905 resultados para Incomplete Block-designs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the clinical, electrocardiographic, and electrophysiologic characteristics of patients (pt) with intra-His bundle block undergoing an electrophysiologic study (EPS). METHODS: We analyzed the characteristics of 16 pt with second-degree atrioventricular block and symptoms of syncope or dyspnea, or both, undergoing conventional EPS. RESULTS: Intra-His bundle block was documented in 16 pt during an EPS. In 15 (94%) pt, the atrioventricular block was recorded in sinus rhythm; 4 (25%) pt had intra-His Wenckebach phenomenon, which correlated with Mobitz I (MI) atrioventricular block on the electrocardiogram. Seven (44%) pt had 2:1 atrioventricular block, 2 of whom were asymptomatic (12.5%). One (6%) pt had intra- and infra-His bundle block. Clinically, 11 (68%) pt had syncope or presyncope, 3 (18%) had dyspnea on exertion, and 2 (12.5%) were asymptomatic. Eight (50%) pt had bundle-branch block as follows: 4 (25%) pt had left bundle-branch block, and 4 (25%) had right bundle-branch block. Left anterosuperior divisional block was observed in 3 pt (19%), 2 of whom with associated right bundle-branch block. CONCLUSION: Intra-His bundle block was observed in 11% of the pt with second-degree atrioventricular block, syncope or presyncope, or both, it being the most frequent clinical presentation. Intra-His bundle block was more common in the elderly (> 60 years) and among females. The most frequent electrocardiographic presentations were second-degree Mobitz I or type 2:1 atrioventricular block.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mesophilic Anaerobic Digestion treating sewage sludge was investigated at five full-scale sewage treatment plants in Ireland. The anaerobic digestion plants are compared and evaluated in terms of design, equipment, operation, monitoring and management. All digesters are cylindrical, gas mixed and heated Continuously Stirred Tank Reactors (CSTR), varying in size from 130m3 to 800m3. Heat exchanger systems heat all digesters. Three plants reported difficulties with the heating systems ranging from blockages to insufficient insulation and design. Exchangers were modified and replaced within one year of operation at two plants. All but one plant had Combined Heat and Power (CHP) systems installed. Parameter monitoring is a problem at all plants mainly due to a lack of staff and knowledge. The plant operators consider pH and temperature the most important parameters to be measured in terms of successful monitoring of an anaerobic digester. The short time taken and the ease at which pH and temperature can be measured may favour these parameters. Three laboratory scale pilot anaerobic digesters were operated using a variety of feeds over at 144-day period. Two of the pilots were unmixed and the third was mechanically mixed. As expected the unmixed reactors removed more COD by retention of solids in the digesters but also produced greater quantities of biogas than the mixed digester, especially when low solids feed such as whey was used. The mixed digester broke down more solids due to the superior contact between the substrate and the biomass. All three reactors showed good performance results for whey and sewage solids. Scum formation occurred giving operational problems for mixed and unmixed reactors when cattle slurry was used as the main feed source. The pilot test was also used to investigate which parameters were the best indicators of process instability. These trials clearly indicated that total Volatile Fatty Acid (VFA) concentrations was the best parameter to show signs of early process imbalance, while methane composition in the biogas was good to indicate possible nutrient deficiencies in the feed and oxygen shocks. pH was found to be a good process parameter only if the wastewater being treated produced low bicarbonate alkalinities during treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Mathematik, Diss., 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:The QRS-T angle correlates with prognosis in patients with heart failure and coronary artery disease, reflected by an increase in mortality proportional to an increase in the difference between the axes of the QRS complex and T wave in the frontal plane. The value of this correlation in patients with Chagas heart disease is currently unknown.Objective:Determine the correlation of the QRS-T angle and the risk of induction of ventricular tachycardia / ventricular fibrillation (VT / VF) during electrophysiological study (EPS) in patients with Chagas disease.Methods:Case-control study at a tertiary center. Patients without induction of VT / VF on EPS were used as controls. The QRS-T angle was categorized as normal (0-105º), borderline (105-135º) or abnormal (135-180º). Differences between groups for continuous variables