamates and 1.5 and 4.5 nmol/L for total polyglutamates, respectively. The method has been applied successfully to the determination of DBS finger-prick samples from 47 paediatric patients and results confirmed with concentrations measured in matched RBC samples using conventional HPLC-UV technique.
Conclusions and Clinical Relevance: The methodology has a potential for application in a range of clinical studies (e.g. pharmacokinetic evaluations or medication adherence assessment) since it is minimally invasive and easy to perform, potentially allowing parents to take blood samples at home. The feasibility of using DBS sampling can be of major value for future clinical trials or clinical care in paediatric rheumatology. © 2014 Hawwa et al.
Resumo:
Objectives: To explore children's views on microneedle use for this population, particularly as an alternative approach to blood sampling, in monitoring applications, and so, examine the acceptability of this approach to children.
Methods: Focus groups were conducted with children (aged 10-14 years) in a range of schools across Northern Ireland. Convenience sampling was employed, i.e. children involved in a university-directed community-outreach project (Pharmacists in Schools) were recruited.
Key findings: A total of 86 children participated in 13 focus groups across seven schools in Northern Ireland. A widespread disapproval for blood sampling was evident, with pain, blood and traditional needle visualisation particularly unpopular aspects. In general, microneedles had greater visual acceptability and caused less fear. A patch-based design enabled minimal patient awareness of the monitoring procedure, with personalised designs, e.g. cartoon themes, favoured. Children's concerns included possible allergy and potential inaccuracies with this novel approach; however, many had confidence in the judgement of healthcare professionals if deeming this technique appropriate. They considered paediatric patient education critical for acceptance of this new approach and called for an alternative name, without any reference to 'needles'.
Conclusions: The findings presented here support the development of blood-free, minimally invasive techniques and provide an initial indication of microneedle acceptability in children, particularly for monitoring purposes. A proactive response to these unique insights should enable microneedle array design to better meet the needs of this end-user group. Further work in this area is recommended to ascertain the perspectives of a purposive sample of children with chronic conditions who require regular monitoring. © 2013 Royal Pharmaceutical Society.
Resumo:
Many kinetic models have appeared in literature in past decades using two main approaches: the traditional global kinetics approach, or the more complex micro-kinetics approach. Whether global or micro-kinetics, kinetic models have been based on experimental data obtained at the end of the monolith. The experimental procedure using end pipe analysis may give an accurate overview of the reaction mechanisms that occur; however, the lack of information from within the catalyst can ultimately lead to inaccuracies in the kinetic model and parameters used.
Using SpaciMS, a spatially resolved experimental technique developed at the Queen's University Belfast, information from within the catalyst can be obtained. This minimally invasive technique provides detailed information of the gas concentration and temperature profile from inside the catalytic monolith. This paper presents a kinetic model and simulations validated against experimental data obtained from three positions inside the catalyst monolith at 2, 14, and 26 mm in, using data from the SpaciMS. Also, simulations of end pipe analysis, using a commercial reactor, for the CO oxidation are presented and analyzed. The simulations presented are for varying concentrations of both CO and O2 (0.5 % and 1 % CO, 0.5 % and 2 % O2) for both the global and micro-kinetic approach.
Resumo:
Increased adult cardiac fibroblast proliferation results in an increased collagen deposition responsible for the fibrosis accompanying pathological remodelling of the heart. The mechanisms regulating cardiac fibroblast proliferation remain poorly understood. Using a minimally invasive transverse aortic banding (MTAB) mouse model of cardiac hypertrophy, we have assessed fibrosis and cardiac fibroblast proliferation. We have investigated whether calcium/calmodulin-dependent protein kinase IIδ (CaMKIIδ) regulates proliferation in fibroblasts isolated from normal and hypertrophied hearts. It is known that CaMKIIδ plays a central role in cardiac myocyte contractility, but nothing is known of its role in adult cardiac fibroblast function. The MTAB model used here produces extensive hypertrophy and fibrosis. CaMKIIδ protein expression and activity is upregulated in MTAB hearts and, specifically, in cardiac fibroblasts isolated from hypertrophied hearts. In response to angiotensin II, cardiac fibroblasts isolated from MTAB hearts show increased proliferation rates. Inhibition of CaMKII with autocamtide inhibitory peptide inhibits proliferation in cells isolated from both sham and MTAB hearts, with a significantly greater effect evident in MTAB cells. These results are the first to show selective upregulation of CaMKIIδ in adult cardiac fibroblasts following cardiac hypertrophy and to assign a previously unrecognised role to CaMKII in regulating adult cardiac fibroblast function in normal and diseased hearts.
