978 resultados para Laser Doppler flowmetry


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective
We examined the effect of a 14-month progressive resistance training (PRT) program on endothelial function in both a supervised training (Center) group and non-supervised training (Home) group of patients with type 2 diabetes. We studied 28 men and women with type 2 diabetes who participated in a 14-month PRT involving an initial 2-month supervised program and a 12-month maintenance program.

Methods
Endothelial function testing was performed through laser doppler flow responses in the skin microcirculation to iontophoresis of acetylcholine (ACh) and sodium nitroprusside (NaNP) and doses of 4, 8 and 16 mC were used. Measurements of vascular response (VR), HbA1c, weight and blood pressure were performed at 0, 2 and 14 months.

Results
VR to ACh and NaNP was significantly increased at 14 months compared with baseline in both the Center and Home groups. However, no between-group differences were observed. A significant correlation was observed between HbA1c and VR to ACh at baseline and 8 weeks using 8 mC dose of ACh. There was a strong correlation between HbA1c at baseline and VR at 14 months using all three doses of ACh (4 mC:r = −0.546, p = 0.003, 8 mC:r = −0.470, p = 0.002, 16 mC:r = −0.547, p = 0.006).

Conclusions/interpretation
Endothelial function is improved following 14 months of PRT in type 2 diabetes both in a supervised and non-supervised program. Strong correlations with HbA1c including initial HbA1c levels suggest that glycemic control may be an important factor in long-term regulation of endothelial function.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The construction of tissue-engineered parts such as heart valves and arteries requires more than just the seeding of cells onto a biocompatible/biodegradable polymeric scaffold. It is essential that the functionality and mechanical integrity of the cell-seeded scaffold be investigated in vitro prior to in vivo implantation. The correct hemodynamic conditioning would lead to the development of tissues with enhanced mechanical strength and cell viability. Therefore, a bioreactor that can simulate physiological conditions would play an important role in the preparation of tissue-engineered constructs. In this article, we present and discuss the design concepts and criteria, as well as the development, of a multifunctional bioreactor for tissue culture in vitro. The system developed is compact and easily housed in an incubator to maintain sterility of the construct. Moreover, the proposed bioreactor, in addition to mimicking in vivo conditions, is highly flexible, allowing different types of constructs to be exposed to various physiological flow conditions. Initial verification of the hemodynamic parameters using Laser doppler anemometry indicated that the bioreactor performed well and produced the correct physiological conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Avaliar as características antropométricas, a morbidade e mortalidade de recém-nascidos (RN) prematuros nascidos vivos de mães hipertensas em função da presença ou não de diástole zero (DZ) ou reversa (DR) na doplervelocimetria arterial umbilical. MÉTODOS: Estudo prospectivo, envolvendo RN prematuros nascidos vivos de gestantes hipertensas, com idade gestacional entre 25 e 33 semanas, submetidas à doplervelocimetria da artéria umbilical nos 5 dias que antecederam o parto, realizado no Hospital do Distrito Federal, entre 1º de novembro de 2009 e 31 de outubro de 2010. Os RN foram estratificados em dois grupos, conforme o resultado da doplervelocimetria da artéria umbilical: Gdz/dr=presença de diástole zero (DZ) ou diástole reversa (DR) e Gn=doplervelocimetria normal. Medidas antropométricas ao nascimento, morbidades e mortalidade neonatal foram comparadas entre os dois grupos. RESULTADOS: Foram incluídos 92 RN, assim distribuídos: Gdz/dr=52 RN e Gn=40 RN. No Gdz/dr a incidência de RN pequenos para idade gestacional foi significativamente maior, com risco relativo de 2,5 (IC95% 1,7‒3,7). No grupo Gdz/dr os RN permaneceram mais tempo em ventilação mecânica mediana 2 (0‒28) e no Gn mediana 0,5 (0‒25), p=0,03. A necessidade de oxigênio aos 28 dias de vida foi maior no Gdz/dr do que no Gn (33 versus10%; p=0,01). A mortalidade neonatal foi maior em Gdz/dr do que em Gn (36 versus 10%; p=0,03; com risco relativo de 1,6; IC95% 1,2 - 2,2). Nessa amostra a regressão logística mostrou que a cada 100 gramas a menos de peso ao nascer no Gdz/dr a chance de óbito aumentou 6,7 vezes (IC95% 2,0 - 11,3; p<0,01). CONCLUSÃO: em RN prematuros de mães hipertensas com alteração na doplervelocimetria da artéria umbilical a restrição do crescimento intrauterino é frequente e o prognóstico neonatal pior, sendo elevado o risco de óbito relacionado ao peso ao nascimento.