854 resultados para Life support care, pediartics
Resumo:
Correctly performed basic life support (BLS) and early defibrillation are the most effective measures to treat sudden cardiac arrest. Audiovisual feedback improves BLS. Automated external defibrillators (AED) with feedback technology may play an important role in improving CPR quality. The aim of this simulation study was to investigate if an AED with audiovisual feedback improves CPR parameters during standard BLS performed by trained laypersons.
Resumo:
The goal of this randomized, open, controlled crossover manikin study was to compare the performance of "Animax", a manually operated hand-powered mechanical resuscitation device (MRD) to standard single rescuer basic life support (BLS).
Resumo:
Cardiopulmonary resuscitation (CPR) during flight is challenging and has to be sustained for long periods. In this setting a mechanical-resuscitation-device (MRD) might improve performance. In this study we compared the quality of resuscitation of trained flight attendants practicing either standard basic life support (BLS) or using a MRD in a cabin-simulator.
Resumo:
Lodox Statscan provides high-speed, high-quality, low radiation, full body imaging in a single scan, combined with three-dimensional reconstructive and zooming functionality. Several trauma centres have incorporated it into their advanced trauma life support protocol. This review gives a brief overview of the system.
Resumo:
The goal of this experimental study was to investigate rescuer exertion when using "Animax," a manually operated hand-powered mechanical resuscitation device (MRD) for cardiopulmonary resuscitation (CPR), compared to standard basic life support (BLS).
Resumo:
PURPOSE: Computer-based feedback systems for assessing the quality of cardiopulmonary resuscitation (CPR) are widely used these days. Recordings usually involve compression and ventilation dependent variables. Thorax compression depth, sufficient decompression and correct hand position are displayed but interpreted independently of one another. We aimed to generate a parameter, which represents all the combined relevant parameters of compression to provide a rapid assessment of the quality of chest compression-the effective compression ratio (ECR). METHODS: The following parameters were used to determine the ECR: compression depth, correct hand position, correct decompression and the proportion of time used for chest compressions compared to the total time spent on CPR. Based on the ERC guidelines, we calculated that guideline compliant CPR (30:2) has a minimum ECR of 0.79. To calculate the ECR, we expanded the previously described software solution. In order to demonstrate the usefulness of the new ECR-parameter, we first performed a PubMed search for studies that included correct compression and no-flow time, after which we calculated the new parameter, the ECR. RESULTS: The PubMed search revealed 9 trials. Calculated ECR values ranged between 0.03 (for basic life support [BLS] study, two helpers, no feedback) and 0.67 (BLS with feedback from the 6th minute). CONCLUSION: ECR enables rapid, meaningful assessment of CPR and simplifies the comparability of studies as well as the individual performance of trainees. The structure of the software solution allows it to be easily adapted to any manikin, CPR feedback devices and different resuscitation guidelines (e.g. ILCOR, ERC).
Resumo:
INTRODUCTION: The incidence of bloodstream infection (BSI) in extracorporeal life support (ECLS) is reported between 0.9 and 19.5%. In January 2006, the Extracorporeal Life Support Organization (ELSO) reported an overall incidence of 8.78% distributed as follows: respiratory: 6.5% (neonatal), 20.8% (pediatric); cardiac: 8.2% (neonatal) and 12.6% (pediatric). METHOD: At BC Children's Hospital (BCCH) daily surveillance blood cultures (BC) are performed and antibiotic prophylaxis is not routinely recommended. Positive BC (BC+) were reviewed, including resistance profiles, collection time of BC+, time to positivity and mortality. White blood cell count, absolute neutrophile count, immature/total ratio, platelet count, fibrinogen and lactate were analyzed 48, 24 and 0 h prior to BSI. A univariate linear regression analysis was performed. RESULTS: From 1999 to 2005, 89 patients underwent ECLS. After exclusion, 84 patients were reviewed. The attack rate was 22.6% (19 BSI) and 13.1% after exclusion of coagulase-negative staphylococci (n = 8). BSI patients were significantly longer on ECLS (157 h) compared to the no-BSI group (127 h, 95% CI: 106-148). Six BSI patients died on ECLS (35%; 4 congenital diaphragmatic hernias, 1 hypoplastic left heart syndrome and 1 after a tetralogy repair). BCCH survival on ECLS was 71 and 58% at discharge, which is comparable to previous reports. No patient died primarily because of BSI. No BSI predictor was identified, although lactate may show a decreasing trend before BSI (P = 0.102). CONCLUSION: Compared with ELSO, the studied BSI incidence was higher with a comparable mortality. We speculate that our BSI rate is explained by underreporting of "contaminants" in the literature, the use of broad-spectrum antibiotic prophylaxis and a higher yield with daily monitoring BC. We support daily surveillance blood cultures as an alternative to antibiotic prophylaxis in the management of patients on ECLS.
