225 resultados para FSS reconfiguráveis
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Biotecnologia - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Reabilitação Oral - FOAR
Resumo:
Pós-graduação em Biotecnologia - IQ
Resumo:
Purpose: This study was designed to evaluate the correlation between computed tomography findings and data from the physical examination and the Friedman Staging System (FSS) in patients with obstructive sleep apnea (OSA). Patients and Methods: We performed a retrospective evaluation by reviewing the medical records of 33 patients (19 male and 14 female patients) with a mean body mass index of 30.38 kg/m 2 and mean age of 49.35 years. Among these patients, 14 presented with severe OSA, 7 had moderate OSA, 7 had mild OSA, and 5 were healthy. Results: The patients were divided into 2 groups according to the FSS: Group A comprised patients with FSS stage I or II, and group B comprised patients with FSS stage III. By use of the Fisher exact test, a positive relationship between the FSS stage and apnea-hypopnea index ( P = .011) and between the FSS stage and body mass index ( P = .012) was found. There was no correlation between age ( P = .55) and gender ( P = .53) with the FSS stage. The analysis of variance test comparing the upper airway volume between the 2 groups showed P =.018. Conclusions: In this sample the FSS and upper airway volume showed an inverse correlation and were useful in analyzing the mechanisms of airway collapse in patients with OSA.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The goal of the present study was to investigate possible differences towards strenght recovery measured by different methods and running economy (RE), after one session of downhill running (DR), in order to induce muscle damage (MD). Our hypothesis is that the strenght recovery measured by jumps is more alike RE markers, due to the measures' specificity. Ten male subjects, ages 18 to 30, apparently healthy, without any experience with strenght training at least 6 months before the tests took place in this study. After going to the lab twice (to familiarize themselves with the protocols, and determine their maximum oxygen consumption/running speeds), they went to the lab five times in the following week, in order to collect all the variables before, immediately after, and 24, 48, 72 and 96 hours in. The variables obtained were: stride frequency (SF), stride lenght (SL), oxygen volume (VO2), carbon dioxide volume (VCO2), ventilation (VE), lactate blood concentration ([Lac]), isometric peak torque (IPT), subjective pain perception (SPP), effort perception (EP), medial-portion circumference (CIR), knee movement extent (EXT), torque development rate (TDR), counter movement jump and squat jump height (HCM and HS), strenght development rate of both jumps (SDCM and SDS), and maximum soil strenght reaction (SRCM and SRS). Changes over time in all variables were verified by one way variancy analysis. Differences between the strenght measures were verified by two way variancy analysis. When significant effects were verified, Tuckey's post-hoc were applied. The significancy level taken on this study was p < 0,05. Of all indirect muscle damage markers, IPT, SPP and TDR were the only ones in which ocurred significant changes. We couldn't find the moments where this happened for TDR with the post-hoc used. On RE markers, VO2, [Lac] and VE suffered significant effects over time. About the jumps variables, only SDCM and HCM presented significant...
Resumo:
The development of safe, high energy and power electrochemical energy-conversion systems can be a response to the worldwide demand for a clean and low-fuel-consuming transport. This thesis work, starting from a basic studies on the ionic liquid (IL) electrolytes and carbon electrodes and concluding with tests on large-size IL-based supercapacitor prototypes demonstrated that the IL-based asymmetric configuration (AEDLCs) is a powerful strategy to develop safe, high-energy supercapacitors that might compete with lithium-ion batteries in power assist-hybrid electric vehicles (HEVs). The increase of specific energy in EDLCs was achieved following three routes: i) the use of hydrophobic ionic liquids (ILs) as electrolytes; ii) the design and preparation of carbon electrode materials of tailored morphology and surface chemistry to feature high capacitance response in IL and iii) the asymmetric double-layer carbon supercapacitor configuration (AEDLC) which consists of assembling the supercapacitor with different carbon loadings at the two electrodes in order to exploit the wide electrochemical stability window (ESW) of IL and to reach high maximum cell voltage (Vmax). Among the various ILs investigated the N-methoxyethyl-N-methylpyrrolidinium bis(trifluoromethanesulfonyl)imide (PYR1(2O1)TFSI) was selected because of its hydrophobicity and high thermal stability up to 350 °C together with good conductivity and wide ESW, exploitable in a wide temperature range, below 0°C. For such exceptional properties PYR1(2O1)TFSI was used for the whole study to develop large size IL-based carbon supercapacitor prototype. This work also highlights