999 resultados para Electrode position
Resumo:
Purpose: To examine the effects of gaze position and optical blur, similar to that used in multifocal corrections, on stepping accuracy for a precision stepping task among older adults. Methods: Nineteen healthy older adults (mean age, 71.6 +/- 8.8 years) with normal vision performed a series of precision stepping tasks onto a fixed target. The stepping tasks were performed using a repeated-measures design for three gaze positions (fixating on the stepping target as well as 30 and 60 cm farther forward of the stepping target) and two visual conditions (best-corrected vision and with +2.50DS blur). Participants' gaze position was tracked using a head-mounted eye tracker. Absolute, anteroposterior, and mediolateral foot placement errors and within-subject foot placement variability were calculated from the locations of foot and floor-mounted retroreflective markers captured by flash photography of the final foot position. Results: Participants made significantly larger absolute and anteroposterior foot placement errors and exhibited greater foot placement variability when their gaze was directed farther forward of the stepping target. Blur led to significantly increased absolute and anteroposterior foot placement errors and increased foot placement variability. Furthermore, blur differentially increased the absolute and anteroposterior foot placement errors and variability when gaze was directed 60 cm farther forward of the stepping target. Conclusions: Increasing gaze position farther ahead from stepping locations and the presence of blur negatively impact the stepping accuracy of older adults. These findings indicate that blur, similar to that used in multifocal corrections, has the potential to increase the risk of trips and falls among older populations when negotiating challenging environments where precision stepping is required, particularly as gaze is directed farther ahead from stepping locations when walking.
Resumo:
The conformationally restricted CHO-L-Met-Xxx-L-Phe-OY (where Xxx = Aib, Ac3c, Ac5c, Ac6c, and Ac7c; Y = H, Me) tripeptides, analogs of the chemoattractant CHO-L-Met-L-Leu-L-Phe-OH, have been synthesized in solution by classical methods and fully characterized. Compounds were compared to determine the combined effect of backbone conformational preferences and side-chain bulkiness on the relation of three-dimensional structure to biological activity. Each peptide was tested for its ability to induce granule enzyme secretion from rabbit peritoneal polymorphonuclear leukocytes. In parallel, a conformational analysis on the CHO-blocked peptide and their tertbutyloxycarbonylated synthetic precursors was performed in the crystal state and in solution using X-ray diffraction, infrared absorption, and 1H nuclear magnetic resonance. The biological and conformational data are discussed in relation to the proposed model of the chemotactic peptide receptor of rabbit neutrophils.
Resumo:
A simple analog instrumentation for Electrical Impedance Tomography is developed and calibrated using the practical phantoms. A constant current injector consisting of a modified Howland voltage controlled current source fed by a voltage controlled oscillator is developed to inject a constant current to the phantom boundary. An instrumentation amplifier, 50 Hz notch filter and a narrow band pass filter are developed and used for signal conditioning. Practical biological phantoms are developed and the forward problem is studied to calibrate the EIT-instrumentation. An array of sixteen stainless steel electrodes is developed and placed inside the phantom tank filled with KCl solution. 1 mA, 50 kHz sinusoidal current is injected at the phantom boundary using adjacent current injection protocol. The differential potentials developed at the voltage electrodes are measured for sixteen current injections. Differential voltage signal is passed through an instrumentation amplifier and a filtering block and measured by a digital multimeter. A forward solver is developed using Finite Element Method in MATLAB7.0 for solving the EIT governing equation. Differential potentials are numerically calculated using the forward solver with a simulated current and bathing solution conductivity. Measured potential data is compared with the differential potentials calculated for calibrating the instrumentation to acquire the voltage data suitable for better image reconstruction.
