911 resultados para Housing, Single family -- Environmetal aspects -- Valldemosa (Spain)
Resumo:
the work towards increased energy efficiency. In order to plan and perform effective energy renovation of the buildings, it is necessary to have adequate information on the current status of the buildings in terms of architectural features and energy needs. Unfortunately, the official statistics do not include all of the needed information for the whole building stock. This paper aims to fill the gaps in the statistics by gathering data from studies, projects and national energy agencies, and by calibrating TRNSYS models against the existing data to complete missing energy demand data, for countries with similar climate, through simulation. The survey was limited to residential and office buildings in the EU member states (before July 2013). This work was carried out as part of the EU FP7 project iNSPiRe. The building stock survey revealed over 70% of the residential and office floor area is concentrated in the six most populated countries. The total energy consumption in the residential sector is 14 times that of the office sector. In the residential sector, single family houses represent 60% of the heated floor area, albeit with different share in the different countries, indicating that retrofit solutions cannot be focused only on multi-family houses. The simulation results indicate that residential buildings in central and southern European countries are not always heated to 20 °C, but are kept at a lower temperature during at least part of the day. Improving the energy performance of these houses through renovation could allow the occupants to increase the room temperature and improve their thermal comfort, even though the potential for energy savings would then be reduced.
Resumo:
This research has as its object study focus bioclimatic in architecture and its conection with projects decisions, on what regards to environmental comfort for single-family dwelling. From the analysis of five architectural projects inserted in Natal/RN, warm-moist weather, this research gather informations regarding architectural features guided by shape and space arrengement, which embody important elements for the project design development. Computer simulations assisted as foundation to verify the efficiency grade for these projects strategies from shading analysis. Related strategies for the demands of natural ventilation circulation and thermal mass for refrigeration were analysed as well. Results show that there is an hierarchizing of priorities for the decisions made when it comes to shape and space disposition variables, as well as the way these variables will consider the bioclimatic demands. The analysis, even, show that there is no single way to respond to specific bioclimatic demands, as it points out the value of examination of the projectual solutions throughtout the conception process, in order to achieve an efficient project performance for the envimonment comfort
Resumo:
Assuming that the form of a building shell and its content the spatial form are distinct dimensions of architecture - however indivisible and interdependent -, this study focus, in the light of the Social Logic of Space (HILLIER; HANSON, 1984), on the intrinsic properties through which domestic space was structured in a sample of single-family dwellings built in João Pessoa (PB) during the 1970s - when the vocabulary of modern architecture still prevailed in Brazil though sharing the urban scene with other architectural trends -, in order to investigate regularities or divergences underlying their conception. These dwellings were originally classified (ARAÚJO, 2010a) in five categories defined according to the form of their building shells and to their prevailing construction techniques: (1) Brazilian modern legacy (considered as truly Brazilian modern style); (2) Paulista architecture (that refers to the modern production of São Paulo, Brazil, from the 1950s through the 1970s); (3) experiences of rationalization and prefabrication ; (4) experiences of adaptation to the climate (referring to a design strongly influenced by the hot and humid climate of North-eastern Brazil); and (5) hybrid (to account for a kind of stylistic hybridism that includes formal attributes, which evoke our colonial past). This study aims to determine, through the analyses of nineteen cases that represent each category, whether this taxonomy corresponds to distinct modes of spatial configuration. This research therefore proposes an approach to the classification of domestic architecture based on topological properties. The dwellings spatial organization was represented, quantified and analyzed, their spatial properties explored in consonance with one another and with the literature. Results pointed out that there is no evidence of a reciprocal relationship between the formal look of the built shells and their respective spatial structures
Resumo:
