951 resultados para Inter-region power flow
Resumo:
The high penetration of distributed energy resources (DER) in distribution networks and the competitive environment of electricity markets impose the use of new approaches in several domains. The network cost allocation, traditionally used in transmission networks, should be adapted and used in the distribution networks considering the specifications of the connected resources. The main goal is to develop a fairer methodology trying to distribute the distribution network use costs to all players which are using the network in each period. In this paper, a model considering different type of costs (fixed, losses, and congestion costs) is proposed comprising the use of a large set of DER, namely distributed generation (DG), demand response (DR) of direct load control type, energy storage systems (ESS), and electric vehicles with capability of discharging energy to the network, which is known as vehicle-to-grid (V2G). The proposed model includes three distinct phases of operation. The first phase of the model consists in an economic dispatch based on an AC optimal power flow (AC-OPF); in the second phase Kirschen's and Bialek's tracing algorithms are used and compared to evaluate the impact of each resource in the network. Finally, the MW-mile method is used in the third phase of the proposed model. A distribution network of 33 buses with large penetration of DER is used to illustrate the application of the proposed model.
Resumo:
Com a alteração da legislação energética em Portugal, nomeadamente a implementação da legislação de Micro e Minigeração, a produção distribuída cresceu de forma exponencial na rede elétrica nacional, diminuindo por um lado as perdas no transporte e distribuição, e por outro aumentando a complexidade na gestão do trânsito de potência ao Distribuidor. No entanto a motivação desta dissertação prende-se com o facto de que as centrais de produção distribuída, em particular as de tecnologia fotovoltaica, pela sua dimensão, serem instaladas nos pontos de consumo, em paralelo com a instalação elétrica de utilização do cliente e como tal, têm sido verificadas diversas anomalias no funcionamento e exploração das mesmas, por influência da má qualidade de energia resultante das más condições de funcionamento e exploração em que se encontram as instalações de consumo. A presente dissertação pretende apresentar uma descrição das anomalias mais frequentes verificadas nas centrais fotovoltaicas de minigeração com origem na qualidade da energia que transita das instalações elétricas de consumo ligadas ao mesmo ponto de interligação com a rede elétrica nacional. Como base de fundamento, foram demonstradas através de três casos práticos reais, algumas das mais frequentes e prejudiciais anomalias descritas na presente dissertação. Foram escolhidos 3 casos reais com diferentes tipos de instalação de consumo sendo que um deles não apresenta qualquer anomalia de forma a comprovar o bom funcionamento em condições normais de ambas as instalações. Foram encontradas e demonstradas várias soluções paras os diferentes tipos de anomalias, no entanto esta dissertação vai permitir não só a resolução deste tipo de anomalias em centrais fotovoltaicas em exploração e já com prejuízos avultados mas também introduzir em futuras instalações a análise da qualidade da energia nas instalações de consumo em fase preliminar de estudo de implementação de centrais fotovoltaicas de minigeração e de autoconsumo, precavendo futuros problemas de rentabilidade técnico-económica. Este estudo, irá certamente servir de motor de impulsão para a preocupação com a Qualidade da Energia essencialmente dentro das instalações elétricas de consumo sensibilizando os seus gestores energéticos. Poderá ainda impulsionar a reformulação do Regulamento de Qualidade de Serviço para exigências ainda mais apertadas de forma a incorporar algumas das anomalias aqui descritas, sendo por isso um elemento de alerta para todos os “Players” do Sistema Elétrico Nacional tendo como limite a melhoria continua da Segurança e da Qualidade da energia na rede elétrica beneficiando da sensibilização de todos os intervenientes.