Resumo:
Hydrothermal treatment of a slurry of badly crystalline (beta(bc)) nickel hydroxide at different temperatures (65-170 degrees C) results in the progressive ordering of the structure by the step-wise elimination of disorders. Interstratification is eliminated at 140 degrees C, while cation vacancies are eliminated at 170 degrees C. A small percentage of stacking faults continue to persist even in `crystalline' samples. Electrochemical investigations show that the crystalline nickel hydroxide has a very low (0.4 e/Ni) reversible charge storage capacity. An incidence of at least 15% stacking faults combined with cation vacancies is essential for nickel hydroxide to perform close to its theoretical (1 e/ Ni) discharge capacity. (c) 2005 The Electrochemical Society.
TV-toimittajan kolmannen position vuoroista Venäjän televisiossa: dialogipartikkelit ja interventiot
Resumo:
16-electrode phantoms are developed and studied with a simple instrumentation developed for Electrical Impedance Tomography. An analog instrumentation is developed with a sinusoidal current generator and signal conditioner circuit. Current generator is developed withmodified Howland constant current source fed by a voltage controlled oscillator and the signal conditioner circuit consisting of an instrumentation amplifier and a narrow band pass filter. Electronic hardware is connected to the electrodes through a DIP switch based multiplexer module. Phantoms with different electrode size and position are developed and the EIT forward problem is studied using the forward solver. A low frequency low magnitude sinusoidal current is injected to the surface electrodes surrounding the phantom boundary and the differential potential is measured by a digital multimeter. Comparing measured potential with the simulated data it is intended to reduce the measurement error and an optimum phantom geometry is suggested. Result shows that the common mode electrode reduces the common mode error of the EIT electronics and reduces the error potential in the measured data. Differential potential is reduced up to 67 mV at the voltage electrode pair opposite to the current electrodes. Offset potential is measured and subtracted from the measured data for further correction. It is noticed that the potential data pattern depends on the electrode width and the optimum electrode width is suggested. It is also observed that measured potential becomes acceptable with a 20 mm solution column above and below the electrode array level.
Resumo:
A detailed account of the morphological, staining, penicillin sensitivity and serological peculiarities of five strains of an oxalate-decomposing bacterium including the well-recognized strain Vibrio extorquens, has been given. Inasmuch as all the strains share many of the characteristics of the genus Arthrobacter and not Vibrio the desirability of placing the bacterium in the former genus for the time being has been suggested. The possibility of the strains falling under an altogether new genus which represent a phylogenic link between the pseudomonads and diphtheroids has been speculated.
Resumo:
This paper makes explicit the relation between relative part position and kinematic freedom of the parts which is implicitly available in the literature. An extensive set of representative papers in the areas of assembly and kinematic modelling is reviewed to specifically identify how the ideas in the two areas are related and influencing the development of each other. The papers are categorised by the approaches followed in the specification, representation, and solution of the part relations. It is observed that the extent of the part geometry is not respected in modelling schemes and as a result, the causal flow of events (proximity–contact–mobility) during the assembling process is not realised in the existing modelling paradigms, which are focusing on either the relative positioning problem or the relative motion problem. Though an assembly is a static description of part configuration, achievement of this configuration requires availability of relative motion for bringing parts together during the assembly process. On the other hand, the kinematic freedom of a part depends on the nature of contacting regions with other parts in its static configuration. These two problems are thus related through the contact geometry. The chronology of the approaches that significantly contributed to the development of the subject is also included in the paper.
Resumo:
The paper presents simple graphical procedures for position synthesis of plane linkage mechanisms to generate functions of two independent variables. The procedures are based on point-position reduction and permit synthesis of the linkage to satisfy up to six arbitrarily selected precision positions.
Resumo:
The paper presents simple graphical procedures for the position synthesis of plane linkage mechanisms with sliding inputs and output to generate functions of two independent variables. The procedures are based on point position reduction and permit synthesis of the linkage to satisfy up to five arbitrarily selected precision positions.