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diese Arbeit beschreibt eine wesentliche Weiterentwicklung des Titan:Saphir-Lasersystems der Arbeitsgruppe LARISSA am Institut für Physik der Johannes Gutenberg-Universität Mainz und dessen Anwendung im Bereich der Resonanzionisationsspektroskopie. Die Entwicklungsarbeiten am Lasersystem umfassten drei Aspekte: die Erhöhung der Ausgangsleistung der vorhandenen Titan:Saphir-Laser um einen Faktor zwei, um damit für den vorgesehenen Einsatz an resonanten Laserionenquellen an ISOL-Einrichtungen optimale Voraussetzungen zu schaffen. Des Weiteren wurden zwei spezielle angepasste Titan:Saphir-Laser entwickelt: Das Lasersystem wurde damit um einen von 700 nm - 950 nm kontinuierlich abstimmbaren Titan:Saphir-Laser sowie einen geseedeten Titan:Saphir-Laser mit einer Linienbreite von nur 20 MHz (im Vergleich zu 3 GHz der konventionellen Laser) erweitert. Die Leistungsfähigkeit des neuen Lasersystems wurde durch Resonanzionisationsspektroskopie hochangeregter atomarer Zustände in Gold und Technetium demonstriert. Aus den gemessenen Energielagen konnte über die Rydberg-Ritz-Formel das Ionisationspotential von Gold bestätigt werden und das von Technetium erstmals mit hoher Präzision bestimmt werden. Mit dem geseedeten Titan:Saphir-Laser wurde dopplerfreie Zwei-Photonen-Spektroskopie innerhalb eines heißen Ofens demonstriert. Bei spektroskopischen Untersuchungen mit dieser Methode an Siliziumisotopen konnte sowohl die Hyperfeinstruktur als auch die Isotopieverschiebung bei einer Breite der Resonanzen von etwa 90 MHz klar aufgelöst werden.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fine powders commonly have poor flowability and dispersibility due to interparticle adhesion that leads to formation of agglomerates. Knowing about adhesion in particle collectives is indispensable to gain a deeper fundamental understanding of particle behavior in powders. Especially in pharmaceutical industry a control of adhesion forces in powders is mandatory to improve the performance of inhalation products. Typically the size of inhalable particles is in the range of 1 - 5 µm. In this thesis, a new method was developed to measure adhesion forces of particles as an alternative to the established colloidal probe and centrifuge technique, which are both experimentally demanding, time consuming and of limited practical applicability. The new method is based on detachment of individual particles from a surface due to their inertia. The required acceleration in the order of 500 000 g is provided by a Hopkinson bar shock excitation system and measured via laser vibrometry. Particle detachment events are detected on-line by optical video microscopy. Subsequent automated data evaluation allows obtaining a statistical distribution of particle adhesion forces. To validate the new method, adhesion forces for ensembles of single polystyrene and silica microspheres on a polystyrene coated steel surface were measured under ambient conditions. It was possible to investigate more than 150 individual particles in one experiment and obtain adhesion values of particles in a diameter range of 3 - 13 µm. This enables a statistical evaluation while measuring effort and time are considerably lower compared to the established techniques. Measured adhesion forces of smaller particles agreed well with values from colloidal probe measurements and theoretical predictions. However, for the larger particles a stronger increase of adhesion with diameter was observed. This discrepancy might be induced by surface roughness and heterogeneity that influence small and large particles differently. By measuring adhesion forces of corrugated dextran particles with sizes down to 2 µm it was demonstrated that the Hopkinson bar method can be used to characterize more complex sample systems as well. Thus, the new device will be applicable to study a broad variety of different particle-surface combinations on a routine basis, including strongly cohesive powders like pharmaceutical drugs for inhalation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The round window placement of a floating mass transducer (FMT) is a new approach for coupling an implantable hearing system to the cochlea. We evaluated the vibration transfer to the cochlear fluids of an FMT placed at the round window (rwFMT) with special attention to the role of bone conduction. A posterior tympanotomy was performed on eleven ears of seven human whole head specimens. Several rwFMT setups were examined using laser Doppler vibrometry measurements at the stapes and the promontory. In three ears, the vibrations of a bone anchored hearing aid (BAHA) and an FMT fixed to the promontory (pFMT) were compared to explore the role of bone conduction. Vibration transmission to the measuring point at the stapes was best when the rwFMT was perpendicularly placed in the round window and underlayed with connective tissue. Fixation of the rwFMT to the round window exhibited significantly lower vibration transmission. Although measurable, bone conduction from the pFMT was much lower than that of the BAHA. Our results suggest that the rwFMT does not act as a small bone anchored hearing aid, but instead, acts as a direct vibratory stimulator of the round window membrane.