Resumo:
ABSTRACT: BACKGROUND: Pelvic x-ray is a routine part of the primary survey of polytraumatized patients according to Advanced Trauma Life Support (ATLS) guidelines. However, pelvic CT is the gold standard imaging technique in the diagnosis of pelvic fractures. This study was conducted to confirm the safety of a modified ATLS algorithm omitting pelvic x-ray in hemodynamically stable polytraumatized patients with clinically stable pelvis in favour of later pelvic examination by CT scan. METHODS: We conducted a retrospective analysis of all polytraumatized patients in our emergency room between 01.07.2004 and 31.01.2006. Inclusion criteria were blunt abdominal trauma, initial hemodynamic stability and a stable pelvis on clinical examination. We excluded patients requiring immediate intervention because of hemodynamic instability. RESULTS: We reviewed the records of n = 452 polytraumatized patients, of which n = 91 fulfilled inclusion criteria (56% male, mean age = 45 years). The mechanism of trauma included 43% road traffic accidents, 47% falls. In 68/91 (75%) patients, both a pelvic x-ray and a CT examination were performed; the remainder had only pelvic CT. In 6/68 (9%) patients, pelvic fracture was diagnosed by pelvic x-ray. None of these 6 patients was found having a false positive pelvic x-ray, i.e. there was no fracture on pelvic CT scan. In 3/68 (4%) cases a fracture was missed in the pelvic x-ray, but confirmed on CT (false negative on x-ray). None of the diagnosed fractures needed an immediate therapeutic intervention. 5 (56%) were classified type A fractures, and another 4 (44%) B 2.1 in computed tomography (AO classification). One A 2.1 fracture was found in a clinically stable patient who only received CT scan (1/23). CONCLUSION: While pelvic x-ray is an integral part of ATLS assessment, this retrospective study suggests that in hemodynamically stable patients with clinically stable pevis, its sensitivity is only 67% and it may safely be omitted in favor of a pelvic CT examination if such is planned in adjunct assessment and available. The results support the safety and utility of our modified ATLS algorithm. A randomized controlled trial using the algorithm can safely be conducted to confirm the results.
Resumo:
BACKGROUND: Lodox-Statscan is a whole-body, skeletal and soft-tissue, low-dose X-ray scanner Anterior-posterior and lateral thoraco-abdominal studies are obtained in 3-5 minutes with only about one-third of the radiation required for conventional radiography. Since its approval by the Food and Drug Administration (FDA) in the USA, several trauma centers have incorporated this technology into their Advanced Trauma Life Support protocols. This review provides a brief overview of the system, and describes the authors' own experience with the system. METHODS: We performed a PubMed search to retrieve all references with 'Lodox' and 'Stat-scan' used as search terms. We furthermore used the google search engine to identify existing alternatives. To the best of our knowledge, this is the only FDA-approved device of its kind currently used in trauma. RESULTS AND CONCLUSION: The intention of our review has been to sensitize the readership that such alternative devices exist. The key message is that low dosage full body radiography may be an alternative to conventional resuscitation room radiography which is usually a prelude to CT scanning (ATLS algorithm). The combination of both is radiation intensive and therefore we consider any reduction of radiation a success. But only the future will show whether LS will survive in the face of low-dose radiation CT scanners and magnetic resonance imaging devices that may eventually completely replace conventional radiography.