Resumo:
Current-potential relationships are derived for porous electrode systems following a homogeneous model and whenadsorbed intermediates participate in the electrode reaction. Limiting Tafel slopes were deduced and compared with thecorresponding behavior on planar electrode systems. The theoretical results showed doubling of Tafel slopes when theslow-step is a charge-transfer reaction and a nonlogarithmic current-voltage behavior when the slow-step is a chemical reaction.Comparison of the experimental results with theory for the case of oxygen reduction on carbon surfaces in alkalinemedia indicates that a slow chemical reaction following the initial charge-transfer reaction to be the likely rate-controllingstep. Theoretical relationships are utilized to determine the exchange current density and the surface coverage by the adsorbedintermediates during the course of oxygen reduction from alkaline solutions on "carbon." Tafel slope measurementson planar and porous electrodes for the same reaction are suggested as one of the diagnostic criteria for elucidatingthe mechanistic pathways of electrochemical reactions.
Resumo:
The systems formalism is used to obtain the interfacial concentration transients for power-law current input at an expanding plane electrode. The explicit results for the concentration transients obtained here pertain to arbitrary homogeneous reaction schemes coupled to the oxidant and reductant of a single charge-transfer step and the power-law form without and with a preceding blank period (for two types of power-law current profile, say, (i) I(t) = I0(t−t0)q for t greater-or-equal, slanted t0, I(t) = 0 for t < t0; and (ii) I(t) = I0tq for t greater-or-equal, slanted t0, I(t) = 0 for t < t0). Finally the potential transients are obtained using Padé approximants. The results of Galvez et al. (for E, CE, EC, aC) (J. Electroanal. Chem., 132 (1982) 15; 146 (1983) 221, 233, 243), Molina et al. (for E) (J. Electroanal. Chem., 227 (1987) 1 and Kies (for E) (J. Electroanal. Chem., 45 (1973) 71) are obtained as special cases.
Resumo:
Statistical methods for optimizing the morphology of oxide-based, bifunctional oxygen electrodes for use in rechargeable metal/air batteries are examined with regard to binder composition, compaction time, and compaction load. Results show that LaNiO3 with PTFE binder in a nickel mesh envelope provides a satisfactory electrode.
Resumo:
The use of fractional-factorial methods in the optimization of porous-carbon electrode structure is discussed with respect to weight-loss of carbon during gas treatment, weight and mixing time of binder, compaction temperature, time and pressure, and pressure of feed gas. The experimental optimization of an air electrode in alkaline solution is described.
Resumo:
Silicon strip detectors are fast, cost-effective and have an excellent spatial resolution. They are widely used in many high-energy physics experiments. Modern high energy physics experiments impose harsh operation conditions on the detectors, e.g., of LHC experiments. The high radiation doses cause the detectors to eventually fail as a result of excessive radiation damage. This has led to a need to study radiation tolerance using various techniques. At the same time, a need to operate sensors approaching the end their lifetimes has arisen. The goal of this work is to demonstrate that novel detectors can survive the environment that is foreseen for future high-energy physics experiments. To reach this goal, measurement apparatuses are built. The devices are then used to measure the properties of irradiated detectors. The measurement data are analyzed, and conclusions are drawn. Three measurement apparatuses built as a part of this work are described: two telescopes measuring the tracks of the beam of a particle accelerator and one telescope measuring the tracks of cosmic particles. The telescopes comprise layers of reference detectors providing the reference track, slots for the devices under test, the supporting mechanics, electronics, software, and the trigger system. All three devices work. The differences between these devices are discussed. The reconstruction of the reference tracks and analysis of the device under test are presented. Traditionally, silicon detectors have produced a very clear response to the particles being measured. In the case of detectors nearing the end of their lifefimes, this is no longer true. A new method benefitting from the reference tracks to form clusters is presented. The method provides less biased results compared to the traditional analysis, especially when studying the response of heavily irradiated detectors. Means to avoid false results in demonstrating the particle-finding capabilities of a detector are also discussed. The devices and analysis methods are primarily used to study strip detectors made of Magnetic Czochralski silicon. The detectors studied were irradiated to various fluences prior to measurement. The results show that Magnetic Czochralski silicon has a good radiation tolerance and is suitable for future high-energy physics experiments.