920 resultados para IMAGING TECHNIQUES


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND:
Age-related macular degeneration (AMD) and Alzheimer's disease (AD) share several features, including the presence of extracellular abnormal deposits associated with neuronal degeneration, drusen, and plaques, respectively. Investigation of any association of AMD and specifically AD is worthwhile but has rarely been done.
OBJECTIVES:
The aim of this study was to determine the prevalence of AMD in subjects with AD in comparison with an age-matched cognitively normal cohort.
METHODS:
Cases were defined as those diagnosed with AD using standardized criteria as part of their clinical care, while controls were cognitively intact individuals aged 65 years or more. Dilated retinal photographs were taken, and a range of potentially confounding factors measured including APOE genotype. AMD features were recorded and AMD grades given.
RESULTS:
Data was collected on 322 controls and 258 cases. While AMD was associated with AD, and the proportion of cases of advanced AMD in AD cases was twice that of controls, when corrected the association was lost. AD was associated with age, the presence of an APOE allele, and smoking, while being 'generally unwell recently' was associated with a reduced risk of AD.
CONCLUSION:
AD and AMD are both associated with age, but our study does not find evidence they are associated with each other. However the retina offers an opportunity to non-invasively image neuronal tissue, and more sophisticated imaging techniques may shed light on ocular biomarkers of AD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Here we review the recent progress made in the detection, examination, characterisation and interpretation of oscillations manifesting in small-scale magnetic elements in the solar photosphere. This region of the Sun's atmosphere is especially dynamic, and importantly, permeated with an abundance of magnetic field concentrations. Such magnetic features can span diameters of hundreds to many tens of thousands of km, and are thus commonly referred to as the `building blocks' of the magnetic solar atmosphere. However, it is the smallest magnetic elements that have risen to the forefront of solar physics research in recent years. Structures, which include magnetic bright points, are often at the diffraction limit of even the largest of solar telescopes. Importantly, it is the improvements in facilities, instrumentation, imaging techniques and processing algorithms during recent years that have allowed researchers to examine the motions, dynamics and evolution of such features on the smallest spatial and temporal scales to date. It is clear that while these structures may demonstrate significant magnetic field strengths, their small sizes make them prone to the buffeting supplied by the ubiquitous surrounding convective plasma motions. Here, it is believed that magnetohydrodynamic waves can be induced, which propagate along the field lines, carrying energy upwards to the outermost extremities of the solar corona. Such wave phenomena can exist in a variety of guises, including fast and slow magneto-acoustic modes, in addition to Alfven waves. Coupled with rapid advancements in magnetohydrodynamic wave theory, we are now in an ideal position to thoroughly investigate how wave motion is generated in the solar photosphere, which oscillatory modes are most prevalent, and the role that these waves play in supplying energy to various layers of the solar atmosphere.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese de mestrado, Química Farmacêutica e Terapêutica, Universidade de Lisboa, Faculdade de Farmácia, 2013

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese de mestrado integrado em Engenharia Biomédica e Biofísica, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2014

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese de doutoramento, Biologia (Biologia do Desenvolvimento), Universidade de Lisboa, Faculdade de Ciências, 2015

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese de mestrado. Oncobiologia, Faculdade de Medicina, Universidade de Lisboa, 2015

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Central obesity is the hallmark of a number of non-inheritable disorders. The advent of imaging techniques such asMRI has allowed for a fast and accurate assessment of body fat content and distribution. However, image analysis continues to be one of the major obstacles to the use of MRI in large-scale studies. In this study we assess the validity of the recently proposed fat–muscle quantitation system (AMRATM Profiler) for the quantification of intra-abdominal adipose tissue (IAAT) and abdominal subcutaneous adipose tissue (ASAT) from abdominal MR images. Abdominal MR images were acquired from 23 volunteers with a broad range of BMIs and analysed using sliceOmatic, the current gold-standard, and the AMRATM Profiler based on a non-rigid image registration of a library of segmented atlases. The results show that there was a highly significant correlation between the fat volumes generated by the two analysis methods, (Pearson correlation r = 0.97, p < 0.001), with the AMRATM Profiler analysis being significantly faster (~3 min) than the conventional sliceOmatic approach (~40 min). There was also excellent agreement between the methods for the quantification of IAAT (AMRA 4.73 ± 1.99 versus sliceOmatic 4.73 ± 1.75 l, p = 0.97). For the AMRATM Profiler analysis, the intra-observer coefficient of variation was 1.6% for IAAT and 1.1% for ASAT, the inter-observer coefficient of variationwas 1.4%for IAAT and 1.2%for ASAT, the intra-observer correlationwas 0.998 for IAAT and 0.999 for ASAT, and the inter-observer correlation was 0.999 for both IAAT and ASAT. These results indicate that precise and accurate measures of body fat content and distribution can be obtained in a fast and reliable form by the AMRATM Profiler, opening up the possibility of large-scale human phenotypic studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study addresses to the optimization of pultrusion manufacturing process from the energy-consumption point of view. The die heating system of external platen heaters commonly used in the pultrusion machines is one of the components that contribute the most to the high consumption of energy of pultrusion process. Hence, instead of the conventional multi-planar heaters, a new internal die heating system that leads to minor heat losses is proposed. The effect of the number and relative position of the embedded heaters along the die is also analysed towards the setting up of the optimum arrangement that minimizes both the energy rate and consumption. Simulation and optimization processes were greatly supported by Finite Element Analysis (FEA) and calibrated with basis on the temperature profile computed through thermography imaging techniques. The main outputs of this study allow to conclude that the use of embedded cylindrical resistances instead of external planar heaters leads to drastic reductions of both the power consumption and the warm-up periods of the die heating system. For the analysed die tool and process, savings on energy consumption up to 60% and warm-up period stages less than an half hour were attained with the new internal heating system. The improvements achieved allow reducing the power requirements on pultrusion process, and thus minimize industrial costs and contribute to a more sustainable pultrusion manufacturing industry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Resumo: A hiperplasia benigna da próstata (HBP) tem elevada prevalência nos homens entre os 50 e 79 anos de idade, sendo ubiquitária com o envelhecimento. Devido à significativa morbi-mortalidade associada aos tratamentos médicos e cirúrgicos currentemente disponíveis, são necessárias novas tecnologias para melhorar os resultados e minimizar o desconforto dos doentes. Recentemente, estudos preliminares de experimentação animal e em 3 doentes tratados, sugeriram a embolização arterial prostática selectiva (EAPS) como hipótese terapêutica para a HBP. Decidimos investigar se a EAPS poderia ser um procedimento bem sucedido no tratamento da HBP gravemente sintomática. Para tal realizámos um estudo anátomo-radiológico e clínico em 63 doentes com recurso a uma terapêutica inovadora minimamente invasiva guiada pela imagem. Avaliámos 126 hemipélvis com recurso a Angio-RM, Angio-TC e Angiografia Digital de Subtracção, com o intuito de definir os padrões básicos de bifurcação das artérias ilíacas internas até agora apenas descritos em estudos cadavéricos. Estudámos ainda o suprimento vascular arterial prostático, identificando: 1 as artérias prostáticas; 2 origem e direcção; 3 os ramos intra-prostáticos; 4 anastomoses com outras artérias. Em relação aos resultados anatómicos, identificámos 181 artérias prostáticas, já que em 43.7% das hemipélvis existiam dois pedículos arteriais prostáticos com origens independentes. A origem mais frequente foi a artéria pudenda interna (39.7%), seguida do tronco comum glúteo-pudendo (21%) e da artéria vesical superior (18.2%). Origens menos frequentes foram a artéria obturadora (12.1%), as artérias glúteas inferior (3.9%)ou superior (1.7%), ramos rectais provenientes da artéria mesentérica inferior (1.7%) e a artéria pudenda acessória (1.7%). Identificaram-se anastomoses com as artérias adjacentes em 57.9% dos casos: com a terminação da artéria pudenda interna (41.6%),artérias prostáticas contra-laterais (18.2%) e homo-laterais (11.7%), com ramos rectais (15.6%) e com artérias vesicais (12.9%). Em relação ao estudo clínico tratámos 63 doentes (idades compreendidas entre 52 - 82 anos, média 69.5 anos) com HBP gravemente sintomática refractária à terapêutica médica há mais de 6 meses. Foi possível avaliação após o tratamento em 37 doentes: média de seguimento de 4.7 meses (variando entre 1 e 12 meses). A EAPS unilateral foi possível em todos os doentes, com embolização bilateral em 73% dos casos. A embolização bilateral não foi possível em 27% dos casos devido a tortuosidade, alterações ateroescleróticas e pequeno calibre das artérias ilíacas e/ou prostáticas. Em média houve uma melhoria do International Prostate Symptom Score (IPSS) de 10.8 pontos, da QoL de 1.5 pontos e do Internationl