216 resultados para HOA microphone


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A path integral simulation algorithm which includes a higher-order Trotter approximation (HOA)is analyzed and compared to an approach which includes the correct quantum mechanical pair interaction (effective Propagator (EPr)). It is found that the HOA algorithmconverges to the quantum limit with increasing Trotter number P as P^{-4}, while the EPr algorithm converges as P^{-2}.The convergence rate of the HOA algorithm is analyzed for various physical systemssuch as a harmonic chain,a particle in a double-well potential, gaseous argon, gaseous helium and crystalline argon. A new expression for the estimator for the pair correlation function in the HOA algorithm is derived. A new path integral algorithm, the hybrid algorithm, is developed.It combines an exact treatment of the quadratic part of the Hamiltonian and thehigher-order Trotter expansion techniques.For the discrete quantum sine-Gordon chain (DQSGC), it is shown that this algorithm works more efficiently than all other improved path integral algorithms discussed in this work. The new simulation techniques developed in this work allow the analysis of theDQSGC and disordered model systems in the highly quantum mechanical regime using path integral molecular dynamics (PIMD)and adiabatic centroid path integral molecular dynamics (ACPIMD).The ground state phonon dispersion relation is calculated for the DQSGC by the ACPIMD method.It is found that the excitation gap at zero wave vector is reduced by quantum fluctuations. Two different phases exist: One phase with a finite excitation gap at zero wave vector, and a gapless phase where the excitation gap vanishes.The reaction of the DQSGC to an external driving force is analyzed at T=0.In the gapless phase the system creeps if a small force is applied, and in the phase with a gap the system is pinned. At a critical force, the systems undergo a depinning transition in both phases and flow is induced. The analysis of the DQSGC is extended to models with disordered substrate potentials. Three different cases are analyzed: Disordered substrate potentials with roughness exponent H=0, H=1/2,and a model with disordered bond length. For all models, the ground state phonon dispersion relation is calculated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atmosphärische Aerosolpartikel haben einen Einfluss sowohl auf das Klima als auch auf die menschliche Gesundheit, wobei sowohl die Größe, als auch die chemische Zusammensetzung der Partikel maßgeblich sind. Um insbesondere die chemische Zusammensetzung der Partikel in Abhängigkeit ihrer Quellen besser zu verstehen, wurden im Rahmen dieser Arbeit massenspektrometrische Untersuchungen thermisch verdampfbarer Partikel im Submikrometerbereich durchgeführt. Hierzu wurden sowohl die Massenspektren einzelner Partikel, als auch die von Ensembles von Partikeln mit dem Aerodyne Aerosolmassenspektrometer (AMS) in mehreren Feldmesskampagnen untersucht. Für die Messung von Einzelpartikelmassenspektren wurde das AMS zunächst durch den Einbau eines optischen Partikeldetektors (light scattering probe) modifiziert und anschließend eingehend charakterisiert. Dabei wurde festgestellt, dass mit dem Gerät im Partikelgrößenbereich von etwa 400-750 nm (untere Grenze bedingt durch die Detektionseffizienz des optischen Detektors, obere Grenze durch die Transmissionseffizienz des Aerosoleinlasssystems) quantitative Einzelpartikelmessungen möglich sind. Zudem wurde die Analyse der erhaltenen Messdaten systematisiert, und durch Einsatz von Standardspektren ein Sortieralgorithmus für die Einzelpartikelmassenspektren entwickelt, der erfolgreich auf Daten von Feldmesskampagnen angewandt werden konnte. Mit diesem Sortieralgorithmus sind zudem quantitative Aussagen über die verschiedenen Partikelbestandteile möglich. Im Sommer 2009 und im Winter 2010 fanden im Großraum Paris zwei einmonatige Feldmesskampagnen statt, bei denen unter anderem der Einfluss der Abluftfahne der Megastadt auf seine Vororte untersucht wurde. Erhöhte Konzentrationen sekundär gebildeter Aerosolkomponenten (Nitrat, Sulfat, oxidiertes organisches Aerosol (OOA)) waren insbesondere beim Herantransport kontinentaler Luftmassen zu beobachten. Im Gegensatz dazu waren die beobachteten Konzentrationen der Tracer primärer Emissionen NOx, BC (black carbon) und HOA (hydrocarbonlike organic aerosol) neben der lokalen Quellstärke insbesondere durch die herrschende Windgeschwindigkeit beeinflusst. Aus dem Vergleich der Messungen an drei Stationen konnte der Einfluss der Megastadt Paris auf seine Vororte (unter Annahme gleicher lokaler Emissionen an den zwei Vorort-Stationen) zu 0,1-0,7 µg m-3 BC, 0,3-1,1 µg m-3 HOA, und 3-5 ppb NOx abgeschätzt werden. Zudem konnten für zwei Stationen aus den Ensemble- bzw. den Einzelpartikelmessungen unabhängig voneinander zwei verschiedene HOA-Typen unterschieden werden, die den Quellen „Kochen“ und „Autoabgase“ zugeordnet wurden. Der Anteil der Partikel aus den Quellen „Kochen“ bzw. „Autoabgase“ am Gesamt-HOA betrug 65,5 % und 34,5 % für die Ensemblemessungen in der Innenstadt (nahe vieler Restaurants), und für die Einzelpartikelmessungen in einem Vorort 59 % bzw. 41 % (bezogen auf die Partikelanzahl, welche hier der Masse etwa proportional ist). Die Analyse der Einzelpartikelmassenspektren erbrachte zudem neue Erkenntnisse über den Mischungszustand der Einzelpartikel. So konnte belegt werden, dass Nitrat, Sulfat und OOA intern gemischt sind, HOA-Partikel aber als externe Mischung mit diesen vorliegen. Zudem konnte anhand der Tagesgänge der Masse pro Partikel von OOA, Nitrat und Sulfat und der Anzahl der diese Substanzen enthaltenden Partikel gezeigt werden, dass der im Ensemblemodus beobachtete fehlende Tagesgang der Sulfat-Massenkonzentration wahrscheinlich durch die gegensätzlichen Effekte der Modulation der Partikelanzahlkonzentration durch die sich verändernde Mischungsschichthöhe und der variierenden Masse an Sulfat pro Partikel (mittägliche photochemische Neuproduktion und Kondensation auf existierende Partikel) erklärt werden kann. Für OOA ist eine ähnliche Erklärung des Ensemblemodus-Tagesganges jedoch nur teilweise möglich; weitere Arbeit ist daher nötig, um auch für diese Substanzklasse belastbare Aussagen aus dem Vergleich der Ensemble- und Einzelpartikelmessungen zu erhalten. Im Rahmen einer Labormesskampagne an der AIDA-Kammer in Karlsruhe wurden Ensemble- und Einzelpartikelmassenspektren von Bakterien aufgenommen. Es konnte gezeigt werden, dass es prinzipiell möglich ist, Bakterien in Außenluft mittels Einzelpartikelmessungen nachzuweisen, jedoch wahrscheinlich nur bei sehr hohen Anzahlkonzentrationen. Der Nachweis von Bakterien und anderen primären biologischen Aerosolpartikeln mit dem AMS sollte daher in weiterführenden Experimenten noch optimiert werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The level of improvement in the audiological results of Baha(®) users mainly depends on the patient's preoperative hearing thresholds and the type of Baha sound processor used. This investigation shows correlations between the preoperative hearing threshold and postoperative aided thresholds and audiological results in speech understanding in quiet of 84 Baha users with unilateral conductive hearing loss, bilateral conductive hearing loss and bilateral mixed hearing loss. Secondly, speech understanding in noise of 26 Baha users with different Baha sound processors (Compact, Divino, and BP100) is investigated. Linear regression between aided sound field thresholds and bone conduction (BC) thresholds of the better ear shows highest correlation coefficients and the steepest slope. Differences between better BC thresholds and aided sound field thresholds are smallest for mid-frequencies (1 and 2 kHz) and become larger at 0.5 and 4 kHz. For Baha users, the gain in speech recognition in quiet can be expected to lie in the order of magnitude of the gain in their hearing threshold. Compared to its predecessor sound processors Baha(®) Compact and Baha(®) Divino, Baha(®) BP100 improves speech understanding in noise significantly by +0.9 to +4.6 dB signal-to-noise ratio, depending on the setting and the use of directional microphone. For Baha users with unilateral and bilateral conductive hearing loss and bilateral mixed hearing loss, audiological results in aided sound field thresholds can be estimated with the better BC hearing threshold. The benefit in speech understanding in quiet can be expected to be similar to the gain in their sound field hearing threshold. The most recent technology of Baha sound processor improves speech understanding in noise by an order of magnitude that is well perceived by users and which can be very useful in everyday life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONCLUSIONS: Speech understanding is better with the Baha Divino than with the Baha Compact in competing noise from the rear. No difference was found for speech understanding in quiet. Subjectively, overall sound quality and speech understanding were rated better for the Baha Divino. OBJECTIVES: To compare speech understanding in quiet and in noise and subjective ratings for two different bone-anchored hearing aids: the recently developed Baha Divino and the Baha Compact. PATIENTS AND METHODS: Seven adults with bilateral conductive or mixed hearing losses who were users of a bone-anchored hearing aid were tested with the Baha Compact in quiet and in noise. Tests were repeated after 3 months of use with the Baha Divino. RESULTS: There was no significant difference between the two types of Baha for speech understanding in quiet when tested with German numbers and monosyllabic words at presentation levels between 50 and 80 dB. For speech understanding in noise, an advantage of 2.3 dB for the Baha Divino vs the Baha Compact was found, if noise was emitted from a loudspeaker to the rear of the listener and the directional microphone noise reduction system was activated. Subjectively, the Baha Divino was rated statistically significantly better in terms of overall sound quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditional methods of measuring sound absorption coefficient and sound transmission loss of a material are time