Resumo:
Aims The effects of a system based on minimally trained first responders (FR) dispatched simultaneously with the emergency medical services (EMS) of the local hospital in a mixed urban and rural area in Northwestern Switzerland were examined. Methods and results In this prospective study 500 voluntary fire fighters received a 4-h training in basic-life-support using automated-external-defibrillation (AED). FR and EMS were simultaneously dispatched in a two-tier rescue system. During the years 2001–2008, response times, resuscitation interventions and outcomes were monitored. 1334 emergencies were included. The FR reached the patients (mean age 60.4 ± 19 years; 65% male) within 6 ± 3 min after emergency calls compared to 12 ± 5 min by the EMS (p < 0.0001). Seventy-six percent of the 297 OHCAs occurred at home. Only 3 emergencies with resuscitation attempts occurred at the main railway station equipped with an on-site AED. FR were on the scene before arrival of the EMS in 1166 (87.4%) cases. Of these, the FR used AED in 611 patients for monitoring or defibrillation. CPR was initiated by the FR in 164 (68.9% of 238 resuscitated patients). 124 patients were defibrillated, of whom 93 (75.0%) were defibrillated first by the FR. Eighteen patients (of whom 13 were defibrillated by the FR) were discharged from hospital in good neurological condition. Conclusions Minimally trained fire fighters integrated in an EMS as FR contributed substantially to an increase of the survival rate of OHCAs in a mixed urban and rural area.
Resumo:
Primary immunodeficiencies (PIDs)* belong to the group of rare diseases which need more awareness by the relevant medical disciplines. Below a review on recent progresses in diagnosis and treatment of PIDs is given. Reducing the regrettable delay in diagnosis of PIDs (worldwide) is possible only when awareness is increased by doctors who may encounter patients with PID. This review shall serve this purpose. Progresses in understanding what the link might be between one genetic defect presenting in various phenotypes or how various gene defects may manifest by very similar PID phenotypes helps building awareness. Knowledge of PID favours early diagnosis, a cornerstone of optimal, sometimes life-long care at justifiable costs. The complexity of PIDs calls for clinical laboratory and clinical diagnostic performed by experts only. Exciting laboratory diagnostic progresses in early diagnosis of the most severe forms of PID are reviewed below. Progresses in curative therapies for PIDs, such as hematopoietic stem cell transplantation and gene therapies, are mentioned in short. About 80% of PID patients suffer from an antibody deficiency syndrome and can profit from non-curative replacement therapies with human immunoglobulin G concentrates. Modes of application, safety and hints for dosing of replacement therapies to reduce frequencies of severe infections are mentioned below. Thanks to the increasing quality of care, patients survive adolescence. A glance is given on the problems of transition to the adult medicine setting.
Resumo:
BACKGROUND Efficiently performed basic life support (BLS) after cardiac arrest is proven to be effective. However, cardiopulmonary resuscitation (CPR) is strenuous and rescuers' performance declines rapidly over time. Audio-visual feedback devices reporting CPR quality may prevent this decline. We aimed to investigate the effect of various CPR feedback devices on CPR quality. METHODS In this open, prospective, randomised, controlled trial we compared three CPR feedback devices (PocketCPR, CPRmeter, iPhone app PocketCPR) with standard BLS without feedback in a simulated scenario. 240 trained medical students performed single rescuer BLS on a manikin for 8min. Effective compression (compressions with correct depth, pressure point and sufficient decompression) as well as compression rate, flow time fraction and ventilation parameters were compared between the four groups. RESULTS Study participants using the PocketCPR performed 17±19% effective compressions compared to 32±28% with CPRmeter, 25±27% with the iPhone app PocketCPR, and 35±30% applying standard BLS (PocketCPR vs. CPRmeter p=0.007, PocketCPR vs. standard BLS p=0.001, others: ns). PocketCPR and CPRmeter prevented a decline in effective compression over time, but overall performance in the PocketCPR group was considerably inferior to standard BLS. Compression depth and rate were within the range recommended in the guidelines in all groups. CONCLUSION While we found differences between the investigated CPR feedback devices, overall BLS quality was suboptimal in all groups. Surprisingly, effective compression was not improved by any CPR feedback device compared to standard BLS. All feedback devices caused substantial delay in starting CPR, which may worsen outcome.
