959 resultados para MESENTERIC-ARTERIES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A single high loading dose of 25 mg/kg caffeine has been shown to be effective for the prevention of apnoea, but may result in considerable reductions in blood flow velocity (BFV) in cerebral and intestinal arteries. OBJECTIVE: To assess the effects of two loading doses of 12.5 mg/kg caffeine given four hours apart on BFV in cerebral and intestinal arteries, left ventricular output (LVO), and plasma caffeine concentrations in preterm infants. DESIGN: Sixteen preterm neonates of <34 weeks gestation were investigated one hour after the first oral dose and one, two, and 20 hours after the second dose by Doppler sonography. RESULTS: The mean (SD) plasma caffeine concentrations were 31 (7) and 29 (7) mg/l at two and 20 hours respectively after the second dose. One hour after the first dose, none of the circulatory variables had changed significantly. One hour after the second caffeine dose, mean BFV in the internal carotid artery and anterior cerebral artery showed significant reductions of 17% and 19% (p = 0.01 and p = 0.003 respectively). BFV in the coeliac artery and superior mesenteric artery, LVO, PCO2, and respiratory rate had not changed significantly. Total vascular resistance, calculated as the ratio of mean blood pressure to LVO, had increased significantly one and two hours after the second dose (p = 0.049 and p = 0.023 respectively). CONCLUSION: A divided high loading dose of 25 mg/kg caffeine given four hours apart had decreased BFV in cerebral arteries after the second dose, whereas BFV in intestinal arteries and LVO were not affected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study analyzes the results of the arterial switch operation for transposition of the great arteries in member institutions of the European Congenital Heart Surgeons Association. METHODS: The records of 613 patients who underwent primary arterial switch operations in each of 19 participating institutions in the period from January 1998 through December 2000 were reviewed retrospectively. RESULTS: A ventricular septal defect was present in 186 (30%) patients. Coronary anatomy was type A in 69% of the patients, and aortic arch pathology was present in 20% of patients with ventricular septal defect. Rashkind septostomy was performed in 75% of the patients, and 69% received prostaglandin. There were 37 hospital deaths (operative mortality, 6%), 13 (3%) for patients with an intact ventricular septum and 24 (13%) for those with a ventricular septal defect (P < .001). In 36% delayed sternal closure was performed, 8% required peritoneal dialysis, and 2% required mechanical circulatory support. Median ventilation time was 58 hours, and intensive care and hospital stay were 6 and 14 days, respectively. Although of various preoperative risk factors the presence of a ventricular septal defect, arch pathology, and coronary anomalies were univariate predictors of operative mortality, only the presence of a ventricular septal defect approached statistical significance (P = .06) on multivariable analysis. Of various operative parameters, aortic crossclamp time and delayed sternal closure were also univariate predictors; however, only the latter was an independent statistically significant predictor of death. CONCLUSIONS: Results of the procedure in European centers are compatible with those in the literature. The presence of a ventricular septal defect is the clinically most important preoperative risk factor for operative death, approaching statistical significance on multivariable analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Coronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents. METHODS: We enrolled 63 patients (44 men; mean age 61.3 [SD 9.5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 months FINDINGS: 71 stents, 10-15 mm in length and 3.0-3.5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61.5 (SD 13.1%) to 12.6 (5.6%) with an acute gain of 1.41 mm (0.46 mm) and in-stent late loss of 1.08 mm (0.49 mm). The ischaemia-driven target lesion revascularisation rate was 23.8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48.4 (17.0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis. INTERPRETATION: This study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The patency rate of radial artery (RA) conduits is considerably lower than that of internal thoracic artery (ITA) grafts and the evidence suggests that this is due to a clinically suspected higher incidence of vasospasm. The aim of this study was, therefore, to compare intraindividually the pharmacological reactivity of RA with that of ITA. Both RA and ITA