This research has as its object study focus bioclimatic in architecture and its conection with projects decisions, on what regards to environmental comfort for single-family dwelling. From the analysis of five architectural projects inserted in Natal/RN, warm-moist weather, this research gather informations regarding architectural features guided by shape and space arrengement, which embody important elements for the project design development. Computer simulations assisted as foundation to verify the efficiency grade for these projects strategies from shading analysis. Related strategies for the demands of natural ventilation circulation and thermal mass for refrigeration were analysed as well. Results show that there is an hierarchizing of priorities for the decisions made when it comes to shape and space disposition variables, as well as the way these variables will consider the bioclimatic demands. The analysis, even, show that there is no single way to respond to specific bioclimatic demands, as it points out the value of examination of the projectual solutions throughtout the conception process, in order to achieve an efficient project performance for the envimonment comfort
Resumo:
Assuming that the form of a building shell and its content the spatial form are distinct dimensions of architecture - however indivisible and interdependent -, this study focus, in the light of the Social Logic of Space (HILLIER; HANSON, 1984), on the intrinsic properties through which domestic space was structured in a sample of single-family dwellings built in João Pessoa (PB) during the 1970s - when the vocabulary of modern architecture still prevailed in Brazil though sharing the urban scene with other architectural trends -, in order to investigate regularities or divergences underlying their conception. These dwellings were originally classified (ARAÚJO, 2010a) in five categories defined according to the form of their building shells and to their prevailing construction techniques: (1) Brazilian modern legacy (considered as truly Brazilian modern style); (2) Paulista architecture (that refers to the modern production of São Paulo, Brazil, from the 1950s through the 1970s); (3) experiences of rationalization and prefabrication ; (4) experiences of adaptation to the climate (referring to a design strongly influenced by the hot and humid climate of North-eastern Brazil); and (5) hybrid (to account for a kind of stylistic hybridism that includes formal attributes, which evoke our colonial past). This study aims to determine, through the analyses of nineteen cases that represent each category, whether this taxonomy corresponds to distinct modes of spatial configuration. This research therefore proposes an approach to the classification of domestic architecture based on topological properties. The dwellings spatial organization was represented, quantified and analyzed, their spatial properties explored in consonance with one another and with the literature. Results pointed out that there is no evidence of a reciprocal relationship between the formal look of the built shells and their respective spatial structures
Resumo:
Property taxes serve as a vital revenue source for local governments. The revenues derived from the property tax function as the primary funding source for a variety of critical local public service systems. Property tax appeal systems serve as quasi-administrative-judicial mechanisms intended to assure the public that property tax assessments are correct, fair, and equitable. Despite these important functions, there is a paucity of empirical research related to property tax appeal systems. This study contributes to property tax literature by identifying who participates in the property tax appeal process and examining their motivations for participation. In addition, the study sought to determine whether patterns of use and success in appeal systems affected the distribution of the tax burden. Data were collected by means of a survey distributed to single-family property owners from two Florida counties. In addition, state and county documents were analyzed to determine appeal patterns and examine the impact on assessment uniformity, over a three-year period. The survey data provided contextual evidence that single-family property owners are not as troubled by property taxes as they are by the conduct of local government officials. The analyses of the decision to appeal indicated that more expensive properties and properties excluded from initial uniformity analyses were more likely to be appealed, while properties with homestead exemptions were less likely to be appealed. The value change analyses indicated that appeals are clustered in certain geographical areas; however, these areas do not always experience a greater percentage of the value changes. Interestingly, professional representation did not increase the probability of obtaining a reduction in value. Other relationships between the variables were discovered, but often with weak predictive ability. Findings from the assessment uniformity analyses were also interesting. The results indicated that the appeals mechanisms in both counties improved assessment uniformity. On average, appealed properties exhibited greater horizontal and vertical inequities, as compared to non-appealed properties, prior to the appeals process. After, the appeal process was completed; the indicators of horizontal and vertical equity were largely improved. However, there were some indications of regressivity in the final year of the study.
