914 resultados para LENGTHS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The iron(II) complex [Fe(AMN(3)S(3)sarH)](ClO4)(3).3H(2)O (AMN(3)S(3)sarH = 8-ammonio-1-methyl-3,13,16-trithia-6,10,19-triazabicyclo[6.6.6]icosane) has been synthesized and characterized by single crystal structure and spectroscopic methods. The Fe(II)-S(thiaether) bond lengths are short, indicative of a large degree of metal-ligand orbital mixing (pi-acceptor character) of the thiaether ligand. The complex is stable to metal centred oxidation. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By spliced alignment of human DNA and transcript sequence data we constructed a data set of transcript-confirmed exons and introns from 2793 genes, 796 of which (28%) were seen to have multiple isoforms. We find that over one-third of human exons can translate in more than one frame, and that this is highly correlated with G+C content. Introns containing adenosine at donor site position +3 (A3), rather than guanosine (G3), are more common in low G+C regions, while the converse is true in high G+C regions. These two classes of introns are shown to have distinct lengths, consensus sequences and correlations among splice signals, leading to the hypothesis that A3 donor sites are associated with exon definition, and G3 donor sites with intron definition. Minor classes of introns, including GC-AG, U12-type GT-AG, weak, and putative AG-dependant introns are identified and characterized. Cassette exons are more prevalent in low G+C regions, while exon isoforms are more prevalent in high G+C regions. Cassette exon events outnumber other alternative events, while exon isoform events involve truncation twice as often as extension, and occur at acceptor sites twice as often as at donor sites. Alternative splicing is usually associated with weak splice signals, and in a majority of cases, preserves the coding frame. The reported characteristics of constitutive and alternative splice signals, and the hypotheses offered regarding alternative splicing and genome organization, have important implications for experimental research into RNA processing. The 'AltExtron' data sets are available at http://www.bit.uq.edu.au/altExtron/ and http://www.ebi.ac.uk/similar tothanaraj/altExtron/.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The flow field and the energy transport near thermoacoustic couples are simulated using a 2D full Navier-Stokes solver. The thermoacoustic couple plate is maintained at a constant temperature; plate lengths, which are short and long compared with the particle displacement lengths of the acoustic standing waves, are tested. Also investigated are the effects of plate spacing and the amplitude of the standing wave. Results are examined in the form of energy vectors, particle paths, and overall entropy generation rates. These show that a net heat-pumping effect appears only near the edges of thermoacoustic couple plates, within about a particle displacement distance from the ends. A heat-pumping effect can be seen even on the shortest plates tested when the plate spacing exceeds the thermal penetration depth. It is observed that energy dissipation near the plate increases quadratically as the plate spacing is reduced. The results also indicate that there may be a larger scale vortical motion outside the plates which disappears as the plate spacing is reduced. (C) 2002 Acoustical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is currently unclear whether it is the need to maintain metabolic efficiency, the need to keep skeletal loading below critical force levels, or simple mechanical factors that drive the walk-to-run (W R) and run-to-walk (R-W) transitions in human gait. Eighteen adults (9 males and 9 females) locomoted on an instrumented treadmill using their preferred gait. Each completed 2 ascending (W-R) and 2 descending (R-W) series of trials under three levels of loading (0%, 15% and 30% body weight). For each trial, participants locomoted for 60 s at each of 9 different speeds -4 speeds both above and below their preferred transition speed (PTS) plus their PTS. Evidence was sought for critical levels of key kinetic (maximum vertical force, impulse, first peak force, time to first peak force and maximum loading rate), energetic (oxygen consumption, transport cost) and mechanical variables (limb lengths, strength) predictive of the gait transition. Analyses suggested the kinetic variables of time to first peak force and loading rate as the most likely determinants of the W-R and R-W transitions. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Purpose Previous research regarding the symmetry of trans-tibial amputees has examined weight distribution and various gait parameters between prosthetic and sound limbs. However, to date, no known research has determined if asymmetry is present in the strength of the hip abductor muscles or if correlations exist between these categories of symmetry. The purpose of the present study was, therefore, to document asymmetry present in stance, strength and gait measures, and to determine the relationship between these variables. Method Twenty-three elderly, unilateral trans-tibial amputees stood on two adjacent forceplates whilst the weight distribution and standard deviation (SD) of the anterior-posterior and the medio-lateral centre of pressure excursion (COPE) under each limb was recorded during four 40 s trials: quiet stance (QS), with eyes open and eyes closed; and even stance (ES), with eyes open and eyes closed. Gait measures (velocity, cadence, step and stride lengths, stance:swing ratio and period of double support) over 10 m of fast, yet safe walking and measures of the strength of hip abductor muscles were also obtained by use of a stride analyser and a dynamometer, respectively. Results No significant differences were found between QS and ES measures. However, significantly more weight was taken on the sound limb than on the amputated limb. Notably, more anterior-posterior movement occurred under the sound limb than the amputated limb, with this becoming more apparent with the eyes closed. Movement in the medio-lateral direction was found to be the same between sides. No differences in muscle strength or gait measures between limbs were demonstrated. However. strong hip abductor muscles were correlated with increased weight-bearing on the amputated limb, improved gait parameters and reduced medio-lateral COPE under the amputated limb. Conclusions This research confirms the asymmetrical nature of amputee stance and demonstrates symmetry of strength and gait measures between limbs. The correlations between hip abductor muscle strength, weight distribution and gait measures illustrates the importance of pre- and postoperative training of these muscles. Copyright © 2002 Whurr Publishers Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has been argued that power-law time-to-failure fits for cumulative Benioff strain and an evolution in size-frequency statistics in the lead-up to large earthquakes are evidence that the crust behaves as a Critical Point (CP) system. If so, intermediate-term earthquake prediction is possible. However, this hypothesis has not been proven. If the crust does behave as a CP system, stress correlation lengths should grow in the lead-up to large events through the action of small to moderate ruptures and drop sharply once a large event occurs. However this evolution in stress correlation lengths cannot be observed directly. Here we show, using the lattice solid model to describe discontinuous elasto-dynamic systems subjected to shear and compression, that it is for possible correlation lengths to exhibit CP-type evolution. In the case of a granular system subjected to shear, this evolution occurs in the lead-up to the largest event and is accompanied by an increasing rate of moderate-sized events and power-law acceleration of Benioff strain release. In the case of an intact sample system subjected to compression, the evolution occurs only after a mature fracture system has developed. The results support the existence of a physical mechanism for intermediate-term earthquake forecasting and suggest this mechanism is fault-system dependent. This offers an explanation of why accelerating Benioff strain release is not observed prior to all large earthquakes. The results prove the existence of an underlying evolution in discontinuous elasto-dynamic, systems which is capable of providing a basis for forecasting catastrophic failure and earthquakes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The toadfishes Tetractenos hamiltoni and Torquigener pleurogramma (Tetraodontidae) possess occlusable yellow corneas. We examine the light transmission and location of the yellow/orange pigment throughout the cornea, the temporal properties of pigment migration and the ultrastructure of the pigmented processes during light- and dark-adaptation. Each species was dark-adapted during the day and light-adapted during the night and then exposed to either sun illumination or darkness for different lengths of time (0-70 min). Movement of corneal pigment could be induced in both species regardless of time of day or night. The pigment was able to migrate in a dorsal or ventral direction and changed from minimal to maximal pigmentation within 60 min. Three types of transmission curves were found with varying degrees of transmission in the 400-500 nm waveband, indicating that the pigment distribution is not uniform across the cornea; some areas of the cornea transmit near UV light, while others absorb blue light. The gradual change of the transmission characteristics in different areas of the cornea indicates the presence of different concentrations of a single type of pigment. Ultrastructural examination of the corneas showed that the layer containing the pigment is situated within the scleral cornea either surrounding (T. pleurogramma) or abutting (T. hamiltoni) an iridescent layer. Long sheet-like processes or chromatophores extending centrally from dorsal and ventral reservoirs are filled with pigment during the light-adapted state but empty in the dark-adapted state.