709 resultados para IMRT QA


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intracellular membrane fusion proceeds via distinct stages of membrane docking, hemifusion and fusion pore opening and depends on interacting families of Rab, SNARE and SM proteins. Trans-SNARE complexes dock the membranes in close apposition. Efficient fusion requires further SNARE-associated proteins. They might increase the number of trans-SNARE complexes or the fusogenic potential of a single SNARE complex. We investigated the contributions of the SM protein Vps33 to hemifusion and pore opening between yeast vacuoles. Mutations in Vps33 that weaken its interactions with the SNARE complex allowed normal trans-SNARE pairing and lipid mixing but retarded content mixing. Deleting the H(abc) domain of the vacuolar t-SNARE Vam3, which interacts with Vps33, had the same effect. This suggests that SM proteins promote fusion pore opening by enhancing the fusogenic activity of a SNARE complex. They should thus be considered integral parts of the fusion machinery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was to evaluate the treatment dosimetry, efficacy and toxicity of intensity modulated radiation therapy (IMRT) and fractionated stereotactic radiotherapy (FSRT) in the management of infratentorial ependymoma. Between 1999 and 2007, seven children (median age, 3.1 years) with infratentorial ependymoma were planned with either IMRT (3 patients) or SFRT (4 patients), the latter after conventional posterior fossa irradiation. Two children underwent gross total resection. Median prescribed dose was 59.4 Gy (range, 55.8-60). The median follow-up for surviving patients was 4.8 years (range, 1.3-8). IMRT (median dose, 59.4 Gy) and FSRT (median dose, 55.8 Gy) achieved similar optimal target coverage. Percentages of maximum doses delivered to the cochleae (59.5 vs 85.0% Gy; P = 0.05) were significantly inferior with IMRT, when compared to FSRT planning. Percentages of maximum doses administered to the pituitary gland (38.2 vs 20.1%; P = 0.05) and optic chiasm (38.1 vs 14.1%; P = 0.001) were, however, significantly higher with IMRT, when compared to FSRT planning. No recurrences were observed at the last follow-up. The estimated 3-year progression-free survival and overall survival were 87.5 and 100%, respectively. No grade >1 acute toxicity was observed. Two patients presented late adverse events (grade 2 hypoacousia) during follow-up, without cognitive impairment. IMRT or FSRT for infratentorial ependymomas is effective and associated with a tolerable toxicity level. Both treatment techniques were able to capitalize their intrinsic conformal ability to deliver high-dose radiation. Larger series of patients treated with these two modalities will be necessary to more fully evaluate these delivery techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Panitumumab (pmab), a fully human monoclonal antibody against the epidermal growth factor receptor (EGFR), is indicated as monotherapy for treatment of metastatic colorectal cancer. This ongoing study is designed to assess the efficacy and safety of pmab in combination with radiotherapy (PRT) compared to chemoradiotherapy (CRT) as initial treatment of unresected, locally advanced SCCHN (ClinicalTrials.gov Identifier: NCT00547157). Methods: This is a phase 2, open-label, randomized, multicenter study. Eligible patients (pts) were randomized 2:3 to receive cisplatin 100 mg/m2 on days 1 and 22 of RT or pmab 9.0 mg/kg on days 1, 22, and 43. Accelerated RT (70 to 72 Gy − delivered over 6 to 6.5 weeks) was planned for all pts and was delivered either by intensity-modulated radiation therapy (IMRT) modality or by three-dimensional conformal (3D-CRT) modality. The primary endpoint is local-regional control (LRC) rate at 2 years. Key secondary endpoints include PFS, OS, and safety. An external, independent data monitoring committee conducts planned safety and efficacy reviews during the course of the trial. Results: Pooled data from this planned interim safety analysis includes the first 52 of the 150 planned pts; 44 (84.6%) are male; median (range) age is 57 (33−77) years; ECOG PS 0: 65%, PS 1: 35%; 20 (39%) pts received IMRT, and 32 (61%) pts received 3D-CRT. Fifty (96%) pts completed RT, and 50 pts received RT per protocol without a major deviation. The median (range) total RT dose administered was 72 (64−74) Gy. The most common grade _ 3 adverse events graded using the CTCAE version 3.0 are shown (Table). Conclusions: After the interim safety analysis, CONCERT-2 continues per protocol. Study enrollment is estimated to be completed by October 2009.