consuming. To overcome this limitation, normal incidence sound absorption and transmission loss measurement technique was developed. Unfortunately the equipment required for this task is equally expensive. Hence efforts are taken to develop a cost-effective equipment for measuring normal incidence sound absorption coefficient and transmission loss. An impedance tube capable of measure absorption coefficient and transmission loss is designed and built under a budget of $1500 for educational institutes. A background study is performed to gain knowledge and understanding of the normal incidence measurements technique. Based on the literature review, parameters involved such as tube material, source and microphone properties, sample holders, etc. are discussed in depth. Based on these parameters, design options are generated to meet the cost and functionality targets pre-assigned. After selection of materials and components, an impedance tube is built and tested using three fibrous absorption materials for absorption and a barrier for transmission loss performance. These measured results then compared with those obtained with the help of industry recognized Brüel & Kjær impedance tube. The results show performances are comparable, hence validation the new built tube.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone-anchored hearing implants (BAHI) are routinely used to alleviate the effects of the acoustic head shadow in single-sided sensorineural deafness (SSD). In this study, the influence of the directional microphone setting and the maximum power output of the BAHI sound processor on speech understanding in noise in a laboratory setting were investigated. Eight adult BAHI users with SSD participated in this pilot study. Speech understanding in noise was measured using a new Slovak speech-in-noise test in two different spatial settings, either with noise coming from the front and noise from the side of the BAHI (S90N0) or vice versa (S0N90). In both spatial settings, speech understanding was measured without a BAHI, with a Baha BP100 in omnidirectional mode, with a BP100 in directional mode, with a BP110 power in omnidirectional and with a BP110 power in directional mode. In spatial setting S90N0, speech understanding in noise with either sound processor and in either directional mode was improved by 2.2-2.8 dB (p = 0.004-0.016). In spatial setting S0N90, speech understanding in noise was reduced by either BAHI, but was significantly better by 1.0-1.8 dB, if the directional microphone system was activated (p = 0.046), when compared to the omnidirectional setting. With the limited number of subjects in this study, no statistically significant differences were found between the two sound processors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Na(+)/Ca(2+) exchangers (NCX) constitute a major Ca(2+) export system that facilitates the re-establishment of cytosolic Ca(2+) levels in many tissues. Ca(2+) interactions at its Ca(2+) binding domains (CBD1 and CBD2) are essential for the allosteric regulation of Na(+)/Ca(2+) exchange activity. The structure of the Ca(2+)-bound form of CBD1, the primary Ca(2+) sensor from canine NCX1, but not the Ca(2+)-free form, has been reported, although the molecular mechanism of Ca(2+) regulation remains unclear. Here, we report crystal structures for three distinct Ca(2+) binding states of CBD1 from CALX, a Na(+)/Ca(2+) exchanger found in Drosophila sensory neurons. The fully Ca(2+)-bound CALX-CBD1 structure shows that four Ca(2+) atoms bind at identical Ca(2+) binding sites as those found in NCX1 and that the partial Ca(2+) occupancy and apoform structures exhibit progressive conformational transitions, indicating incremental regulation of CALX exchange by successive Ca(2+) binding at CBD1. The structures also predict that the primary Ca(2+) pair plays the main role in triggering functional conformational changes. Confirming this prediction, mutagenesis of Glu(455), which coordinates the primary Ca(2+) pair, produces dramatic reductions of the regulatory Ca(2+) affinity for exchange current, whereas mutagenesis of Glu(520), which coordinates the secondary Ca(2+) pair, has much smaller effects. Furthermore, our structures indicate that Ca(2+) binding only enhances the stability of the Ca(2+) binding site of CBD1 near the hinge region while the overall structure of CBD1 remains largely unaffected, implying that the Ca(2+) regulatory function of CBD1, and possibly that for the entire NCX family, is mediated through domain interactions between CBD1 and the adjacent CBD2 at this hinge.