946 resultados para Isometric Axial Rotation
Resumo:
The integration of electric motors and industrial appliances such as pumps, fans, and compressors is rapidly increasing. For instance, the integration of an electric motor and a centrifugal pump provides cost savings and improved performance characteristics. Material cost savings are achieved when an electric motor is integrated into the shaft of a centrifugal pump, and the motor utilizes the bearings of the pump. This arrangement leads to a smaller configuration that occupies less floor space. The performance characteristics of a pump drive can be improved by using the variable-speed technology. This enables the full speed control of the drive and the absence of a mechanical gearbox and couplers. When using rotational speeds higher than those that can be directly achieved by the network frequency the structure of the rotor has to be mechanically durable. In this thesis the performance characteristics of an axial-flux solid-rotor-core induction motor are determined. The motor studied is a one-rotor-one-stator axial-flux induction motor, and thus, there is only one air-gap between the rotor and the stator. The motor was designed for higher rotational speeds, and therefore a good mechanical strength of the solid-rotor-core rotor is required to withstand the mechanical stresses. The construction of the rotor and the high rotational speeds together produce a feature, which is not typical of traditional induction motors: the dominating loss component of the motor is the rotor eddy current loss. In the case of a typical industrial induction motor instead the dominating loss component is the stator copper loss. In this thesis, several methods to decrease the rotor eddy current losses in the case of axial-flux induction motors are presented. A prototype motor with 45 kW output power at 6000 min-1 was designed and constructed for ascertaining the results obtained from the numerical FEM calculations. In general, this thesis concentrates on the methods for improving the electromagnetic properties of an axial-flux solid-rotor-core induction motor and examines the methods for decreasing the harmonic eddy currents of the rotor. The target is to improve the efficiency of the motor and to reach the efficiency standard of the present-day industrial induction motors equipped with laminated rotors.
Resumo:
The integrated system of design for manufacturing and assembly (DFMA) and internet based collaborative design are presented to support product design, manufacturing process, and assembly planning for axial eccentric oil-pump design. The presented system manages and schedules group oriented collaborative activities. The design guidelines of internet based collaborative design & DFMA are expressed. The components and the manufacturing stages of axial eccentric oil-pump are expressed in detail. The file formats of the presented system include the data types of collaborative design of the product, assembly design, assembly planning and assembly system design. Product design and assembly planning can be operated synchronously and intelligently and they are integrated under the condition of internet based collaborative design and DFMA. The technologies of collaborative modelling, collaborative manufacturing, and internet based collaborative assembly for the specific pump construction are developed. A seven-security level is presented to ensure the security of the internet based collaborative design system.
Resumo:
In distributed energy production, permanent magnet synchronous generators (PMSG) are often connected to the grid via frequency converters, such as voltage source line converters. The price of the converter may constitute a large part of the costs of a generating set. Some of the permanent magnet synchronous generators with converters and traditional separately excited synchronous generators couldbe replaced by direct-on-line (DOL) non-controlled PMSGs. Small directly networkconnected generators are likely to have large markets in the area of distributed electric energy generation. Typical prime movers could be windmills, watermills and internal combustion engines. DOL PMSGs could also be applied in island networks, such as ships and oil platforms. Also various back-up power generating systems could be carried out with DOL PMSGs. The benefits would be a lower priceof the generating set and the robustness and easy use of the system. The performance of DOL PMSGs is analyzed. The electricity distribution companies have regulations that constrain the design of the generators being connected to the grid. The general guidelines and recommendations are applied in the analysis. By analyzing the results produced by the simulation model for the permanent magnet machine, the guidelines for efficient damper winding parameters for DOL PMSGs are presented. The simulation model is used to simulate grid connections and load transients. The damper winding parameters are calculated by the finite element method (FEM) and determined from experimental measurements. Three-dimensional finite element analysis (3D FEA) is carried out. The results from the simulation model and 3D FEA are compared with practical measurements from two prototype axial flux permanent magnet generators provided with damper windings. The dimensioning of the damper winding parameters is case specific. The damper winding should be dimensioned based on the moment of inertia of the generating set. It is shown that the damper winding has optimal values to reach synchronous operation in the shortest period of time after transient operation. With optimal dimensioning, interferenceon the grid is minimized.