Index of Erectile Function (IIEF) de 2.1 pontos. Houve uma redução média do PSA de 30% (2.4 ng/mL), um aumento do pico de fluxo urinário (Qmax) de 3.1 - 3.85 mL/s e uma redução média do volume prostático de 21% (18.5 mL). Registou-se uma complicação major: pequena área de isquémia da parede vesical tratada cirurgicamente. Em 75% dos doentes tratados obteve-se sucesso clínico com franca melhoria dos sintomas, enquanto 25% dos doentes foram considerados insucesso clínico por se ter registado uma fraca ou ausente melhoria sintomática após a embolização. Os restantes doentes tratados estão sob controlo evolutivo, pararam toda a medicação prostática, sem qualquer caso de disfunção sexual associada com o tratamento. Este trabalho constitui o primeiro estudo anatómico descritivo in vivo das artérias prostáticas, conseguido devido à utilização de técnicas de imagem nunca usadas para este fim. O uso clínico dos dados anatómicos acima referidos permitiu a implementação de técnicas de Radiologia de Intervenção no tratatamento de uma doença de elevada prevalência. ------------------------------- ABSTRACT: Benign prostatic hyperplasia (BPH) has high prevalence in men aged 50–79 years being ubiquitous with aging. Due to significant morbi-mortality associated with currently available medical and surgical treatments, there is the need for innovative technologies to continue to improve outcomes and minimize patient discomfort and morbidity. Recently, prostatic arterial embolization (PAE) was suggested as a treatmentoption for BPH based on preliminary results from animal studies and 3 treated patients. We decided to investigate if PAE might be a successful treatment option for severely symptomatic BPH patients. We performed a clinical and anatomical-radiological study in 63 patients with the use of an inovative image-guided minimally invasive technique. We evaluated 126 pelvic sides using Angio-MR or Angio-CT and Catheter Angiography before embolisation to treat symptomatic BPH. We aimed to define the main branching patterns of the male internal iliac arteries, so far only studied in the cadaver. We also evaluated the prostatic arterial supply, identifying: 1 the prostatic arteries; 2 origin and direction; 3 intra-prostatic branches; 4 anastomoses with surrounding arteries. Regarding the anatomical study we identified 181 prostatic arteries, because in 43.7% of pelvic sides 2 separate prostatic vascular pedicles were found. The most frequent origin was the internal pudendal artery (39.7%) with the common glutealpudendal trunk (21%) and superior vesical arteries (18.2%) the next commonest. Less frequent origins were the obturator artery (12.1%), the inferior (3.9%) or superior (1.7%) gluteal arteries, rectal branches from the inferior mesenteric artery (1.7%) and the accessory pudendal artery (1.7%). There were anastomoses with the surrounding arteries in 57.9% of cases: termination of the internal pudendal artery (41.6%), contralateral prostatic arteries (18.2%), same-side prostatic arteries (11.7%), rectal branches (15.6%), and vesical arteries (12.9%).Regarding the clinical study, we treated 63 patients aged 52–82 years (mean 69.5 years) who presented with symptomatic BPH refractory to medical treatment for at least 6 months. Follow-up evaluation (mean 4.7 months, range 1-12 months) was possible in 37 patients. PAE was achieved in all patients with bilateral embolization in 73%. In 27% PAE was performed unilaterally due to tortuosity, atherosclerotic changes and small size of iliac and prostatic arteries. There was a mean decrease in the IPSS of 10.8 points, a mean improvement in QoL of 1.5 points, and a mean increase in the sexual function score of 2.1 points. There was a mean PSA reduction of 30% (2.4 ng/mL), a Qmax increase of 3.1 to 3.85 mL/sec, and a mean prostate volume decrease of 21% (18.5 mL). There was one major complication: a small area of bladder wall ischemia treated by surgery. Overall, 75% of patients were considered clinical success with major improvement after PAE, while 25% of patients were considered clinical failure with little or no improvement after PAE. All remaining patients are under follow-up, stopped all prostatic medication, and reported no sexual dysfunction. This study is the first one to describe the radiological anatomy of the prostatic arteries, with the use of imaging techniques never used for this purpose before. The clinical use of the anatomical findings allowed the implementation of Interventional Radiology tehniques in the treatment of a disease with a high prevalence.