910 resultados para EPIRETINAL MEMBRANES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a nonequlibrium approach for the study of a flexible bilayer whose two components induce distinct curvatures. In turn, the two components are interconverted by an externally promoted reaction. Phase separation of the two species in the surface results in the growth of domains characterized by different local composition and curvature modulations. This domain growth is limited by the effective mixing due to the interconversion reaction, leading to a finite characteristic domain size. In addition to these effects, first introduced in our earlier work [ Phys. Rev. E 71 051906 (2005)], the important new feature is the assumption that the reactive process actively affects the local curvature of the bilayer. Specifically, we suggest that a force energetically activated by external sources causes a modification of the shape of the membrane at the reaction site. Our results show the appearance of a rich and robust dynamical phenomenology that includes the generation of traveling and/or oscillatory patterns. Linear stability analysis, amplitude equations, and numerical simulations of the model kinetic equations confirm the occurrence of these spatiotemporal behaviors in nonequilibrium reactive bilayers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The genotyping of human papillomaviruses (HPV) is essential for the surveillance of HPV vaccines. We describe and validate a low-cost PGMY-based PCR assay (PGMY-CHUV) for the genotyping of 31 HPV by reverse blotting hybridization (RBH). Genotype-specific detection limits were 50 to 500 genome equivalents per reaction. RBH was 100% specific and 98.61% sensitive using DNA sequencing as the gold standard (n = 1,024 samples). PGMY-CHUV was compared to the validated and commercially available linear array (Roche) on 200 samples. Both assays identified the same positive (n = 182) and negative samples (n = 18). Seventy-six percent of the positives were fully concordant after restricting the comparison to the 28 genotypes shared by both assays. At the genotypic level, agreement was 83% (285/344 genotype-sample combinations; κ of 0.987 for single infections and 0.853 for multiple infections). Fifty-seven of the 59 discordant cases were associated with multiple infections and with the weakest genotypes within each sample (P < 0.0001). PGMY-CHUV was significantly more sensitive for HPV56 (P = 0.0026) and could unambiguously identify HPV52 in mixed infections. PGMY-CHUV was reproducible on repeat testing (n = 275 samples; 392 genotype-sample combinations; κ of 0.933) involving different reagents lots and different technicians. Discordant results (n = 47) were significantly associated with the weakest genotypes in samples with multiple infections (P < 0.0001). Successful participation in proficiency testing also supported the robustness of this assay. The PGMY-CHUV reagent costs were estimated at $2.40 per sample using the least expensive yet proficient genotyping algorithm that also included quality control. This assay may be used in low-resource laboratories that have sufficient manpower and PCR expertise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the histologic features of cellular retinal fragments on the internal limiting membrane (ILM) removed during idiopathic macular epiretinal membrane (MEM) peeling surgery with and without the aid of indocyanine green (ICG) diluted in 5% glucose. METHODS: ILM specimens removed from 88 eyes during idiopathic MEM surgery between 1995 and 2003 were reviewed retrospectively. Histologic analysis focused on the presence and characteristics of retinal fragments on the retinal surface of the ILM. Statistical analysis compared the results between group I (conventional surgery) and group II (ICG-assisted peeling). RESULTS: Seventy-one eyes underwent MEM surgery without the aid of ICG (group I) and seventeen underwent MEM ICG-assisted surgery (group II). The amount of Müller cell debris on the retinal surface of the ILM was more significant in the group I than in the group II (40.8 vs. 11.8; P = 0.024). Large fragments of Müller cells were more frequently observed in the group I (no ICG) than in the group II (ICG) (63.4 vs. 23.5%; P = 0.003). CONCLUSIONS: The use of ICG diluted with 5% glucose in ILM removal during MEM surgery was associated with less retinal debris attached to the retinal face of the ILM compared with surgery in which ICG was not used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME Les membranes néovasculaires (MNV) compliquent diverses pathologies