816 resultados para Estruturas de Betão Armado


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The corrosive phenomenon on reinforced concrete structures is one of the most founded pathologies on the coastal area. With the objective to prevent the process development, or even, retard its beginning, it was studied the application of inorganic covering over concrete surfaces, after its cure, as well as, evaluate the efficiency of the covering applied on the concrete in reducing its porosity of concrete preventing the entrance of aggressive agents to preserve the integrity of the existing armor inside it, comparing the result obtained with the body-of-proof reference, that didn´t receive covering protection. On the concrete production it was used Portland Cement CP II 32, coarse aggregate, fine aggregate and water from the local distributive. Two types of covering were used, one resin based of silicon and solvent and other white cement based, selected sands and acrylic resin. The concrete mixture adopted was 1:1,5:2,5 (cement, fine aggregate, coarse aggregate) and 0.50 water/cement ratio. With the concrete on fresh state was made the experiment test to determinate the workability. On the hardened state was made the concrete resistance experiment, absorption of water and electrochemical experiments, through polarization curves. Also was held optical microscopy and Scanning Electron Microscopy experiments to analyze the layer of the covering applied to the concrete surface and the interface between the concrete and the layer. The obtained results shows that the covering applied to the concrete surface didn´t affect the resistance towards compression. On the absorption of water occurred a diminution of the percentage absorbed, improving the concrete development by making it more impermeable towards the entrance of aggressive agents. The electrochemical experiment results confirmed the water absorption results; the body-of-proof covered presented larger protection towards the development of corrosives process and retarded the evolution of the corrosive phenomenon

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Due to the occurrence of diseases in the use of structural reinforcements in composites, with presentation of concrete blanket detachment, has been identified the need to evaluate the performance of concrete reinforced with glass fiber. This study aims to evaluate these concretes by means of testing methodologies, using concrete with low resistance with structural reinforcement for confinement by preimpregnated glass fiber and traditional fiberglass blanket. The first stage of work was the development of methodologies for analysis, opting for four types, such as the acoustic survey, strength to compressive, the pull-off and ultrasound. Next, tests were carried out using the four selected methodologies in 30 of proof-of-specimens by 5x10 cm, 15 were reinforced with the traditional fiberglass blanket with 5specimens exposed to test a marine environment of marine coastline of Natal-RN and 15 were reinforced with a pre-impregnated glass fiber blanket, as well as 5specimens exposed to a test environment of the marine coastline of Natal-RN. After conducting the acoustic survey, it has been verified a lack of delaminating and air bubbles in the samples, confirming the absence of gross shortcomings in the implementation of the ribs both the traditional fiberglass blanket and in the preimpregnated fiber glass blanket. After carrying out methods of pull-off and compressive strengthening test it was observed that the reinforced proof-bodies with pre-impregnated glass blanket showed maximum stresses higher than the traditional fiberglass blanket; consequently a greater grip with the formation of a smaller area of . fracture, unlike traditional glass mat, which showed lower maximum stresses, with a greater area of fracture. It was also found that the traditional fiberglass blanket presented detachment of blanket-concrete interface, unlike the pre-impregnated fiberglass blanket, which showed a better grip on the blanket-concrete interface. In the trial of ultrasound there was no presence of cracks in the blanket-concrete interface, yielding to both blankets good compactness of the concrete. At the end of this work, they were developed and proposed two methods of testing for evaluation of reinforced concrete structures with composites, for standardization, the acoustic survey and pull-off

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The reinforced concrete structures are largely used in buildings worldwide. Upon the occurrence of fire in buildings, there is a consensus among researchers that the concrete has a high resistance to fire, due mainly to its low thermal conductivity. However, this does not mean that this material is not affected by exposure to high temperatures. Reduction of the compressive strength, modulus of elasticity, discoloration and cracking, are some of the effects caused by thermal exposure. In the case of concretes with higher resistance occurs even desplacamentos explosives, exposing the reinforcement to fire and contributing to reducing the support capacity of the structural element. Considering the above, this study aims to examine how the compressive strength and porosity of concrete are affected when subjected to high temperatures. Were evaluated concrete of different resistances, and even was the verified if addition fibers of polyethylene terephthalate (PET) in concrete can be used as an alternative to preventing spalling. The results indicated that explosive spalling affect not only high strength concrete whose values of this study ranged from 70 to 88 MPa, as well as conventional concrete of medium strength (52 MPa) and the temperature range to which the concrete begins to suffer significant changes in their resistance is between 400 º C and 600 º C, showing to 600 º C a porosity up to 188% greater than the room temperature

