911 resultados para Electromagnetic transient analyses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the scattering of the quantized electromagnetic field from a linear, dispersive dielectric using the scattering formalism for quantum fields. The medium is modeled as a collection of harmonic oscillators with a number of distinct resonance frequencies. This model corresponds to the Sellmeir expansion, which is widely used to describe experimental data for real dispersive media. The integral equation for the interpolating field in terms of the in field is solved and the solution used to find the out field. The relation between the ill and out creation and annihilation operators is found that allows one to calculate the S matrix for this system. In this model, we find that there are absorption bands, but the input-output relations are completely unitary. No additional quantum-noise terms are required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A scheme is presented to incorporate a mixed potential integral equation (MPIE) using Michalski's formulation C with the method of moments (MoM) for analyzing the scattering of a plane wave from conducting planar objects buried in a dielectric half-space. The robust complex image method with a two-level approximation is used for the calculation of the Green's functions for the half-space. To further speed up the computation, an interpolation technique for filling the matrix is employed. While the induced current distributions on the object's surface are obtained in the frequency domain, the corresponding time domain responses are calculated via the inverse fast Fourier transform (FFT), The complex natural resonances of targets are then extracted from the late time response using the generalized pencil-of-function (GPOF) method. We investigate the pole trajectories as we vary the distance between strips and the depth and orientation of single, buried strips, The variation from the pole position of a single strip in a homogeneous dielectric medium was only a few percent for most of these parameter variations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Petrov-Galerkin methods are known to be versatile techniques for the solution of a wide variety of convection-dispersion transport problems, including those involving steep gradients. but have hitherto received little attention by chemical engineers. We illustrate the technique by means of the well-known problem of simultaneous diffusion and adsorption in a spherical sorbent pellet comprised of spherical, non-overlapping microparticles of uniform size and investigate the uptake dynamics. Solutions to adsorption problems exhibit steep gradients when macropore diffusion controls or micropore diffusion controls, and the application of classical numerical methods to such problems can present difficulties. In this paper, a semi-discrete Petrov-Galerkin finite element method for numerically solving adsorption problems with steep gradients in bidisperse solids is presented. The numerical solution was found to match the analytical solution when the adsorption isotherm is linear and the diffusivities are constant. Computed results for the Langmuir isotherm and non-constant diffusivity in microparticle are numerically evaluated for comparison with results of a fitted-mesh collocation method, which was proposed by Liu and Bhatia (Comput. Chem. Engng. 23 (1999) 933-943). The new method is simple, highly efficient, and well-suited to a variety of adsorption and desorption problems involving steep gradients. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report outlines the development of optimized particle inflow gun (PIG) parameters for producing transgenic sorghum (Sorghum bicolor (L.) Moench). Both transient and stable expression were examined when determining these parameters. The uidA reporter gene (GUS) encoding beta -glucuronidase was used in transient experiments and the green fluorescent protein (GFP) used to monitor stable expression. Initially, optimization was conducted using leaf segments, as the generation of sorghum callus in sufficiently large quantities is time-consuming. Following leaf optimization, experiments were conducted using callus, identifying a high similarity between the two tissue types (r(s) = 0.83). High levels of GUS expression were observed in both leaf and callus material when most distant from the DNA expulsion point, and using a pressure greater than 1800 kPa. A higher level of expression was also observed when the aperture of the helium inlet valve was constricted. Using the optimized conditions (pressure of 2200 kPa, distance to target tissue of 15 cm from the expulsion point, and the aperture of the helium inlet valve at one full turn), three promoters (Ubiquitin, Actin1 and CaMV 35S) were evaluated over a 72-h period using GUS as the reporter gene. A significantly higher number of GUS foci were counted with the Ubiquitin construct over this period, compared to the Actin1 and CaMV 35S constructs. Stable callus sectors (on 2 mg l(-1) bialaphos) with GFP expression were visualized for as long as 6 wk post-bombardment. Using this optimized protocol, several plants were regenerated after having been bombarded with the pAHC20 construct (containing the bar gene), with molecular evidence confirming integration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cost and risk associated with mineral exploration in Australia increases significantly as companies move into deeper regolith-covered terrain. The ability to map the bedrock and the depth of weathering within an area has the potential to