Resumo:
Tipicamente as redes elétricas de distribuição apresentam uma topologia parcialmente malhada e são exploradas radialmente. A topologia radial é obtida através da abertura das malhas nos locais que otimizam o ponto de operação da rede, através da instalação de aparelhos de corte que operam normalmente abertos. Para além de manterem a topologia radial, estes equipamentos possibilitam também a transferência de cargas entre saídas, aquando da ocorrência de defeitos. As saídas radiais são ainda dotadas de aparelhos de corte que operam normalmente fechados, estes têm como objetivo maximizar a fiabilidade e isolar defeitos, minimizando a área afetada pelos mesmos. Assim, na presente dissertação são desenvolvidos dois algoritmos determinísticos para a localização ótima de aparelhos de corte normalmente abertos e fechados, minimizando a potência ativa de perdas e o custo da energia não distribuída. O algoritmo de localização de aparelhos de corte normalmente abertos visa encontrar a topologia radial ótima que minimiza a potência ativa de perdas. O método é desenvolvido em ambiente Matlab – Tomlab, e é formulado como um problema de programação quadrática inteira mista. A topologia radial ótima é garantida através do cálculo de um trânsito de potências ótimo baseado no modelo DC. A função objetivo é dada pelas perdas por efeito de Joule. Por outro lado o problema é restringido pela primeira lei de Kirchhoff, limites de geração das subestações, limites térmicos dos condutores, trânsito de potência unidirecional e pela condição de radialidade. Os aparelhos de corte normalmente fechados são localizados ao longo das saídas radiais obtidas pelo anterior algoritmo, e permite minimizar o custo da energia não distribuída. No limite é possível localizar um aparelho de corte normalmente fechado em todas as linhas de uma rede de distribuição, sendo esta a solução que minimiza a energia não distribuída. No entanto, tendo em conta que a cada aparelho de corte está associado um investimento, é fundamental encontrar um equilíbrio entre a melhoria de fiabilidade e o investimento. Desta forma, o algoritmo desenvolvido avalia os benefícios obtidos com a instalação de aparelhos de corte normalmente fechados, e retorna o número e a localização dos mesmo que minimiza o custo da energia não distribuída. Os métodos apresentados são testados em duas redes de distribuição reais, exploradas com um nível de tensão de 15 kV e 30 kV, respetivamente. A primeira rede é localizada no distrito do Porto e é caraterizada por uma topologia mista e urbana. A segunda rede é localizada no distrito de Bragança e é caracterizada por uma topologia maioritariamente aérea e rural.
Resumo:
The simultaneous recording of scalp electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can provide unique insights into the dynamics of human brain function, and the increased functional sensitivity offered by ultra-high field fMRI opens exciting perspectives for the future of this multimodal approach. However, simultaneous recordings are susceptible to various types of artifacts, many of which scale with magnetic field strength and can seriously compromise both EEG and fMRI data quality in recordings above 3T. The aim of the present study was to implement and characterize an optimized setup for simultaneous EEG-fMRI in humans at 7T. The effects of EEG cable length and geometry for signal transmission between the cap and amplifiers were assessed in a phantom model, with specific attention to noise contributions from the MR scanner coldheads. Cable shortening (down to 12cm from cap to amplifiers) and bundling effectively reduced environment noise by up to 84% in average power and 91% in inter-channel power variability. Subject safety was assessed and confirmed via numerical simulations of RF power distribution and temperature measurements on a phantom model, building on the limited existing literature at ultra-high field. MRI data degradation effects due to the EEG system were characterized via B0 and B1(+) field mapping on a human volunteer, demonstrating important, although not prohibitive, B1 disruption effects. With the optimized setup, simultaneous EEG-fMRI acquisitions were performed on 5 healthy volunteers undergoing two visual paradigms: an eyes-open/eyes-closed task, and a visual evoked potential (VEP) paradigm using reversing-checkerboard stimulation. EEG data exhibited clear occipital alpha modulation and average VEPs, respectively, with concomitant BOLD signal changes. On a single-trial level, alpha power variations could be observed with relative confidence on all trials; VEP detection was more limited, although statistically significant responses could be detected in more than 50% of trials for every subject. Overall, we conclude that the proposed setup is well suited for simultaneous EEG-fMRI at 7T.
