869 resultados para Electronic dissertations
Resumo:
In this work we produce and study the flexible organic–inorganic hybrid moisture barrier layers for the protection of air sensitive organic opto-electronic devices. The inorganic amorphous silicon nitride layer (SiNx:H) and the organic PMMA [poly (methyl methacrylate)] layer are deposited alternatingly by using hot wire chemical vapor deposition (HW-CVD) and spin-coating techniques, respectively. The effect of organic–inorganic hybrid interfaces is analyzed for increasing number of interfaces. We produce highly transparent (∼80% in the visible region) hybrid structures. The morphological properties are analysed providing a good basis for understanding the variation of the water vapor transmission rate (WVTR) values. A minimum WVTR of 4.5 × 10−5g/m2day is reported at the ambient atmospheric conditions for 7 organic/inorganic interfaces. The hybrid barriers show superb mechanical flexibility which confirms their high potential for flexible applications.
Resumo:
tThis work is devoted to the investigation of zirconium oxynitride (ZrOxNy) films with varied opticalresponses prompted by the variations in their compositional and structural properties. The films wereprepared by dc reactive magnetron sputtering of Zr, using Ar and a reactive gas mixture of N2+ O2(17:3).The colour of the films changed from metallic-like, very bright yellow-pale and golden yellow, for low gasflows to red-brownish for intermediate gas flows. Associated to this colour change there was a significantdecrease of brightness. With further increase of the reactive gas flow, the colour of the samples changedfrom red-brownish to dark blue or even to interference colourations. The variations in composition dis-closed the existence of four different zones, which were found to be closely related with the variationsin the crystalline structure. XRD analysis revealed the change from a B1 NaCl face-centred cubic zirco-nium nitride-type phase for films prepared with low reactive gas flows, towards a poorly crystallizedover-stoichiometric nitride phase, which may be similar to that of Zr3N4with some probable oxygeninclusions within nitrogen positions, for films prepared with intermediate reactive gas flows. For highreactive gas flows, the films developed an oxynitride-type phase, similar to that of -Zr2ON2with someoxygen atoms occupying some of the nitrogen positions, evolving to a ZrO2monoclinic type structurewithin the zone where films were prepared with relatively high reactive gas flows. The analysis carriedout by reflected electron energy loss spectroscopy (REELS) revealed a continuous depopulation of thed-band and an opening of an energy gap between the valence band (2p) and the Fermi level close to 5 eV.The ZrN-based coatings (zone I and II) presented intrinsic colourations, with a decrease in brightness anda colour change from bright yellow to golden yellow, red brownish and dark blue. Associated to thesechanges, there was also a shift of the reflectivity minimum to lower energies, with the increase of thenon-metallic content. The samples lying in the two last zones (zone III, oxynitride and zone IV, oxide films)revealed a typical semi-transparent-optical behaviour showing interference-like colourations only dueto the complete depopulation of the d band at the Fermi level. The samples lying in these zones presentedalso an increase of the optical bandgap from 2 to 3.6 eV.
Resumo:
Objective To systematically review the scientific literature on the psychometric properties of international instruments for the assessment of autism spectrum disorder (ASD) in the Brazilian population. Methods A search of bibliographic references was conducted in six electronic databases: PsycINFO, PubMed, IndexPsi, Lilacs, Capes (theses and dissertations) and SciELO. The studies were selected by two independent researchers. Results The procedure identified 11 studies of the Brazilian population that encompassed six ASD assessment tools. Given the information provided, the adaptation of the M-CHAT, a screening instrument, was the best conducted. All steps of the adaptation process were described and the changes made to the final version of the instrument were presented, which was not addressed in other studies. In terms of reliability, all of the instruments that assessed internal consistency showed adequate values. In addition, the ADI-R and the CARS adaptations also satisfactorily contemplated inter-rater reliability and test-retest indices, respectively. Finally, all studies aiming to validate instruments showed evidence of validity and sensitivity, and specificity values above 0.90 were observed in the ASQ, ADI-R and ABC. Conclusion Considering both the psychometric aspects and the copyright information, the screening instrument that currently appears to be best indicated for clinical and research use is the M-CHAT. It was also noticed that there are still no specific ASD diagnostic tools available for use in Brazil. This lack of diagnostic instruments consists in a critical situation for the improvement of clinical practice and the development of research in this area.