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Sepsis may impair mitochondrial utilization of oxygen. Since hepatic dysfunction is a hallmark of sepsis, we hypothesized that the liver is more susceptible to mitochondrial dysfunction than the peripheral tissues, such as the skeletal muscle. We studied the effect of prolonged endotoxin infusion on liver, muscle and kidney mitochondrial respiration and on hepatosplanchnic oxygen transport and microcirculation in pigs. METHODS: 20 anesthetized pigs were randomized to receive endotoxin or saline infusion for 24 hours. Muscle, liver and kidney mitochondrial respiration was assessed. Cardiac output (thermodilution), carotid, superior mesenteric and kidney arterial, portal venous (ultrasound Doppler) and microcirculatory blood flow (laser Doppler) were measured, and systemic and regional oxygen transport and lactate exchange were calculated. RESULTS: Endotoxin infusion induced hyperdynamic shock and impaired the glutamate- and succinate-dependent mitochondrial respiratory control ratio (RCR) in the liver (glutamate: endotoxemia: median [range] 2.8 [2.3-3.8] vs. controls: 5.3 [3.8-7.0]; p<0.001; succinate: endotoxemia: 2.9 [1.9-4.3] vs. controls: 3.9 [2.6-6.3] p=0.003). While the ADP:O ratio was reduced with both substrates, maximal ATP production was impaired only in the succinate-dependent respiration. Hepatic oxygen consumption and extraction, and liver surface laser Doppler blood flow remained unchanged. Glutamate-dependent respiration in the muscle and kidney was unaffected. CONCLUSIONS: Endotoxemia reduces the efficiency of hepatic but neither skeletal muscle nor kidney mitochondrial respiration, independent of regional and microcirculatory blood flow changes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Low cardiac output impairs the hepatic arterial buffer response (HABR). Whether this is due to low abdominal blood flow per se is not known. Dobutamine is commonly used to increase cardiac output, and it may further modify hepatosplanchnic and renal vasoregulation. We assessed the effects of isolated abdominal aortic blood flow changes and dobutamine on hepatosplanchnic and renal blood flow. Twenty-five anesthetized pigs with an abdominal aorto-aortic shunt were randomized to 2 control groups [zero (n = 6) and minimal (n = 6) shunt flow], and 2 groups with 50% reduction of abdominal blood flow and either subsequent increased abdominal blood flow by shunt reduction (n = 6) or dobutamine infusion at 5 and 10 microg kg(-1) min(-1) with constant shunt flow (n = 7). Regional (ultrasound) and local (laser Doppler) intra-abdominal blood flows were measured. The HABR was assessed during acute portal vein occlusion. Sustained low abdominal blood flow, by means of shunt activation, decreased liver, gut, and kidney blood flow similarly and reduced local microcirculatory blood flow in the jejunum. Shunt flow reduction partially restored regional blood flows but not jejunal microcirculatory blood flow. Low-but not high-dose dobutamine increased gut and celiac trunk flow whereas hepatic artery and renal blood flows remained unchanged. Neither intervention altered local blood flows. The HABR was not abolished during sustained low abdominal blood flow despite substantially reduced hepatic arterial blood flow and was not modified by dobutamine. Low-but not high-dose dobutamine redistributes blood flow toward the gut and celiac trunk. The jejunal microcirculatory flow, once impaired, is difficult to restore.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To investigate whether intermittent pneumatic compression (IPC) augments skin blood flow through transient suspension of local vasoregulation, the veno-arteriolar response (VAR), in healthy controls and in patients with peripheral arterial disease (PAD). METHODS: Nineteen healthy limbs and twenty-two limbs with PAD were examined. To assess VAR, skin blood flow (SBF) was measured using laser Doppler fluxmetry in the horizontal and sitting positions and was defined as percentage change with postural alteration [(horizontal SBF--sitting SBF)/horizontal SBF x 100]. On IPC application to the foot, the calf, or both, SBF was measured with laser Doppler fluxmetry, the probe being attached to the pulp of the big toe. RESULTS: Baseline VAR was higher in the controls 63.8 +/- 6.4% than in patients with PAD (31.7 +/- 13.4%, P = .0162). In both groups SBF was significantly higher with IPC than at rest (P < .0001). A higher percentage increase with IPC was demonstrated in the controls (242 +/- 85% to 788 +/- 318%) than in subjects with PAD, for each one of the three different IPC modes investigated (98 +/- 33% to 275 +/- 72%) with IPC was demonstrated. The SBF enhancement with IPC correlated with VAR for all three compression modes (r = 0.58, P = .002 for calf compression, r = 0.65, P < .0001 for foot compression alone, and r = 0.64, P = .0002 for combined foot and calf compression). CONCLUSION: The integrity of the veno-arteriolar response correlates with the level of skin blood flow augmentation generated with intermittent pneumatic compression, indicating that this may be associated with a transient suspension of the autoregulatory vasoconstriction both in healthy controls and in patients with PAD.