Resumo:
OBJECTIVES: Intercountry comparability between studies on medication use in pregnancy is difficult due to dissimilarities in study design and methodology. This study aimed to examine patterns and factors associated with medications use in pregnancy from a multinational perspective, with emphasis on type of medication utilised and indication for use. DESIGN: Cross-sectional, web-based study performed within the period from 1 October 2011 to 29 February 2012. Uniform collection of drug utilisation data was performed via an anonymous online questionnaire. SETTING: Multinational study in Europe (Western, Northern and Eastern), North and South America and Australia. PARTICIPANTS: Pregnant women and new mothers with children less than 1 year of age. PRIMARY AND SECONDARY OUTCOME MEASURES: Prevalence of and factors associated with medication use for acute/short-term illnesses, chronic/long-term disorders and over-the-counter (OTC) medication use. RESULTS: The study population included 9459 women, of which 81.2% reported use of at least one medication (prescribed or OTC) during pregnancy. Overall, OTC medication use occurred in 66.9% of the pregnancies, whereas 68.4% and 17% of women reported use of at least one medication for treatment of acute/short-term illnesses and chronic/long-term disorders, respectively. The extent of self-reported medicated illnesses and types of medication used by indication varied across regions, especially in relation to urinary tract infections, depression or OTC nasal sprays. Women with higher age or lower educational level, housewives or women with an unplanned pregnancy were those most often reporting use of medication for chronic/long-term disorders. Immigrant women in Western (adjusted OR (aOR): 0.55, 95% CI 0.34 to 0.87) and Northern Europe (aOR: 0.50, 95% CI 0.31 to 0.83) were less likely to report use of medication for chronic/long-term disorders during pregnancy than non-immigrants. CONCLUSIONS: In this study, the majority of women in Europe, North America, South America and Australia used at least one medication during pregnancy. There was a substantial inter-region variability in the types of medication used.
Resumo:
Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.
Resumo:
Hybrid electric vehicles (HEV) have attracted very much attention during the latest years. Increasing environmental concern and an increase in fuel prices are key factors for the growing interest towards the HEV. In a hybrid electric vehicle the power train consists of both a mechanical power system and an electric power transmission system. The major subsystems in the mechanical power system are the internal combustion engine which powers the vehicle; electric power transmission including an energy storage, power electronic inverter, hybrid control system; the electric motor drive that runs either in the generating mode or in the motoring mode to process the power flow between the energy storage and the electrical machine. This research includes two advanced electric motors for a parallel hybrid: induction machine and permanent magnets synchronous machine. In the thesis an induction motor and a permanent magnet motor are compared as propulsion motors. Electric energy storages are also studied.
Resumo:
This work presents an application of the Mobility Approach to the analysis of the power flow through grillage-like structures. Such structures are usually found in offshore platforms, supporting large and heavy machines. Different wave kinds (longitudinal, flexural and torsional) were initially considered in the power flow analysis between two beams joined in L. Beams excited by an in-plane point force showed strong coupling between longitudinal-flexural waves, while that for out-of-plane point force excitation, flexural-torsional waves coupling represents the most important mechanism of energy transmission. The response determination of grillages by the mobility approach requires the structure to be separated into simple beam-like structural components. Equations for rotations and displacements at the joints of all beams are written for as mobility functions, and moments and forces acting at the joints. A system of equations relating all such internal forces and moments is obtained. This approach was applied to simple grillages. Response results showed good agreement when compared to those provided by Finite Elements.
Resumo:
Recent Storms in Nordic countries were a reason of long power outages in huge territories. After these disasters distribution networks' operators faced with a problem how to provide adequate quality of supply in such situation. The decision of utilization cable lines rather than overhead lines were made, which brings new features to distribution networks. The main idea of this work is a complex analysis of medium voltage distribution networks with long cable lines. High value of cable’s specific capacitance and length of lines determine such problems as: high values of earth fault currents, excessive amount of reactive power flow from distribution to transmission network, possibility of a high voltage level at the receiving end of cable feeders. However the core tasks was to estimate functional ability of the earth fault protection and the possibility to utilize simplified formulas for operating setting calculations in this network. In order to provide justify solution or evaluation of mentioned above problems corresponding calculations were made and in order to analyze behavior of relay protection principles PSCAD model of the examined network have been created. Evaluation of the voltage rise in the end of a cable line have educed absence of a dangerous increase in a voltage level, while excessive value of reactive power can be a reason of final penalty according to the Finish regulations. It was proved and calculated that for this networks compensation of earth fault currents should be implemented. In PSCAD models of the electrical grid with isolated neutral, central compensation and hybrid compensation were created. For the network with hybrid compensation methodology which allows to select number and rated power of distributed arc suppression coils have been offered. Based on the obtained results from experiments it was determined that in order to guarantee selective and reliable operation of the relay protection should be utilized hybrid compensation with connection of high-ohmic resistor. Directional and admittance based relay protection were tested under these conditions and advantageous of the novel protection were revealed. However, for electrical grids with extensive cabling necessity of a complex approach to the relay protection were explained and illustrated. Thus, in order to organize reliable earth fault protection is recommended to utilize both intermittent and conventional relay protection with operational settings calculated by the use of simplified formulas.