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last decades, new technologies have been introduced in the daily clinical practice of the radiation oncologist: 3D-Conformal radiotherapy (RT) became almost universally available, thereafter, intensity modulated RT (IMRT) gained large diffusion, due to its potential impact in improving the clinical outcomes, and more recently, helical and volumetric arc IMRT with image-guided RT are becoming more and more diffused and used for prostate cancer patients. The conventional dose-fractionation results to be the best compromise between the efficacy and the safety of the treatment, but combining new techniques, modern RT allows to overcame one of the major limits of the 'older' RT: the impossibility of delivering higher total doses and/or high dose/fraction. The evidences regarding radiobiology, clinical and technological evolution of RT in prostate cancer have been reported and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: We retrospectively reviewed the long-term outcome and late side effects of endometrial cancer (EC) patients treated with different techniques of postoperative radiotherapy (PORT). METHODS: Between 1999 and 2012, 237 patients with EC were treated with PORT. Two-dimensional external beam radiotherapy (2D-EBRT) was used in 69 patients (30 %), three-dimensional EBRT (3D-EBRT) in 51 (21 %), and intensity-modulated RT (IMRT) with helical Tomotherapy in 47 (20 %). All patients received a vaginal brachytherapy (VB) boost. Seventy patients (29 %) received VB alone. RESULTS: After a median of 68 months (range, 6-154) of follow-up, overall survival was 75 % [95 % confidence interval (CI), 69-81], disease-free survival was 72 % (95% CI, 66-78), cancer-specific survival was 85 % (95 % CI, 80-89), and locoregional control was 86 % (95 % CI, 81-91). The 5-year estimates of grade 3 or more toxicity and second cancer rates were 0 and 7 % (95 % CI, 1-13) for VB alone, 6 % (95 % CI, 1-11) and 0 % for IMRT + VB, 9 % (95 % CI, 1-17) and 5 % (95 % CI, 1-9) for 3D-EBRT + VB, and 22 % (95 % CI, 12-32) and 12 % (95 % CI, 4-20) for 2D-EBRT + VB (P = 0.002 and P = 0.01), respectively. CONCLUSIONS: Pelvic EBRT should be tailored to patients with high-risk EC because the severe late toxicity observed might outweigh the benefits. When EBRT is prescribed for EC, IMRT should be considered, because it was associated with a significant reduction of severe late side effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: We investigated the influence of beam modulation on treatment planning by comparing four available stereotactic radiosurgery (SRS) modalities: Gamma-Knife-Perfexion, Novalis-Tx Dynamic-Conformal-Arc (DCA) and Dynamic-Multileaf-Collimation-Intensity-Modulated-radiotherapy (DMLC-IMRT), and Cyberknife. MATERIAL AND METHODS: Patients with arteriovenous malformation (n = 10) or acoustic neuromas (n = 5) were planned with different treatment modalities. Paddick conformity index (CI), dose heterogeneity (DH), gradient index (GI) and beam-on time were used as dosimetric indices. RESULTS: Gamma-Knife-Perfexion can achieve high degree of conformity (CI = 0.77 ± 0.04) with limited low-doses (GI = 2.59 ± 0.10) surrounding the inhomogeneous dose distribution (D(H) = 0.84 ± 0.05) at the cost of treatment time (68.1 min ± 27.5). Novalis-Tx-DCA improved this inhomogeneity (D(H) = 0.30 ± 0.03) and treatment time (16.8 min ± 2.2) at the cost of conformity (CI = 0.66 ± 0.04) and Novalis-TX-DMLC-IMRT improved the DCA CI (CI = 0.68 ± 0.04) and inhomogeneity (D(H) = 0.18 ± 0.05) at the cost of low-doses (GI = 3.94 ± 0.92) and treatment time (21.7 min ± 3.4) (p<0.01). Cyberknife achieved comparable conformity (CI = 0.77 ± 0.06) at the cost of low-doses (GI = 3.48 ± 0.47) surrounding the homogeneous (D(H) = 0.22 ± 0.02) dose distribution and treatment time (28.4min±8.1) (p<0.01). CONCLUSIONS: Gamma-Knife-Perfexion will comply with all SRS constraints (high conformity while minimizing low-dose spread). Multiple focal entries (Gamma-Knife-Perfexion and Cyberknife) will achieve better conformity than High-Definition-MLC of Novalis-Tx at the cost of treatment time. Non-isocentric beams (Cyberknife) or IMRT-beams (Novalis-Tx-DMLC-IMRT) will spread more low-dose than multiple isocenters (Gamma-Knife-Perfexion) or dynamic arcs (Novalis-Tx-DCA). Inverse planning and modulated fluences (Novalis-Tx-DMLC-IMRT and CyberKnife) will deliver the most homogeneous treatment. Furthermore, Linac-based systems (Novalis and Cyberknife) can perform image verification at the time of treatment delivery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Whole pelvis intensity modulated radiotherapy (IMRT) is increasingly being used to treat cervical cancer aiming to reduce side effects. Encouraged by this, some groups have proposed the use of simultaneous integrated boost (SIB) to target the tumor, either to get a higher tumoricidal effect or to replace brachytherapy. Nevertheless, physiological organ movement