Resumo:
Current guidelines for the treatment of hypothermic cardiocirculatory arrest recommend extracorporeal life support and rewarming, using cardiopulmonary bypass or extracorporeal membrane oxygenation circuits. Both have design-related shortcomings which may result in prolonged reperfusion time or insufficient oxygen delivery to vital organs. This article describes clear advantages of minimally invasive extracorporeal circulation systems during emergency extracorporeal life support in hypothermic arrest. The technique of minimally invasive extracorporeal circulation for reperfusion and rewarming is represented by the case of a 59-year-old patient in hypothermic cardiocirculatory arrest at 25.3°C core temperature, with multiple trauma. With femoro-femoral cannulation performed under sonographic and echocardiographic guidance, extracorporeal life support was initiated using a minimally invasive extracorporeal circulation system. Perfusing rhythm was restored at 28°C. During rewarming on the mobile circuit, trauma surveys were completed and the treatment initiated. Normothermic weaning was successful on the first attempt, trauma surgery was completed and the patient survived neurologically intact. For extracorporeal resuscitation from hypothermic arrest, minimally invasive extracorporeal circulation offers all the advantages of conventional cardiopulmonary bypass and extracorporeal membrane oxygenation systems without their shortcomings.
Resumo:
The Texas Bioterrorism Continuing Education Consortium (BCE) provided National Disaster Life Support (NDLS) training courses throughout the state of Texas in 2005, to help improve knowledge and skills pertaining to bioterrorism and other public health emergencies. The NDLS training courses include curriculum in Basic Disaster Life Support (BDLS) and Core Disaster Life Support (CDLS). A course evaluation which included items assessing ability and willingness of training participants, role of responders, and other variables was mailed to all NDLS participants who provided contact information. An analysis was conducted to determine whether the survey respondents participated in the Hurricanes Katrina and/or Rita relief efforts, as well as to evaluate the impact of the NDLS training courses on the participant's ability and willingness to respond during a disaster. The study population (n = 2150) consisted mostly of nurses (50%) (n=1074). A chi-square test of analysis indicated the following results. Among the survey respondents who took the CDLS course, there was no statically significant difference by occupation pertaining to ability or willingness to respond (x2 [df = 5] = 4.02, p= 0.546); (x2 [df = 5] = 2.45, p = .783). However, there was a statistically significant difference among those respondents who took the BDLS course with respect to ability, and a slightly significant difference with respect to willingness (x2 [df = 5] = 13.35, p = .020 and (x2 = [df = 5] = 10.299, p = .067). These findings are similar to previous studies assessing willingness to respond to a disaster.^ A second analysis was conducted with these survey data to evaluate the implications for disaster response training for the NDLS courses. Results indicated that the majority of disaster responders served in the role for which they were professionally trained (Physicians=68%; Nurses = 50.4%). Nurses, EMT, and Fire professionals served in multiple roles. These results suggest the importance of developing training programs that will prepare professionals to serve in multiple roles. The development of standardized evaluation methods would fill an important gap in assessing impact of national training programs. ^
Resumo:
La tesis que se presenta tiene como propósito la construcción automática de ontologías a partir de textos, enmarcándose en el área denominada Ontology Learning. Esta disciplina tiene como objetivo automatizar la elaboración de modelos de dominio a partir de fuentes información estructurada o no estructurada, y tuvo su origen con el comienzo del milenio, a raíz del crecimiento exponencial del volumen de información accesible en Internet. Debido a que la mayoría de información se presenta en la web en forma de texto, el aprendizaje automático de ontologías se ha centrado en el análisis de este tipo de fuente, nutriéndose a lo largo de los años de técnicas muy diversas provenientes de áreas como la Recuperación de Información, Extracción de Información, Sumarización y, en general, de áreas relacionadas con el procesamiento del lenguaje natural. La principal contribución de esta tesis consiste en que, a diferencia de la mayoría de las técnicas actuales, el método que se propone no analiza la estructura sintáctica superficial del lenguaje, sino que estudia su nivel semántico profundo. Su objetivo, por tanto, es tratar de deducir el modelo del dominio a partir de la forma con la que se articulan los significados de las oraciones en lenguaje natural. Debido a que el nivel semántico profundo es independiente de la lengua, el método permitirá operar en escenarios multilingües, en los que es necesario combinar información proveniente de textos en diferentes idiomas. Para acceder a este nivel del lenguaje, el método utiliza el modelo de las interlinguas. Estos formalismos, provenientes del área de la traducción automática, permiten representar el