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For a fluid dynamics experimental flow measurement technique, particle image velocimetry (PIV) provides significant advantages over other measurement techniques in its field. In contrast to temperature and pressure based probe measurements or other laser diagnostic techniques including laser Doppler velocimetry (LDV) and phase Doppler particle analysis (PDPA), PIV is unique due to its whole field measurement capability, non-intrusive nature, and ability to collect a vast amount of experimental data in a short time frame providing both quantitative and qualitative insight. These properties make PIV a desirable measurement technique for studies encompassing a broad range of fluid dynamics applications. However, as an optical measurement technique, PIV also requires a substantial technical understanding and application experience to acquire consistent, reliable results. Both a technical understanding of particle image velocimetry and practical application experience are gained by applying a planar PIV system at Michigan Technological University’s Combustion Science Exploration Laboratory (CSEL) and Alternative Fuels Combustion Laboratory (AFCL). Here a PIV system was applied to non-reacting and reacting gaseous environments to make two component planar PIV as well as three component stereographic PIV flow field velocity measurements in conjunction with chemiluminescence imaging in the case of reacting flows. This thesis outlines near surface flow field characteristics in a tumble strip lined channel, three component velocity profiles of non-reacting and reacting swirled flow in a swirl stabilized lean condition premixed/prevaporized-fuel model gas turbine combustor operating on methane at 5-7 kW, and two component planar PIV measurements characterizing the AFCL’s 1.1 liter closed combustion chamber under dual fan driven turbulent mixing flow.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Reperfusion injury is insufficiently addressed in current clinical management of acute limb ischemia. Controlled reperfusion carries an enormous clinical potential and was tested in a new reality-driven rodent model. METHODS AND RESULTS: Acute hind-limb ischemia was induced in Wistar rats and maintained for 4 hours. Unlike previous tourniquets models, femoral vessels were surgically prepared to facilitate controlled reperfusion and to prevent venous stasis. Rats were randomized into an experimental group (n=7), in which limbs were selectively perfused with a cooled isotone heparin solution at a limited flow rate before blood flow was restored, and a conventional group (n=7; uncontrolled blood reperfusion). Rats were killed 4 hours after blood reperfusion. Nonischemic limbs served as controls. Ischemia/reperfusion injury was significant in both groups; total wet-to-dry ratio was 159+/-44% of normal (P=0.016), whereas muscle viability and contraction force were reduced to 65+/-13% (P=0.016) and 45+/-34% (P=0.045), respectively. Controlled reperfusion, however, attenuated reperfusion injury significantly. Tissue edema was less pronounced (132+/-16% versus 185+/-42%; P=0.011) and muscle viability (74+/-11% versus 57+/-9%; P=0.004) and contraction force (68+/-40% versus 26+/-7%; P=0.045) were better preserved than after uncontrolled reperfusion. Moreover, subsequent blood circulation as assessed by laser Doppler recovered completely after controlled reperfusion but stayed durably impaired after uncontrolled reperfusion (P=0.027). CONCLUSIONS: Reperfusion injury was significantly alleviated by basic modifications of the initial reperfusion period in a new in vivo model of acute limb ischemia. With this model, systematic optimizations of according protocols may eventually translate into improved clinical management of acute limb ischemia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Direct revascularization of a bronchial artery has been proposed as a measure to alleviate the problem of bronchial ischemia after lung transplantation. To assess the effect of restoration of arterial blood flow to the transplanted bronchus, bronchial mucosal blood flow was measured in a model of modified unilateral lung transplantation in pigs. Laser Doppler velocimetry (LDV) and radioisotope studies using radio-labeled erythrocytes (RI) were used to measure blood flow at the donor main carina (DC) and upper lobe carina (DUC) after 3 h of reperfusion. The recipient carina was used as a reference point; values obtained by LDV and RI were expressed as percentage of blood flow at the recipient carina. Two groups of animals were studied. In group 1 (n = 6) standard unilateral