988 resultados para Excel Tips
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The establishment of laboratory colonies of ticks is often hampered by their lack of adaptation to alternative hosts. The aim of this study was to artificially feed partially engorged Dermacentor (Anocentor) nitens females through plastic tips, and to identify what are the optimal conditions of application of this technique to get as much as possible close to the natural conditions. The technique of artificial feeding through plastic tips allowed the engorgement of D. nitens ticks to a final weight within the normal range for the species. (C) 2014 Published by Elsevier GmbH.
Resumo:
When a bolted joint is loaded in tension with dynamically, part of this load is absorbed by the bolt and rest is absorbed by the joint material. What determines the portion that is to absorbed by the bolt is the joint stiffness factor. This factor influences the tension which corresponds to pre-load and the safety factor for fatigue failure, thus being an important factor in the design of bolted joints. In this work, three methods of calculating the stiffness factor are compared through a spreadsheet in Excel software. The ratio of initial pre-load and the safety factor for fatigue failure depending on the stiffness factor graph is generated. The calculations for each method show results with a small difference. It is therefore recommended that each project case is analyzed, and depending on its conditions and the range of stiffness values, the more or less rigid method about the safety factor for fatigue failure is chosen. In general, the approximation method provides consistent results and can be easily calculated
Resumo:
This work aims to determine the first natural frequency of rotation shaft by using a basic software, Excel, and to compare it to the values obtained in laboratory. When an axle is submitted to a rotation, depending on the rotational frequency used, the axle can enter a state of resonance, in which the amplitude of vibration becomes rather high. The frequencies in which the resonance is observed depends on several parameters of the axle, including the number of concentrated masses associated to the axle. Thus, to obtain a computer program of easy use and access, which can preview the frequency of resonance of an axle in rotation with ‘n’ numbers of concentrated masses it has been studied how the frequency varies with each of these parameters. The computer program and the analyses have been made using the Rayleigh Method, which allowed the transformation of a continuous system to discrete through the theory of finite elements, which has proved that, the bigger the number of divisions of the shaft taken into consideration in the calculus of the natural frequency, the more this value gets close to the real value. The results obtained have been considered satisfactory once these have gotten close to the theoretical results expected
Análise estrutural de treliças espaciais no software Excel utilizando o médodo dos elementos finitos
Resumo:
The following paper means to develop a program to make structural analysis of space trusses. The program to be implemented was based on the concepts of the finite element method and used the programing resources of Visual Basic for Applications (VBA) for the Excel Software®. Being Excel® a software of easy access, low cost, capacity to make matrix calculations and with advanced resources of VBA programing, it is possible to develop an economic solution, efficient and precise for structural analysis of space trusses. Firstly is presented a finite elemento method and the space truss. Then is developed a few important algorithms to be used during the development of the program and also the use of a few resources of VBA. And to validate the quality, efficiency and precision of the results, these are compared with the established commercial software Ansys
Resumo:
The non-eruption of teeth due to highly keratinized gingival mucosa is a frequent event in the pediatric dentistry, which harms the oral aesthetics and function. A surgical excision of the involved area is indicated, exposing the non-erupted tooth. This procedure involves anesthesia and cutting instruments that may increase the fear and anxiety in young patients. The use of new technologies has avoided these instruments and has promoted more comfort to the patients. This study presents clinical cases in which gingivectomy was performed using the innovative method with an ultrasound-activated CVD tip. It was concluded that this method presented effectiveness, promoted more comfort, and less fear to the patients, making its use a viable alternative to pediatric surgery.