were analyzed with the t test or Mann-Whitney test, and for categorical variables with Fisher's exact test. P values < 0.05 were considered significant.Results:Of 116 patients undergoing EPS, 37.9% were excluded due to incomplete information / inactive records or due to the impossibility to correctly calculate the QRS-T angle (presence of left bundle branch block and atrial fibrillation). Of 72 patients included in the study, 31 induced VT / VF on EPS. Of these, the QRS-T angle was normal in 41.9%, borderline in 12.9% and abnormal in 45.2%. Among patients without induction of VT / VF on EPS, the QRS-T angle was normal in 63.4%, borderline in 14.6% and abnormal in 17.1% (p = 0.04). When compared with patients with normal QRS-T angle, those with abnormal angle had a fourfold higher risk of inducing ventricular tachycardia / ventricular fibrillation on EPS [odds ratio (OR) 4; confidence interval (CI) 1.298-12.325; p = 0.028]. After adjustment for other variables such as age, ejection fraction (EF) and QRS size, there was a trend for the abnormal QRS-T angle to identify patients with increased risk of inducing VT / VF during EPS (OR 3.95; CI 0.99-15.82; p = 0.052). The EF also emerged as a predictor of induction of VT / VF: for each point increase in EF, there was a 4% reduction in the rate of sustained ventricular arrhythmia on EPS.Conclusions:Changes in the QRS-T angle and decreases in EF were associated with an increased risk of induction of VT / VF on EPS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Isolated congenital atrioventricular block (CAVB) is a rare condition with multiple clinical outcomes. Ventricular remodeling can occur in approximately 10% of the patients after pacemaker (PM) implantation.Objectives:To assess the functional capacity of children and young adults with isolated CAVB and chronic pacing of the right ventricle (RV) and evaluate its correlation with predictors of ventricular remodeling.Methods:This cross-sectional study used a cohort of patients with isolated CAVB and RV pacing for over a year. The subjects underwent clinical and echocardiographic evaluation. Functional capacity was assessed using the six-minute walk test. Chi-square test, Fisher's exact test, and Pearson correlation coefficient were used, considering a significance level of 5%.Results:A total of 61 individuals were evaluated between March 2010 and December 2013, of which 67.2% were women, aged between 7 and 41 years, who were using PMs for 13.5 ± 6.3 years. The percentage of ventricular pacing was 97.9 ± 4.1%, and the duration of the paced QRS complex was 153.7 ± 19.1 ms. Majority of the subjects (95.1%) were asymptomatic and did not use any medication. The mean distance walked was 546.9 ± 76.2 meters and was strongly correlated with the predicted distance (r = 0.907, p = 0.001) but not with risk factors for ventricular remodeling. (Arq Bras Cardiol. 2014; [online].ahead print, PP.0-0)Conclusions:The functional capacity of isolated CAVB patients with chronic RV pacing was satisfactory but did not correlate with risk factors for ventricular remodeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee. Results: The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Mathematik, Diss., 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Mathematik, Diss., 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Mathematik, Diss., 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with a generalization of square lattice designs, with k² treatments in blocks of k + 1 plots, the extra plot in each block receiving a standard treatment, the same for all blocks. The new design leads to lower variances for contrasts between adjusted treatment means

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Mathematik, Diss., 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Otto-von-Guericke-Universität Magdeburg, Fakultät für Mathematik, Dissertation, 2016

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Bank of Spain uses a unique auction format to sell government bonds, which can be seen as a hybrid of a uniform and a discriminatory auction. For winning bids above the average winning bid, buyers are charged the average winning bid, otherwise they pay their respective bids. We report on an experiment that compares this auction format to the discriminatory format, used in most other countries, and to the uniform format. Our design is based on a common value model with multi-unit supply and two-unit demand. The results show significantly higher revenue with the Spanish and the uniform formats than with the discriminatory one, while volatility of prices over time is significantly lower in the discriminatory format than in the Spanish and uniform cases. Actual price dispersion is significantly larger in the discriminatory than in the Spanish. Our data also exhibit the use of bid-spreading strategies in all three designs.