948 resultados para Internal fixation in fractures
Resumo:
Dislocated compound fractures of the proximal humerus are often difficult to treat. The choice of treatment influences the final functional result. From 1984-1991 108 patients with dislocated compound fractures of the proximal humerus were operated with a T-plate osteosynthesis, retrospectively examined and classified according to the Neer-Classification. At an average follow up time of 5 years 72 patients had a clinical and radiological examination. 68% of these patients with 3-fragment fractures and 80% with 4-fragment fractures showed a modest to unsatisfactory result caused by fracture biology, imprecise fracture reduction or poor surgical procedure. Incorrect position of T-plates and inadequate material were distinguishable. The T-plate which was widely used in the late eighties for internal fixation has to be considered a failure for these particular types of fractures and should be limited for Collum chirurgicum fractures.
Resumo:
From August 91 to December 94, 20 external fixators were used for severely injured patients (avg. ISS 25.2). The fractures were essentially open book with or without lateral compression and vertical lesions. The indication for fixation was treatment of shock and stabilization in 8 cases, stabilization alone in 9 cases, and in 3 cases as complementary fixation after internal fixation of posterior lesions. The fixation of the pelvis was effective on the amount of blood loss. One acetabulum fracture required surgery, two patients had internal fixation for loss of reduction and two others for late pubic and posterior pain. The clinical results are good; they are more related to the severity of the initial lesion than to the mode of fixation or the quality of the reduction. No superficial sepsis or osteitis was observed in relation to the pins.
Resumo:
PURPOSE: To review, retrospectively, the possible causes of sub- or intertrochanteric fractures after screw fixation of intracapsular fractures of the proximal femur. METHODS: Eighty-four patients with an intracapsular fracture of proximal femur were operated between 1995 and 1998 by using three cannulated 6.25 mm screws. The screws were inserted in a triangular configuration, one screw in the upper part of the femoral neck and two screws in the inferior part. Between 1999 and 2001, we use two screws proximally and one screw distally. RESULTS: In the first series, two patients died within one week after operation. Sixty-four fractures healed without problems. Four patients developed an atrophic non-union; avascular necrosis of the femoral head was found in 11 patients. Three patients (3.6%) suffered a sub- and/or intertrochanteric fracture after a mean postoperative time of 30 days, in one case without obvious trauma. In all three cases surgical revision was necessary. Between 1999 and 2001 we did not observe any fracture after screwing. CONCLUSION: Two screws in the inferior part of the femoral neck create a stress riser in the subtrochanteric region, potentially inducing a fracture in the weakened bone. For internal fixation for proximal intracapsular femoral fracture only one screw must be inserted in the inferior part of neck.
Resumo:
PURPOSE OF THE STUDY: Fracture of the tibial pilon is a rare injury and its treatment remains difficult. The aim of this study was to report the complications and long term results of internal fixation using a technique which respects soft tissues and in which little material was used. MATERIAL: From 1985 to 1990, 48 patients with 51 fractures of the tibial pilon were treated by open reduction and internal fixation. All patients were submitted to a clinical and radiological review. METHODS: Both the Rüedi/Allgöwer and the AO-classification were used and determined by standard X-rays. Surgical procedure was performed with a 2 or 3 1/3 tube AO-plates and the peroneus was always fixed if fractured. Intraoperative reconstruction was analyzed. Subjective and objective scoring were used according to Olerud and Molander and the ankle arthritis was scored according to the classification determined by the SOFCOT in 1992. RESULTS: A minimal follow-up of 1 year for all cases was obtained, based on our own files. Thirty-eight patients (40 fractures) were evaluated after an average period of 88 months (56 to 124 months). Five patients developed cutaneous infection, three developed deep infection and four developed superficial skin necrosis. One aseptic non-union necessitated reoperation after 14 months. Two ankles had joint fusion after 19 and 25 months respectively due to severe arthritis. In six cases infectious and non-infectious complications led to surgical revision. According to the Olerud and Molander score, 15 per cent of the results were excellent, 45 per cent were good, 30 per cent were fair and 10 per cent poor. DISCUSSION: Literature shows a wide range of results following this surgical procedure. This is due to the difference in the type of trauma, classification system used, material used for the internal fixation and method of evaluation. The classification system of Rüedi and Allgöwer is the most commonly used but has a rather subjective tendency, especially between type II and type III. Treatment is difficult, especially for comminutive fractures associated with soft tissue damage. In this case, open reduction and internal fixation could increase iatrogenic lesions. For this reason surgical procedure can be delayed for several days, little material is used and soft tissue manipulation is reduced to minimum. In other study reports, the use of external fixation with or without minimal internal fixation have produced less complications without improving long term results. CONCLUSION: Analysis and comparison of study reports are difficult because of the absence of consensus in classification system and evaluation methods. The AO-classification, apparently the most objective, will probably be more and more used in the future. Treatment must be adapted to the bony lesion and soft tissue damage. Open reduction and internal fixation must be reserved for a specific group of lesion.