significado de las oraciones de forma independiente de la lengua. Se utilizará en concreto UNL (Universal Networking Language), considerado como la única interlingua de propósito general que está normalizada. La aproximación utilizada en esta tesis supone la continuación de trabajos previos realizados tanto por su autor como por el equipo de investigación del que forma parte, en los que se estudió cómo utilizar el modelo de las interlinguas en las áreas de extracción y recuperación de información multilingüe. Básicamente, el procedimiento definido en el método trata de identificar, en la representación UNL de los textos, ciertas regularidades que permiten deducir las piezas de la ontología del dominio. Debido a que UNL es un formalismo basado en redes semánticas, estas regularidades se presentan en forma de grafos, generalizándose en estructuras denominadas patrones lingüísticos. Por otra parte, UNL aún conserva ciertos mecanismos de cohesión del discurso procedentes de los lenguajes naturales, como el fenómeno de la anáfora. Con el fin de aumentar la efectividad en la comprensión de las expresiones, el método provee, como otra contribución relevante, la definición de un algoritmo para la resolución de la anáfora pronominal circunscrita al modelo de la interlingua, limitada al caso de pronombres personales de tercera persona cuando su antecedente es un nombre propio. El método propuesto se sustenta en la definición de un marco formal, que ha debido elaborarse adaptando ciertas definiciones provenientes de la teoría de grafos e incorporando otras nuevas, con el objetivo de ubicar las nociones de expresión UNL, patrón lingüístico y las operaciones de encaje de patrones, que son la base de los procesos del método. Tanto el marco formal como todos los procesos que define el método se han implementado con el fin de realizar la experimentación, aplicándose sobre un artículo de la colección EOLSS “Encyclopedia of Life Support Systems” de la UNESCO. ABSTRACT The purpose of this thesis is the automatic construction of ontologies from texts. This thesis is set within the area of Ontology Learning. This discipline aims to automatize domain models from structured or unstructured information sources, and had its origin with the beginning of the millennium, as a result of the exponential growth in the volume of information accessible on the Internet. Since most information is presented on the web in the form of text, the automatic ontology learning is focused on the analysis of this type of source, nourished over the years by very different techniques from areas such as Information Retrieval, Information Extraction, Summarization and, in general, by areas related to natural language processing. The main contribution of this thesis consists of, in contrast with the majority of current techniques, the fact that the method proposed does not analyze the syntactic surface structure of the language, but explores his deep semantic level. Its objective, therefore, is trying to infer the domain model from the way the meanings of the sentences are articulated in natural language. Since the deep semantic level does not depend on the language, the method will allow to operate in multilingual scenarios, where it is necessary to combine information from texts in different languages. To access to this level of the language, the method uses the interlingua model. These formalisms, coming from the area of machine translation, allow to represent the meaning of the sentences independently of the language. In this particular case, UNL (Universal Networking Language) will be used, which considered to be the only interlingua of general purpose that is standardized. The approach used in this thesis corresponds to the continuation of previous works carried out both by the author of this thesis and by the research group of which he is part, in which it is studied how to use the interlingua model in the areas of multilingual information extraction and retrieval. Basically, the procedure defined in the method tries to identify certain regularities at the UNL representation of texts that allow the deduction of the parts of the ontology of the domain. Since UNL is a formalism based on semantic networks, these regularities are presented in the form of graphs, generalizing in structures called linguistic patterns. On the other hand, UNL still preserves certain mechanisms of discourse cohesion from natural languages, such as the phenomenon of the anaphora. In order to increase the effectiveness in the understanding of expressions, the method provides, as another significant contribution, the definition of an algorithm for the resolution of pronominal anaphora limited to the model of the interlingua, in the case of third person personal pronouns when its antecedent is a proper noun. The proposed method is based on the definition of a formal framework, adapting some definitions from Graph Theory and incorporating new ones, in order to locate the notions of UNL expression and linguistic pattern, as well as the operations of pattern matching, which are the basis of the method processes. Both the formal framework and all the processes that define the method have been implemented in order to carry out the experimentation, applying on an article of the "Encyclopedia of Life Support Systems" of the UNESCO-EOLSS collection.