929 resultados para Energy Performance of Buildings
Resumo:
Power converters play a vital role in the integration of wind power into the electrical grid. Variable-speed wind turbine generator systems have a considerable interest of application for grid connection at constant frequency. In this paper, comprehensive simulation studies are carried out with three power converter topologies: matrix, two-level and multilevel. A fractional-order control strategy is studied for the variable-speed operation of wind turbine generator systems. The studies are in order to compare power converter topologies and control strategies. The studies reveal that the multilevel converter and the proposed fractional-order control strategy enable an improvement in the power quality, in comparison with the other power converters using a classical integer-order control strategy. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
When timber elements in heritage buildings are moderately degraded by fungi and assuming underlying moisture problems have been solved, two actions can be taken: i) use a biocide to stop fungal activity; ii) consolidate the degraded elements so that the timber keeps on fulfilling its structural and decorative functions. The aim of this work is to investigate the mechanical performance of maritime pine wood degraded by fungi after being treated with a biocide followed by impregnation with a polymer product. Three commercially available products were used: a boron water-based biocide, an acrylic consolidant and an epoxy-based consolidant. Treated and consolidated specimens were subjected to mechanical tests: axial compression test (NP 618), static surface hardness (ISO 3350) and bending test (NP 619). Sets of replicates were subjected to an evaporation ageing test (EN 73) after application of the products and also tested for mechanical behaviour. An increase in mechanical strength was observed for both consolidants with no significant influence from the previous use of biocide product. The specimens subjected to ageing showed a slightly better general mechanical performance.
Resumo:
This paper studies periodic gaits of quadruped locomotion systems. The purpose is to determine the best set of gait and locomotion variables during walking, for different robot velocities, based on two formulated performance measures. A set of experiments reveals the influence of the gait and locomotion variables upon the proposed indices, namely that the gait and the locomotion parameters should be adapted to the robot forward velocity.
Resumo:
In this study, an attempt was made in order to measure and evaluate the eco-efficiency performance of a pultruded composite processing company. For this purpose the recommendations of World Business Council for Sustainable Development (WCSD) and the directives of ISO 14301 standard were followed and applied. The main general indicators of eco-efficiency, as well as the specific indicators, were defined and determined. With basis on indicators’ figures, the value profile, the environmental profile, and the pertinent eco-efficiency ratios were established and analyzed. In order to evaluate potential improvements on company eco-performance, new indicators values and eco-efficiency ratios were estimated taking into account the implementation of new proceedings and procedures, at both upstream and downstream of the production process, namely: i) Adoption of a new heating system for pultrusion die-tool in the manufacturing process, more effective and with minor heat losses; ii) Recycling approach, with partial waste reuse of scrap material derived from manufacturing, cutting and assembly processes of GFRP profiles. These features lead to significant improvements on the sequent assessed eco-efficiency ratios of the present case study, yielding to a more sustainable product and manufacturing process of pultruded GFRP profiles.
Resumo:
4th International Conference on Climbing and Walking Robots - From Biology to Industrial Applications
Resumo:
Stone masonry is one of the oldest and most worldwide used building techniques. Nevertheless, the structural response of masonry structures is complex and the effective knowledge about their mechanical behaviour is still limited. This fact is particularly notorious when dealing with the description of their out-of-plane behaviour under horizontal loadings, as is the case of the earthquake action. In this context, this paper describes an experimental program, conducted in laboratory environment, aiming at characterizing the out-of-plane behaviour of traditional unreinforced stone masonry walls. In the scope of this campaign, six full-scale sacco stone masonry specimens were fully characterised regarding their most important mechanic, geometric and dynamic features and were tested resorting to two different loading techniques under three distinct vertical pre-compression states; three of the specimens were subjected to an out-of-plane surface load by means of a system of airbags and the remaining were subjected to an out-of-plane horizontal line-load at the top. From the experiments it was possible to observe that both test setups were able to globally mobilize the out-of-plane response of the walls, which presented substantial displacement capacity, with ratios of ultimate displacement to the wall thickness ranging between 26 and 45 %, as well as good energy dissipation capacity. Finally, very interesting results were also obtained from a simple analytical model used herein to compute a set of experimental-based ratios, namely between the maximum stability displacement and the wall thickness for which a mean value of about 60 % was found.