ophtalmiques. Elles sont à l'origine d'une importante baisse de l'acuité visuelle lorsque elles se situent à proximité de la fovéa. A l'heure actuelle, peu de données relatives à leur association aux pathologies inflammatoires de l'oeil (uvéites) existent. Dans ce travail, la fréquence de MNV a été évaluée parmi 643 patients avec uvéite. Leur impact sur l'acuité visuelle ainsi que le pronostic en fonction des différents traitements effectués ont été étudiés. Les dossiers des 643 patients souffrant d'uvéite ont été étudiés. Les patients présentant une MNV ont été classés en trois groupes en fonction de l'importance de l'inflammation intraoculaire: élevée (2+ cellules dans le vitré), moyenne (1/2+ à 1+ cellules dans le vitré) ou absente (0 cellules dans le vitré). L'évolution de l'acuité visuelle fut considérée comme favorable (+VA: maintient de l'acuité visuelle ou gain d'une ou plusieurs lignes de Snellen) ou défavorable (-VA: perte d'une ou plusieurs lignes Snellen). Chez 9 patients, le traitement instauré a consisté, initialement, en l'administration orale de corticostéroïdes (CST) à haute dose qui, dans le cas d'évolution favorable (-FVA ou régression angiographique de la MNV), était arrêtée en doses dégressives. Dans les évolutions défavorables (-VA ou progression angiographique de la MNV), les CST étaient maintenus à dose moyenne en complémentation d'un traitement par thérapie laser (photothérapie dynamique (PDT), thermothérapie transpupillaire (TTT) ou laser Argon). Ce protocole thérapeutique ne fut appliqué chez trois patients en raison de la non disponibilité de PDT ou d'un diagnostic manqué d'uvéite. Douze patients sur 643 avec uvéite ont présenté une MNV. L'impact visuel moyen était de 4.5 lignes de Snellen et le temps moyen de suivi était de 19.5 mois. Deux patients avec inflammation intraoculaire élevée ont évolué favorablement sous CST seuls. Huit patients avec inflammation intraoculaire moyenne ont évolué favorablement sous CST seuls chez trois patients, alors que quatre patients ont nécessité une thérapie laser additionnelle. Le dernier patient ne fut traité que par thérapie laser sans CST (diagnostic manqué d'uvéite). Deux patients sans inflammation intraoculaire ont eu un pronostic défavorable sous CST seuls (pas d'autre alternative thérapeutique). Notre étude a démontré que les MNV sont une complication rare de l'uvéite qui, après traitement adéquat, ont un pronostic visuel relativement favorable. Bien que les CST semblent être la première modalité thérapeutique, les traitements laser devraient être adoptés tôt dans les situations d'inflammation intraoculaire moyenne ou absente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Membrane filtration has become increasingly attractive in the processing of both foodand biotechnological products. However, the poor selectivity of the membranes and fouling are the critical factors limiting the development of UF systems for the specific fractionation of protein mixtures. This thesis gives an overview on fractionation of proteins from model protein solutions or from biological solutions. An attempt was made to improve the selectivity of the available membranes by modifying the membranes and by exploiting the different electrostatic interactions between the proteins and the membrane pore surfaces. Fractionation and UF behavior of proteins in the model solutions and in the corresponding biological solutions were compared. Characterization of the membranes and protein adsorptionto the membrane were investigated with combined flux and streaming potential studies. It has been shown that fouling of the membranes can be reduced using "self-rejecting" membranes at pH values where electrostatic repulsion is achieved between the membrane and the proteins in solution. This effect is best shown in UF of dilute single protein solutions at low ionic strengths and low pressures. Fractionation of model proteins in single, binary, and ternary solutionshas been carried out. The results have been compared to the results obtained from fractination of biological solutions. It was generally observed that fractination of proteins from biological solutions are more difficult to carry out owingto the presence of non studied protein components with different properties. Itcan be generally concluded that it is easier to enrich the smaller protein in the permeate but it is also possible to enrich the larger protein in the permeateat pH values close to the isoelectric point of the protein. It should be possible to find an optimal flux and modification to effectively improve the fractination of