966 resultados para Métodos Analíticos
Resumo:
The dating of sediments in lakes, estuaries and rivers through radionuclides, when applied in association with other analitic methods (heavy metals, organic contaminants, etc.) allows analyses of the anthropogenic interference in the environment along the years. A geochronology of a sediment core from Untersee in Lake Constance, one of the most important hydric resources of Europe, was established through the Pb-210 method and adopting the CRS parameter (Constant Rate of Supply). The Cs-137 was successfully used to give basis to the results, as its additional input occurred in Chernobyl’s accident can be used as a marker to the year 1986. Associating the dating with the cores depth, the average mass accumulation rate and the sedimentation rate for the site were assessed (0,14 g/cm²/year and 4 mm/year respectively).
Resumo:
O nitrato de fenticonazol é um derivado imidazólico de amplo espectro de ação contra patógenos dermatófitos, como Malassezia furfur e leveduras, a principal delas Candida albicans. É necessário que se possa garantir a qualidade dos medicamentos produzidos. O controle de qualidade é uma ferramenta que assegura a qualidade, eficácia e segurança desses produtos até o momento de sua utilização e faz-se necessário que métodos analíticos sejam desenvolvidos e validados para o doseamento desses fármacos. A grande importância dos métodos microbiológicos utilizados no controle de qualidade de fármacos com atividade antimicrobiana é demonstrar sua atividade biológica por meio de seu efeito inibitório no crescimento de micro-organismo. A diminuição da atividade antimicrobiana ou potência pode indicar alguma alteração sutil na molécula, que é pouco detectável em um método analítico físico-químico. O objetivo deste trabalho foi desenvolver e validar o método microbiológico difusão em ágar para o produto nitrato de fenticonazol creme vaginal. O método de difusão em ágar foi desenvolvido utilizando meio de cultura ágar Sabouraud e cepa de Candida albicans ATCC 64548 como micro-organismo teste. Para o ensaio foi utilizado o delineamento 3 x 3, conforme preconiza a Farmacopeia Brasileira (2010). A validação do método proposto demonstrou linearidade entre os diâmetros dos halos de inibição e o logaritmo da concentração na faixa de 50,0 a 200,0 μg/mL. O método obteve resultados precisos e lineares com r2=1. A exatidão foi comprovada pelo intervalo de tolerância de 98,83%, dentro dos limites permitidos. O método foi validado de maneira satisfatória, podendo ser utilizado em análises do Controle de Qualidade deste fármaco.
Resumo:
The SPECT (Single Photon Emission Computed Tomography) systems are part of a medical image acquisition technology which has been outstanding, because the resultant images are functional images complementary to those that give anatomic information, such as X-Ray CT, presenting a high diagnostic value. These equipments acquire, in a non-invasive way, images from the interior of the human body through tomographic mapping of radioactive material administered to the patient. The SPECT systems are based on the Gamma Camera detection system, and one of them being set on a rotational gantry is enough to obtain the necessary data for a tomographic image. The images obtained from the SPECT system consist in a group of flat images that describe the radioactive distribution on the patient. The trans-axial cuts are obtained from the tomographic reconstruction techniques. There are analytic and iterative methods to obtain the tomographic reconstruction. The analytic methods are based on the Fourier Cut Theorem (FCT), while the iterative methods search for numeric solutions to solve the equations from the projections. Within the analytic methods, the filtered backprojection (FBP) method maybe is the simplest of all the tomographic reconstruction techniques. This paper's goal is to present the operation of the SPECT system, the Gamma Camera detection system, some tomographic reconstruction techniques and the requisites for the implementation of this system in a Nuclear Medicine service
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Brazilian red wines are very appreciated by consumers from tropical regions, because they typically have aromatic and fruity taste. Thus, the aim of this article is to verify the quality of red wines from wineries located in Northwest region of São Paulo, based on the relationship between physicochemical properties and sensory attributes. Three red wines from this region was evaluated by sensory and analytical methods and it was possible to observe significant differences in the fixed acidity, alcoholic content, total phenolic content and total dry extract. Multidimensional Scaling showed relationship between total phenolic content and astringency, total dry extract and body and the relationship of volatile acidity in the assessment of odor samples. It was possible to see the physicochemical influence in sensory evaluation, indicating the importance of the chemical profile in the elucidation of possible sensory alterations in red wines.
Resumo:
Indiscriminate and inappropriate use of pesticides in agriculture has been pointed out for increasing health problems and environmental damage. Considering that water resources are the principal destiny of those compounds after application, the present study presents optimization and validation of two simple and effi cient analytical methods for pesticides quantifi cation in both surface and groundwater. Were selected the pesticides more commonly used at Dourados (MS - Brazil), region with intense agricultural activity. Pesticides were preconcentrated by solid-phase extraction using C18 (500 mg) cartridges and then divided in two groups for elution and quantifi cation: 2.4-D and 2.4-DCP were eluted with methanol and quantifi ed by high performance liquid chromatography with ultra-violet detector (HPLC-UV) while atrazine, DIA, DEA, trifl uralin and methyl parathion were eluted with ethylacetate (1:1, v/v) and quantifi ed by gas chromatography with thermionic specifi c detector (GC-TSD). The methods showed satisfactory accuracy (76-107%) and precision (<12%) for the substances analyzed at the fortifi ed levels selected for the study, except for DIA (<51%). Study of pesticide stability also presented good results: C18 cartridges could be stored for at least for 21 days at -20ºC with no signs of the compounds degradability. Both methods limits of quantifi cation of the pesticides (0.22 - 0.48 μg L-1) are in accordance to the levels currently established by the Brazilian national legislation for pesticides in water. Although only the pesticide 2.4-D has been detected in two distinct collection points in the study period of time, this work warns for the requirement of systematical analysis of pesticides presence in water destined to human consume, principally in areas of intense agriculture activity. Such monitoring can provide subsidies for public environmental policies.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Ciências Farmacêuticas - FCFAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Sabendo-se do potencial de toxicidade do mercúrio, mais especificamente de sua forma orgânica, o metilmercúrio (MeHg), faz-se necessária a busca por métodos analíticos eficientes e precisos para a determinação e especiação do metal. A técnica de difusão por gradiente em filmes finos (DGT) já vem sendo utilizada para tal fim de maneira eficiente tendo apresentado resultados satisfatórios em diversos estudos. Porém, a utilização de ligantes alternativos aos convencionais, que tornem a aplicação da técnica menos custosa em termos laborais e financeiros, faz-se importante para um monitoramento constante e eficiente do metilmercúrio no ambiente. No presente trabalho buscou-se avaliar o potencial da levedura Saccharomyces cerevisiae imobilizada em agarose em combinação com a poliacrilamida como agente difusivo para determinação seletiva de MeHg. Os resultados demonstraram-se positivo, com um coeficiente de difusão médio de 7,03 ± 0,77 x 10-6 cm2 s-1. Os resultados demonstraram também baixa influencia do pH, força iônica e outros íons na retenção do analito pelos dispositivos. As recuperações de Hg2+ demonstraram-se insatisfatórios, evidenciando a seletividade dos dispositivos
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Ciências Farmacêuticas - FCFAR