Resumo:
Osteoporosis is an increasing public health problem. The bisphophonates are the most useful treatment used through the world to prevent osteoporotic fractures. Their large prescription revealed an unpredictable side effect: the atypical fracture. These fractures appear in the subtrochanteric or diaphysal femoral proximal site, spontaneously or after a low trauma, and could be bilateral. X-rays shows a transversal or oblique fracture with a spur in the cortex and with a diffuse thickening of the cortical of the proximal femur. Expert's recommendations are current in progress to well understand and managed this problem. Here we report three cases of atypical femur fractures occurred in our Centre of bone diseases with some management and treatment propositions.
Resumo:
INTRODUCTION: Periprosthetic femur fracture (PFF) is a serious complication after total hip arthroplasty that can be treated using different internal fixation devices. However, the outcomes with curved non-locking plates with eccentric holes in this indication have not been reported previously. The objectives of this study were to determine: (1) the union rate; (2) the complication rate; (3) autonomy in a group of patients with a Vancouver type B PFF who were treated with this plate. HYPOTHESIS: Use of this plate results in a high union rate with minimal mechanical complications. MATERIALS AND METHODS: Forty-three patients with a mean age of 79 years±13 (41-98) who had undergone fixation of Vancouver type B PFF with this plate between 2002 and 2007 were included in the study. The time to union and Parker Mobility Score were evaluated. The revision-free survival (all causes) was calculated using Kaplan-Meier analysis. The average follow-up was 42 months±20 (16-90). RESULTS: Union was obtained in all patients in a mean of 2.4 months±0.6 (2-4). One patient had varus malunion of the femur. The Parker Mobility Score decreased from 5.93±1.94 (2-9) to 4.93±1.8 (1-9) (P=0.01). Two patients required a surgical revision: one for an infection after 4.5 years and one for stem loosening. The survival of the femoral stem 5 years after fracture fixation was 83.3%±12.6%. CONCLUSION: Use of a curved plate with eccentric holes for treating type B PFF led to a high union rate and a low number of fixation-related complications. However, PFF remains a serious complication of hip arthroplasty that is accompanied by high morbidity and mortality rates. LEVEL OF EVIDENCE: Retrospective study, level IV.
Resumo:
Background/Aim: The aim of this retrospective study was to evaluate the epidemiology, treatment, and complications of zygomatico-orbital complex (ZOC) and/or zygomatic arch (ZA) fractures either associated with other facial fractures or not over a 71-month period. Material and methods: This survey was performed in three hospitals of Ribeirao Preto in Sao Paulo, Brazil, from August 2002 to July 2008. The records of 1575 patients with facial trauma were reviewed. There were 140 cases of ZOC and ZA fractures either associated with other facial fractures or not. Data regarding gender, age, race, addictions, day of trauma, etiology, signs and symptoms, oral hygiene condition, day of initial evaluation, hospital admission, day of surgery, surgery approach, pattern of fractures, treatment performed, post-operative antibiotic therapy, day of hospital discharge, and post-operative complications were collected. The data were subjected to descriptive statistical analyses. Results: The most frequent fractures affected Caucasian men and occurred during the fourth decade of life. The most frequent etiology was traffic accident, and symptoms and signs included pain and edema. Type I fractures were the main injury observed, and the treatment of choice was always rigid internal fixation. Post-operative antibiotic therapy was solely employed when there was an indication. Complications were observed in 13.1% of the cases. Conclusions: The treatment protocol yielded suitable post-operative results and also showed success rates comparable to published data around the world.
Resumo:
This retrospective study evaluated the epidemiology, treatment and complications of mandibular fracture associated, or not associated, with other facial fractures, when the influence of the surgeon`s skill and preference for ally rigid internal fixation (RIF) system devices was minimized. The files of 700 patients with facial trauma were available, and 126 files were chosen for review. Data were collected regarding gender, age, race, date of trauma, date of surgery, addictions, etiology, signs and symptoms, fracture area, complications, treatment performed, date of hospital discharge.. and medication. 126 patients suffered mandibular fractures associated, or not, with other maxillofacial fractures, and a total of 201 mandibular fractures were found. The incidence of mandibular fractures was more prevalent in males, in Caucasians and during the third decade of life. The most common site was the condyle, followed by the mandibular body. The therapy applied was effective in handling this type of fracture and the Success rates were comparable with other published data.
Resumo:
The purpose of this study was to compare, by mechanical in vitro testing, a 2.0-mm system made with poly-L-DL-lactide acid with an analogue titanium-based system. Mandible replicas were used as a substrate and uniformly sectioned on the left mandibular angle. The 4-hole plates were adapted and stabilized passively in the same site in both groups using four screws, 6.0 mm long. During the resistance-to-load test, the force was applied perpendicular to the occlusal plane at three different points: first molar at the plated side; first molar at the contralateral side; and between the central incisors. At 1 mm of displacement, no statistically significant difference was found. At 2 mm displacement, a statistically significant difference was observed when an unfavourable fracture was simulated and the load was applied in the contralateral first molar and when a favourable fracture was simulated and the load was applied between the central incisors. At the failure displacement, a statistically significant difference was observed only when the favourable fracture was simulated and the load was applied on the first molar at the plated side. In conclusion, despite more failure, the poly-L-DL-lactic acid-based system was effective.