Resumo:
Ten million people in the UK today are aged over 65. The latest projections estimate that there will be 5 1/2 million more people aged 65 and older in the next 20 years. This projected pattern of population ageing will have profound consequences for dentistry. Minimal intervention dentistry (MID) is a modern evidence-based approach to caries management in dentate patients that uses the 'medical model' whereby disease is controlled by the 'oral physician'. This approach offers considerable benefits over conventional dentistry for older patients. It encourages patients to be responsible for their oral health through the provision of both knowledge and motivation. MID encompasses risk assessment for dental disease, early detection and control of disease processes, and minimally invasive treatment.
Clinical Relevance: Risk assessment tools can aid the general dental practitioner and the patient to develop a suitable caries prevention programme for that individual and reduce the need for future operative intervention.
Resumo:
Population trends suggest that the Irish population is ageing, and that this population will have substantial treatment needs. These patients will be better informed than previous generations, and will demand treatment aimed at preserving a natural dentition. This will impact upon delivery of oral healthcare and manpower planning needs to consider how to address the increased demand for dental care. Poor oral health is associated with systemic health problems, including cardiovascular disease, respiratory disease and diabetes mellitus. It also has a negative impact upon quality of life, and the World Health Organisation has encouraged public healthcare administrators and decision makers to design effective and affordable strategies for better oral health and quality of life of older adults, which, in turn, are integrated into general health management programmes. Treatment concepts such as minimally invasive dentistry and the shortened dental arch concept are discussed in the context of these demographic changes and recommendations.
Resumo:
Microneedles (MNs) are a minimally invasive drug delivery platform, designed to enhance transdermal drug delivery by breaching the stratum corneum. For the first time, this study describes the simultaneous delivery of a combination of three drugs using a dissolving polymeric MN system. In the present study, aspirin, lisinopril dihydrate, and atorvastatin calcium trihydrate were used as exemplar cardiovascular drugs and formulated into MN arrays using two biocompatible polymers, poly(vinylpyrrollidone) and poly(methylvinylether/maleic acid). Following fabrication, dissolution, mechanical testing, and determination of drug recovery from the MN arrays, in vitro drug delivery studies were undertaken, followed by HPLC analysis. All three drugs were successfully delivered in vitro across neonatal porcine skin, with similar permeation profiles achieved from both polymer formulations. An average of 126.3 ± 18.1 μg of atorvastatin calcium trihydrate was delivered, notably lower than the 687.9 ± 101.3 μg of lisinopril and 3924 ± 1011 μg of aspirin, because of the hydrophobic nature of the atorvastatin molecule and hence poor dissolution from the array. Polymer deposition into the skin may be an issue with repeat application of such a MN array, hence future work will consider more appropriate MN systems for continuous use, alongside tailoring delivery to less hydrophilic compounds.
Resumo:
Microneedles (MNs) are micron-sized, minimally invasive devices that breach the outermost layer of the skin, the stratum corneum (SC), creating transient, aqueous pores in the skin and facilitating the transport of therapeutic molecules into the epidermis. Following many years of extensive research in the area of MN-mediated trans- and intra-dermal drug delivery, MNs are now being exploited in the cosmeceutical industry as a means of disrupting skin cell architecture, inducing elastin and collagen expression and deposition. They are also being used as vehicles to deliver cosmeceutic molecules across the skin, in addition to their use in combinatorial treatments with topical agents or light sources. This review explores the chronology of microneedling methodologies, which has led to the emergence of MN devices, now extensively used in cosmeceutical applications. Recent developments in therapeutic molecule and peptide delivery to the skin via MN platforms are addressed and some commercially available MN devices are described. Important safety and regulatory considerations relating to MN usage are addressed, as are studies relating to public perception of MN, as these will undoubtedly influence the acceptance of MN products as they progress towards commercialisation.
Resumo:
OBJECTIVES: Microneedle (MN) arrays could offer a pain-free, minimally invasive approach to monitoring. This is envisaged to be particularly beneficial for younger patients, but parents' views to date are unknown. The aim of this study was to explore parental perceptions of MN-mediated ISF monitoring, as an alternative to the use of conventional blood sampling, and to understand the important factors for technique approval.
METHODS: Semi-structured interviews were conducted with parents with recent experience of a premature birth. Recruitment was through the Northern Ireland premature infant charity, Tinylife. Interviews progressed until data saturation was reached and thematic analysis employed.