Resumo:
Guava (Psidium guajava L.) is a plant often employed in popular medicine. Recently several studies have alerted about the toxicity of substances present in medicinal plants, which can pose risks to the human health. In this sense, the present work aimed to investigate the phytotoxic, cytotoxic and genotoxic action of three guava varieties - Paluma, Pedro Sato and Roxa (purple) - on the plant test system Lactuca sativa L. Thus, macro- and microscopic evaluations were carried out for five infusion concentrations (2.5, 5.0, 10.0, 20.0 and 40.0 g.L-1) prepared from each variety. Distilled water was used as negative control. Chromatographic and spectroscopic analysis by HPLC-PAD indicated that the chemical composition of the infusion of Roxa is different than that of the infusions of the varieties Paluma and Pedro Sato. It was observed that seed germination and root growth in L. sativa exposed to infusions decreased with increasing infusion concentration, regardless of the tested cultivar. For the mitotic index, no statistical differences were observed. On the other hand, a significant increase in the frequency of cell cycle alterations was verified, especially for the highest concentrations tested. The cytogenotoxic was significant. Therefore, guava should not be used indiscriminately in popular medicine.
Resumo:
Objective: The use of Er:YAG laser operating in the 3 μm range with adjustable power and pulses has become popular for dental and medical practice due to its high photoablative capacity, surgical precision and antimicrobial action. Background data: The existing fiberoptic tips irradiate lasers parallel to the long axes of the tooth limiting its efficiency in the root canal. Methods: We evaluated hollow fiberoptic tips obtained from silicate glass as a means of Er:YAG laser conduction in dental procedures. The fiber tips were molded from capillary tubes with different profiles so that their ends would have cylindric, conical or spherical shapes. The performance of the three fibers as a means of propagation of Er:YAG (λ = 2.94 μm) laser radiation was compared to that of a solid sapphire fiber at 10 Hz and 200 mJ and of 20 Hz and 500 mJ. The profiles of frontal and lateral burning were visualized on thermal paper. Results: Analysis of these profiles demonstrated that the sapphire tip and the hollow fiber of cylindric section did not differ significantly in the profiles of frontal burning, and no lateral burning was detected. The fibers of the conical and spherical sections, although presenting attenuation in the frontal output power, showed a larger burning area in the frontal profile, in addition to producing lateral burning. Conclusions: The results indicate that commercial hollow fiberoptics have advantages such as easy manufacture of the different tip shapes, great adaptability, low cost, and a low loss of transmission. © Mary Ann Liebert, Inc.
Resumo:
This review intended to describe in a didactic and practical manner the frontotemporosphenoidal craniotomy, which is usually known as pterional craniotomy and constitute the cranial approach mostly utilized in the modern neurosurgery. This is, then, basically a descriptive text, divided according to the main stages involved in this procedure, and describes with details how the authors currently perform this craniotomy.
Resumo:
The aim of this study was to evaluate the compressive strength of microhybrid (FiltekTM Z250) and nanofilled (FiltekTM Supreme XT) composite resins photo-activated with two different light guide tips, fiber optic and polymer, coupled with one LED. The power density was 653 mW cm-2 when using the fiber optic light tip and 596 mW cm-2 with the polymer. After storage in distilled water at 37± 2 °C for seven days, the samples were subjected to mechanical testing of compressive strength in an EMIC universal mechanical testing machine with a load cell of 5 kN and speed of 0.5 mm min-1. The statistical analysis was performed using ANOVA with a confidence interval of 95% and Tamhane’s test. The results showed that the mean values of compressive strength were not influenced by the different light tips (p > 0.05). However, a statistical difference was observed (p < 0.001) between the microhybrid composite resin photo-activated with the fiber optic light tip and the nanofilled composite resin. Based on these results, it can be concluded that microhybrid composite resin photo-activated with the fiber optic light tip showed better results than nanofilled, regardless of the tip used, and the type of the light tip did not influence the compressive strength of either composite. Thus, the presented results suggest that both the fiber optic and polymer light guide tips provide adequate compressive strength to be used to make restorations. However, the fiber optic light tip associated with microhybrid composite resin may be an interesting option for restorations mainly in posterior teeth.