and rapid tumor regression throughout treatment might substantially reduce any benefit of this approach. PURPOSE: To evaluate the clinical target volume - simultaneous integrated boost (CTV-SIB) regression and motion during chemo-radiotherapy (CRT) for cervical cancer, and to monitor treatment progress dosimetrically and volumetrically to ensure treatment goals are met. METHODS AND MATERIALS: Ten patients treated with standard doses of CRT and brachytherapy were retrospectively re-planned using a helical Tomotherapy - SIB technique for the hypothetical scenario of this feasibility study. Target and organs at risk (OAR) were contoured on deformable fused planning-computed tomography and megavoltage computed tomography images. The CTV-SIB volume regression was determined. The center of mass (CM) was used to evaluate the degree of motion. The Dice's similarity coefficient (DSC) was used to assess the spatial overlap of CTV-SIBs between scans. A cumulative dose-volume histogram modeled estimated delivered doses. RESULTS: The CTV-SIB relative reduction was between 31 and 70%. The mean maximum CM change was 12.5, 9, and 3 mm in the superior-inferior, antero-posterior, and right-left dimensions, respectively. The CTV-SIB-DSC approached 1 in the first week of treatment, indicating almost perfect overlap. CTV-SIB-DSC regressed linearly during therapy, and by the end of treatment was 0.5, indicating 50% discordance. Two patients received less than 95% of the prescribed dose. Much higher doses to the OAR were observed. A multiple regression analysis showed a significant interaction between CTV-SIB reduction and OAR dose increase. CONCLUSIONS: The CTV-SIB had important regression and motion during CRT, receiving lower therapeutic doses than expected. The OAR had unpredictable shifts and received higher doses. The use of SIB without frequent adaptation of the treatment plan exposes cervical cancer patients to an unpredictable risk of under-dosing the target and/or overdosing adjacent critical structures. In that scenario, brachytherapy continues to be the gold standard approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Density is an important component of hot-mix asphalt (HMA) pavement quality and long-term performance. Insufficient density of an in-place HMA pavement is the most frequently cited construction-related performance problem. This study evaluated the use of electromagnetic gauges to nondestructively determine densities. Field and laboratory measurements were taken with two electromagnetic gauges—a PaveTracker and a Pavement Quality Indicator (PQI). Test data were collected in the field during and after paving operations and also in a laboratory on field mixes compacted in the lab. This study revealed that several mix- and project-specific factors affect electromagnetic gauge readings. Consequently, the implementation of these gauges will likely need to be done utilizing a test strip on a project- and mix-specific basis to appropriately identify an adjustment factor for the specific electromagnetic gauge being used for quality control and quality assurance (QC/QA) testing. The substantial reduction in testing time that results from employing electromagnetic gauges rather than coring makes it possible for more readings to be used in the QC/QA process with real-time information without increasing the testing costs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Membrane fusion and fission are antagonistic reactions controlled by different proteins. Dynamins promote membrane fission by GTP-driven changes of conformation and polymerization state, while SNAREs fuse membranes by forming complexes between t- and v-SNAREs from apposed vesicles. Here, we describe a role of the dynamin-like GTPase Vps1p in fusion of yeast vacuoles. Vps1p forms polymers that couple several t-SNAREs together. At the onset of fusion, the SNARE-activating ATPase Sec18p/NSF and the t-SNARE depolymerize Vps1p and release it from the membrane. This activity is independent of the SNARE coactivator Sec17p/alpha-SNAP and of the v-SNARE. Vps1p release liberates the t-SNAREs for initiating fusion and at the same time disrupts fission activity. We propose that reciprocal control between fusion and fission components exists, which may prevent futile cycles of fission and fusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we present the segmentation of the headand neck lymph node regions using a new active contourbased atlas registration model. We propose to segment thelymph node regions without directly including them in theatlas registration process; instead, they are segmentedusing the dense deformation field computed from theregistration of the atlas structures with distinctboundaries. This approach results in robust and accuratesegmentation of the lymph node regions