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The number of older adults in the global population is increasing. This demographic shift leads to an increasing prevalence of age-associated disorders, such as Alzheimer's disease and other types of dementia. With the progression of the disease, the risk for institutional care increases, which contrasts with the desire of most patients to stay in their home environment. Despite doctors' and caregivers' awareness of the patient's cognitive status, they are often uncertain about its consequences on activities of daily living (ADL). To provide effective care, they need to know how patients cope with ADL, in particular, the estimation of risks associated with the cognitive decline. The occurrence, performance, and duration of different ADL are important indicators of functional ability. The patient's ability to cope with these activities is traditionally assessed with questionnaires, which has disadvantages (eg, lack of reliability and sensitivity). Several groups have proposed sensor-based systems to recognize and quantify these activities in the patient's home. Combined with Web technology, these systems can inform caregivers about their patients in real-time (e.g., via smartphone). OBJECTIVE We hypothesize that a non-intrusive system, which does not use body-mounted sensors, video-based imaging, and microphone recordings would be better suited for use in dementia patients. Since it does not require patient's attention and compliance, such a system might be well accepted by patients. We present a passive, Web-based, non-intrusive, assistive technology system that recognizes and classifies ADL. METHODS The components of this novel assistive technology system were wireless sensors distributed in every room of the participant's home and a central computer unit (CCU). The environmental data were acquired for 20 days (per participant) and then stored and processed on the CCU. In consultation with medical experts, eight ADL were classified. RESULTS In this study, 10 healthy participants (6 women, 4 men; mean age 48.8 years; SD 20.0 years; age range 28-79 years) were included. For explorative purposes, one female Alzheimer patient (Montreal Cognitive Assessment score=23, Timed Up and Go=19.8 seconds, Trail Making Test A=84.3 seconds, Trail Making Test B=146 seconds) was measured in parallel with the healthy subjects. In total, 1317 ADL were performed by the participants, 1211 ADL were classified correctly, and 106 ADL were missed. This led to an overall sensitivity of 91.27% and a specificity of 92.52%. Each subject performed an average of 134.8 ADL (SD 75). CONCLUSIONS The non-intrusive wireless sensor system can acquire environmental data essential for the classification of activities of daily living. By analyzing retrieved data, it is possible to distinguish and assign data patterns to subjects' specific activities and to identify eight different activities in daily living. The Web-based technology allows the system to improve care and provides valuable information about the patient in real-time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES To establish whether complex signal processing is beneficial for users of bone anchored hearing aids. METHODS Review and analysis of two studies from our own group, each comparing a speech processor with basic digital signal processing (either Baha Divino or Baha Intenso) and a processor with complex digital signal processing (either Baha BP100 or Baha BP110 power). The main differences between basic and complex signal processing are the number of audiologist accessible frequency channels and the availability and complexity of the directional multi-microphone noise reduction and loudness compression systems. RESULTS Both studies show a small, statistically non-significant improvement of speech understanding in quiet with the complex digital signal processing. The average improvement for speech in noise is +0.9 dB, if speech and noise are emitted both from the front of the listener. If noise is emitted from the rear and speech from the front of the listener, the advantage of the devices with complex digital signal processing as opposed to those with basic signal processing increases, on average, to +3.2 dB (range +2.3 … +5.1 dB, p ≤ 0.0032). DISCUSSION Complex digital signal processing does indeed improve speech understanding, especially in noise coming from the rear. This finding has been supported by another study, which has been published recently by a different research group. CONCLUSIONS When compared to basic digital signal processing, complex digital signal processing can increase speech understanding of users of bone anchored hearing aids. The benefit is most significant for speech understanding in noise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION The Rondo is a single-unit cochlear implant (CI) audio processor comprising the identical components as its behind-the-ear predecessor, the Opus 2. An interchange of the Opus 2 with the Rondo leads to a shift of the microphone position toward the back of the head. This study aimed to investigate the influence of the Rondo wearing position on speech intelligibility in noise. METHODS Speech intelligibility in noise was measured in 4 spatial configurations with 12 experienced CI users using the German adaptive Oldenburg sentence test. A physical model and a numerical model were used to enable a comparison of the observations. RESULTS No statistically significant differences of the speech intelligibility were found in the situations in which the signal came from the front and the noise came from the frontal, ipsilateral, or contralateral side. The signal-to-noise ratio (SNR) was significantly better with the Opus 2 in the case with the noise presented from the back (4.4 dB, p < 0.001). The differences in the SNR were significantly worse with the Rondo processors placed further behind the ear than closer to the ear. CONCLUSION The study indicates that CI users with the receiver/stimulator implanted in positions further behind the ear are expected to have higher difficulties in noisy situations when wearing the single-unit audio processor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the speech intelligibility in noise with a new cochlear implant (CI) processor that uses a pinna effect imitating directional microphone system. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Ten experienced, unilateral CI recipients with bilateral severe-to-profound hearing loss. INTERVENTION All participants performed speech in noise tests with the Opus 2 processor (omnidirectional microphone mode only) and the newer Sonnet processor (omnidirectional and directional microphone mode). MAIN OUTCOME MEASURE The speech reception threshold (SRT) in noise was measured in four spatial settings. The test sentences were always presented from the front. The noise was arriving either from the front (S0N0), the ipsilateral side of the CI (S0NIL), the contralateral side of the CI (S0NCL), or the back (S0N180). RESULTS The directional mode improved the SRTs by 3.6 dB (p < 0.01), 2.2 dB (p < 0.01), and 1.3 dB (p < 0.05) in the S0N180, S0NIL, and S0NCL situations, when compared with the Sonnet in the omnidirectional mode. There was no statistically significant difference in the S0N0 situation. No differences between the Opus 2 and the Sonnet in the omnidirectional mode were observed. CONCLUSION Speech intelligibility with the Sonnet system was statistically different to speech recognition with the Opus 2 system suggesting that CI users might profit from the pinna effect imitating directionality mode in noisy environments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Early and accurate detection of TB disease in HIV-infected individuals is a critical step for a successful TB program. In Vietnam, the diagnosis of TB disease, which is based predominantly on the clinical examination, chest radiography (CXR) and acid fast bacilli (AFB) sputum smear, has shown to be of low sensitivity in immunocompromised patients. The sputum culture is not routinely performed for patients with AFB negative smears, even in HIV-infected individuals.^ In that background, we conducted this cross-sectional study to estimate the prevalence of sputum culture-confirmed pulmonary tuberculosis (PTB), smear-negative PTB, and multidrug-resistant TB (MDR-TB) in the HIV-infected population in Ho Chi Minh City (HCMC), the largest city in Vietnam where both TB and HIV are highly prevalent. We also evaluated the diagnostic performance of various algorithms based on routine available tools in Vietnam such as symptoms screening, CXR, and AFB smear. Nearly 400 subjects were consecutively recruited from HIV-infected patients seeking care at the An Hoa Clinic in District 6 of Ho Chi Minh City from August 2009 through June 2010. Participants’ demographic data, clinical status, CXR, and laboratory results were collected. A multiple logistic regression model was developed to assess the association of covariates and PTB. ^ The prevalence of smear-positive TB, smear-negative TB, resistant TB, and MDR-TB were 7%, 2%, 5%, 2.5%, and 0.3%, respectively. Adjusted odds ratios for low CD4+ cell count, positive sputum smear, and CXR to positive sputum culture were 3.17, 32.04, and 4.28, respectively. Clinical findings alone had poor sensitivity, but the combination of CD4+ cell count, sputum smear, and CXR proved to perform a more accurate diagnosis.^ This study results support the routine use of sputum culture to improve the detection of TB disease in HIV-infected individuals in Vietnam. When routine sputum culture is not available, an algorithm combining CD4+ cell count, sputum smear, and CXR is recommended for diagnosing PTB. Future studies on more affordable, rapid, and accurate tests for TB infection would also be necessary to timely provide specific treatments for patients in need, reduce mortality, and minimize TB transmission to the general population.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two new features have been proposed and used in the Rich Transcription Evaluation 2009 by the Universidad Politécnica de Madrid, which outperform the results of the baseline system. One of the features is the intensity channel contribution, a feature related to the location of the speaker. The second feature is the logarithm of the interpolated fundamental frequency. It is the first time that both features are applied to the clustering stage of multiple distant microphone meetings diarization. It is shown that the inclusion of both features improves the baseline results by 15.36% and 16.71% relative to the development set and the RT 09 set, respectively. If we consider speaker errors only, the relative improvement is 23% and 32.83% on the development set and the RT09 set, respectively.