Resumo:
Natural mineral waters (still), effervescent natural mineral waters (sparkling) and aromatized waters with fruit-flavors (still or sparkling) are an emerging market. In this work, the capability of a potentiometric electronic tongue, comprised with lipid polymeric membranes, to quantitatively estimate routinely quality physicochemical parameters (pH and conductivity) as well as to qualitatively classify water samples according to the type of water was evaluated. The study showed that a linear discriminant model, based on 21 sensors selected by the simulated annealing algorithm, could correctly classify 100 % of the water samples (leave-one out cross-validation). This potential was further demonstrated by applying a repeated K-fold cross-validation (guaranteeing that at least 15 % of independent samples were only used for internal-validation) for which 96 % of correct classifications were attained. The satisfactory recognition performance of the E-tongue could be attributed to the pH, conductivity, sugars and organic acids contents of the studied waters, which turned out in significant differences of sweetness perception indexes and total acid flavor. Moreover, the E-tongue combined with multivariate linear regression models, based on sub-sets of sensors selected by the simulated annealing algorithm, could accurately estimate waters pH (25 sensors: R 2 equal to 0.99 and 0.97 for leave-one-out or repeated K-folds cross-validation) and conductivity (23 sensors: R 2 equal to 0.997 and 0.99 for leave-one-out or repeated K-folds cross-validation). So, the overall satisfactory results achieved, allow envisaging a potential future application of electronic tongue devices for bottled water analysis and classification.
Resumo:
This project was funded under the Applied Research Grants Scheme administered by Enterprise Ireland. The project was a partnership between Galway - Mayo Institute of Technology and an industrial company, Tyco/Mallinckrodt Galway. The project aimed to develop a semi - automatic, self - learning pattern recognition system capable of detecting defects on the printed circuits boards such as component vacancy, component misalignment, component orientation, component error, and component weld. The research was conducted in three directions: image acquisition, image filtering/recognition and software development. Image acquisition studied the process of forming and digitizing images and some fundamental aspects regarding the human visual perception. The importance of choosing the right camera and illumination system for a certain type of problem has been highlighted. Probably the most important step towards image recognition is image filtering, The filters are used to correct and enhance images in order to prepare them for recognition. Convolution, histogram equalisation, filters based on Boolean mathematics, noise reduction, edge detection, geometrical filters, cross-correlation filters and image compression are some examples of the filters that have been studied and successfully implemented in the software application. The software application developed during the research is customized in order to meet the requirements of the industrial partner. The application is able to analyze pictures, perform the filtering, build libraries, process images and generate log files. It incorporates most of the filters studied and together with the illumination system and the camera it provides a fully integrated framework able to analyze defects on printed circuit boards.
Resumo:
1805
Resumo:
1801
Resumo:
El Centre de Supercomputació de Catalunya (CESCA) i el Consorci de Biblioteques Universitàries de Catalunya (CBUC) des del 1999, com a fruït del llavors Pla Estratègic Catalunya en Xarxa, promouen activitats per posar continguts a la xarxa en accés obert. Això s’ha materialitzat, de moment, en la posada en marxa de tres dipòsits col·lectius d'e-informació: Tesis Doctorals en Xarxa (TDX), Dipòsit de la Recerca de Catalunya (RECERCAT) i Revistes Catalanes amb Accés Obert (RACO). Al febrer de 2001 va néixer el TDX (www.tesisenxarxa.net), que permet la consulta de més de 3400 tesis doctorals llegides a les universitats de Catalunya i d'altres comunitats autònomes. Al setembre de 2005 es va inaugurar RECERCAT (www.recercat.net), un dipòsit cooperatiu de documents digitals que inclou la literatura de recerca de les universitats i dels centres d’investigació de Catalunya, com ara articles encara no publicats (preprints), comunicacions a congressos, informes de recerca, working papers, projectes de final de carrera, memòries tècniques, etc. El tercer dipòsit, RACO (www.raco.cat), s'ha posat en marxa a març de 2006, fent possible la consulta, en accés obert, dels articles a text complet de revistes científiques, culturals i erudites catalanes. Per al desenvolupament de tots tres dipòsits s'ha usat programari lliure. Per al TDX es va adaptar l'Electronic Theses and Dissertations (ETD) de la Universitat de Virgina Tech. Per a RECERCAT, el DSpace, fet pel Massachusetts Institute of Technology (MIT) i Hewlett-Packard (HP). I per a RACO s'ha fet servir el Open Journal Systems (OJS) del Public Knowledge Project (PKP). La comunicació pretén explicar breument què són aquests tres dipòsits, els beneficis obtinguts pel fet que hagin estat desenvolupats sota programari lliure i que les tesis, els documents de recerca i les revistes que contenen siguin en accés obert. Programari lliure i accés obert, un binomi guanyador.
Resumo:
Es presenten els resultats d’una enquesta sobre l’ús de revistes electròniques realitzada al professorat de les universitats que formen el Consorci de Biblioteques Universitàries de Catalunya (CBUC). Els resultats mostren un elevat grau de coneixement de la col·lecció de revistes electròniques entre el personal docent i investigador i una creixent preferència pel format electrònic en detriment de l’imprès. L’alt grau de coneixement i d’ús dels títols electrònics, i la preferència per aquest suport, comporten una elevada valoració de la col·lecció de revistes electròniques. Al mateix temps, la major part dels usuaris preveu un increment de l’ús dels títols electrònics durant els propers anys. Els resultats també confirmen la importància de la disciplina i de l’edat com a factors explicatius de l’ús de les revistes electròniques.