were taken from the same patients and investigated in parallel. Changes in tone were monitored isometrically on ring preparations from both arteries in organ baths with modified Krebs-Henseleit solution containing 1.25 mm calcium chloride at 1 g passive preload. In intraindividual comparisons maximal receptor-mediated contractile responses to noradrenaline and endothelin-1 and endothelium-dependent acetylcholine-induced relaxant responses revealed no differences between both arteries. By contrast, depolarization-induced contractions to potassium chloride (KCl) appeared to be significantly higher in RA than in ITA. Further analysis, however, revealed that this difference was due to preoperative calcium entry blocker (Ca(2+)eB) therapy. Compared with control tissues, maximal responses to KCl were significantly attenuated in the ITA but unchanged in RA when arteries were obtained from patients with preoperative Ca(2+)eB therapy. The present results suggested that functional responses to pharmacological stimuli of both RA and ITA were quite similar. Preoperative Ca(2+)eB therapy, however, attenuated markedly responses to KCl of the ITA leaving those of RA unchanged. These results, demonstrating a lower sensitivity to Ca(2+)eB of RA, therefore suggested that in addition to Ca(2+)eB other classes of drug may be more effective at reducing the propensity of RA conduits to vasospasm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endovascular therapy is a rapidly evolving field for the treatment of patients with peripheral arterial disease, and a magnitude of studies reporting on various modern revascularization concepts have been recently published. Thus, studies assessing the efficacy of endovascular therapy of peripheral arteries do not operate with uniformly defined endpoints, rendering a direct comparison of studies difficult. The purpose of this consensus statement is to highlight differences in the terminology used in the current literature and to propose some standardized criteria that must be considered when reporting results of endovascular revascularization for chronic ischaemia of lower limb arteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Orthogonal polarization spectral (OPS) imaging is used to assess mucosal microcirculation. We tested sensitivity and variability of OPS in the assessment of mesenteric blood flow (Q (sma)) reduction. SETTING: University Animal Laboratory. INTERVENTIONS: In eight pigs, Q (sma) was reduced in steps of 15% from baseline; five animals served as controls. Jejunal mucosal microcirculatory blood flow was recorded with OPS and laser Doppler flowmetry at each step. OPS data from each period were collected and randomly ordered. Samples from each period were individually chosen by two blinded investigators and quantified [capillary density (number of vessels crossing predefined lines), number of perfused villi] after agreement on the methodology. MEASUREMENT AND RESULTS: Interobserver coefficient of variation (CV) for capillary density from samples representing the same flow condition was 0.34 (0.04-1.41) and intraobserver CV was 0.10 (0.02-0.61). Only one investigator observed a decrease in capillary density [to 62% (48-82%) of baseline values at 45% Q (sma) reduction; P = 0.011], but comparisons with controls never revealed significant differences. In contrast, reduction in perfused villi was detected by both investigators at 75% of mesenteric blood flow reduction. Laser Doppler flow revealed heterogeneous microcirculatory perfusion. CONCLUSIONS: Assessment of capillary density did not reveal differences between animals with and without Q (sma) reduction, and evaluation of perfused villi revealed blood flow reduction only when Q (sma) was very low. Potential explanations are blood flow redistribution and heterogeneity, and suboptimal contrast of OPS images. Despite agreement on the method of analysis, interobserver differences in the quantification of vessel density on gut mucosa using OPS are high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine the accuracy of automated vessel-segmentation software for vessel-diameter measurements based on three-dimensional contrast-enhanced magnetic resonance angiography (3D-MRA). METHOD: In 10 patients with high-grade carotid stenosis, automated measurements of both carotid arteries were obtained with 3D-MRA by two independent investigators and compared with manual measurements obtained by digital subtraction angiography (DSA) and 2D maximum-intensity projection (2D-MIP) based on MRA and duplex ultrasonography (US). In 42 patients undergoing carotid endarterectomy (CEA), intraoperative measurements (IOP) were compared with