943 resultados para Laboratories diagnostic
Resumo:
OBJECTIVE: To access the incidence of diagnostic errors in the initial evaluation of children with cardiac murmurs. METHODS: We evaluated our 7-years of experience in a public pediatric cardiology outpatient clinic. Of 3692 patients who were sent to the hospital, 2603 presented with a heart murmur and were investigated. Patients for whom a disagreement existed between the initial and final diagnoses were divided into the following 2 groups: G1 (n=17) with an initial diagnosis of an innocent murmur and a final diagnosis of cardiopathy, and G2 (n=161) with an initial diagnosis of cardiopathy and a final diagnosis of a normal heart. RESULTS: In G1, the great majority of patients had cardiac defects with mild hemodynamic repercussions, such as small ventricular septal defect and mild pulmonary stenosis. In G2, the great majority of structural defects were interventricular communication, atrial septal defect and pulmonary valve stenosis. CONCLUSION: A global analysis demonstrated that diagnostic error in the initial evaluation of children with cardiac murmurs is real, reaching approximately 6% of cases. The majority of these misdiagnoses were in patients with an initial diagnosis of cardiopathy, which was not confirmed through later complementary examinations. Clinical cardiovascular examination is an excellent resource in the evaluation of children suspected of having cardiopathy. Immediate outpatient discharge of children with an initial diagnosis of an innocent heart murmur seems to be a suitable approach.
Resumo:
El presente proyecto se plantea el siguiente problema de investigación:¿Cuál es la eficacia de los entornos virtuales de enseñanza para optimizar los aprendizajes de Química? Se sostiene la hipótesis de que los entornos virtuales de enseñanza, empleados como mediación instrumental, son eficaces para optimizar los aprendizajes de química, particularmente facilitando la vinculación y reversibilidad entre "mundo micro y macroscópico"; capacidad que usualmente sólo se atribuye al trabajo experimental de laboratorio. Los objetivos propuestos son: Determinar la eficacia de entornos virtuales de enseñanza, como mediaciones instrumentales, para optimizar los aprendizajes de química en estudiantes de ingeniería. Implementar un entrono virtual de enseñanza de química, diseñado como mediación instrumental y destinado a estudiantes de dos carreras de ingeniería del IUA. Evaluar el desarrollo y los resultados de la innovación introducida. Comparar los resultados de la innovación con los resultados de la enseñanza usual. Derivar conclusiones acerca de la eficacia de la innovación propuesta. Socializar el conocimiento producido en ámbitos científico-tecnológicos reconocidos. Se generará un aula virtual en plataforma Educativa y utilidzando el laboratorio de computación de la institución se buscará desarrollar laboratorios virtuales donde se propondrán actividades de simulación de trabajo experimental. Los resultados esperados son: - Un Aula Virtual que cumpla funciones análogas a las de un laboratorio experimental. - Información válida y confiable acerca de la eficacia de la misma como medio para optimizar los aprendizajes de química. - Publicaciones en ámbitos científico-tecnológicos reconocidos que sometan a juicio público la innovación y la investigación efectuadas. La importancia del proyecto radica principalmente en poner a prueba la eficacia de los entornos virtuales para optimizar los aprendizajes de química, analogando tareas usualmente limitadas al trabajo experimental de laboratorio. Su pertinencia apunta a un replanteo del curriculo de los cursos de Química para estudiantes de Ingeniería.
Resumo:
Gastrointestinal cancers, HCC, ectopeptidases, differential display, gasdermin-like
Resumo:
AbstractBackground:Myocardial perfusion scintigraphy (MPS) in patients not reaching 85% of the maximum predicted heart rate (MPHR) has reduced sensitivity.Objectives:In an attempt to maintain diagnostic sensitivity without losing functional exercise data, a new exercise and dipyridamole combined protocol (EDCP) was developed. Our aim was to evaluate the feasibility and safety of this protocol and to compare its diagnostic sensitivity against standard exercise and dipyridamole protocols.Methods:In patients not reaching a sufficient exercise (SE) test and with no contraindications, 0.56 mg/kg of dipyridamole were IV administered over 1 minute simultaneously with exercise, followed by 99mTc-MIBI injection.Results:Of 155 patients, 41 had MPS with EDCP, 47 had a SE test (≥ 85% MPHR) and 67 underwent the dipyridamole alone test (DIP). They all underwent coronary angiography within 3 months. The three stress methods for diagnosis of coronary lesions had their sensitivity compared. For stenosis ≥ 70%, EDCP yielded 97% sensitivity, SE 90% and DIP 95% (p = 0.43). For lesions ≥ 50%, the sensitivities were 94%, 88% and 95%, respectively (p = 0.35). Side effects of EDCP were present in only 12% of the patients, significantly less than with DIP (p < 0.001).Conclusions:The proposed combined protocol is a valid and safe method that yields adequate diagnostic sensitivity, keeping exercise prognostic information in patients unable to reach target heart rate, with fewer side effects than the DIP.