Resumo:
Performance testing methods of boilers in transient operating conditions (start, stop and combustion power modulation sequences) need the combustion rate quantified to allow for the emissions to be quantified. One way of quantifying the combustion rate of a boiler during transient operating conditions is by measuring the flue gas flow rate. The flow conditions in chimneys of single family house boilers pose a challenge however, mainly because of the low flow velocity. The main objectives of the work were to characterize the flow conditions in residential chimneys, to evaluate the use of the Pitot-static method and the averaging Pitot method, and to develop and test a calibration method for averaging Pitot probes for low
Resumo:
Accounting for around 40% of the total final energy consumption, the building stock is an important area of focus on the way to reaching the energy goals set for the European Union. The relatively small share of new buildings makes renovation of existing buildings possibly the most feasible way of improving the overall energy performance of the building stock. This of course involves improvements on the climate shell, for example by additional insulation or change of window glazing, but also installation of new heating systems, to increase the energy efficiency and to fit the new heat load after renovation. In the choice of systems for heating, ventilation and air conditioning (HVAC), it is important to consider their performance for space heating as well as for domestic hot water (DHW), especially for a renovated house where the DHW share of the total heating consumption is larger. The present study treats the retrofitting of a generic single family house, which was defined as a reference building in a European energy renovation project. Three HVAC retrofitting options were compared from a techno-economic point of view: A) Air-to-water heat pump (AWHP) and mechanical ventilation with heat recovery (MVHR), B) Exhaust air heat pump (EAHP) with low-temperature ventilation radiators, and C) Gas boiler and ventilation with MVHR. The systems were simulated for houses with two levels of heating demand and four different locations: Stockholm, Gdansk, Stuttgart and London. They were then evaluated by means of life cycle cost (LCC) and primary energy consumption. Dynamic simulations were done in TRNSYS 17. In most cases, system C with gas boiler and MVHR was found to be the cheapest retrofitting option from a life cycle perspective. The advantage over the heat pump systems was particularly clear for a house in Germany, due to the large discrepancy between national prices of natural gas and electricity. In Sweden, where the price difference is much smaller, the heat pump systems had almost as low or even lower life cycle costs than the gas boiler system. Considering the limited availability of natural gas in Sweden, systems A and B would be the better options. From a primary energy point of view system A was the best option throughout, while system B often had the highest primary energy consumption. The limited capacity of the EAHP forced it to use more auxiliary heating than the other systems did, which lowered its COP. The AWHP managed the DHW load better due to a higher capacity, but had a lower COP than the EAHP in space heating mode. Systems A and C were notably favoured by the air heat recovery, which significantly reduced the heating demand. It was also seen that the DHW share of the total heating consumption was, as expected, larger for the house with the lower space heating demand. This confirms the supposition that it is important to include DHW in the study of HVAC systems for retrofitting.
Resumo:
In this paper, dynamic simulation was used to compare the energy performance of three innovativeHVAC systems: (A) mechanical ventilation with heat recovery (MVHR) and micro heat pump, (B) exhaustventilation with exhaust air-to-water heat pump and ventilation radiators, and (C) exhaust ventilationwith air-to-water heat pump and ventilation radiators, to a reference system: (D) exhaust ventilation withair-to-water heat pump and panel radiators. System A was modelled in MATLAB Simulink and systems Band C in TRNSYS 17. The reference system was modelled in both tools, for comparison between the two.All systems were tested with a model of a renovated single family house for varying U-values, climates,infiltration and ventilation rates.It was found that A was the best system for lower heating demand, while for higher heating demandsystem B would be preferable. System C was better than the reference system, but not as good as A or B.The difference in energy consumption of the reference system was less than 2 kWh/(m2a) betweenSimulink and TRNSYS. This could be explained by the different ways of handling solar gains, but also bythe fact that the TRNSYS systems supplied slightly more than the ideal heating demand.
Resumo:
The city of Iowa city is continually working to improve the community's recycling services and options. The city services about 15,000 households, single family home and multifamily homes with four units or fewer with curbside pick ups of refuse, dual-stream recycling and yard waste as well as electronics and bulky waste by appointment.
Resumo:
Abstract Background The etiology of idiopathic scoliosis remains unknown and different factors have been suggested as causal. Hereditary factors can also determine the etiology of the disease; however, the pattern of inheritance remains unknown. Autosomal dominant, X-linked and multifactorial patterns of inheritances have been reported. Other studies have suggested possible chromosome regions related to the etiology of idiopathic scoliosis. We report the genetic aspects of and investigate chromosome regions for adolescent idiopathic scoliosis in a Brazilian family. Methods Evaluation of 57 family members, distributed over 4 generations of a Brazilian family, with 9 carriers of adolescent idiopathic scoliosis. The proband presented a scoliotic curve of 75 degrees, as determined by the Cobb method. Genomic DNA from family members was genotyped. Results Locating a chromosome region linked to adolescent idiopathic scoliosis was not possible in the family studied. Conclusion While it was not possible to determine a chromosome region responsible for adolescent idiopathic scoliosis by investigation of genetic linkage using microsatellites markers during analysis of four generations of a Brazilian family with multiple affected members, analysis including other types of genomic variations, like single nucleotide polymorphisms (SNPs) could contribute to the continuity of this study.