Resumo:
OBJECTIVE: Incomplete compliance is one of several possible causes of uncontrolled hypertension. Yet, non-compliance remains largely unrecognized and is falsely interpreted as treatment resistance, because it is difficult to confirm or exclude objectively. The goal of this study was to evaluate the potential benefits of electronic monitoring of drug compliance in the management of patients with resistant hypertension. METHODS: Forty-one hypertensive patients resistant to a three-drug regimen (average blood pressure 156/ 106 +/- 23/11 mmHg, mean +/- SD) were studied prospectively. They were informed that for the next 2 months, their presently prescribed drugs would be provided in electronic monitors, without any change in treatment, so as to provide the treating physician with a measure of their compliance. Thereafter, patients were offered the possibility of prolonging the monitoring of compliance for another 2 month period, during which treatment was adapted if necessary. RESULTS: Monitoring of compliance alone was associated with a significant improvement of blood pressure at 2 months (145/97 +/- 20/15 mmHg, P < 0.01). During monitoring, blood pressure was normalized (systolic < 140 mmHg or diastolic < 90 mmHg) in one-third of the patients and insufficient compliance was unmasked in another 20%. When analysed according to tertiles of compliance, patients with the lowest compliance exhibited significantly higher achieved diastolic blood pressures (P = 0.04). In 30 patients, compliance was monitored up to 4 months and drug therapy was adapted whenever necessary. In these patients, a further significant decrease in blood pressure was obtained (from 150/100 +/- 18/15 to 143/94 +/- 22/11 mmHg, P = 0.04/0.02). CONCLUSIONS: These results suggest that objective monitoring of compliance using electronic devices may be a useful step in the management of patients with refractory hypertension, as it enables physicians to take rational decisions based on reliable and objective data of drug compliance and hence to improve blood pressure control.
Resumo:
S’ha dissenyat un Laboratori Virtual d’Equips Electrònics per múltiples aplicacions específiques com a reforç docent en l’àrea de l’electrònica VERiLAB (Virtual ElectRonic LABoratory) i, a més, s’han dissenyat un conjunt de 9 pràctiques guiades per treure el màxim rendiment al laboratori virtual. El laboratori Virtual és una potent eina de treball per aplicacions docents com a programari d’iniciació a la utilització d’equips electrònics bàsics que podem trobar a qualsevol laboratori d’electrònica. Aquesta eina permet augmentar el nombre d’hores de treball pràctic fora del laboratori. La primera versió d’aquest programari es va dissenyar a l’any 2004 a la Universitat de Barcelona amb el software LabVIEW_7, el qual permet obtenir un fitxer executable amb el qual els alumnes poden treballar fora del laboratori. D’aquesta forma els alumnes únicament necessiten un ordinador per a poder fer les pràctiques. La primera versió del laboratori disposava d’un generador de funcions, un oscil·loscopi i un analitzador d’espectres com a equips electrònics, i a més a més incorporava un mòdul de filtres i un motor DC per treballar amb els equips. La versió 2 del Laboratori Virtual es va desenvolupar amb aquest projecte MQD i es va introduir una font d’alimentació, un multímetre de sobre taula i un portàtil com a equips electrònics. Es van crear també diferents mòduls de sistemes electrònics: filtres analògics, configuracions bàsiques basades en l’amplificador operacional, l’amplificador operacional no ideal i un circuit de rectificació d’ona completa. Aquests mòduls han premés ampliar el camp d’aplicació del Laboratori Virtual a diferents assignatures de l’àrea de l’electrònica.
Resumo:
In the recent years most libraries have focused on mass digitization programs and keeping electronic born documents, showing and organizing them in a repository. While those repositories have evolved to a much more manageable systems focusing on the user expectations and introducing web 2.0 tools, digital preservation is still in the to-do list of most of them. There is quite a lot of studies focused on preservation and some complex models exist, unfortunately, very few practical systems are running and its quite difficult for a library to get involved in a solution already tested by others. The CBUC (Consortium of University Catalan Libraries) runs TDX, an ETD repository now keeping more than 10.000 full text thesis from any of the 12 university members. After 10 years running TDX a solid preservation system was needed to ensure every thesis would be kept as it was regardless what happens to the repository. The perfect solution was found in the MetaArchive cooperative, this is the effort of many insitutions to keep a copy of each other content through a newtwork using the LOCKSS software as a mechanism to keep track of any change. The presentation will shortly introduce what TDX and MetaArchive is but will, in a practical way, show how the LOCKSS network for presrervation works. Finally a summary of the benefits of the overall experience will be shown.