proteins even with very similar molar masses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Membrane-permeable calmodulin inhibitors, such as the napthalenesulfonamide derivatives W-7/W-13, trifluoperazine, and calmidazolium, are used widely to investigate the role of calcium/calmodulin (Ca2+/CaM) in living cells. If two chemically different inhibitors (e.g. W-7 and trifluoperazine) produce similar effects, investigators often assume the effects are due to CaM inhibition. Zeta potential measurements, however, show that these amphipathic weak bases bind to phospholipid vesicles at the same concentrations as they inhibit Ca 2 /CaM; this suggests that they also bind to the inner leaflet of the plasma membrane, reducing its negative electrostatic surface potential. This change will cause electrostatically bound clusters of basic residues on peripheral (e.g. Src and K-Ras4B) and integral (e.g. epidermal growth factor receptor (EGFR)) proteins to translocate from the membrane to the cytoplasm. We measured inhibitor-mediated translocation of a simple basic peptide corresponding to the calmodulin-binding juxtamembrane region of the EGFR on model membranes; W-7/W-13 causes translocation of this peptide from membrane to solution, suggesting that caution must be exercised when interpreting the results obtained with these inhibitors in living cells. We present evidence that they exert dual effects on autophosphorylation of EGFR;W-13 inhibits epidermal growth factordependent EGFR autophosphorylation under different experimental conditions, but in the absence of epidermal growth factor, W-13 stimulates autophosphorylation of the receptor in four different cell types. Our interpretation is that the former effect is due toW-13inhibition of Ca 2 /CaM, but thelatter results could be due to binding of W-13 to the plasma membrane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open-label, randomized, cross-over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high-flux, Gambro, Stockholm, Sweden), B (Helixone high-flux, Fresenius), C (Xevonta high-flux, BBraun, Melsungen, Germany), and D (Helixone low-flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1-10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low- compared with the high-flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low-flux membrane correlated to higher blood pressure levels compared with the high-flux ones. The Helixone high-flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les membranes de dialyse à haut flux et à faible flux pourraient être liées à différents profils hemodynamiques pendant les séances de dialyse. Cette étude visait à comparer le profil hémodynamique des certains filtres de dialyse polysulfone couramment utilisés en Suisse. Nous avons réalisé une étude ouverte, cross-over, avec 25 pazients en hémodialyse On a comparés entre eux 4 filtres de polysulfone de la surface de 1 8 m2 A (Revaclear HF, Gambro), B (Helixone HF, Fresenius), C (Xevonta HF, BBraun) et D (Helixone LF Fresenius). Le profil hémodynamique a été mesuré en utilisant une technique non invasive et au patient a été demandé de fournir une opinion sur la tolérance à la seance de dialyse. La même membrane était utilisée pour 3 séances de suites Chaque semaine la membrane de dialyse était modifiée conformément à la séquence de randomisation. Pour chaque patient on a recueillie les données de 12 séances de dialyse. L'étude a été réalisé sur trois mois à compter de novembre 2012. Les analyses ont encore une fois montré la supériorité des filtres à haut débit comparés aux filtres à faible débit, et ne tendance à la supériorité du filtre Helixone (haut debit) comparé aux deux autres membranes. Les filtres à faible débit par rapport a ceux a haut debit sont associés ä une pression systolique et diastolique plus élevées a des résistances périphériques plus hautes et à un débit cardiaque plus faible L incidence d'épisodes d'hypotension en dialyse était la suivante: Revaclear HF (A) 70 Helixone HF (B) 87 Xevonta HF 73 (C), Helixone LF (D) 75. Le nombre d'épisodes d hypotension associée au filtre B était supérieure, de manière significative. La membrane à faible flux était associée à une pression artérielle supérieure à celles des membranes de haut flux. La membrane à haut flux Helixone garantie la meilleure efficacité de dialyse. Malheureusement, la même membrane est associée à une augmentation de l'incidence des épisodes d'hypotension, probablement due à un déséquilibré hé à l'efficacité de la dialyse. Malgré ces résultats, la tolérance subjective pour les différents filtres était comparable.