Resumo:
This work proposes the creation of a bioinspired electronic white cane for blind people using the whiskers principle for short-range navigation and exploration. Whiskers are coarse hairs of an animal's face that tells the animal that it has touched something using the nerves of the skin. In this work the raw data acquired from a low-size terrestrial LIDAR and a tri-axial accelerometer is converted into tactile information using several electromagnetic devices configured as a tactile belt. The LIDAR and the accelerometer are attached to the user’s forearm and connected with a wire to the control unit placed on the belt. Early validation experiments carried out in the laboratory are promising in terms of usability and description of the environment.
Resumo:
INTRODUCTION: We examined the power spectral changes of the compound muscle action potential (M wave) evoked during isometric contractions of increasing strength. METHODS: Surface electromyography (sEMG) of the vastus lateralis and medialis was recorded from 20 volunteers who performed 4-s step-wise isometric contractions of different intensities. A maximal M wave was elicited by a single stimulus to the femoral nerve and superimposed on the voluntary contractions. The spectral characteristics (Fmean and Fmedian) of sEMG and M-wave signals were calculated. RESULTS: M-wave spectral indicators increased systematically with contraction intensity up to 60% MVC and then leveled off at higher forces. Over the 10-60% MVC range, the increase in spectral indicators was 3 times higher for M waves (36%) than for sEMG (12%). CONCLUSIONS: The consistent increase in M-wave spectral characteristics with force is due to the fact that the number of motor units recruited by the superimposed supramaximal stimulus is approximately stable.
Resumo:
Endothelial cell release of nitric oxide (NO) is a defining characteristic of nondiseased arteries, and abnormal endothelial NO release is both a marker of early atherosclerosis and a predictor of its progression and future events. Healthy coronaries respond to endothelial-dependent stressors with vasodilatation and increased coronary blood flow (CBF), but those with endothelial dysfunction respond with paradoxical vasoconstriction and reduced CBF. Recently, coronary MRI and isometric handgrip exercise (IHE) were reported to noninvasively quantify coronary endothelial function (CEF). However, it is not known whether the coronary response to IHE is actually mediated by NO and/or whether it is reproducible over weeks. To determine the contribution of NO, we studied the coronary response to IHE before and during infusion of N(G)-monomethyl-l-arginine (l-NMMA, 0.3 mg·kg(-1)·min(-1)), a NO-synthase inhibitor, in healthy volunteers. For reproducibility, we performed two MRI-IHE studies ∼8 wk apart in healthy subjects and patients with coronary artery disease (CAD). Changes from rest to IHE in coronary cross-sectional area (%CSA) and diastolic CBF (%CBF) were quantified. l-NMMA completely blocked normal coronary vasodilation during IHE [%CSA, 12.9 ± 2.5 (mean ± SE, placebo) vs. -0.3 ± 1.6% (l-NMMA); P < 0.001] and significantly blunted the increase in flow [%CBF, 47.7 ± 6.4 (placebo) vs. 10.6 ± 4.6% (l-NMMA); P < 0.001]. MRI-IHE measures obtained weeks apart strongly correlated for CSA (P < 0.0001) and CBF (P < 0.01). In conclusion, the normal human coronary vasoactive response to IHE is primarily mediated by NO. This noninvasive, reproducible MRI-IHE exam of NO-mediated CEF promises to be useful for studying CAD pathogenesis in low-risk populations and for evaluating translational strategies designed to alter CAD in patients.