Resumo:
This paper analyzes the production of apartment buildings for the middle-income segment in the city of So Paulo, Brazil, from a historical perspective. Tracing the response to the occupants` needs, the focus is on family profiles and their demands, the relationship between architectural design and marketing, and satisfaction levels of current users. The paper begins with a brief historical overview of how apartment buildings have evolved over the past eight decades, highlighting the consolidation of the tripartite model. Next, it analyzes family profiles and their current needs, which would call for a redesign of domestic space. From a different angle, it shows how the real-estate market reacts to this situation, namely by introducing minor changes in the domestic space that are closely linked to major investments in marketing. This leads to a discussion on the quality of recent architectural designs in light of Post-Occupancy Evaluation (POE) case studies, which corroborate the tendencies previously outlined. The conclusions drawn from the POEs suggest that the market should establish a closer and deeper relationship between the assessment of the human behavior in the domestic space and the architectural quality of homes as a means of increasing satisfaction levels and improving design performance.
Resumo:
This pilot project at Cotton Tree, Maroochydore, on two adjacent, linear parcels of land has one of the properties privately owned while the other is owned by the public housing authority. Both owners commissioned Lindsay and Kerry Clare to design housing for their separate needs which enabled the two projects to be governed by a single planning and design strategy. This entailed the realignment of the dividing boundary to form two approximately square blocks which made possible the retention of an important stand of mature paperbark trees and gave each block a more useful street frontage. The scheme provides seven two-bedroom units and one single-bedroom unit as the private component, with six single-bedroom units, three two-bedroom units and two three-bedroom units forming the public housing. The dwellings are deployed as an interlaced mat of freestanding blocks, car courts, courtyard gardens, patios and decks. The key distinction between the public and private parts of the scheme is the pooling of the car parking spaces in the public housing to create a shared courtyard. The housing climbs to three storeys on its southern edge and falls to a single storey on the north-western corner. This enables all units and the principal private outdoor spaces to have a northern orientation. The interiors of both the public and private units are skilfully arranged to take full advantage of views, light and breeze.
Resumo:
Background: Hereditary angioedema is an autosomal dominant disease characterized by episodes of subcutaneous and submucosal edema. It is caused by deficiency of the C1 inhibitor protein, leading to elevated levels of bradykinin. More than 200 mutations in C1 inhibitor gene have been reported. The aim of this study was to analyze clinical features of a large family with an index case of hereditary angioedema and to determine the disease-causing mutation in this family. Methods: Family pedigree was constructed with 275 individuals distributed in five generations. One hundred and sixty-five subjects were interviewed and investigated for mutation at the C1 inhibitor gene. Subjects reporting a history of recurrent episodes of angioedema and/or abdominal pain attacks underwent evaluation for hereditary angioedema. Results: We have identified a novel mutation at the C1 inhibitor gene, c.351delC, which is a single-nucleotide deletion of a cytosine on exon 3, resulting in frameshift with premature stop codon. Sequencing analysis of the hypothetical truncated C1 inhibitor protein allowed us to conclude that, if transcription occurs, this protein has no biological activity. Twenty-eight members of the family fulfilled diagnostic criteria for hereditary angioedema and all of them presented the c.351delC mutation. Variation in clinical presentation and severity of disease was observed among these patients. One hundred and thirty-seven subjects without hereditary angioedema did not have the c.351delC mutation. Conclusion: The present study provides definitive evidence to link a novel genetic mutation to the development of hereditary angioedema in patients from a Brazilian family.
Resumo:
The authors observed an injury caused by the sting of a false tocandira ant in the hand of an amateur fisherman and they describe the clinical findings and the evolution of the envenoming, which presented an acute and violent pain, cold sweating, nausea, a vomiting episode, malaise, tachycardia and left axillary's lymphadenopathy. About three hours after the accident, still feeling intense pain in the place of the sting, he presented an episode of great amount of blood in the feces with no history of digestive, hematological or vascular problems. The intense pain decreased after eight hours, but the place stayed moderately painful for about 24 hours. In that moment, he presented small grade of local edema and erythema. The authors still present the folkloric, pharmacological and clinical aspects related to the tocandiras stings, a very interesting family of ants, which presents the largest and more venomous ants of the world.