even in thepresence of significant anatomical variations between theatlas-image and the patient's image to be segmented. Wealso present a quantitative evaluation of lymph noderegions segmentation using various statistical as well asgeometrical metrics: sensitivity, specificity, dicesimilarity coefficient and Hausdorff distance. Acomparison of the proposed method with two other state ofthe art methods is presented. The robustness of theproposed method to the atlas selection, in segmenting thelymph node regions, is also evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To report a single-center experience treating patients with squamous- cell carcinoma of the anal canal using helical Tomotherapy (HT) and concurrent chemotherapy (CT).Materials/Methods: From October 2007 to February 2011, 55 patients were treated with HT and concurrent CT (5-fluorouracil/capecitabin and mitomycin) for anal squamous-cell carcinoma. All patients underwent computed- tomography-based treatment planning, with pelvic and inguinal nodes receiving 36 Gy in 1.8 Gy/fraction. Following a planned 1-week break, primary tumor site and involved nodes were boosted to a total dose 59.4 Gy in 1.8 Gy/fraction. Dose-volume histograms of several organs at risk (OAR; bladder, small intestine, rectum, femoral heads, penile bulb, external genitalia) were assessed in terms of conformal avoidance. All toxicity was scored according to the CTCAE, v.3.0. HT plans and treatment were implemented using the Tomotherapy, Inc. software and hardware. For dosimetric comparisons, 3D RT and/or IMRT plans were also computed for some of the patients using the CMS planning system, for treatment with 6-18 MV photons and/or electrons with suitable energies from a Siemens Primus linear accelerator equipped with a multileaf collimator.Locoregional control and survival curves were compared with the log-rank test, and multivariate analysis by the Cox model.Results: With 360-degree-of-freedom beam projection, HT has an advantage over other RT techniques (3D or 5-field step-and-shot IMRT). There is significant improvement over 3D or 5-field IMRT plans in terms of dose conformity around the PTV, and dose gradients are steeper outside the target volume, resulting in reduced doses to OARs. Using HT, acute toxicity was acceptable, and seemed to be better than historical standards.Conclusions: Our results suggest that HT combined with concurrent CT for anal cancer is effective and tolerable. Compared to 3D RT or 5-field step-andshot IMRT, there is better conformity around the PTV, and better OAR sparing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Helical tomotherapy is a relatively new intensity-modulated radiation therapy (IMRT) treatment for which room shielding has to be reassessed for the following reasons. The beam-on-time needed to deliver a given target dose is increased and leads to a weekly workload of typically one order of magnitude higher than that for conventional radiation therapy. The special configuration of tomotherapy units does not allow the use of standard shielding calculation methods. A conventional linear accelerator must be shielded for primary, leakage and scatter photon radiations. For tomotherapy, primary radiation is no longer the main shielding issue since a beam stop is mounted on the gantry directly opposite the source. On the other hand, due to the longer irradiation time, the accelerator head leakage becomes a major concern. An analytical model based on geometric considerations has been developed to determine leakage radiation levels throughout the room for continuous gantry rotation. Compared to leakage radiation, scatter radiation is a minor contribution. Since tomotherapy units operate at a nominal energy of 6 MV, neutron production is negligible. This work proposes a synthetic and conservative model for calculating shielding requirements for the Hi-Art II TomoTherapy unit. Finally, the required concrete shielding thickness is given for different positions of interest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: This trial randomly assessed short-term adjuvant hormonal therapy added to radiotherapy (RT) for intermediate- and high-risk (UICC 1997 cT2a or cT1b-c with high PSA or Gleason score) localised prostate cancer. We report acute toxicity (CTCAE v2) assessed weekly during RT in relation to radiation parameters. PATIENTS AND METHODS: Centres selected the RT dose (70, 74 or 78Gy) and RT technique. Statistical significance is at 0.05. RESULTS: Of 791 patients, 652 received 3D-CRT (70Gy: 195, 74Gy: 376, 78Gy: 81) and 139 received IMRT (74Gy: 28, 78Gy: 111). During RT, grade 3 gastrointestinal (GI) and genitourinary (GU) toxicities were reported by 7 (0.8%) and 50 (6.3%) patients, respectively. No grade 4 was reported. The risk of grade 2 GI toxicity increased significantly with increasing D50%-rectum (p=0.004) and that of grade 2 GU toxicity correlated only to Dmax-bladder (p=0.051). 