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The search for alternative materials with lower density, reduction in heat transfer and propagation of noise associated with the ease of handling and application in concrete structures, represents an enormous challenge in the formulation and knowledge of the performance of self-compacting lightweight concrete, which has technology little known nationally, and appears on the international scene as an innovative material and alternative to conventional concrete. Based on these, this study set out to study self-compacting lightweight concrete made with two distinct grades of expanded clay associated with the addition of plasticizing/superplasticizers additives and mineral additions of metakaolin and bagasse ash of sugar cane. There is also an object of study, evaluation of pozzolanic activity of mineral admixtures and their influence on the durability characteristics of concrete. The rheological, physical, mechanical and microstructural analysis in this study served as basis in the classification of concretes autoadensáveis, targeting the national technical requirements for their classification in the category autoadensável and lightweight structural. The inclusion of mineral admixtures (metakaolin and bagasse ash of sugar cane), partial replacement of cement, pozzolanic activity and demonstrated maintenance of mechanical properties through the filler effect, a reduction of up to 76% of the nitrogen gas permeability in blend with 20% bagasse ash. All concretes had rheology (cohesion and consistency) suitable for self-adensability as well as strength and density inherent structural lightweight concrete without presenting phenomena of segregation and exudation

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The bond between steel and concrete is essential for the existence of reinforced concrete structures, as both materials act together to absorb structural strain. The bond phenomenon is considered to be complex regarding many factors that affect it. Several types of bond tests have been proposed over years. One is the modified proposed of pull-out test, which was elaborated by Lorrain and Barbosa [1] called APULOT test (Appropriete pull-out-test). Based on experimental results obtained by Vale Silva[2] either by conventional pull-out tests, or by modified pull-out test, APULOT, seeks to know the numeric behavior of bond steel-concrete through a numerical simulation using a calculation code ATENA which is based on the Finite Element Method (FEM). The numerical simulation provided better evaluate the stress distribution and cracking that occurs during the test, thereby becoming a valuable tool to support the experimental project that aims to validation, validation partially or not recommend the modified bond test steel-concrete - APULOT test - as quality control test of structural concrete. The numerical results showed good representation compared to experimental results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Since the Seventies, there has been a growing degradation of concrete structures in Brazil. For that reason, much research has been made on the durability of those structures, aiming at contributing towards quality improvement and reduction of maintenance and repair costs. This study evaluates the behavior of the durability of high-performance concrete with additions, replacing part of the cement and aggregates with rice husk ash and tire rubber, respectively. Durability tests were carried out in which concrete was subjected to several degradation processes, such as the action of water, temperature, salts and acid solution. The results indicated that the addition of active silica or rice husk ash, both with tire rubber did not worsen the durability of concrete. In fact, rubber proved to be very effective in preventing the action of chemical agents, high temperatures and the penetration of water. Rice husk ash, despite the larger diameter of particles, had similar results to that of the active silica.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work talks about the importance of the steel adhesion to concrete, reinforced concrete structures, their testing and forms of measurement used and how the results are used in the structural design, which uses as a reference the NBR 6118 and NBR 7480. It also deals with the importance of a reliable assessment, discussing failures that the test used, NBR 7477, features in specific circumstances, as discussed under the EC-094. It also presents an initial proposal for simplified pullout test, which aims to analyze the grip on steel bars with diameter less than 10 mm, which results when used standardized testing by ABNT NBT 7477, has shown excessive variability, the main criticism of the trial today used without distinction to be established thick or thin bars. The proposal also presented methodology is in the consolidation phase, given the time and the volume of necessary tests. For this reason it is not possible to make a comparison between the values obtained and the results of the test used on the basis of the standard in force, this can only be done once the front with a continuation of this work