decrease this risk and increase the effectiveness of exploration programs. This paper is the second in a trilogy concerning the Grant's Patch area of the Eastern Goldfields. The recent development of the VPmg potential field inversion program in conjunction with the acquisition of high-resolution gravity data over an area with extensive drilling provided an opportunity to evaluate three-dimensional gravity inversion as a bedrock and regolith mapping tool. An apparent density model of the study area was constructed, with the ground represented as adjoining 200 m by 200 m vertical rectangular prisms. During inversion VPmg incrementally adjusted the density of each prism until the free-air gravity response of the model replicated the observed data. For the Grant's Patch study area, this image of the apparent density values proved easier to interpret than the Bouguer gravity image. A regolith layer was introduced into the model and realistic fresh-rock densities assigned to each basement prism according to its interpreted lithology. With the basement and regolith densities fixed, the VPmg inversion algorithm adjusted the depth to fresh basement until the misfit between the calculated and observed gravity response was minimised. The resulting geometry of the bedrock/regolith contact largely replicated the base of weathering indicated by drilling with predicted depth of weathering values from gravity inversion typically within 15% of those logged during RAB and RC drilling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study to be presented is the first to use a new physiological device, the electromagnetic articulograph, to assess articulatory dysfunction in children with acquired brain injury. Two children with dysarthria subsequent to acquired brain injury participated in the study. One child, a female aged 12 years 9 months exhibited a mild-moderate ataxic dysarthria following traumatic head injury while the other, a male aged 13 years 10 months, demonstrated a moderate-severe flaccid-ataxic dysarthria also following traumatic head injury. The speed and accuracy of their tongue movements was assessed using the Carstens AG100 electromagnetic articulograph. Movement trajectories together with a range of quantitative kinematic parameters were estimated during performance of ten repetitions of the lingual consonants /t, s, k/ and consonant cluster /kl/ in the word initial position of single syllable words. A group of ten non-neurologically impaired children served as controls. Examination of the kinematic parameters, including movement trajectories, velocity, acceleration, deceleration, distance travelled and duration of movement, revealed differences in the speed and accuracy of the tongue movements in both children with acquired brain injury compared to those produced by the non-neurologically impaired controls. The results are discussed in relation to contemporary theories of the effects of acquired brain injury on neuromuscular function. The implications of the findings for the treatment of articulatory dysfunction in children with motor speech disorders associated with acquired brain injury are highlighted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been recognised that in order to study the displacement, timing and co-ordination of articulatory components (i.e., tongue. lips, jaw) in speech production it is desirable to obtain high-resolution movement data on multiple structures inside and outside the vocal tract. Until recently, with the exception of X-ray techniques such as cineradiography, the study 0. speech movements has been hindered by the inaccessibility of the oral cavity during speech. X-ray techniques are generally not used because of unacceptable radiation exposure. The aim of the present study was to demonstrate the use of a new physiological device, the electromagnetic articulograph, for assessing articulatory dysfunction subsequent to traumatic brain injury. The components of the device together with the measuring principle are described and data collected from a single case presented. A 19 year-old male who exhibited dysarthria subsequent to a traumatic brain injury was fitted wit 2 the electromagnetic articulograph (Carstens AG-100) and a kinematic analysis of his tongue movements during production of the lingual consonants it, s, k/ within single syllable words was performed. Examination of kinematic parameters including movemmt trajectories, velocity, and acceleration revealed differences in the speed and accuracy of his tongue movements compared to those produced by a non-neurologically impaired adult male. It was concluded that the articulograph is a useful device for diagnosing speed and accuracy disorders in tongue movements during speech and that the device has potential for incorporation into physiologically based rehabilitation programs as a real-time biofeedback instrument.