3D-RT technique, increasing total dose and V95% >400 cc increased D50% and Dmax. One month after RT, only 14 patients (1.8%) reported grade 3 toxicity. AST did not seem to influence the risk of GU or GI acute toxicity. CONCLUSION: RT up to 78Gy was well tolerated. Dmax-bladder and D50%-rectum influenced the risk of grade 2 GU toxicity and GI toxicity, respectively. Both were lower with IMRT but remained high for an irradiated RT volume>400 cc for 3D-RT and for a dose of 78Gy. Hormonal treatment did not influence acute toxicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Asphalt pavements suffer various failures due to insufficient quality within their design lives. The American Association of State Highway and Transportation Officials (AASHTO) Mechanistic-Empirical Pavement Design Guide (MEPDG) has been proposed to improve pavement quality through quantitative performance prediction. Evaluation of the actual performance (quality) of pavements requires in situ nondestructive testing (NDT) techniques that can accurately measure the most critical, objective, and sensitive properties of pavement systems. The purpose of this study is to assess existing as well as promising new NDT technologies for quality control/quality assurance (QC/QA) of asphalt mixtures. Specifically, this study examined field measurements of density via the PaveTracker electromagnetic gage, shear-wave velocity via surface-wave testing methods, and dynamic stiffness via the Humboldt GeoGauge for five representative paving projects covering a range of mixes and traffic loads. The in situ tests were compared against laboratory measurements of core density and dynamic modulus. The in situ PaveTracker density had a low correlation with laboratory density and was not sensitive to variations in temperature or asphalt mix type. The in situ shear-wave velocity measured by surface-wave methods was most sensitive to variations in temperature and asphalt mix type. The in situ density and in situ shear-wave velocity were combined to calculate an in situ dynamic modulus, which is a performance-based quality measurement. The in situ GeoGauge stiffness measured on hot asphalt mixtures several hours after paving had a high correlation with the in situ dynamic modulus and the laboratory density, whereas the stiffness measurement of asphalt mixtures cooled with dry ice or at ambient temperature one or more days after paving had a very low correlation with the other measurements. To transform the in situ moduli from surface-wave testing into quantitative quality measurements, a QC/QA procedure was developed to first correct the in situ moduli measured at different field temperatures to the moduli at a common reference temperature based on master curves from laboratory dynamic modulus tests. The corrected in situ moduli can then be compared against the design moduli for an assessment of the actual pavement performance. A preliminary study of microelectromechanical systems- (MEMS)-based sensors for QC/QA and health monitoring of asphalt pavements was also performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Quality Management Earthwork (QM-E) special provision was implemented on a pilot project to evaluate quality control (QC) and quality assurance (QA) testing in predominately unsuitable soils. Control limits implemented on this pilot project included the following: 95% relative compaction, moisture content not exceeding +/- 2% of optimum moisture content, soil strength not exceeding a dynamic cone penetrometer (DCP) index of 70 mm/blow, vertical uniformity not exceeding a variation in DCP index of 40 mm/blow, and lift thickness not exceeding depth determined through construction of control strips. Four-point moving averages were used to allow for some variability in the measured parameter values. Management of the QC/QA data proved to be one of the most challenging aspects of the pilot project. Implementing use of the G-RAD data collection system has considerable potential to reduce the time required to develop and maintain QC/QA records for projects using the QM-E special provision. In many cases, results of a single Proctor test were used to establish control limits that were used for several months without retesting. While the data collected for the pilot project indicated that the DCP index control limits could be set more tightly, there is not enough evidence to support making a change. In situ borings, sampling, and testing in natural unsuitable cut material and compacted fill material revealed that the compacted fill had similar strength characteristics to that of the natural cut material after less than three months from the start of construction.