Resumo:
Objective: The aim of this study was to evaluate the degree of conversion and hardness of different composite resins, photo-activated for 40 s with two different light guide tips, fiber optic and polymer. Methods: Five specimens were made for each group evaluated. The percentage of unreacted carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). The Vickers hardness measurements were performed in a universal testing machine. A 50 gf load was used and the indenter with a dwell time of 30 seconds. The degree of conversion and hardness mean values were analyzed separately by ANOVA and Tukey's test, with a significance level set at 5%. Results: The mean values of degree of conversion for the polymer and fiber optic light guide tip were statistically different (P<.001). The hardness mean values were statistically different among the light guide tips (P<.001), but also there was difference between top and bottom surfaces (P<.001). Conclusions: The results showed that the resins photo-activated with the fiber optic light guide tip promoted higher values for degree of conversion and hardness.
Resumo:
Introduction: Transjugular intrahepatic porto-systemic shunt (TIPS) is an accepted indication for treating refractory ascites. Different models have been proposed for the prediction of survival after TIPS; aim of present study was to evaluate the factors associated with mortality after TIPS for refractory ascites. Methods: Seventy-three consecutive patients undergoing a TIPS for refractory ascites in our centre between 2003 and 2008, were prospectively recorded in a database ad were the subject of the study. Mean follow-up was 17±2 months. Forty patients were awaiting liver transplantation (LT) and 12 (16.4%) underwent LT during follow-up. Results: Mean MELD at the moment of TIPS was 15.7±5.3. Overall mortality was 23.3% (n=17) with a mean survival after TIPS of 17±14 months. MELD score (B=0.161, p=0.042), AST (B= 0.020, p=0.090) and pre-TIPS HVPG (B=0.016, p=0.093) were independent predictors of overall mortality. On multivariate analysis MELD (B=0.419, p=0.018) and pre-TIPS HVPG (B=0.223, p=0.060) independently predicted 1 year survival. Patients were stratified into categories of death risk, using ROC curves for the variables MELD and HVPG. Patients with MELD<10 had a low probability of death after TIPS (n=6, 16% mortality); patients with HVPG <16 mmHg (n=6) had no mortality. Maximum risk of death was found in patients with MELD score 19 (n=16, 31% mortality) and in those with HVPG 25 mmHg (n=27, 26% mortality). Conclusions: TIPS increases overall survival in patients with refractory ascites. Liver function (assessed by MELD), necroinflammation (AST) and portal hypertension (HVPG) are independent predictors of survival; patients with MELD>19 and HVPG>25 mmHg are at highest risk of death after TIPS
Resumo:
Il presente lavoro di tesi si inserisce all’interno del progetto europeo i-FLEXIS il cui obiettivo è lo sviluppo di un sensore di raggi X innovativo, affidabile, a basso costo e basato su componenti eterogenei organici. Attualmente, i rivelatori di radiazione ionizzante a stato solido fanno uso di materiali inorganici e sono ampiamente impiegati in ambito medico, industriale e come dispositivi per la sicurezza. Le scoperte scientifiche degli ultimi anni nell'ambito dei semiconduttori organici hanno evidenziato che tali materiali sono sensibili alla radiazione ionizzante e il loro utilizzo permette di realizzare rivelatori diretti di raggi-X, convertendo fotoni in segnale elettrico. Questi dispositivi sono caratterizzati da flessibilità, possibilità di lavorare a temperatura ambiente, basso costo di produzione, poca energia di alimentazione, alta sostenibilità ambientale e dalla possibilità di coprire grandi aree. Tutte queste proprietà concorrono ad incrementare sempre più l’attenzione e l’interesse dei ricercatori in questo relativamente nuovo mondo: i semiconduttori organici. In questa tesi sono stati esaminati cinque diversi campioni di TIPS-pentacene con la finalità di evidenziare quali si prestino meglio come rivelatori di raggi-X. I campioni sono tutti in diverse forme e spaziano dal cristallo singolo ai film sottili, con particolare attenzione al comportamento dei cristalli singoli cresciuti mediante processi di stampa direttamente sul substrato. Per quanto riguarda i semiconduttori organici, la frazione di raggi-X assorbita dai materiali è molto piccola e non è in grado di giustificare il segnale misurato. Si è effettuato inoltre un confronto tra la risposta dei campioni alla luce visibile e alla radiazione ionizzante per comprendere il meccanismo di generazione e rivelazione delle cariche in seguito all’assorbimento di raggi-X.