851 resultados para Dwellings -- Heating and ventilation -- Environmental aspects


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We provide new evidence on sea surface temperature (SST) variations and paleoceanographic/paleoenvironmental changes over the past 1500 years for the north Aegean Sea (NE Mediterranean). The reconstructions are based on multiproxy analyses, obtained from the high resolution (decadal to multidecadal) marine record M2 retrieved from the Athos basin. Reconstructed SSTs show an increase from ca. 850 to 950 AD and from ca. 1100 to 1300 AD. A cooling phase of almost 1.5 �C is observed from ca. 1600 AD to 1700 AD. This seems to have been the starting point of a continuous SST warming trend until the end of the reconstructed period, interrupted by two prominent cooling events at 1832 ± 15 AD and 1995 ± 1 AD. Application of an adaptive Kernel smoothing suggests that the current warming in the reconstructed SSTs of the north Aegean might be unprecedented in the context of the past 1500 years. Internal variability in atmospheric/oceanic circulations systems as well as external forcing as solar radiation and volcanic activity could have affected temperature variations in the north Aegean Sea over the past 1500 years. The marked temperature drop of approximately ~2 �C at 1832 ± 15 yr AD could be related to the 1809 АD ‘unknown’ and the 1815 AD Tambora volcanic eruptions. Paleoenvironmental proxy-indices of the M2 record show enhanced riverine/continental inputs in the northern Aegean after ca. 1450 AD. The paleoclimatic evidence derived from the M2 record is combined with a socio-environmental study of the history of the north Aegean region. We show that the cultivation of temperature-sensitive crops, i.e. walnut, vine and olive, co-occurred with stable and warmer temperatures, while its end coincided with a significant episode of cooler temperatures. Periods of agricultural growth in Macedonia coincide with periods of warmer and more stable SSTs, but further exploration is required in order to identify the causal links behind the observed phenomena. The Black Death likely caused major changes in agricultural activity in the north Aegean region, as reflected in the pollen data from land sites of Macedonia and the M2 proxy-reconstructions. Finally, we conclude that the early modern peaks in mountain vegetation in the Rhodope and Macedonia highlands, visible also in the M2 record, were very likely climate-driven.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Leiopelma hochstetteri is an endangered New Zealand frog now confined to isolated populations scattered across the North Island. A better understanding of its past, current and predicted future environmental suitability will contribute to its conservation which is in jeopardy due to human activities, feral predators, disease and climate change. Here we use ecological niche modelling with all known occurrence data (N = 1708) and six determinant environmental variables to elucidate current, pre-human and future environmental suitability of this species. Comparison among independent runs, subfossil records and a clamping method allow validation of models. Many areas identified as currently suitable do not host any known populations. This apparent discrepancy could be explained by several non exclusive hypotheses: the areas have not been adequately surveyed and undiscovered populations still remain, the model is over simplistic; the species` sensitivity to fragmentation and small population size; biotic interactions; historical events. An additional outcome is that apparently suitable, but frog-less areas could be targeted for future translocations. Surprisingly, pre-human conditions do not differ markedly highlighting the possibility that the range of the species was broadly fragmented before human arrival. Nevertheless, some populations, particularly on the west of the North Island may have disappeared as a result of human mediated habitat modification. Future conditions are marked with higher temperatures, which are predicted to be favourable to the species. However, such virtual gain in suitable range will probably not benefit the species given the highly fragmented nature of existing habitat and the low dispersal ability of this species. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Genetic variation for environmental sensitivity indicates that animals are genetically different in their response to environmental factors. Environmental factors are either identifiable (e.g. temperature) and called macro-environmental or unknown and called micro-environmental. The objectives of this study were to develop a statistical method to estimate genetic parameters for macro- and micro-environmental sensitivities simultaneously, to investigate bias and precision of resulting estimates of genetic parameters and to develop and evaluate use of Akaike’s information criterion using h-likelihood to select the best fitting model. Methods: We assumed that genetic variation in macro- and micro-environmental sensitivities is expressed as genetic variance in the slope of a linear reaction norm and environmental variance, respectively. A reaction norm model to estimate genetic variance for macro-environmental sensitivity was combined with a structural model for residual variance to estimate genetic variance for micro-environmental sensitivity using a double hierarchical generalized linear model in ASReml. Akaike’s information criterion was constructed as model selection criterion using approximated h-likelihood. Populations of sires with large half-sib offspring groups were simulated to investigate bias and precision of estimated genetic parameters. Results: Designs with 100 sires, each with at least 100 offspring, are required to have standard deviations of estimated variances lower than 50% of the true value. When the number of offspring increased, standard deviations of estimates across replicates decreased substantially, especially for genetic variances of macro- and micro-environmental sensitivities. Standard deviations of estimated genetic correlations across replicates were quite large (between 