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enthesitis is the hallmark of spondyloarthritis and is observed in all subtypes. Namely, a wide information on spondyloarthritis abnormalities, including synovitis, bursitis, tendinitis, enthesitis and cortical bone abnormalities (erosions and enthesophytes), can be efficiently perceived by ultrasound power Doppler. Furthermore, several studies on imaging of enthesis showed that imaging techniques are better than clinical examination to detect pathology at asymptomatic enthesis. Vascularized enthesitis detected by ultrasound power Doppler appears to be a valuable diagnostic tool to confirm spondyloarthritis diagnosis. This article focuses on the validity and reliability of ultrasound enthesitis assessment in the management of spondyloarthritis patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO: Enthesitis is the hallmark of spondyloarthritis (SpA), and is observed in all subtypes. Wide information on SpA abnormalities, including synovitis, tendinitis and enthesitis, can be efficiently perceived by Doppler ultrasound. Furthermore, several studies on imaging of enthesis showed that imaging techniques are better than clinical examination to detect enthesis alterations; and vascularized enthesitis detected by Doppler ultrasound appears to be a valuable diagnostic tool to confirm SpA diagnosis. However, data published until now concerning entheseal elementary alterations that characterize SpA enthesitis (enthesis inflammatory activity) or enthesopathy (permanent structural changes) reflect rather the authors’ empiric opinion than a methodological validation process. In this sense it seems crucial to identify elementary entheseal lesions associated with activity or damage, in order to improve monitoring and treatment response in SpA patients. The development of better assessment tools is today a challenge and a need in SpA. The first study of this thesis focused on the analysis of the reliability of inter-lector and inter-ultrasonography equipment of Madrid sonography enthesitis index (MASEI). Fundamental data for the remaining unrolling project validity. In the second and third studies we concerned about two entheseal elemental lesions: erosions and bursa. In literature erosions represent a permanent structural damage, being useful for monitoring joint injury, disease activity and therapeutic response in many rheumatic diseases; and to date, this concept has been mostly applied in rheumatoid arthritis (RA). Unquestionably, erosion is a tissue-related damage and a structural change. However, the hypothesis that we decided to test was if erosions represent a permanent structural change that can only grow and worsen over time, as occurs in RA, or a transitory alteration. A longitudinal study of early SpA patients was undertaken, and the Achilles enthesis was used as a model. Our results strongly suggested that previously detected erosions could disappear during the course of the disease, being consistent with the dynamic behavior of erosion over time. Based on these striking results it seems reasonable to suggest that the new-bone formation process in SpA could be associated with the resolution of cortical entheseal erosion over time. These results could also be in agreement with the apparent failure of anti-tumor necrosis factor (TNF) therapies to control bone proliferation in SpA; and with the relation of TNF-α, Dickkopf-related protein 1 (Dkk-1) and the regulatory molecule of the Wnt signaling pathway in the bone proliferation in SpA. In the same model, we then proceeded to study the enthesis bursa. Interestingly, the Outcome Measures in Rheumatology Clinical Trials (OMERACT) enthesopathy definition does not include bursa as an elementary entheseal lesion. Nonetheless, bursa was included in 46% of the enthesis studies in a recently systematic literature review, being in agreement with the concept of “synovio-entheseal complex” that includes the link between enthesitis and osteitis in SpA. It has been clarified in recent data that there is not only a close functional integration of the enthesis with the neighboring bone, but also a connection between enthesitis and synovitis. Therefore, we tried to assess the prevalence and relevance of the bursa-synovial lesion in SpA. Our findings showed a significant increase of Achilles bursa presence and thickness in SpA patients compared to controls (healthy/mechanical controls and RA controls). These results raise awareness to the need to improve the enthesopathy ultrasonographic definition. In the final work of this thesis, we have explored new perspectives, not previously reported, about construct validity of enthesis ultrasound as a possible activity outcome in SpA. We performed a longitudinal Achilles enthesis ultrasound study in patients with early SpA. Achilles ultrasound examinations were performed at baseline, six- and twelve-month time periods and compared with clinical outcome measures collected at basal visit. Our results showed that basal erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) are higher in patients with Doppler signal in enthesis, and even that higher basal ESR, CRP and Ankylosing Spondylitis Disease Activity Score (ASDAS) predicted a higher Doppler signal (an ultrasound alteration accepted as representative of inflammation) six months later. Patients with very high disease activity assessed by ASDAS (>3.5) at baseline had significantly higher Achilles total ultrasound score verified at the same time; and ASDAS <1.3 predicted no Doppler signal at six and twelve months. This seems to represent a connection between classical biomarkers and clinical outcomes associated with SpA activity and Doppler signal, not only at the same time, but also for the