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prediction equations of body composition based on measurements of whole-body bioelectrical impedance analysis (BIA) have been found to be population-specific. It was hypothesised that this may be, in part, due to differences in proportional limb lengths between ethnic or racial groups. As a preliminary to a survey of body composition in urban Nigerians using BIA, the relative limb lengths of the three major tribal groups (Hausa, Yoruba and Ibo) were determined. We found small (5-9%) but significantly longer limb lengths in Nigerians compared to a Caucasian population, but no significant differences between tribes. This implies that BIA prediction equations generated in a Caucasian population are inappropriate for use in a Nigerian population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate the ability of ultrasonography to estimate musactivity, we measured architectural parameters (pennation angles, fascicle lengths, and muscle thickness) of several human muscles (tibialis anterior, biceps brachii, brachialis, transversus abdominis, obliquus internus abdominis, and obliquus externus abdominis) during isometric contractions of from 0 to 100% maximal voluntary contraction (MVC). Concurrently, electromyographic (EMG) activity was measured with surface (tibialis anterior only) or fine-wire electrodes. Most architectural parameters changed markedly with contractions up to 30% MVC but changed little at higher levels of contraction. Thus, ultrasound imaging can be used to detect low levels of muscle activity but cannot discriminate between moderate and strong contractions. Ultrasound measures could reliably detect changes in EMG of as little as 4% MVC (biceps muscle thickness), 5% MVC (brachialis muscle thickness), or 9% MVC (tibialis anterior pennation angle). They were generally less sensitive to changes in abdominal muscle activity, but it was possible to reliably detect contractions of 12% MVC in transversus abdominis (muscle length) and 22% MVC in obliquus internus (muscle thickness). Obliquus externus abdominis thickness did not change consistently with muscle contraction, so ultrasound measures of thickness cannot be used to detect activity of this muscle. Ultrasound imaging can thus provide a non-invasive method of detecting isometric muscle contractions of certain individual muscles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The crystal structures of a pair of cis and trans isomers of the macrocyclic chloropentaamine title complex, as their tetrachlorozincate(II) salts, [CoCl(C11H27N5)][ZnCl4], are reported. The two distinct isomeric forms lead to significant variations in the Co-N bond lengths and, furthermore, hydrogen bonding between the complex ions is influenced by the folded (cis) or planar (trans) conformations of the coordinated ligand.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The 93 K X-ray crystal structure of tris(ethane-1,2-diamine)zinc(II) dinitrate is reported. As predicted by the spectroscopic studies of other workers, there is a reversible phase transition of the structure at low temperature. We have determined this temperature to be 143 K. The structure at this temperature and below resembles that of the room temperature structure, except the crystallographic D-3 symmetry of the complex cation (296 K) is lowered to C-2 ( below 144 K) by subtle changes in cation-anion hydrogen bonding. No change in the conformation of the cation or its bond lengths and angles was found.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A idade e o crescimento da cioba da costa central do Brasil foram estudados a partir de leituras de otólitos obtidos em amostragens mensais de desembarques comerciais, realizados nas cidades de Vitória e Vila Velha, entre os anos de 1998 e 1999. Através da análise do incremento marginal, foi verificada a formação anual de uma zona translúcida a partir do final do outono e durante o inverno. Foram observadas ciobas de 2 a 19 anos. Os comprimentos furcais (CF) médios retrocalculados variaram de 108 mm para idade 1 a 524 mm para idade 19. A equação de Von Bertalanffy ajustada aos CF médios retrocalculados foi CFt = 567,1 (1 - e -0.130 (t + 0.773)). A relação comprimento peso foi P = 2,68x10-5CF2.914, onde P = peso total em gramas. O crescimento é lento, com os incrementos anuais em peso aumentando gradativamente até atingir o máximo de 164 g entre as idades 7 e 8 anos. Os resultados deste trabalho indicam que a cioba tem longa expectativa de vida e baixas taxas de crescimento somático, características das espécies mais sensíveis à exploração pesqueira.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.