postoperative 3D-MRA and US. RESULTS: Mean interoperator variability was 8% for measurements by DSA and 11% by 2D-MIP, but there was no interoperator variability with the automated 3D-MRA analysis. Good correlations were found between DSA (standard of reference), manual 2D-MIP (rP=0.6) and automated 3D-MRA (rP=0.8). Excellent correlations were found between IOP, 3D-MRA (rP=0.93) and US (rP=0.83). CONCLUSION: Automated 3D-MRA-based vessel segmentation and quantification result in accurate measurements of extracerebral-vessel dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In contrast to the current belief that angiotensin II (Ang II) interacts with the sympathetic nervous system only as a circulating hormone, we document here the existence of endogenous Ang II in the neurons of rat and human sympathetic coeliac ganglia and their angiotensinergic innervation with mesenteric resistance blood vessels. Angiotensinogen - and angiotensin converting enzyme-mRNA were detected by using quantitative real time polymerase chain reaction in total RNA extracts of rat coeliac ganglia, while renin mRNA was untraceable. Cathepsin D, a protease responsible for cleavage beneath other substrates also angiotensinogen to angiotensin I, was successfully detected in rat coeliac ganglia indicating the possibility of existence of alternative pathways. Angiotensinogen mRNA was also detected by in situ hybridization in the cytoplasm of neurons of rat coeliac ganglia. Immunoreactivity for Ang II was demonstrated in rat and human coeliac ganglia as well as with mesenteric resistance blood vessels. By using confocal laser scanning microscopy we were able to demonstrate the presence of angiotensinergic synapses en passant along side of vascular smooth muscle cells. Our findings indicate that Ang II is synthesized inside the neurons of sympathetic coeliac ganglia and may act as an endogenous neurotransmitter locally with the mesenteric resistance blood vessels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Perforating arteries are commonly involved during the surgical dissection and clipping of intracranial aneurysms. Occlusion of perforating arteries is responsible for ischemic infarction and poor outcome. The goal of this study is to describe the usefulness of near-infrared indocyanine green videoangiography (ICGA) for the intraoperative assessment of blood flow in perforating arteries that are visible in the surgical field during clipping of intracranial aneurysms. In addition, we analyzed the incidence of perforating vessels involved during the aneurysm surgery and the incidence of ischemic infarct caused by compromised small arteries. METHODS: Sixty patients with 64 aneurysms were surgically treated and prospectively included in this study. Intraoperative ICGA was performed using a surgical microscope (Carl Zeiss Co., Oberkochen, Germany) with integrated ICGA technology. The presence and involvement of perforating arteries were analyzed in the microsurgical field during surgical dissection and clip application. Assessment of vascular patency after clipping was also investigated. Only those small arteries that were not visible on preoperative digital subtraction angiography were considered for analysis. RESULTS: The ICGA was able to visualize flow in all patients in whom perforating vessels were found in the microscope field. Among 36 patients whose perforating vessels were visible on ICGA, 11 (30%) presented a close relation between the aneurysm and perforating arteries. In one (9%) of these 11 patients, ICGA showed occlusion of a P1 perforating artery after clip application, which led to immediate correction of the clip confirmed by immediate reestablishment of flow visible with ICGA without clinical consequences. Four patients (6.7%) presented with postoperative perforating artery infarct, three of whom had perforating arteries that were not visible or distant from the aneurysm. CONCLUSION: The involvement of perforating arteries during clip application for aneurysm occlusion is a usual finding. Intraoperative ICGA may provide visual information with regard to the patency of these small vessels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Transcranial Doppler sonography (TCD) is an established method for assessing changes in blood flow velocity (BFV) coupled to brain activity. Our objective was to investigate whether walking induces measurable changes in BFV in healthy subjects. METHODS: Changes in BFV in both middle cerebral arteries (MCAs) of 40 healthy adult subjects during walking on a treadmill were measured using bilateral TCD. In 8 of the 40 subjects, 1 anterior cerebral artery (ACA) was monitored simultaneously with