following months. Remarkably, patients with inactive disease (ASDAS < 1.3) at baseline had no Doppler signal at six and twelve months. These findings reinforce the potential use of ultrasound related techniques for disease progression assessment and prognosis purposes. Intriguingly, Ankylosing Spondylitis Disease Activity Index (BASDAI) didn’t show significant differences between different cut-offs concerning ultrasound lesions or Doppler signal, while verified with ASDAS. These results seem to indicate that ASDAS reflects better than BASDAI what happens in the enthesis. The work herein discussed clearly shows the potential utility of ultrasound in enthesis assessment in SpA patients, and can be important for the development of ultrasound activity and structural damage scores for diagnosis and monitoring purposes. Therefore, local promotion of this technique constitutes a medical intervention that is worth being tested in SpA patients for diagnosis, monitoring and prognosis purposes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Non-invasive brain imaging techniques often contrast experimental conditions across a cohort of participants, obfuscating distinctions in individual performance and brain mechanisms that are better characterised by the inter-trial variability. To overcome such limitations, we developed topographic analysis methods for single-trial EEG data [1]. So far this was typically based on time-frequency analysis of single-electrode data or single independent components. The method's efficacy is demonstrated for event-related responses to environmental sounds, hitherto studied at an average event-related potential (ERP) level. Methods: Nine healthy subjects participated to the experiment. Auditory meaningful sounds of common objects were used for a target detection task [2]. On each block, subjects were asked to discriminate target sounds, which were living or man-made auditory objects. Continuous 64-channel EEG was acquired during the task. Two datasets were considered for each subject including single-trial of the two conditions, living and man-made. The analysis comprised two steps. In the first part, a mixture of Gaussians analysis [3] provided representative topographies for each subject. In the second step, conditional probabilities for each Gaussian provided statistical inference on the structure of these topographies across trials, time, and experimental conditions. Similar analysis was conducted at group-level. Results: Results show that the occurrence of each map is structured in time and consistent across trials both at the single-subject and at group level. Conducting separate analyses of ERPs at single-subject and group levels, we could quantify the consistency of identified topographies and their time course of activation within and across participants as well as experimental conditions. A general agreement was found with previous analysis at average ERP level. Conclusions: This novel approach to single-trial analysis promises to have impact on several domains. In clinical research, it gives the possibility to statistically evaluate single-subject data, an essential tool for analysing patients with specific deficits and impairments and their deviation from normative standards. In cognitive neuroscience, it provides a novel tool for understanding behaviour and brain activity interdependencies at both single-subject and at group levels. In basic neurophysiology, it provides a new representation of ERPs and promises to cast light on the mechanisms of its generation and inter-individual variability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Three-dimensional segmented echo planar imaging (3D-EPI) is a promising approach for high-resolution functional magnetic resonance imaging, as it provides an increased signal-to-noise ratio (SNR) at similar temporal resolution to traditional multislice 2D-EPI readouts. Recently, the 3D-EPI technique has become more frequently used and it is important to better understand its implications for fMRI. In this study, the temporal SNR characteristics of 3D-EPI with varying numbers of segments are studied. It is shown that, in humans, the temporal variance increases with the number of segments used to form the EPI acquisition and that for segmented acquisitions, the maximum available temporal SNR is reduced compared to single shot acquisitions. This reduction with increased segmentation is not found in phantom data and thus likely due to physiological processes. When operating in the thermal noise dominated regime, fMRI experiments with a motor task revealed that the 3D variant outperforms the 2D-EPI in terms of temporal SNR and sensitivity to detect activated brain regions. Thus, the theoretical SNR advantage of a segmented 3D-EPI sequence for fMRI only exists in a low SNR situation. However, other advantages of 3D-EPI, such as the application of parallel imaging techniques in two dimensions and the low specific absorption rate requirements, may encourage the use of the 3D-EPI sequence for fMRI in situations with higher SNR.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

