996 resultados para Konfiguraationhallinta (CM)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis and comparison of daily and yearly solar irradiation from the satellite CM SAF database and a set of 301 stations from the Spanish SIAR network is performed using data of 2010 and 2011. This analysis is completed with the comparison of the estimations of effective irradiation incident on three different tilted planes (fixed, two axis tracking, north-south hori- zontal axis) using irradiation from these two data sources. Finally, a new map of yearly values of irradiation both on the horizontal plane and on inclined planes is produced mixing both sources with geostatistical techniques (kriging with external drift, KED) The Mean Absolute Difference (MAD) between CM SAF and SIAR is approximately 4% for the irradiation on the horizontal plane and is comprised between 5% and 6% for the irradiation incident on the inclined planes. The MAD between KED and SIAR, and KED and CM SAF is approximately 3% for the irradiation on the horizontal plane and is comprised between 3% and 4% for the irradiation incident on the inclined planes. The methods have been implemented using free software, available as supplementary ma- terial, and the data sources are freely available without restrictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis and comparison of daily and yearly solar irradiation from the satellite CM SAF database and a set of 301 stations from the Spanish SIAR network is performed using data of 2010 and 2011. This analysis is completed with the comparison of the estimations of effective irradiation incident on three different tilted planes (fixed, two axis tracking, north-south hori- zontal axis) using irradiation from these two data sources. Finally, a new map of yearly values of irradiation both on the horizontal plane and on inclined planes is produced mixing both sources with geostatistical techniques (kriging with external drift, KED) The Mean Absolute Difference (MAD) between CM SAF and SIAR is approximately 4% for the irradiation on the horizontal plane and is comprised between 5% and 6% for the irradiation incident on the inclined planes. The MAD between KED and SIAR, and KED and CM SAF is approximately 3% for the irradiation on the horizontal plane and is comprised between 3% and 4% for the irradiation incident on the inclined planes. The methods have been implemented using free software, available as supplementary ma- terial, and the data sources are freely available without restrictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este proyecto, correspondiente a la Circunvalación de Lillo y conexión de las carreteras CM-3000, CM-3001, CM-3005, tiene por objeto la definición de una serie de soluciones al problema existente y la posterior elección de la alternativa que aúne las mejores cualidades globales mediante un método que valore razonadamente las diferentes características, así como la definición de la alternativa elegida

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica flexural dos instrumentos de níquel- titânio, Hyflex CM (Coltène, EUA) e TF Adaptive (SybronEndo, EUA) em diferentes situações experimentais. Todas as limas que foram selecionadas possuíam conicidade 0,04 e diâmetro de ponta 35. Utilizou-se um dispositivo desenvolvido especificamente para realizar o ensaio flexural dinâmico. Os instrumentos TF Adaptive foram divididos em 3 grupos de acordo com o ângulo de curvatura do ensaio: 45º, 60º e 90º e cada grupo subdividido em 2 subgrupos de acordo com o tipo de movimento: rotação contínua e Adaptive. Cada subgrupo era composto por 15 instrumentos TF Adaptive, totalizando 90 instrumentos. Quinze instrumentos Hyflex CM formavam o grupo 4, no ensaio com ângulo de curvatura 90 graus e rotação contínua. A simulação foi realizada em canais artificiais de aço com ângulo de 45, 60, 90 graus e raio 5m m. O número de ciclos e o tempo em segundos até a fratura foram tabulados e analisados. Entretanto, a fadiga cíclica flexural foi significante maior nos três grupos em movimento Adaptive. E as limas TF Adaptive em seu próprio movimento tiveram maior número de ciclos e tempo até a fratura quando comparadas as Hyflex CM no ensaio de 90 graus. Portanto, conclui-se que o sistema Adaptive (limas TF Adaptive + movimento Adaptive) foi mais seguro à resistência á fadiga flexural, e no ensaio de 90 graus o sistema Adaptive foi mais resistente quando comparado com as limas Hyflex CM no movimento de rotação contínua.