Resumo:
The Patino Formation sandstones, which crop out in Aregua neighborhood in Eastern Paraguay and show columnar joints near the contact zone with a nephelinite dyke, have as their main characteristics the high proportion of syntaxial quartz overgrowth and a porosity originated from different processes, initially by dissolution and later by partial filling and fracturing. Features like the presence of floating grains in the syntaxial cement, the transitional interpenetrative contact between the silica-rich cement and grains as well as the intense fracture porosity are strong indications that the cement has been formed by dissolution and reprecipitation of quartz from the framework under the effect of thermal expansion followed by rapid contraction. The increase of the silica-rich cement towards the dyke in association with the orthogonal disposition of the columns relative to dyke walls are indicative that the igneous body may represent the main heat source for the interstitial aqueous solutions previously existing in the sediments. At macroscopic scale, the increasing of internal tensions in the sandstones is responsible for the nucleation of polygons, leading to the individualization of prisms, which are interconnected by a system of joints, formed firstly on isotherm surfaces of low temperature and later on successive adjacent planes towards the dyke heat source.
Resumo:
This study compared the fixation of autogenous onlay bone grafts with cyanoacrylate glue (Super Bonder) and with titanium screws. Twenty rabbits underwent bilateral parietal ostectomies. Bone segments were fixed anteriorly to the resulting bone defect. In group I, the grafts were fixed with 4 min long, 1.5 mm diameter screws; in group II, adhesive was used. The animals were killed after 5, 15, 30, 60 and 120 days. Histomorphometric analysis was used to quantify the maintenance of the graft area. Discrete areas of inflammatory reaction were seen in both groups after 5 days and for group II after 15 days. After 30 days, new bone formation was seen at the interface of the grafts. After 120 days, the graft was incorporated into the host bed in group I and partially incorporated in group II. There was a significant statistical difference regarding the mean graft areas between 15 and 120 days (p < 0.001) and between fixation methods (p < 0.002). Fixation with adhesive promoted a significantly greater area of bone graft than screw fixation, independent of time period. The adhesive was biocompatible, presented similar stability to the screw and maintained the bone area, although there was a delay in graft incorporation.
Resumo:
Recent studies have evaluated many methods of internal fixation for sagittal split ramus osteotomy (SSRO), aiming to increase stability of the bone segments while minimizing condylar displacement. The purpose of this study was to evaluate, through biomechanical testing, the stability of the fixation comparing a specially designed bone plate to other two commonly used methods. Thirty hemimandibles were separated into three equal groups. All specimens received SSRO. In Group I the osteotomies were fixed with three 15 mm bicortical positional screws in an inverted-L pattern with an insertion angle of 90°. In Group II, fixation was carried out with a four-hole straight plate and four 6 mm monocortical screws. In Group III, fixation was performed with an adjustable sagittal plate and eight 6 mm monocortical screws. Hemimandibles were submitted to vertical compressive loads, by a mechanical testing unit. Averages and standard deviations were submitted to analysis of variance using the Tukey test with a 5% level of significance. Bicortical screws presented the greatest values of loading resistance. The adjustable miniplate demonstrated 60% lower resistance compared to bicortical screws. Group II presented on average 40% less resistant to the axial loading. © 2012 International Association of Oral and Maxillofacial Surgeons.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of the present study was to analyze the etiology, type and treatment employed in the orbito-zygomatic fractures (OZ). Also, postoperative complications are described and correlated with the type of treatment used. Fifty patients with OZ fractures were evaluated. Orbital fractures in which the zygomatic bone was not involved were excluded. Epidemiologic data and characteristics of treatment such as the type of material used for osteosynthesis, number of anatomical sites on which rigid internal fixation (RIF) was applied, surgical approaches and associated complications were recorded. The main causes of trauma were motorcycle and bicycle accidents, constituting 52% of the sample. The osteosynthesis system used was the 2.0 mm, except in four patients in whom the 1.5mm system was used for fixation at the infra-orbital rim. A total of 18% of the patients required reconstruction of the internal orbit and in all cases titanium mesh was used. 46% of the patients received RIF in three anatomical sites, most in the fronto-zygomatic suture, infra-orbital rim and zygomatic-maxillary buttress. The most frequent complication was paresthesia of the infra-orbital nerve (34 patients, 68%). Other findings were also discussed with the intent of better understanding the treatment of the OZ fractures.
Resumo:
Dislocated subcondylar fractures often require open reduction and internal fixation. This treatment modality results in better anatomy, early function, and facilitated physical therapy. Ideal stable fixation is obtained by use of two miniplates to control the tension zone in the sigmoid notch area and stabilize the posterior border region or, if there is not enough space, one stronger plate. That is most frequently achieved through extraoral approaches. Recently new instruments have facilitated the use of an intraoral approach, which is used usually with the aid of an endoscope. However, it is possible to perform the procedure without the endoscope if proper instruments and clinical mirrors for checking the posterior border reduction and fixation are used. A case of reduction and fixation of a medially dislocated condylar fracture is presented and discussed.