the contralateral MCA. The percentage increase in BFV (BFVI%) compared with the baseline velocity (V(0)), the percentage decrease in BFV (BFVD%) compared with the V(0), and the normalized ACA-MCA ratio were analyzed. RESULTS: The overall mean (+/- standard deviation [SD]) V(0) was 59.9 +/- 11.6 cm/second in the left MCA and 60.1 +/- 12.9 cm/second in the right MCA. Women had higher V(0) values than men had. Walking evoked an initial mean overall BFVI% in both left (8.4 +/- 5.1%) and right MCAs (9.1 +/- 5.1%), followed by a decrease to below baseline values in 38 of 40 subjects. A statistically significant increase of the normalized ACA-MCA ratio was measured, indicating that changes in BFV in the ACA territory were coupled to brain activation during walking. CONCLUSIONS: The use of functional TCD showed different changes in BFV in the ACAs and MCAs during walking. This method may be an interesting tool for monitoring progress in patients with motor deficits of the legs, such as paresis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this analysis was to compare vasoreactive properties of internal thoracic arteries (ITA) grafts from diabetic (DM) to those of non-diabetic (ND) patients. Ring segments of ITA, taken from patients undergoing coronary artery bypass grafting, were suspended in organ bath chambers filled with modified Krebs-Henseleit solution and contractile responses to potassium chloride (KCl), noradrenaline (NA), endothelin-1 (ET-l), and endothelium-dependent relaxant responses to acetylcholine (ACH) were recorded isometrically. The receptor-mediated agonists NA and ET-1 stimulated ITA from both groups within similar concentration ranges while ITA from DM patients proved to be significantly more sensitive to KCl than ITA from ND. Furthermore, maximal contractile responses indicated that KCl (3.79 +/- 0.30 g, n = 7 in DM and 2.50 +/- 0.23 g, n = 29 in ND, P < 0.05) evoked significantly higher responses in ITA from DM as compared to the ND control group while both NA and ET-l stimulated ITA from both groups with similar efficacies. Endothelium-dependent relaxant responses to ACH proved to be similar in both groups when expressed as percentages of the pre-existing tone. The present data support the contention that in comparison to ND controls arteries from DM patients are more sensitive to depolarization but endothelial dysfunction is less frequent in human ITA than expected from observations in systemic vascular beds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Different stents in infrainguinal arteries have recently been associated with stent fractures and unfavorable clinical outcome, although data is limited regarding fractures of the Xpert selfexpanding nitinol stent. Thus, purpose of the present investigation was to evaluate its incidence and clinical implications in lower limb arteries. PATIENTS AND METHODS: Fifty-three consecutive patients (53 limbs) with peripheral arterial disease underwent secondary Xpert stent implantation due to suboptimal primary balloon angioplasty (PTA). Median age was 76 years. Stent fractures were evaluated by plain X-ray at median follow-up of 16 months. Stent patency was assessed by duplex ultrasound and sustained clinical improvement was defined as improvement of the ABI of > or = 0.10 together with improvement of at least one Rutherford class above the baseline finding throughout follow-up. RESULTS: Median length of femoropopliteal and infrapopliteal lesion was 3.0 and 2.3 cm, respectively. Sixtyfive stents were implanted in 43 limbs with femoropopliteal and 10 stents in 10 limbs with infrapopliteal lesion, respectively. Stent fractures occurred in 3 of 43 limbs (7.0%) of patients with femoropopliteal lesion with stent-based fracture rate of 4.6%. All fractured stents showed multiple struts fractures and occurred in the distal and middle superficial femoral artery. No stent fracture was observed in infrapopliteal lesions. The fractured stents were not associated with any clinical deterioration. Sustained clinical improvement was 71.0% and 54.6% for femoropopliteal and infrapopliteal lesions, respectively. Stent patency assessed by duplex was 65.2 and 63.9% for femoropopliteal and infrapopliteal lesions, respectively. CONCLUSIONS: Fractures of the Xpert stent were seldom and not associated with unfavorable clinical outcome at midterm follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To prospectively compare the diagnostic accuracy of steady-state, high-spatial-resolution magnetic resonance (MR) angiography of the lower leg, performed with a blood pool contrast agent, with selective digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial disease.