Resumo:
OBJECTIVE: Skeletal Muscle Biopsy is a minor surgical procedure for the diagnosis of different neuromuscular pathological conditions and has recently gained popularity also in the research field of age-related muscular modifications and sarcopenia. Few studies focused on the application of mini-invasive muscular biopsy in both normal and pathological conditions. The aim of our study was to describe a mini invasive ultrasound-guided skeletal muscular biopsy technique in complete spinal cord injured (SCI) patients and healthy controls with a tri-axial end-cut needle. PATIENTS AND METHODS: Skeletal muscle biopsies were collected from 6 chronic SCI patients and 3 healthy controls vastus lateralis muscle with a tri-axial end cut needle (Biopince© - Angiotech). Muscle samples were stained for ATPase to determine fibers composition, moreover, gene expression of cyclooxygenase-1 (COX-1) and prostaglandin E2 receptor has been analyzed by Real Time RT-PCR. RESULTS: All the procedures were perfomed easily without failures and complications. Control tissue was macroscopically thicker than SCI one. Control specimen displayed an equal distribution of type I and type II fibers, while SCI sample displayed a prevalence of type II fibers SCI specimen displayed a significant reduction in COX-1 gene expression. This mini-invasive approach was easy, accurate and with low complication rate in performing skeletal muscle biopsy in both SCI patients and controls. CONCLUSIONS: This technique could be useful in conditions in which the overall quantity of specimen required is small like for molecular biology analysis. For histological diagnostic purposes and/or conditions in which the original tissue is already pathologically modified, this technique should be integrated with more invasive techniques.
Resumo:
Les tâches nécessitant des manipulations et des transformations de figures géométriques et de formes, comme les tâches de rotation mentale, donnent lieu à des différences de performance entre hommes et femmes qui restent intrigantes. Plusieurs hypothèses ont été proposées pour expliquer ces différences. La plus récurrente porte sur les différences de stratégie globale vs locale utilisées pour traiter l'information. Bien que cette conjecture soit intéressante, elle reste difficile à opérationnaliser car elle englobe tous les mécanismes cognitifs (acquisition, conservation et récupération de l'information). Ce travail prend la forme d'un retour aux sources dans la mesure où il se base sur des recherches anciennes qui ont montré que les hommes perçoivent significativement mieux que les femmes la verticale et l'horizontale. Il teste l'hypothèse selon laquelle les hommes, comparativement aux femmes, présentent une plus forte indépendance au champ perceptif visuel et sont donc plus susceptibles d'utiliser la verticalité et l'horizontalité pour résoudre une tâche de rotation mentale. Une première série d'expériences s'est penchée sur la perception spatiale pour évaluer son impact sur la résolution d'une tâche impliquant la rotation mentale. Les résultats ont montré que seuls les hommes se référaient à la verticalité et à l'horizontalité pour résoudre la tâche. Une seconde série d'expériences ont investigué l'effet de la présence, ou absence, d'axes directionnels directement liés à une tâche de rotation mentale. Elles ont été menées également en environnement réel afin d'évaluer comment le déplacement actif ou passif, correspondant à un changement de perspective en lieu et place d'une rotation mentale, module la performance des hommes et des femmes. Les résultats n'ont pas mis en évidence de différence sexuelle. Notre hypothèse est vérifiée puisque c'est uniquement lorsque la tâche ne présente pas d'axes orthogonaux évidents mais implicites que seuls les hommes, plus indépendants au champ perceptif visuel que les femmes, utilisent la perception de la verticalité et de l'horizontalité pour améliorer leur compétence en rotation mentale. -- Tasks that require manipulation and transformation of geometric shapes and forms, like tasks of mental rotation and give rise to differences in performance between men and women, remain intriguing. Several hypotheses have been proposed to explain these differences. The most recurring hypothesis addresses differences in global versus local strategies for processing information. While this conjecture is interesting, it remains difficult to study because it encompasses all the cognitive mechanisms (acquisition, retention and output). This work returns to the sources, which are based on earlier research that shows that men are significantly better than women at perceiving verticality and horizontality. It tests the hypothesis according to which men, as compared to women, exhibit a greater independence on the perceptive visual field, and therefore are more susceptible to utilizing the verticality and the horizontality to solve a mental rotation task. A first set of experiments examined spatial perception in order to assess its impact on the resolution of a task involving mental rotation. The results showed that only men referred to the verticality and the horizontality to solve the task. A second series of experiments investigated the effect of a presence, or absence of directional axes directed tied to the task of mental rotation. They were also conducted in a real world environment to evaluate how the active or passive displacement, corresponding to a change in perspective instead of a mental rotation, modulates the performance of men and women. The results did not show sex differences. Our hypothesis is verified: it is only when the task presents no obvious, but implicit orthogonal axes that men, who exhibit a greater independence on the perceptive visual field than women, use the perception of verticality and horizontality to improve their competence in mental rotation.