Resumo:
Nach einem einleitenden ersten Kapitel wird im zweiten Kapitel der Stand der Technik für Regelungs- und Monitoringsysteme mit vernetzten Systemen dargestellt. Daraus wird die Motivation zur Entwicklung neuer, kostengünstiger Systeme abgeleitet. Im dritten Kapitel folgt eine Darstellung der verschiedenen Arten marktverfügbarer Embedded Systems und dafür geeigneter Betriebssysteme. Anforderungen an verteilte Regelungssysteme, unterschiedliche Strukturen dieser Systeme und deren Vor- und Nachteile sind Gegenstand des vierten Kapitels. Anhand von Beispielen aus den Bereichen Erzeugungsmanagement für den Betrieb von KWK-Anlagen, Energieverbrauchsmonitoring und Smart-Metering wird der Einsatz von verteilten Regelungs- und Monitoringsystemen im fünften Kapitel dargestellt. Im folgenden sechsten Kapitel wird die Bedeutung normierter Kommunikation für den Einsatz in verteilten Systemen sowie dafür vorhandene Standards aus der elektrischen Energieversorgungstechnik und der Automatisierungstechnik behandelt. Der Stand der Internet-Technik für verteilte Systeme ist Gegenstand des siebten Kapitels. Dabei werden zunächst die verschiedenen drahtlosen und drahtgebundenen Kommunikationsmedien vorgestellt und ihre Eigenschaften und die Randbedingungen für ihren Einsatz erörtert. Ebenso werden technische Probleme beim Einsatz der Internet-Technik aufgezeigt und Lösungsmöglichkeiten für diese Probleme dargestellt. Es folgt eine Übersicht von Netzwerkdiensten, die für den Betrieb von verteilten Systemen notwendig sind. Außerdem werden Techniken zur Überwachung von verteilten Systemen behandelt. Kapitel acht zeigt Sicherheitsrisiken bei der Nutzung des Internets auf und bewertet verschiedene Techniken zur Absicherung des Netzwerkverkehrs. Kapitel neun stellt ein Internet-basiertes Client-Server-System zur Online-Visualisierung von Anlagendaten im Webbrowser mit Hilfe von Java-Applets und XML-RPC vor. Die Visualisierung von Anlagendaten auf Mobiltelefonen mit Hilfe des Wireless Application Protocol sowie die dafür notwendige Software und Infrastruktur ist Gegenstand des zehnten Kapitels. Im elften Kapitel wird eine neuartige Software für die Simulation von dezentralen Energiesystemen und deren Regelungssystemen auf Basis von virtuellen Maschinen, virtuellen Netzwerken und einer thermischen Simulationsumgebung vorgestellt sowie deren Anwendung für die Reglerentwicklung erklärt. Verschiedene Techniken für die Installation von Betriebssystemen und Software für die Embedded Systems eines verteilten Systems werden im Kapitel zwölf untersucht. Im Kapitel 13 werden verschiedene Technologien zur Konfiguration und Parametrierung von Regelungssystemen in der industriellen Prozess- und Fertigungsautomatisierung hinsichtlich ihrer Eignung für dezentrale Energiesysteme analysiert. Anschließend wird eine Software zur Installation und Parametrierung von Monitoringsystemen sowie der dazugehörigen Infrastruktur vorgestellt. Kapitel 14 beschäftigt sich mit Anforderungen an die Hardware für verteilte Systeme und mit Maßnahmen zur Erhöhung der Betriebs- und der Datensicherheit. Im 15. Kapitel werden die in den bisherigen Kapiteln vorgestellten Techniken anhand eines großen verteilten Monitoringsystems und anhand eines Power Flow and Power Quality Management Systems auf Basis von verteilten Embedded Systems evaluiert. Kapitel 16 fasst die Ergebnisse der Arbeit zusammen und enthält einen Ausblick auf zukünftige Entwicklungen.