While the overall incidence of myocardial infarction (MI) has been decreasing since 2000 [1], there is an increasing number of younger patients presenting with MI [2]. Few studies have focused on MI in very young patients, aged 35 years or less, as they only account for a minority of all patients with myocardial infarction [3]. According to the age category, MI differs in presentation, treatment and outcome, as illustrated in table 1. Echocardiography is considered mandatory according to scientific guidelines in the management and diagnosis of MI [4,5,6]. However, new imaging techniques such as cardiac magnetic resonance (CMR) and computed tomography (CT) are increasingly performed and enable further refinement of the diagnosis of MI. These techniques allow, in particular, precise location and quantification of MI. In this case, MI was located to the septum, which is an unusual presentation of MI. The incidence of pulmonary embolism (PE) has also increased in young patients over the past years [7]. Since symptoms and signs of PE may be non-specific, establishing its diagnosis remains a challenge [8]. Therefore, PE is one of the most frequently missed diagnosis in clinical medicine. Because of the widespread use of CT and its improved visualization of pulmonary arteries, PE may be discovered incidentally [9]. In the absence of a congenital disorder, multiple and/or simultaneous disease presentation is uncommon in the young. We report the rare case of a 35 year old male with isolated septal MI and simultaneous PE. The diagnosis of this rare clinical entity was only possible by means of newer imaging techniques.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cette thèse porte sur l’amélioration des techniques d’imagerie à haut-contraste permettant la détection directe de compagnons à de faibles séparations de leur étoile hôte. Plus précisément, elle s’inscrit dans le développement du Gemini Planet Imager (GPI) qui est un instrument de deuxième génération pour les télescopes Gemini. Cette caméra utilisera un spectromètre à champ intégral (SCI) pour caractériser les compagnons détectés et pour réduire le bruit de tavelure limitant leur détection et corrigera la turbulence atmosphérique à un niveau encore jamais atteint en utilisant deux miroirs déformables dans son système d’optique adaptative (OA) : le woofer et le tweeter. Le woofer corrigera les aberrations de basses fréquences spatiales et de grandes amplitudes alors que le tweeter compensera les aberrations de plus hautes fréquences ayant une plus faible amplitude. Dans un premier temps, les performances pouvant être atteintes à l’aide des SCIs présentement en fonction sur les télescopes de 8-10 m sont investiguées en observant le compagnon de l’étoile GQ Lup à l’aide du SCI NIFS et du système OA ALTAIR installés sur le télescope Gemini Nord. La technique de l’imagerie différentielle angulaire (IDA) est utilisée pour atténuer le bruit de tavelure d’un facteur 2 à 6. Les spectres obtenus en bandes JHK ont été utilisés pour contraindre la masse du compagnon par comparaison avec les prédictions des modèles atmosphériques et évolutifs à 8−60 MJup, où MJup représente la masse de Jupiter. Ainsi, il est déterminé qu’il s’agit plus probablement d’une naine brune que d’une planète. Comme les SCIs présentement en fonction sont des caméras polyvalentes pouvant être utilisées pour plusieurs domaines de l’astrophysique, leur conception n’a pas été optimisée pour l’imagerie à haut-contraste. Ainsi, la deuxième étape de cette thèse a consisté à concevoir et tester en laboratoire un prototype de SCI optimisé pour cette tâche. Quatre algorithmes de suppression du bruit de tavelure ont été testés sur les données obtenues : la simple différence, la double différence, la déconvolution spectrale ainsi qu’un nouvel algorithme développé au sein de cette thèse baptisé l’algorithme des spectres jumeaux. Nous trouvons que l’algorithme des spectres jumeaux est le plus performant pour les deux types de compagnons testés : les compagnons méthaniques et non-méthaniques. Le rapport signal-sur-bruit de la détection a été amélioré d’un facteur allant jusqu’à 14 pour un compagnon méthanique et d’un facteur 2 pour un compagnon non-méthanique. Dernièrement, nous nous intéressons à certains problèmes liés à la séparation de la commande entre deux miroirs déformables dans le système OA de GPI. Nous présentons tout d’abord une méthode utilisant des calculs analytiques et des simulations Monte Carlo pour déterminer les paramètres clés du woofer tels que son diamètre, son nombre d’éléments actifs et leur course qui ont ensuite eu des répercussions sur le design général de l’instrument. Ensuite, le système étudié utilisant un reconstructeur de Fourier, nous proposons de séparer la commande entre les deux miroirs dans l’espace de Fourier et de limiter les modes transférés au woofer à ceux qu’il peut précisément reproduire. Dans le contexte de GPI, ceci permet de remplacer deux matrices de 1600×69 éléments nécessaires pour une séparation “classique” de la commande par une seule de 45×69 composantes et ainsi d’utiliser un processeur prêt à être utilisé plutôt qu’une architecture informatique plus complexe.