951 resultados para Electronic equipment testing
Resumo:
This thesis has developed a new approach to trace virtual protection signals in Electrical substation networks. The main goal of the research was to analyse the contents of the virtual signals transferred, using third party software. In doing so, a comprehensive test was done on a distance protection relay, using non-conventional test equipment.
Resumo:
Traction is recognised as an important component of the overall playability and safety of a sportsfield. It relates to the "grip", or footing, provided through an athlete's shoe when in contact with the surface, and is normally measured by the torque generated when a weighted studded disc apparatus is dropped onto the turf and twisted manually. This paper describes the development of an automated traction tester, which mechanises the dropping and twisting of the weighted studded disc. By standardising these operational stages, more repeatable and reliable results can be expected than from the original hand-operated design where positioning of the disc and speed of rotation are controlled manually and so can vary from one measurement to the next. As well as measuring the maximum torque reached during rotation of the studded disc, the automated traction tester generates a profile of torque showing changes over time and calculates the angle through which the studded disc moved before reaching maximum torque. These aspects are now covered by a utility patent (PAT/AU/2004270767). Use of the automated traction tester is illustrated by comparative data for a range of warm-season turfgrasses, by comparisons of traction under different surface conditions generated by wear on Cynodon dactylon cultivars, and by the effects of environment, management and playing patterns on traction across a multi-use sports stadium.
Resumo:
This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.
Resumo:
High temperature ceramic membranes have interesting possibilities for application in areas of new and developing technologies such as hydrocarbon combustion with carbon dioxide capture and electrochemical promotion of catalysis (EPOC). However, membrane module sealing remains a significant technical challenge. In this work a borosilicate glass sealant (50SiO2·25B2O3·25Na2O, mol%) was developed to fit the requirements of sealing an air separation membrane system at intermediate temperatures (300-600 °C). The seal was assessed by testing the leak rates under a range of conditions. The parameters tested included the effect of flowrate on the leak rate, the heating and cooling rates of the reactor and the range of temperatures under which the system could operate. Tests for durability and reliability were also performed. It was found that the most favourable reactor configuration employed a reactor with the ceramic pellet placed underneath the inner chamber alumina tube (inverted configuration), using a quartz wool support to keep the membrane in place prior to sealing. Using this configuration the new glass-based seal was found to be a more suitable sealant than traditional alternatives; it produced lower leak rates at all desirable flowrates, with the potential for rapid heating and cooling and multiple cycling, allowing for prolonged usage. © 2010 Elsevier B.V. All rights reserved.
Resumo:
Damages -reduced in fruit packing lines is a major cause of grace reduction and quality loos in fresh marks: fruit. Fruit must be treated gently during in sir handling to improve their qualityin order to get a good price in a competitive market. The correct post-hardvest handling in fruit packing lines is a prerequisite to cut down the heavy post-harvest losses. Fruit packing lines must be evaluated, studying their design, the impacts applied to the fruits, the characteristics of the materials, etc. This study establishes the possibility of carrying out modifications and tests in a packing line during a long period of time. For this purpose, an experimental fruit packing line has been designed and located in the Agricultural Engineering Department of the Polythecnic University of Madrid with the aim of improving mechanical devices and fruit handling conditions to minimize damage to fruit. The experimental line consists of several transporting belts, one rollers transporter, one sizer, one elevator, one singularizer, and three trays to receive the calibrated fruit. The line has a length of 6.15 m and a width cf 1.9 m. Movement of the different components is regulated by electric motors with variable velocity electronically controlled. The height of the transfer points is variable and can be easily modified. The experimental line has been calibrated using two instrumented spheres IS 100 (8.8 cm Ø and6.2cm Ø). Average acceleration values obtained in all the transfers of the experimental line lay under 80 g's, although there is big variation for some of them being some values above 100 g's.
Resumo:
Actual system performance of a PV system can differ from its expected behaviour.. This is the main reason why the performance of PV systems should be monitored, analyzed and, if needed, improved on. Some of the current testing procedures relating to the electrical behaviour of PV systems are appropriated for detecting electrical performance losses, but they are not well-suited to reveal hidden defects in the modules of PV plants and BIPV, which can lead to future losses. This paper reports on the tests and procedures used to evaluate the performance of PV systems, and especially on a novel procedure for quick on-site measurements and defect recognition caused by overheating in PV modules located in operating PV installations.
Resumo:
Includes bibliographical references.
Resumo:
Mode of access: Internet.
Resumo:
A revision of a similar publication, AMS-16.