Resumo:
MRI has become a major tool for the diagnosis of axial spondyloarthritis and provides objective signs based on which therapy can be initiated. In clinical practice, ASAS classification criteria are often applied for the diagnosis of spondyloarthritis at a pre-radiographic stage. However, MRI signs of spondyloarthritis as stated in ASAS criteria lack specificity, and can be encountered in a wide array of diagnoses, in particular degenerative and mechanical conditions. In this article, we will review the role of MRI in the diagnosis and classification of spondyloarthritis, general technical considerations, the elementary MRI signs of axial spondyloarthritis, as well as diagnostic pitfalls. We also provide a practical approach on how to avoid overdiagnosis of spondyloarthritis and to improve the diagnostic value of MRI.
Resumo:
AbstractObjective:To define the distal femur rotation pattern in a Brazilian population, correlating such pattern with the one suggested by the arthroplasty instruments, and analyzing the variability of each anatomic parameter.Materials and Methods:A series of 101 magnetic resonance imaging studies were evaluated in the period between April and June 2012. The epidemiological data collection was performed with the aid of the institution's computed imaging system, and the sample included 52 male and 49 female patients. The measurements were made in the axial plane, with subsequent correlation and triangulation with the other plans. The posterior condylar line was used as a reference for angle measurements. Subsequently, the anatomical and surgical transepicondylar axes and the anteroposterior trochlear line were specified. The angles between the reference line and the studied lines were calculated with the aid of the institution's software.Results:The mean angle between the anatomical transepicondylar axis and the posterior condylar line was found to be 6.89°, ranging from 0.25° to 12°. For the surgical transepicondylar axis, the mean value was 2.89°, ranging from –2.23° (internal rotation) to 7.86°, and for the axis perpendicular to the anteroposterior trochlear line, the mean value was 4.77°, ranging from –2.09° to 12.2°.Conclusion:The anatomical transepicondylar angle showed mean values corresponding to the measurement observed in the Caucasian population. The utilized instruments are appropriate, but no anatomical parameter proved to be steady enough to be used in isolation.
Resumo:
The goal of this study was to evaluate the feasibility of direct introduction of clay slurries in an inductively coupled plasma optical emission spectrometer with axial view configuration. Calibration was performed using a certified reference material with a mean particle size of 13 µm (IPT-42) and the analytical curve was applied for quantification of two others reference materials (IPT-28 and IPT-32) and four samples. It was demonstrated that the analytical curve thus obtained was not completely suitable for IPT-28 and samples due to different mineralogical phases determined by X-ray diffraction. After considering this effect, it was possible for most elements to obtain results in agreement with certified values or with values obtained by a conventional technique at a 95% confidence level. It was demonstrated that the ICP-OES with axial view configuration did not present any incompatibility with the direct introduction of a complex inorganic suspension.
Resumo:
Atropisomerism is a special kind of stereoisomeric relationship that arises from the freezing of a certain conformation of an organic molecule, associated with a high rotational barrier about a single covalent bond. Atropisomerism has been originally described in orto-functionalyzed biphenyl derivatives, but a lot of other organic functionalities can present this structural phenomenon, characterized by the presence of chiral properties in compounds that don't present classical stereogenic centers. Atropisomeric compounds, intermediates and catalysts have well-know importance in organic synthesis, but the influence of the axial chirality in substances able to modulate biological systems is still not very exploited in drug design and development. In this context, the present account describes the importance of this structural property in the medicinal chemistry of different classes of bioactive compounds or therapeutic agents, emphasizing how atropisomerism could affect the molecular recognition of a ligand or a prototype by the target bioreceptor.