KEY FINDINGS: The study included 16 parents. Parental support for MN-mediated monitoring was evident, alongside the unpopularity of traditional blood sampling in neonates. Factors facilitating MN approval included the opportunity for pain reduction, the simplicity of the procedure, the potential for increased parental involvement and the more favourable appearance, owing to the minute size of MNs and similarities with a sticking plaster. Confirmation of correct application, a pain-free patch removal and endorsement from trusted healthcare professionals were important.
CONCLUSION: These findings will inform researchers in the field of MN development and enlighten practitioners regarding parental distress resulting from conventional blood sampling. Further work is necessary to understand MN acceptability among practitioners. This work should assist in the development of an acceptable MN device and facilitate the reduction of parental distress.
Resumo:
Research based upon microneedle (MN) arrays has intensified recently. While the initial focus was on biomolecules, the field has expanded to include delivery of conventional small-molecule drugs whose water solubility currently precludes transdermal administration. Much success has been achieved, with peptides, proteins, vaccines, antibodies and even particulates delivered by MN in therapeutic/prophylactic doses. Recent innovations have focused on enhanced formulation design, scalable manufacture and extension of exploitation to minimally invasive patient monitoring, ocular delivery and enhanced administration of cosmeceuticals. Only two MN-based drug/vaccine delivery products are currently marketed, partially due to limitations with older MN designs based upon silicon and metal. Even the more promising polymeric MN have raised a number of regulatory and manufacturability queries that the field must address. MN arrays have tremendous potential to yield real benefits for patients and industry and, through diligence, innovation and collaboration, this will begin to be realised over the next 3-5 years.
Resumo:
OBJECTIVES: We aimed to highlight the utility of novel dissolving microneedle (MN)-based delivery systems for enhanced transdermal protein delivery. Vaccination remains the most accepted and effective approach in offering protection from infectious diseases. In recent years, much interest has focused on the possibility of using minimally invasive MN technologies to replace conventional hypodermic vaccine injections.
METHODS: The focus of this study was exploitation of dissolving MN array devices fabricated from 20% w/w poly(methyl vinyl ether/maleic acid) using a micromoulding technique, for the facilitated delivery of a model antigen, ovalbumin (OVA).
KEY FINDINGS: A series of in-vitro and in-vivo experiments were designed to demonstrate that MN arrays loaded with OVA penetrated the stratum corneum and delivered their payload systemically. The latter was evidenced by the activation of both humoral and cellular inflammatory responses in mice, indicated by the production of immunoglobulins (IgG, IgG1, IgG2a) and inflammatory cytokines, specifically interferon-gamma and interleukin-4. Importantly, the structural integrity of the OVA following incorporation into the MN arrays was maintained.
CONCLUSION: While enhanced manufacturing strategies are required to improve delivery efficiency and reduce waste, dissolving MN are a promising candidate for 'reduced-risk' vaccination and protein delivery strategies.
Resumo:
Rapid in situ diagnosis of damage is a key issue in the preservation of stone-built cultural heritage. This is evident in the increasing number of congresses, workshops and publications dealing with this issue. With this increased activity has come, however, the realisation that for many culturally significant artefacts it is not possible either to remove samples for analysis or to affix surface markers for measurement. It is for this reason that there has been a growth of interest in non-destructive and minimally invasive techniques for characterising internal and external stone condition. With this interest has come the realisation that no single technique can adequately encompass the wide variety of parameters to be assessed or provide the range of information required to identify appropriate conservation. In this paper we describe a strategy to address these problems through the development of an integrated `tool kit' of measurement and analytical techniques aimed specifically at linking object-specific research to appropriate intervention. The strategy is based initially upon the acquisition of accurate three-dimensional models of stone-built heritage at different scales using a combination of millimetre accurate LiDAR and sub-millimetre accurate Object Scanning that can be exported into a GIS or directly into CAD. These are currently used to overlay information on stone characteristics obtained through a combination of Ground Penetrating Radar, Surface Permeametry, Colorimetry and X-ray Fluorescence, but the possibility exists for adding to this array of techniques as appropriate. In addition to the integrated three-dimensional data array provided by superimposition upon Digital Terrain Models, there is the capability of accurate re-measurement to show patterns of surface loss and changes in material condition over time. Thus it is possible to both record and base-line condition and to identify areas that require either preventive maintenance or more significant pre-emptive intervention. In pursuit of these goals the authors are developing, through a UK Government supported collaboration between University Researchers and Conservation Architects, commercially viable protocols for damage diagnosis, condition monitoring and eventually mechanisms for prioritizing repairs to stone-built heritage. The understanding is, however, that such strategies are not age-constrained and can ultimately be applied to structures of any age.