Resumo:
En aquesta tesi es solucionen problemes de visibilitat i proximitat sobre superfícies triangulades considerant elements generalitzats. Com a elements generalitzats considerem: punts, segments, poligonals i polígons. Les estrategies que proposem utilitzen algoritmes de geometria computacional i hardware gràfic. Comencem tractant els problemes de visibilitat sobre models de terrenys triangulats considerant un conjunt d'elements de visió generalitzats. Es presenten dos mètodes per obtenir, de forma aproximada, mapes de multi-visibilitat. Un mapa de multi-visibilitat és la subdivisió del domini del terreny que codifica la visibilitat d'acord amb diferents criteris. El primer mètode, de difícil implementació, utilitza informació de visibilitat exacte per reconstruir de forma aproximada el mapa de multi-visibilitat. El segon, que va acompanyat de resultats d'implementació, obté informació de visibilitat aproximada per calcular i visualitzar mapes de multi-visibilitat discrets mitjançant hardware gràfic. Com a aplicacions es resolen problemes de multi-visibilitat entre regions i es responen preguntes sobre la multi-visibilitat d'un punt o d'una regió. A continuació tractem els problemes de proximitat sobre superfícies polièdriques triangulades considerant seus generalitzades. Es presenten dos mètodes, amb resultats d'implementació, per calcular distàncies des de seus generalitzades sobre superfícies polièdriques on hi poden haver obstacles generalitzats. El primer mètode calcula, de forma exacte, les distàncies definides pels camins més curts des de les seus als punts del poliedre. El segon mètode calcula, de forma aproximada, distàncies considerant els camins més curts sobre superfícies polièdriques amb pesos. Com a aplicacions, es calculen diagrames de Voronoi d'ordre k, i es resolen, de forma aproximada, alguns problemes de localització de serveis. També es proporciona un estudi teòric sobre la complexitat dels diagrames de Voronoi d'ordre k d'un conjunt de seus generalitzades en un poliedre sense pesos.
Resumo:
The stability of stationary flow of a two-dimensional ice sheet is studied when the ice obeys a power flow law (Glen's flow law). The mass accumulation rate at the top is assumed to depend on elevation and span and the bed supporting the ice sheet consists of an elastic layer lying on a rigid surface. The normal perturbation of the free surface of the ice sheet is a singular eigenvalue problem. The singularity of the perturbation at the front of the ice sheet is considered using matched asymptotic expansions, and the eigenvalue problem is seen to reduce to that with fixed ice front. Numerical solution of the perturbation eigenvalue problem shows that the dependence of accumulation rate on elevation permits the existence of unstable solutions when the equilibrium line is higher than the bed at the ice divide. Alternatively, when the equilibrium line is lower than the bed, there are only stable solutions. Softening of the bed, expressed through a decrease of its elastic modulus, has a stabilising effect on the ice sheet.
Algoritmo genético para seleção de contingências na análise estática de segurança em redes elétricas
Resumo:
This study aims to analize the Cariri Paraibano territory, as a product of relations of power that were being established along its historic process of territory formation. In this process, the fragmentation and the territory management are fundamental elements to socioterritorial reality comprehension. The theoretical-conceptual basis is based on notions of territory, region, power and territory management, which are articulated to the opinions and empiric confirmations origined from interviews made with several social actions. They also were made photographical records and researches on books, newspapers and magazines, as well on other information sources related to the object of studying. Obtained data confirm the pressuposement on which the relations of dominations and the used methods by the power s owners in the region created a little fruitful political practice and little adequate to the process of active participation of the local population on the territory management, even being on disagreement with the new political-institutional mechanisms, which take to political-administrative more democratic and participative in the country