Resumo:
Data Mining, Vision Restoration, Treatment outcome prediction, Self-Organising-Map
Resumo:
AbstractBackground:Guidelines recommend that in suspected stable coronary artery disease (CAD), a clinical (non-invasive) evaluation should be performed before coronary angiography.Objective:We assessed the efficacy of patient selection for coronary angiography in suspected stable CAD.Methods:We prospectively selected consecutive patients without known CAD, referred to a high-volume tertiary center. Demographic characteristics, risk factors, symptoms and non-invasive test results were correlated to the presence of obstructive CAD. We estimated the CAD probability based on available clinical data and the incremental diagnostic value of previous non-invasive tests.Results:A total of 830 patients were included; median age was 61 years, 49.3% were males, 81% had hypertension and 35.5% were diabetics. Non-invasive tests were performed in 64.8% of the patients. At coronary angiography, 23.8% of the patients had obstructive CAD. The independent predictors for obstructive CAD were: male gender (odds ratio [OR], 3.95; confidence interval [CI] 95%, 2.70 - 5.77), age (OR for 5 years increment, 1.15; CI 95%, 1.06 - 1.26), diabetes (OR, 2.01; CI 95%, 1.40 - 2.90), dyslipidemia (OR, 2.02; CI 95%, 1.32 - 3.07), typical angina (OR, 2.92; CI 95%, 1.77 - 4.83) and previous non-invasive test (OR 1.54; CI 95% 1.05 - 2.27).Conclusions:In this study, less than a quarter of the patients referred for coronary angiography with suspected CAD had the diagnosis confirmed. A better clinical and non-invasive assessment is necessary, to improve the efficacy of patient selection for coronary angiography.
Resumo:
Preparations of simian SA11 maintained in different laboratories were compared with each other by polyacrylamide gel electrophoresis of genomic RNA. Differences in the migration of genome segments 4,5 and 7 allowed the classification of eight virus preparations into four electrophoretic types.
Resumo:
The unresolved issue of false-positive D-dimer results in the diagnostic workup of pulmonary embolism Pulmonary embolism (PE) remains a difficult diagnosis as it lacks specific symptoms and clinical signs. After the determination of the pretest PE probability by a validated clinical score, D-dimers (DD) is the initial blood test in the majority of patients whose probability is low or intermediate. The low specificity of DD results in a high number of false-positives that then require thoracic angio-CT. A new clinical decision rule, called the Pulmonary Embolism Rule-out criteria (PERC), identifies patients at such low risk that PE can be safely ruled-out without a DD test. Its safety has been confirmed in US emergency departments, but retrospective European studies showed that it would lead to 5-7% of undiagnosed PE. Alternative strategies are needed to reduce the proportion of false-positive DD results.
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently been introduced in diagnostic microbiology laboratories for the identification of bacterial and yeast strains isolated from clinical samples. In the present study, we prospectively compared MALDI-TOF MS to the conventional phenotypic method for the identification of routine isolates. Colonies were analyzed by MALDI-TOF MS either by direct deposition on the target plate or after a formic acid-acetonitrile extraction step if no valid result was initially obtained. Among 1,371 isolates identified by conventional methods, 1,278 (93.2%) were putatively identified to the species level by MALDI-TOF MS and 73 (5.3%) were identified to the genus level, but no reliable identification was obtained for 20 (1.5%). Among the 1,278 isolates identified to the species level by MALDI-TOF MS, 63 (4.9%) discordant results were initially identified. Most discordant results (42/63) were due to systematic database-related taxonomical differences, 14 were explained by poor discrimination of the MALDI-TOF MS spectra obtained, and 7 were due to errors in the initial conventional identification. An extraction step was required to obtain a valid MALDI-TOF MS identification for 25.6% of the 1,278 valid isolates. In conclusion, our results show that MALDI-TOF MS is a fast and reliable technique which has the potential to replace conventional phenotypic identification for most bacterial strains routinely isolated in clinical microbiology laboratories.