993 resultados para Hybrid working machines
Resumo:
The reconstruction of power industries has brought fundamental changes to both power system operation and planning. This paper presents a new planning method using multi-objective optimization (MOOP) technique, as well as human knowledge, to expand the transmission network in open access schemes. The method starts with a candidate pool of feasible expansion plans. Consequent selection of the best candidates is carried out through a MOOP approach, of which multiple objectives are tackled simultaneously, aiming at integrating the market operation and planning as one unified process in context of deregulated system. Human knowledge has been applied in both stages to ensure the selection with practical engineering and management concerns. The expansion plan from MOOP is assessed by reliability criteria before it is finalized. The proposed method has been tested with the IEEE 14-bus system and relevant analyses and discussions have been presented.
Resumo:
Brain electrical activity related to working memory was recorded at 15 scalp electrodes during a visuospatial delayed response task. Participants (N = 18) touched the remembered position of a target on a computer screen after either a 1 or 8 sec delay. These memory trials were compared to sensory trials in which the target remained present throughout the delay and response periods. Distracter stimuli identical to the target were briefly presented during the delay on 30% of trials. Responses were less accurate in memory than sensory trials, especially after the long delay. During the delay slow potentials developed that were significantly more negative in memory than sensory trials. The difference between memory and sensory trials was greater at anterior than posterior electrodes. On trials with distracters, the slow potentials generated by memory trials showed further enhancement of negativity whereas there were minimal effects on accuracy of performance. The results provide evidence that engagement of visuospatial working memory generates slow wave negativity with a timing and distribution consistent with frontal activation. Enhanced brain activity associated with working memory is required to maintain performance in the presence of distraction. © 1997 by the Massachusetts Institute of Technology
Resumo:
Baekground: Patients with schizophrenia tend to have impaired performance on tests of working memory (WM). Neurocognitive models have linked WM to certain symptoms of schizophrenia. This study aimed to assess WM in schizophrenia and mania in the acute and subacute phases of the illness and explore correlations between WM and symptom clusters. Methods: A visuo-spatial delayed response task was used to assess WM in schizophrenia (n=20), mania (n= 14) and well controls (n=20). Patients were tested during the first week of an acute admission, and subjects were retested after four weeks. WM, symptoms (PANSS, TLC) and executive ability (COWAT, Stroop, Trail Making) were assessed at both time points. Results: When assessed for overall WM errors (both sensory and memory), there was a significant group difference (F- 11.53, df 2, 40; p
Resumo:
This paper presents general considerations for working with athletes with disabilities and the usefulness and possible modification of specific mental skills for those athletes. Common concerns for athletes with specific disabilities are discussed. Specific disabilities are considered under the headings of amputees, blind and visually impaired, cerebral palsy, deaf and hearing impaired, intellectual disabilities, and wheelchair. Arousal control, goal setting, attention/concentration, body awareness, imagery, self-confidence, and precompetition preparation are discussed in terms of disability-specific issues as well as suggestions for application.
Abnormal neuronal circuitry for switching of attention and working memory in schizophrenic patients.
Resumo:
Previous work on generating state machines for the purpose of class testing has not been formally based. There has also been work on deriving state machines from formal specifications for testing non-object-oriented software. We build on this work by presenting a method for deriving a state machine for testing purposes from a formal specification of the class under test. We also show how the resulting state machine can be used as the basis for a test suite developed and executed using an existing framework for class testing. To derive the state machine, we identify the states and possible interactions of the operations of the class under test. The Test Template Framework is used to formally derive the states from the Object-Z specification of the class under test. The transitions of the finite state machine are calculated from the derived states and the class's operations. The formally derived finite state machine is transformed to a ClassBench testgraph, which is used as input to the ClassBench framework to test a C++ implementation of the class. The method is illustrated using a simple bounded queue example.
Resumo:
This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.
Resumo:
This paper describes a hybrid numerical method of an inverse approach to the design of compact magnetic resonance imaging magnets. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first, kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. The emphasis of this work is on the optimal design of short MRI magnets. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric MRI magnets as well as asymmetric magnets. The results highlight that the method can be used to obtain a compact MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1 m in length, significantly shorter than current designs. Viable asymmetric magnet designs, in which the edge of the homogeneous region is very close to one end of the magnet system are also presented. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00303-5].
Resumo:
A hybrid formulation for coupled pore fluid-solid deformation problems is proposed. The scheme is a hybrid in the sense that we use a vertex centered finite volume formulation for the analysis of the pore fluid and a particle method for the solid in our model. The pore fluid formally occupies the same space as the solid particles. The size of the particles is not necessarily equal to the physical size of materials. A finite volume mesh for the pore fluid flow is generated by Delaunay triangulation. Each triangle possesses an initial porosity. Changes of the porosity are specified by the translations of the mass centers of particles. Net pore pressure gradients are applied to the particle centers and are considered in the particle momentum balance. The potential of our model is illustrated by means of a simulation of coupled fracture and fluid flow developed in porous rock under biaxial compression condition.