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work talks about the importance of the steel adhesion to concrete, reinforced concrete structures, their testing and forms of measurement used and how the results are used in the structural design, which uses as a reference the NBR 6118 and NBR 7480. It also deals with the importance of a reliable assessment, discussing failures that the test used, NBR 7477, features in specific circumstances, as discussed under the EC-094. It also presents an initial proposal for simplified pullout test, which aims to analyze the grip on steel bars with diameter less than 10 mm, which results when used standardized testing by ABNT NBT 7477, has shown excessive variability, the main criticism of the trial today used without distinction to be established thick or thin bars. The proposal also presented methodology is in the consolidation phase, given the time and the volume of necessary tests. For this reason it is not possible to make a comparison between the values obtained and the results of the test used on the basis of the standard in force, this can only be done once the front with a continuation of this work

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper addresses the analysis of probabilistic corrosion time initiation in reinforced concrete structures exposed to ions chloride penetration. Structural durability is an important criterion which must be evaluated in every type of structure, especially when these structures are constructed in aggressive atmospheres. Considering reinforced concrete members, chloride diffusion process is widely used to evaluate the durability. Therefore, at modelling this phenomenon, corrosion of reinforcements can be better estimated and prevented. These processes begin when a threshold level of chlorides concentration is reached at the steel bars of reinforcements. Despite the robustness of several models proposed in the literature, deterministic approaches fail to predict accurately the corrosion time initiation due to the inherently randomness observed in this process. In this regard, the durability can be more realistically represented using probabilistic approaches. A probabilistic analysis of ions chloride penetration is presented in this paper. The ions chloride penetration is simulated using the Fick's second law of diffusion. This law represents the chloride diffusion process, considering time dependent effects. The probability of failure is calculated using Monte Carlo simulation and the First Order Reliability Method (FORM) with a direct coupling approach. Some examples are considered in order to study these phenomena and a simplified method is proposed to determine optimal values for concrete cover.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O Exército Português tem à sua guarda um importante património construído, muitas vezes localizado no centro histórico de núcleos urbanos, o qual, ao longo dos anos teve várias ocupações, tendo por isso sofrido intervenções várias, mais ou menos intrusivas. Devido ao interesse manifestado pela instituição em reabilitar edifícios localizados no centro de Lisboa com vista a novas utilizações, nomeadamente para a instalação do Pólo Cultural do Exército, foi realizado um estudo no âmbito da presente dissertação de mestrado sobre um edifício integrante do Prédio Militar nº 50 (PM050/Lisboa), cuja origem remonta ao século XVIII. Face à proposta de utilização do objeto de estudo como arquivo histórico, neste trabalho é feita a caracterização da construção existente e a análise da sua adequação estrutural para acomodar este tipo de utilização. Inicialmente foi feita uma inspeção ao edifício para identificação das anomalias e problemas estruturais visíveis, em seguida foram consultados todos os documentos e projetos que pudessem conter informação sobre o mesmo. Face à falta de informação sobre os materiais utilizados nos elementos estruturais, foram realizados ensaios não-destrutivos para a caracterização das suas propriedades mecânicas, assim como uma pesquisa e análise dos regulamentos em vigor à data da sua construção. Posteriormente, foi construído um modelo numérico com recurso ao programa SAP2000 (Structural Analysis Program 2000) para avaliar a capacidade resistente da estrutura. Por fim foram elaboradas algumas propostas de intervenção. Concluiu-se haver necessidade de reforço nas alvenarias, as quais apresentam um mau comportamento às ações sísmicas. Relativamente aos elementos de betão armado, a baixa resistência dos materiais utilizados, o sistema estrutural adoptado e a degradação em alguns locais implicam igualmente a sua necessidade de reforço. A proposta de intervenção apresentada tem por objetivo servir de base à elaboração de um projeto de reforço, caso se avance com a reabilitação do edifício, sendo necessário realizar um estudo mais aprofundado.