Resumo:
Given the need for using more sustainable constructive solutions, an innovative composite material based on a combination of distinct industrial by-products is proposed aiming to reduce waste and energy consumption in the production of construction materials. The raw materials are thermal activated flue-gas desulphurization (FGD) gypsum, which acts as a binder, granulated cork as the aggregate and recycled textile fibres from used tyres intended to reinforce the material. This paper presents the results of the design of the composite mortar mixes, the characterization of the key physical properties (density, porosity and ultrasonic pulse velocity) and the mechanical validation based on uniaxial compressive tests and fracture energy tests. In the experimental campaign, the influence of the percentage of the raw materials in terms of gypsum mass, on the mechanical properties of the composite material was assessed. It was observed that the percentage of granulated cork decreases the compressive strength of the composite material but contributes to the increase in the compressive fracture energy. Besides, the recycled textile fibres play an important role in the mode I fracture process and in the fracture energy of the composite material, resulting in a considerable increase in the mode I fracture energy.
Resumo:
Construction sector is one of the major responsible for energy consumption and carbon emissions and renovation of existing buildings plays an important role in the actions to mitigate climate changes. Present work is based on the methodology developed in IEA Annex 56, allowing identifying cost optimal and cost effective renovation scenarios improving the energy performance. The analysed case study is a residential neighbourhood of the municipality of Gaia in Portugal. The analysis compares a reference renovation scenario (without improving the energy performance of the building) with a series of alternative renovation scenarios, including the one that is being implemented.
Resumo:
The relevance of the building sector in the global energy use as well as in the global carbon emissions, both in the developed and developing countries, makes the improvement of the overall energy performance of existing buildings an important part of the actions to mitigate climate changes. Regardless of this potential for energy and emissions saving, large scale building renovation has been found hard to trigger, mainly because present standards are mainly focused on new buildings, not responding effectively to the numerous technical, functional and economic constraints of the existing ones. One of the common problems in the assessment of building renovation scenarios is that only energy savings and costs are normally considered, despite the fact that it has been long recognized that investment on energy efficiency and low carbon technologies yield several benefits beyond the value of saved energy which can be as important as the energy cost savings process. Based on the analysis of significant literature and several case studies, the relevance of co-benefits achieved in the renovation process is highlighted. These benefits can be felt at the building level by the owner or user (like increased user comfort, fewer problems with building physics, improved aesthetics) and should therefore be considered in the definition of the renovation measures, but also at the level of the society as a whole (like health effects, job creation, energy security, impact on climate change), and from this perspective, policy makers must be aware of the possible crossed impacts among different areas of the society for the development of public policies.
Resumo:
The performance of the ATLAS muon trigger system has been evaluated with proton--proton collision data collected in 2012 at the Large Hadron Collider at a centre-of-mass energy of 8 TeV. The performance was primarily evaluated using events containing a pair of muons from the decay of Z bosons. The efficiency is measured for the single-muon trigger for a kinematic region of the transverse momentum pT between 25 and 100 GeV, with a statistical uncertainty of less than 0.01% and a systematic uncertainty of 0.6%. The performance is also compared in detail to the predictions from simulation. The efficiency was measured over a wide pT range (a few GeV to several hundred GeV) by using muons from J/ψ mesons,W bosons, and top and antitop quarks. It showed highly uniform and stable performance.
Resumo:
This paper describes the trigger and offline reconstruction, identification and energy calibration algorithms for hadronic decays of tau leptons employed for the data collected from pp collisions in 2012 with the ATLAS detector at the LHC center-of-mass energy s√ = 8 TeV. The performance of these algorithms is measured in most cases with Z decays to tau leptons using the full 2012 dataset, corresponding to an integrated luminosity of 20.3 fb−1. An uncertainty on the offline reconstructed tau energy scale of 2% to 4%, depending on transverse energy and pseudorapidity, is achieved using two independent methods. The offline tau identification efficiency is measured with a precision of 2.5% for hadronically decaying tau leptons with one associated track, and of 4% for the case of three associated tracks, inclusive in pseudorapidity and for a visible transverse energy greater than 20 GeV. For hadronic tau lepton decays selected by offline algorithms, the tau trigger identification efficiency is measured with a precision of 2% to 8%, depending on the transverse energy. The performance of the tau algorithms, both offline and at the trigger level, is found to be stable with respect to the number of concurrent proton--proton interactions and has supported a variety of physics results using hadronically decaying tau leptons at ATLAS.