that the use of ILs determines different chemical-physical properties at the interface electrode/electrolyte with respect to that formed by conventional electrolytes. Indeed, the absence of solvent in ILs makes the properties of the interface not mediated by the solvent and, thus, the dielectric constant and double-layer thickness strictly depend on the chemistry of the IL ions. The study of carbon electrode materials evidences several factors that have to be taken into account for designing performing carbon electrodes in IL. The heat-treatment in inert atmosphere of the activated carbon AC which gave ACT carbon featuring ca. 100 F/g in IL demonstrated the importance of surface chemistry in the capacitive response of the carbons in hydrophobic ILs. The tailored mesoporosity of the xerogel carbons is a key parameter to achieve high capacitance response. The CO2-treated xerogel carbon X3a featured a high specific capacitance of 120 F/g in PYR14TFSI, however, exhibiting high pore volume, an excess of IL is required to fill the pores with respect to that necessary for the charge-discharge process. Further advances were achieved with electrodes based on the disordered template carbon DTC7 with pore size distribution centred at 2.7 nm which featured a notably high specific capacitance of 140 F/g in PYR14TFSI and a moderate pore volume, V>1.5 nm of 0.70 cm3/g. This thesis work demonstrated that by means of the asymmetric configuration (AEDLC) it was possible to reach high cell voltage up to 3.9 V. Indeed, IL-based AEDLCs with the X3a or ACT carbon electrodes exhibited specific energy and power of ca. 30 Wh/kg and 10 kW/kg, respectively. The DTC7 carbon electrodes, featuring a capacitance response higher of 20%-40% than those of X3a and ACT, respectively, enabled the development of a PYR14TFSI-based AEDLC with specific energy and power of 47 Wh/kg and 13 kW/kg at 60°C with Vmax of 3.9 V. Given the availability of the ACT carbon (obtained from a commercial material), the PYR1(2O1)TFSI-based AEDLCs assembled with ACT carbon electrodes were selected within the EU ILHYPOS project for the development of large-size prototypes. This study demonstrated that PYR1(2O1)TFSI-based AEDLC can operate between -30°C and +60°C and its cycling stability was proved at 60°C up to 27,000 cycles with high Vmax up to 3.8 V. Such AEDLC was further investigated following USABC and DOE FreedomCAR reference protocols for HEV to evaluate its dynamic pulse-power and energy features. It was demonstrated that with Vmax of 3.7 V at T> 30 °C the challenging energy and power targets stated by DOE for power-assist HEVs, and at T> 0 °C the standards for the 12V-TSS and 42V-FSS and TPA 2s-pulse applications are satisfied, if the ratio wmodule/wSC = 2 is accomplished, which, however, is a very demanding condition. Finally, suggestions for further advances in IL-based AEDLC performance were found. Particularly, given that the main contribution to the ESR is the electrode charging resistance, which in turn is affected by the ionic resistance in the pores that is also modulated by pore length, the pore geometry is a key parameter in carbon design not only because it defines the carbon surface but also because it can differentially “amplify” the effect of IL conductivity on the electrode charging-discharging process and, thus, supercapacitor time constant.
Resumo:
Psychological flow describes the mental phenomenon that takes place during intense engagement with a task (Jackson & Csikszentmihalyi, 1999). Its components have been operationalized through the development of the Flow State Scale (Jackson & Eklund, 2002). As feedback has been shown to be a critical element for the facilitation of a flow experience (Moneta, 2012), the current study sought to investigate the effect of differential feedback on psychological flow outcomes using the FSS as the dependent variable. The feedback manipulation featured three experimental groups; control, positive, and negative. This study also accounted for the personality trait of perfectionism as a variable influencing the experience of flow. Following the completion of a personality measure, participants engaged in a bolt threading task for ten minutes, then reported the time they perceived to have spent on the task as well as the outcome of their flow experience. The feedback conditions were created by the use of different size containers for participants to place their nut and bolt pairs in, and thus feedback was inherent in the task. The study found that feedback played an important role in the outcome of a flow experience. The positive feedback condition was more conducive to flow than the negative feedback condition. Furthermore, those in the positive condition outperformed those in the negative condition during the ten minutes. Goal clarity and feedback clarity differed significantly across feedback manipulations. Perfectionism¿s impact on the outcome of flow was more pronounced in the negative feedback condition than the positive or control conditions. In settings where engagement and performance are imperative, ample attention should be given to the feedback processes present in the situation.