970 resultados para Gingival prosthesis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated factors that may influence the presence or absence of interproximal papillae. Clinical evaluation consisted of visual determination, and quantitative analyses were made using millimeter grids on radiographs. Patients (n = 45) were divided into three groups according to age. Data were analyzed using the chi-square test followed by the Student t test (alpha = .05). The distance from the contact point to the bone crest had significant influence on papilla presence in both anterior and posterior sites (P < .05), whereas the width between roots of adjacent teeth did not. The papilla was missing more frequently in anterior sites. The presence of papillae was not age-dependent. (Int J Periodontics Restorative Dent 2012;32:e68-e74.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This in vitro study compared the dimensional accuracy of a stone index and of two impression techniques (squared impression copings and modified squared impression copings) for implant-supported prostheses. Materials and Methods: A master cast with four parallel implant-abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Three groups of impressions were tested (n = 5): index (1), squared (S), and modified squared (MS). The measurement method employed was just one titanium screw tightened to the framework. The measurements (60 gap values) were analyzed using software that received the images from a video camera coupled to a stereomicroscope at x 100 magnification. The results were evaluated statistically (analysis of variance, Holm-Sidak method, alpha = .05). Results: The mean abutment/framework interface gaps were: master cast = 31.63 mu m; group I = 45.25 mu m; group S = 96.14 mu m; group MS = 51.20 mu m. No significant difference was detected among the index and modified squared techniques (P = .05). Conclusion: Under the limitations of this study, the techniques modified squared and index generated more accurate casts than the squared technique. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:715-721

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate, in vitro, the dimensional accuracy of two impression techniques (squared impression copings and squared impression copings sandblasted and coated with impression adhesive) made of vinyl polysiloxane and polyether impression materials. Materials and Methods: A master cast (control group) with four parallel implant abutment analogs, a passive framework, and a custom aluminum tray was fabricated. Four groups (n = 5 each group) were tested: squared Impregum (SI), squared Express (SE), sandblasted adhesive squared Impregum (ASI), and sandblasted adhesive squared Express (ASE). The measurement method employed was just one titanium screw tightened to the framework. A stereomicroscope was used to evaluate the fit of the framework by measuring the size of the gap between the abutment and the framework. The results were analyzed statistically. Results: The mean values for the abutment/framework interface gaps were: master cast, 31.63 mu m (SD 2.16); SI, 38.03 mu m (SD 9.29); ASI, 46.80 mu m (SD 8.47); SE, 151.21 mu m (SD 22.79); and ASE, 136.59 mu m (SD 29.80). No significant difference was detected between the SI or ASI techniques and the master cast. No significant difference was detected between the SE and ASE techniques. Conclusion: Within the limitations of this study, it can be concluded that Impregum Soft medium consistency was the best impression material and the impression technique did not influence the accuracy of the stone casts. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:771-776

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). Results: The mean gap value with the index technique was 27.07 mu m. With the conventional pouring technique, the mean gap values were 116.97 mu m for the tapered group, 5784 mu m for the squared group, and 73.17 mu m for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 mu m for the tapered group, 38.03 mu m for the squared group, and 82.47 mu m for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 jum for the tapered group, 74.19 mu m for the squared group, and 104.67 mu m for the squared splinted group. No significant difference was detected among Index, squarellatex techniques, and master cast (P > .05). Conclusions: The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To examine the histomorphologic and histomorphometric features of tissue from 3 unrelated families with hereditary gingival fibromatosis (HGF).Study design. Twelve affected individuals from 3 HGF families and 3 control subjects were evaluated. Gingival samples were fixed in formalin and embedded in paraffin for hematoxylin and eosin stain to count the number of fibroblast and inflammatory cells. Sirius red staining was performed to quantitate the amount of collagen present.Results. Histomorphologic analysis of HGF showed extension of epithelial rete ridges into the underlying lamina propria and the presence of collagen bundles in the connective tissue. Analysis of the mean area fraction of collagen showed that there were significant increases in the collagen fraction for all HGF types compared with control subjects (P < .05). There were significant increases in the number of fibroblasts for HGFa and HGFb compared with control subjects (P < .05). The number of fibroblasts for HGFc were similar to that for control subjects.Conclusions. The collagen fraction was significantly greater in all HGF types compared with controls. The number of fibroblasts was significantly increased in 2 of the 3 HGF types compared with controls. These data indicate that different mechanisms may be responsible for tissue enlargement in different forms of HGF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the effect of a mouth-rinse prepared using Lippia sidoides essential oil (EO) in dogs with marginal gingivitis. German Shepherd dogs were distributed in two groups: control (control mouth-rinse) and EO (EO mouth-rinse). Both mouth-rinses were applied on the dogs' teeth every 2 days for 2 weeks. At day 0 and day 15, the scores for plaque-bacteria (P), calculus (C), gingivitis (G) and the inflammatory infiltrate (INF) were evaluated blindly. The results were analyzed by the Wilcoxon signed-rank and Mann-Whitney tests (P less than or equal to 0.05). P, C, G, and INF did not show any alteration in the control group, while in the EO group there were significant reductions in these scores. (C) 2003 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

THE INFLUENCE OF CHEMICAL PLAQUE CONTROL, using topically applied 0.12% chlorhexidine, on the severity of cyclosporin A (CsA)-induced gingival overgrowth (GO) was evaluated. Forty Holtzman rats were divided into four groups: 1) control; 2) cyclosporin A: a 10mg/kg/day subcutaneous dose of CsA; 3) chlorhexidine: 0.12% chlorhexidine (CHX) was applied to the buccal surface of the right mandibular molars; and 4) cyclosporin A/chlorhexidine: a combination of the treatment described for cyclosporin A and chlorhexidine groups. The animals were fed a high sucrose diet during the experiment and were sacrificed after 14 and 21 days. The histometric analysis revealed a significant increase in buccal gingival area in the cyclosporin A group compared to other groups (P < 0.01) after 21 days. The epithelium thickness of the buccal gingiva was significantly increased in the cyclosporin A group, compared to the control group (P < 0.05). The cyclosporin A/chlorhexidine group exhibited statistically significantly lower gingival overgrowth than the cyclosporin A group. These findings, if replicated in human studies, suggest that topically applied 0.12% chlorhexidine may be a valuable measure in the management of cyclosporin-induced gingival overgrowth.