1000 resultados para Electrical behaviors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peer-based interventions have the potential to enhance quality of life and functioning; however their role specifically within the older population has not been fully investigated. The objective of this review therefore is to locate, appraise and synthesise evidence on the effectiveness of peer-based interventions on changes in health behaviors, specifically for the older population. The specific question to be answered is: “what is the effectiveness of peer-based interventions on health promoting behaviors in older adults, when compared to non peer-based interventions?”

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental investigations into the dielectric properties of epoxy-ZnO nanocomposites at different filler loadings reveal few unique behaviors (at certain filler loadings) and also advantageous characteristics in contrast to the properties obtained for the corresponding microcomposites. Results demonstrate that in nanocomposites, it is possible to achieve lower values of permittivity and tan delta with respect to unfilled epoxy over a wide frequency range. Analysis of the results attributes this interesting observation to the interaction dynamics between the epoxy chains and the ZnO nanoparticles at the interfacial area. The dc volume resistivities and ac dielectric strengths of nanocomposites were also experimentally determined in the present study and the obtained characteristics are found to be different as compared to the results obtained for microcomposites. The volume fraction and nature of the interfaces in the bulk of the composites seem to influence this difference in the examined dielectric properties of the nanocomposites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents some results from preliminary analyses of the data of an international online survey of bicycle riders, who reported riding at least once a month. On 4 July 2015, data from 7528 participants from 17 countries was available in the survey, and were subsequently cleaned and checked for consistency. The median distance ridden ranged from 30 km/week in Israel to 150 km/week in Greece (overall median 54 km/week). City/hybrid bicycles were the most common type of bicycle ridden (44%), followed by mountain (20%) and road bikes (15%). Almost half (47%) of the respondents rode “nearly daily”. About a quarter rode daily to work or study (27%). Overall, 40% of respondents reported wearing a helmet ‘always’, varying from 2% in the Netherlands to 80% in Norway, while 25% reported ‘never’ wearing a helmet. Thus, individuals appeared to consistently either use or not use helmets. Helmet wearing rates were generally higher when riding for health/fitness than other purposes and appeared to be little affected by the type of riding location, but some divergences in these patterns were found among countries. Almost 29% of respondents reported being involved in at least one bicycle crash in the last year (ranging from 12% in Israel to 53% in Turkey). Among the most severe crashes for each respondent, about half of the crashes involved falling off a bicycle. Just under 10% of the most severe crashes for each respondent were reported to police. Among the bicycle-motor vehicle crashes, only a third were reported to police. Further analyses will address questions regarding the influence of factors such as demographic characteristics, type of bicycle ridden, and attitudes on both bi-cycle use and helmet wearing rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the electrical discharge resistant characteristics of epoxy nanocomposite systems with SiO2 and Al2O3 nano-fillers. A comparative study is performed between unfilled epoxy systems, nanoparticle filled epoxy systems and a bimodal system containing both micrometer and nanometer sized fillers of the same material. The samples are exposed to surface discharges and the levels of surface degradation are analyzed through SEM and surface roughness measurements. Significant variations were observed in the electrical discharge resistant characteristics between the different composite systems and it is seen that the introduction of nano-fillers to epoxy is advantageous in improving the electrical discharge resistance of epoxy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indium sulphide (INS) is a III-VI compound semiconductor and crystallizes in the orthorhombic structure with a space group D~(Pmnn). The lattice parameters at room temperature and atmospheric pressure are: a = 3.944 A, b = 4.447 A and c= 10.648#, [1, 2]. The crystal structure comprises an ethane-like SalnlnS3 atomic arrangement;the SalnInS3 groups are mutually linked by sharing S corners and form a three-dimensional network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polyaniline (PANI)/para-toluene sulfonic acid (pTSA) and PANI/pTSA-TiO2 composites were prepared using chemical method and characterized by infrared spectroscopy (IR), powder X-ray diffraction (XRD), scanning electron microscopy (SEM). The electrical conductivity and magnetic properties were also measured. In corroboration with XRD, the micrographs of SEM indicated the homogeneous dispersion of TiO nanoparticles in bulk PANI/pTSA matrix. Conductivity of the PANI/pTSA-TiO2 was higher than the PAN[/pTSA, and the maximum conductivity obtained was 9.48 (S/cm) at 5 wt% of TiO2. Using SQUID magnetometer, it was found that PANI/pTSA was either paramagnetic or weakly ferromagnetic from 300 K down to 5 K with H-C approximate to 30 Oe and M-r approximate to 0.015 emu/g. On the other hand,PANI/pTSA-TiO2 was diamagnetic from 300 K down to about 50 K and below which it was weakly ferromagnetic. Furthermore, a nearly temperature-independent magnetization was observed in both the cases down to 50 K and below which the magnetization increased rapidly (a Curie like susceptibility was observed). The Pauli susceptibility (chi(pauli)) was calculated to be about 4.8 X 10(-5) and 1.6 x 10(-5)emug(-1) Oe(-1) K for PANI/pTSA and PANI/pTSA-TiO2, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical resistivity of bulk amorphous Al23T77 samples has been studied as a function of pressure (up to 80 kbar) and temperature (down to 77 K). At atmospheric pressure the temperature dependence of resistivity obeys the relation = π0 exp(δE/RT) with two activation energies. In the temperature range 300 K T > 234 K the activation energy is 0.58 eV and for 234 >T 185 K the value is δE = 0.30 ev. The activation energy has been measured as a function of pressure. The electrical resistivity decreases exponentially with the increase of pressure and at 70 kbar pressure the electrical behaviour of the sample shows a metallic nature with a positive temperature coefficient. The high pressure phase of the sample is found to be a crystalline hexagonal phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical muscle stimulation (EMS) devices are being marketed as weight/ fat loss devices throughout the world. Commercially available stimulators have the ability to evoke muscle contractions that may affect caloric expenditure while the device is being used. The aim of this study was to test the effects of two different EMS devices (Abtronic and Feminique) on oxygen consumption at rest. Subjects arrived for testing after an overnight fast, had the devices fitted, and then positioned supine with expired air measured to determine oxygen consumption. After a 10-minute acclimation period, oxygen consumption was measured for 20 minutes with the device switched off (resting) then 20 minutes with the device switched on (stimulated). There were no significant differences (p > 0.05) in oxygen consumption between the resting and stimulated periods with either the Abtronic (mean +/- SD; resting, 3.40 +/- 0.44; stimulated, 3.45 +/- 0.53 ml of O2[middle dot]kg-1[middle dot]min-1) or the Feminique (resting, 3.73 +/- 0.45; stimulated, 3.75 +/- 0.46 ml of O2[middle dot]kg-1[middle dot]min-1). In summary, the EMS devices tested had no effect on oxygen consumption during muscle stimulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of pressure on the electrical resistivity of bulk Si20Te80 glass is reported. Results of calorimetric, X-ray and transmission electron microscopy investigations at different stages of crystallization of bulk Si20Te80 glass are also presented. A pressure induced glass-to-crystal transition occurs at a pressure of 7 GPa. Pressure and temperature dependence of the electrical resistivity of Si20Te80 glass show the observed transition is a pressure induced glassy semiconductor to crystalline metal transition. The glass also exhibits a double Tg effect and double stage crystallization, under heating. The differences between the temperature induced crystallization (primary crystallization) and pressure induced congruent crystallization are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The DC and AC conductivity studies of As---Se glasses over a wide range of compositions have been reported and discussed. The contribution to conductivity from transport among extended states has been delineated and the possible existence of a characteristic temperature is indicated. Two conductivity maxima have been observed as a function of composition in AC conductivities at lower temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, effects of stimulus repetition and change in a continuous stimulus stream on the processing of somatosensory information in the human brain were studied. Human scalp-recorded somatosensory event-related potentials (ERPs) and magnetoencephalographic (MEG) responses rapidly diminished with stimulus repetition when mechanical or electric stimuli were applied to fingers. On the contrary, when the ERPs and multi-unit a ctivity (MUA) were directly recorded from the primary (SI) and secondary (SII) somatosensory cortices in a monkey, there was no marked decrement in the somatosensory responses as a function of stimulus repetition. These results suggest that this rate effect is not due to the response diminution in the SI and SII cortices. Obviously the responses to the first stimulus after a long "silent" period are nhanced due to unspecific initial orientation, originating in more broadly distributed and/or deeper neural structures, perhaps in the prefrontal cortices. With fast repetition rates not only the late unspecific but also some early specific somatosensory ERPs were diminished in amplitude. The fast decrease of the ERPs as a function of stimulus repetition is mainly due to the disappearance of the orientation effect and with faster repetition rates additively due to stimulus specific refractoriness. A sudden infrequent change in the continuous stimulus stream also enhanced somatosensory MEG responses to electric stimuli applied to different fingers. These responses were quite similar to those elicited by the deviant stimuli alone when the frequent standard stimuli were omitted. This enhancement was obviously due to the release from refractoriness because the neural structures generating the responses to the infrequent deviants had more time to recover from the refractoriness than the respective structures for the standards. Infrequent deviant mechanical stimuli among frequent standard stimuli also enhanced somatosensory ERPs and, in addition, they elicited a new negative wave which did not occur in the deviants-alone condition. This extra negativity could be recorded to deviations in the stimulation site and in the frequency of the vibratory stimuli. This response is probably a somatosensory analogue of the auditory mismatch negativity (MMN) which has been suggested to reflect a neural mismatch process between the sensory input and the sensory memory trace.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuroimaging studies have shown neuromuscular electrical stimulation (NMES)-evoked movements activate regions of the cortical sensorimotor network, including the primary sensorimotor cortex (SMC), premotor cortex (PMC), supplementary motor area (SMA), and secondary somatosensory area (S2), as well as regions of the prefrontal cortex (PFC) known to be involved in pain processing. The aim of this study, on nine healthy subjects, was to compare the cortical network activation profile and pain ratings during NMES of the right forearm wrist extensor muscles at increasing current intensities up to and slightly over the individual maximal tolerated intensity (MTI), and with reference to voluntary (VOL) wrist extension movements. By exploiting the capability of the multi-channel time domain functional near-infrared spectroscopy technique to relate depth information to the photon time-of-flight, the cortical and superficial oxygenated (O2Hb) and deoxygenated (HHb) hemoglobin concentrations were estimated. The O2Hb and HHb maps obtained using the General Linear Model (NIRS-SPM) analysis method, showed that the VOL and NMES-evoked movements significantly increased activation (i.e., increase in O2Hb and corresponding decrease in HHb) in the cortical layer of the contralateral sensorimotor network (SMC, PMC/SMA, and S2). However, the level and area of contralateral sensorimotor network (including PFC) activation was significantly greater for NMES than VOL. Furthermore, there was greater bilateral sensorimotor network activation with the high NMES current intensities which corresponded with increased pain ratings. In conclusion, our findings suggest that greater bilateral sensorimotor network activation profile with high NMES current intensities could be in part attributable to increased attentional/pain processing and to increased bilateral sensorimotor integration in these cortical regions.