0.1 and 0.4), especially when sires had few offspring. Practically, no bias was observed for estimates of any of the parameters. Using Akaike’s information criterion the true genetic model was selected as the best statistical model in at least 90% of 100 replicates when the number of offspring per sire was 100. Application of the model to lactation milk yield in dairy cattle showed that genetic variance for micro- and macro-environmental sensitivities existed. Conclusion: The algorithm and model selection criterion presented here can contribute to better understand genetic control of macro- and micro-environmental sensitivities. Designs or datasets should have at least 100 sires each with 100 offspring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Producing cost-competitive small and medium-sized solar cooling systems is currently a significant challenge. Due to system complexity, extensive engineering, design and equipment costs; the installation costs of solar thermal cooling systems are prohibitively high. In efforts to overcome these limitations, a novel sorption heat pump module has been developed and directly integrated into a solar thermal collector. The module comprises a fully encapsulated sorption tube containing hygroscopic salt sorbent and water as a refrigerant, sealed under vacuum with no moving parts. A 5.6m2 aperture area outdoor laboratory-scale system of sorption module integrated solar collectors was installed in Stockholm, Sweden and evaluated under constant re-cooling and chilled fluid return temperatures in order to assess collector performance. Measured average solar cooling COP was 0.19 with average cooling powers between 120 and 200 Wm-2 collector aperture area. It was observed that average collector cooling power is constant at daily insolation levels above 3.6 kWhm-2 with the cooling energy produced being proportional to solar insolation. For full evaluation of an integrated sorption collector solar heating and cooling system, under the umbrella of a European Union project for technological innovation, a 180 m2 large-scale demonstration system has been installed in Karlstad, Sweden. Results from the installation commissioned in summer 2014 with non-optimised control strategies showed average electrical COP of 10.6 and average cooling powers between 140 and 250 Wm-2 collector aperture area. Optimisation of control strategies, heat transfer fluid flows through the collectors and electrical COP will be carried out in autumn 2014.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Exploiting solar energy technology for both heating and cooling purposes has the potential of meeting an appreciable portion of the energy demand in buildings throughout the year. By developing an integrated, multi-purpose solar energy system, that can operate all twelve months of the year, a high utilisation factor can be achieved which translates to more economical systems. However, there are still some techno-economic barriers to the general commercialisation and market penetration of such technologies. These are associated with high system and installation costs, significant system complexity, and lack of knowledge of system implementation and expected performance. A sorption heat pump module that can be integrated directly into a solar thermal collector has thus been developed in order to tackle the aforementioned market barriers. This has been designed for the development of cost-effective pre-engineered solar energy system kits that can provide both heating and cooling. This thesis summarises the characterisation studies of the operation of individual sorption modules, sorption module integrated solar collectors and a full solar heating and cooling system employing sorption module integrated collectors. Key performance indicators for the individual sorption modules showed cooling delivery for 6 hours at an average power of 40 W and a temperature lift of 21°C. Upon integration of the sorption modules into a solar collector, measured solar radiation energy to cooling energy conversion efficiencies (solar cooling COP) were between 0.10 and 0.25 with average cooling powers between 90 and 200 W/m2 collector aperture area. Further investigations of the sorption module integrated collectors implementation in a full solar heating and cooling system yielded electrical cooling COP ranging from 1.7 to 12.6 with an average of 10.6 for the test period. Additionally, simulations were performed to determine system energy and cost saving potential for various system sizes over a full year of operation for a 140 m2 single-family dwelling located in Madrid, Spain. Simulations yielded an annual solar fraction of 42% and potential cost savings of €386 per annum for a solar heating and cooling installation employing 20m2 of sorption integrated collectors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of this study were to evaluate morphologic alterations and precancerous lesions in Reinke's edema. Patients included were 54 smokers with bilateral Reinke's edema submitted to surgery in the Otolaryngology Department, Botucatu Medical School, São Paulo State University, Brazil, between 2002 and 2006. All specimens were evaluated by light microscopy and five contralateral lesions were also evaluated by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The main histological alterations were edema (100%), inflammation (81.48%), basal membrane (bm) thickening (77.77%), and vessel proliferation (75.92%). Epithelium alterations were classified as grade 0 (11.11%), grade 1 (70.37%), grade 2 (14.81%), and grade 3 (3.70%). In the case included in grade 3 classification, microinvasive carcinoma was detected. SEM showed epithelial surface with some cellular desquamation, few microridges, and a polished and impermeable surface aspect. TEM showed epithelial hyperplasia, basal cells with different sizes, widening of the intercellular spaces, abnormal desmosome architecture, thickening of the bm, some electron-dense vesicles, and points of interruption. The morphological alterations presented in this study are not specific to Reinke's edema but this lesion can be the site of