transplantation was performed; in group 2 (n = 6) a left bronchial artery was reimplanted into the descending thoracic aorta of the recipient. No differences were observed between the two groups with respect to preoperative or postoperative gas exchange or hemodynamics. In group 1, bronchial blood flow at the DC was 37.6 +/- 2.2% (LDV) and 44.1 +/- 14.8% (RI) of reference blood flow. At the DUC, blood flow was 54.9 +/- 7.7% (LDV) and 61.6 +/- 25.7% (RI) of normal flow. In group 2, blood flow was increased at the DC as measured by LDV (55.3 +/- 17.1%; p less than 0.05) and by RI (60.8 +/- 25.3%; p less than 0.2). A similar increase was found at the DUC (LDV: 81.8 +/- 19.3%; p less than 0.05; RI: 88.6 +/- 31.0%; p less than 0.2). It is concluded that there is a significant gradient of blood flow from intra- to extrapulmonary airways after lung transplantation. Reimplantation of a bronchial artery results in significant improvement of graft bronchial blood flow. Restoration of bronchial perfusion to normal levels, however, cannot be achieved, suggesting a possible defect in the microcirculation of the donor airways.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A large number of studies utilize animal models to investigate therapeutic angiogenesis. However, the lack of a standardized experimental model leaves the comparison of different studies problematic. To establish a reference model of prolonged moderate tissue ischemia, we created unilateral hind limb ischemia in athymic rnu-rats by surgical excision of the femoral vessels. Blood flow of the limb was monitored for 60 days by laser Doppler imaging. Following a short postoperative period of substantially depressed perfusion, the animals showed a status of moderate hind limb ischemia from day 14 onwards. Thereafter, the perfusion remained at a constant level (55.5% of normal value) until the end of the observation period. Histopathological assessment of the ischemic musculature on postoperative days 28 and 60 showed essentially no inflammatory cell infiltrate or fibrosis. However, the mitochondrial activity and capillary-to-fiber ratio of the muscular tissue was reduced to 52.7% of normal, presenting with a significant weakness of the ischemic limb evidenced by a progressive decline in performance. Intramuscular injection of culture-expanded human endothelial progenitor cells (EPC) resulted in a significant increase in blood flow (82.0+/-3.5% of normal), capillary density (1.60+/-0.08/muscle fiber) and smooth muscle covered arterioles (8.0+/-0.6/high power field) in the ischemic hind limb as compared to controls (55.0+/-3.1%; 0.99+/-0.03; 5.0+/-0.2). In conclusion, chronic, moderate hind limb ischemia with consistently reduced perfusion levels persisting over a prolonged period can be established reliably in rnu athymic nude rats and is responsive to pro-angiogenic treatments such as EPC transplantation. This study provides a detailed protocol of a highly reproducible reference model to test novel therapeutic options for limb ischemia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Current evidence suggests that endothelial progenitor cells (EPC) contribute to ischemic tissue repair by both secretion of paracrine factors and incorporation into developing vessels. We tested the hypothesis that cell-free administration of paracrine factors secreted by cultured EPC may achieve an angiogenic effect equivalent to cell therapy. METHODOLOGY/PRINCIPAL FINDINGS: EPC-derived conditioned medium (EPC-CM) was obtained from culture expanded EPC subjected to 72 hours of hypoxia. In vitro, EPC-CM significantly inhibited apoptosis of mature endothelial cells and promoted angiogenesis in a rat aortic ring assay. The therapeutic potential of EPC-CM as compared to EPC transplantation was evaluated in a rat model of chronic hindlimb ischemia. Serial intramuscular injections of EPC-CM and EPC both significantly increased hindlimb blood flow assessed by laser Doppler (81.2+/-2.9% and 83.7+/-3.0% vs. 53.5+/-2.4% of normal, P<0.01) and improved muscle performance. A significantly increased capillary density (1.62+/-0.03 and 1.68+/-0.05/muscle fiber, P<0.05), enhanced vascular maturation (8.6+/-0.3 and 8.1+/-0.4/HPF, P<0.05) and muscle viability corroborated the findings of improved hindlimb perfusion and muscle function. Furthermore, EPC-CM transplantation stimulated the mobilization of bone marrow (BM)-derived EPC compared to control (678.7+/-44.1 vs. 340.0+/-29.1 CD34(+)/CD45(-) cells/1x10(5) mononuclear cells, P<0.05) and their recruitment to the ischemic muscles (5.9+/-0.7 vs. 2.6+/-0.4 CD34(+) cells/HPF, P<0.001) 3 days after the last injection. CONCLUSIONS/SIGNIFICANCE: Intramuscular injection of EPC-CM is as effective as cell transplantation for promoting tissue revascularization and functional recovery. Owing to the technical and practical limitations of cell therapy, cell free conditioned media may represent a potent alternative for therapeutic angiogenesis in ischemic cardiovascular diseases.