Resumo:
This paper reports on a new façade system that uses passive solutions in the search for energy efficiency. The differentials are the versatility and flexibility of the modules, which are important advantages of the system. The thermal performance of Trombe walls and glazings and the daylighting performance of glazing were the key aspects analyzed in the results. Computational simulations were accomplished for the thermal performance of different arrangements of the modules with DesignBuilder software. The glazing daylighting performance was studied by means of Ecotect and Desktop Radiance programs and compared with the transmittance curves of glazings. Occupancy profile and internal gains were fixed according to the Portuguese reality for both studies. The main characteristics considered in this research were the use of two double glazings, four different climates in Portugal and one and two Trombe walls in the façade. The results show an important reduction in the energy consumption with the use of Trombe walls and double self-cleaning glazing in the façade, which also presented better daylighting performance.
Resumo:
PURPOSE: Multi-hour ski mountaineering energy balance may be negative and intake below recommendations. METHODS: Athletes on the 'Patrouille des Glaciers' racecourses (17 on course Z, 27 km, +2,113 m; 11 on course A, 26 km, +1,881 m) volunteered. Pre-race measurements included body mass, stature, VO2max, and heart rate (HR) vs VO2 at simulated altitude; race measurements HR, altitude, incline, location, and food and drink intake (A). Energy expenditure (EE) was calculated from altitude corrected HR derived VO2. RESULTS: Race time was 5 h 7 min ± 44 min (mean ± SD, Z) and 5 h 51 min ± 53 min (A). Subjects spent 19.2 ± 3.2 MJ (Z), respectively, 22.6 ± 2.9 MJ (A) during the race. Energy deficit was -15.5 ± 3.9 MJ (A); intake covered 20 ± 7 % (A). Overall energy cost of locomotion (EC) was 9.9 ± 1.3 J m(-1) kg(-1) (Z), 8.0 ± 1.0 J m(-1) kg(-1) (A). Uphill EC was 11.7 ± 1 J m(-1) kg(-1) (Z, 13 % slope) and 15.7 ± 2.3 J m(-1) kg(-1) (A, 19 % slope). Race A subjects lost -1.5 ± 1.1 kg, indicating near euhydration. Age, body mass, gear mass, VO2max and EC were significantly correlated with performance; energy deficit was not. CONCLUSIONS: Energy expenditure and energy deficit of a multi-hour ski mountaineering race are very high and energy intake is below recommendations.
Resumo:
The performance of different correlation functionals has been tested for alkali metals, Li to Cs, interacting with cluster models simulating different active sites of the Si(111) surface. In all cases, the ab initio Hartree-Fock density has been obtained and used as a starting point. The electronic correlation energy is then introduced as an a posteriori correction to the Hartree-Fock energy using different correlation functionals. By making use of the ionic nature of the interaction and of different dissociation limits we have been able to prove that all functionals tested introduce the right correlation energy, although to a different extent. Hence, correlation functionals appear as an effective and easy way to introduce electronic correlation in the ab initio Hartree-Fock description of the chemisorption bond in complex systems where conventional configuration interaction techniques cannot be used. However, the calculated energies may differ by some tens of eV. Therefore, these methods can be employed to get a qualitative idea of how important correlation effects are, but they have some limitations if accurate binding energies are to be obtained.
Resumo:
The objective of this work was to evaluate corn gluten meal (CGM) as a substitute for fish meal in diets for striped catfish (Pseudoplatystoma fasciatum) juveniles. Eight isonitrogenous (46% crude protein) and isoenergetic (3,450 kcal kg-1 digestible energy) diets, with increasing levels of CGM - 0, 6, 12, 18, 24, 30, 36, and 42% -, were fed to juvenile striped catfish (113.56±5.10 g) for seven weeks. Maximum values for weight gain, specific growth rate, protein efficiency ratio and feed conversion ratio, evaluated by polynomial quadratic regression, were observed with 10.4, 11.4, 15.4 and 15% of CGM inclusion, respectively. Feed intake decreased significantly from 0.8% CGM. Mesenteric fat index and body gross energy decreased linearly with increasing levels of CGM; minimum body protein contents were observed with 34.1% CGM. Yellow pigmentation of fillets significantly increased until 26.5% CGM, and decreased from this point forth. Both plasma glucose and protein concentrations decreased with increased CGM levels. The inclusion of 10-15% CGM promotes optimum of striped catfish juveniles depending on the parameter evaluated. Yellow coloration in fillets produced by CGM diets can have marketing implications.