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite evidence linking shrimp farming to several cases of environmental degradation, there remains a lack of ecologically meaningful information about the impacts of effluent on receiving waters. The aim of this study was to determine the biological impact of shrimp farm effluent, and to compare and distinguish its impacts from treated sewage effluent. Analyses included standard water quality/sediment parameters, as well as biological indicators including tissue nitrogen (N) content, stable isotope ratio of nitrogen (delta N-15) and amino acid composition of inhabitant seagrasses, mangroves and macroalgae. The study area consisted of two tidal creeks, one receiving effluent from a sewage treatment plant and the other from an intensive shrimp farm. The creeks discharged into the western side of Moreton Bay, a sub-tropical coastal embayment on the east coast of Australia. Characterization of water quality revealed significant differences between the creeks, and with unimpacted eastern Moreton Bay. The sewage creek had higher concentrations of dissolved nutrients (predominantly NO3-/NO2- and PO43-, compared to NH4+ in the shrimp creek). In contrast, the shrimp creek was more turbid and had higher phytoplankton productivity. Beyond 750 m from the creek mouths, water quality parameters were indistinguishable from eastern Moreton Bay values. Biological indicators detected significant impacts up to 4 km beyond the creek mouths (reference site). Elevated plant delta N-15 values ranged from 10.4-19.6 parts per thousand at the site of sewage discharge to 2.9-4.5 parts per thousand at the reference site. The free amino acid concentration and composition of seagrass and macroalgae was used to distinguish between the uptake of sewage and shrimp derived N. Proline (seagrass) and serine (macroalgae) were high in sewage impacted plants and glutamine (seagrass) and alanine (macroalgae) were high in plants impacted by shrimp effluent. The delta N-15 isotopic signatures and free amino acid composition of inhabitant flora indicated that sewage N extended further from the creek mouths than shrimp N. The combination of physical/chemical and biological indicators used in this study was effective in distinguishing the composition and subsequent impacts of aquaculture and sewage effluent on the receiving waters. (C) 2001 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To test the effect of liquid feeds on the responses to splanchnic ischaemia of a continuous rapid response PCO2 sensor inserted in the jejunum. Design: Prospective experimental animal study in a university research laboratory. Subjects: Adult male Wistar rats. Interventions: Adult male Wistar rats (285-425 g) were anaethetised with sodium pentobarbitone 60 mg/ kg i.p. and ventilated with 100 % oxygen and isoflurane via tracheostomy to a PaCO2 of 30-40 mmHg. A sensor was inserted into the mid-jejunum to record PCO2 every second. Distal aortic pressure was transduced. Four control rats received no feeds whilst in another four rats liquid feed was infused into the proximal jejunum at 3 ml/h. In each rat five episodes of splanchnic ischaemia were induced by 2-min elevations of an aortic sling to a mean distal aortic pressure of 30 mmHg. Measurements and main results: PCO2 elevations were always detectable, usually less than a minute from the onset of splanchnic ischaemia in both fed and unfed rats, with no difference in mean times to detectable response. In the fed rats there was a small but significant increase in the time to peak sensor response (196 +/- 16 vs. 180 +/- 12 s) and a trend towards an elevated mean baseline luminal PCO2 (67 +/- 9 vs. 55 +/- 4 mmHg). Conclusions: Brief episodes of splanchnic ischaemia were tracked successfully by a rapid response jejunal continuous PCO2 sensor during the infusion of a proprietary liquid feed preparation despite minor changes in PCO2 response characteristics and a possible elevation in baseline luminal PCO2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The present study aimed to investigate the feasibility and practicalities or testing children in special school settings using transient evoked otoacoustic emissions (TEOAE) and tympanometry. Children studying in special schools, particularly those with intellectual impairment, may be highly susceptible to hearing pathologies and can be difficult to assess using traditional test batteries. Researchers have recently suggested the possible applicability of TEOAE testing. in lieu of conventional behavioral methods, as a hearing screening device for persons with intellectual impairment. However, to date. few publications have detailed the particulars and results of such testing. Methods: A total of 489 children, with a mean age of 9.6 years, were tested in 15 special schools. Case information was obtained regarding birth history, medical history and type,degree of impairment, for later comparison with screening results. TEOAEs were collected using Quickscreen mode of the ILO292 Otodynamics Analyzer, whilst tympanometry was performed utilizing a Madsen Zodiac 901 Middle Ear Analyzer. Results: In total, 80% of students were able to be tested using TEOAEs. Average test time per ear was 2 min. However, a large proportion (40 of those able to be tested) failed TEOAE testing in at least one ear. No significant effects were found between could-not-test (CNT) cases and case history factors, A significant difference in TEOAE failure rates was found across history of neonatal special care nursery residency and history of parental concern regarding possible hearing impairment. Failure rates were higher for those who indicated positive histories. A total of 74% of subjects could be tested using tympanometry, with 25% of those able to be tested failing in at least one ear. Notably, neither type nor degree of impairment had any significant bearing on CNT or failure rates for tympanometry or TEOAE screening. Conclusions: Findings of the present investigation lend support to the review of hearing screening programs for children in special schools. with TEOAEs presenting as a potential alternative procedure. Further examination of the performance measures of protocols incorporating TEOAEs would now be advantageous. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.