different grades of dysplasia and carcinoma, justifying the importance of periodic laryngeal endoscopic exams and meticulous histological analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The tegu lizard Tupinambis merianae exhibits an episodic ventilatory pattern when dormant at 17 degrees C but a uniform ventilatory pattern when dormant at 25 degrees C. At 17 degrees C, ventilatory episodes were composed of 1-22 breaths interspaced by non-ventilatory periods lasting 1.8-26min, Dormancy at the higher body temperature was accompanied by higher rates of O-2 consumption and ventilation. The increase in ventilation was due only to increases in breathing frequency with no change observed in tidal volume. The air convection requirement for O-2 did not differ at the two body temperatures. The respiratory quotient was 0.8 at 17 degrees C and 1.0 at 25 degrees C. We found no consistent relationship between expired gas composition and the start/end of the ventilatory period during episodic breathing at 17 degrees C. However, following non-ventilatory periods of increasing duration, there was an increase in the pulmonary O-2 extraction that was not coupled to an equivalent increase in elimination of CO2 from the lungs. None of the changes in the variables studied could alone explain the initiation/termination of episodic ventilation in the tegus, suggesting that breathing episodes are shaped by a complex interaction between many variables. The estimated oxidative cost of breathing in dormant tegus at 17 degrees C was equivalent to 52.3% of the total metabolic rate, indicating that breathing is the most costly activity during dormancy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A herança da resistência ao oídio na cultivar de ervilha MK-10 e alguns aspectos histológicos da infecção foram estudados. Para o estudo da herança, as gerações F1, F2, retrocuzamentos e geração F3 de MK-10 com duas populações suscetíveis foram avaliadas. Nas avaliações histológicas observou-se a porcentagem de conídios germinados, porcentagem de conídios que formaram apressório, porcentagem de conídios que estabeleceram colônia e número de haustórios por colônia. Para comparar as razões de segregação obtidas no estudo da herança da resistência, adotou-se o teste do Qui-quadrado (X²) e para os dados das análises histológicas, utilizou-se o teste Tukey a 5% de probabilidade. Concluiu-se que a resistência de MK-10 ao oídio é devida a um par de alelos recessivos e que a resistência é expressa na fase de pré-penetração, completada por uma morte celular localizada pós-penetração, característica da presença do par de alelos recessivos er1er1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thin films of perovskite-type materials such as PbTiO3, BaTiO3, (Pb,La)TiO3, (Pb, La)(ZrTi)O-3, KNbO3, and Pb(Mg,Nb)03 have been attracting great interest for applications like non-volatile memories, ultrasonic sensors and optical devices. Thin film should be epitaxially grown or at least highly textured since the properties of this anisotropic material depend on the crystallographic orientation. For optical devices, in particular, an epitaxial thin film without defects are essential to reduce optical propagation losses. Pb1-xLaxTiO3 (PLT) where x=0, 13 and 27% thin films were prepared by a chemical method (polymeric precursors method), and deposited by the spin coating technique onto substrates of SrTiO3 (STO) and LaAlO3 (LAO). The films were then beat treated at 500 degrees C in a controlled atmosphere of 0,. The orientation degree of the thin films was obtained from rocking curve technique, by means of X-ray difftaction analysis. A microstructural study revealed that the films were crack-free, homogeneous and have low roughness. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this work was to investigate the viscoelastic properties of aqueous suspensions of crude collagen powder extracted from bovine hides and nonsubmitted to the hydrolysis reaction that leads to gelatin. The studied variables included the collagen concentration and the addition of xanthan gum or maltodextrin at varied concentrations during heating/cooling of the mixtures. Differential scanning calorimetry thermograms showed that the addition of polysaccharides decreased the endothermic peak areas observed at the denaturation temperature of collagen. The rheological properties of the pure collagen suspensions were highly dependent on concentration: 4% and 6% collagen suspensions presented a great increase in the storage modulus after heating/cooling, whereas for concentrations of 8% and 10% G' decreased during heating and did not recover its original value after heating/cooling. The frequency sweeps showed that the thermal treatment was responsible by the strengthening of the interactions that formed the polymer network. Addition of 0.1% xanthan gum to collagen suspensions increased the gel strength, especially after heating/cooling of the system, whereas increasing gum concentration to 0.3% resulted in a weaker gel, which could indicate thermodynamic incompatibility between the biopolymers. Mixtures of collagen and maltodextrin resulted in more fluid structures than those obtained with pure collagen at the same collagen concentration and the range of temperatures in which these mixtures behaved as a gel decreased with increasing concentrations of both collagen and maltodextrin, suggesting incompatibilities between the biopolymers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To compare modes and sources of infection and clinical and biosafety aspects of accidental viral infections in hospital workers and research laboratory staff reported in scientific articles. Methods: PubMed, Google Scholar, ISI Web of Knowledge, Scirus, and Scielo were searched (to December 2008) for reports of accidental viral infections, written in English, Portuguese, Spanish, or German; the authors' personal file of scientific articles and references from the articles retrieved in the initial search were also used. Systematic review was carried out with inclusion criteria of presence of accidental viral infection's cases information, and exclusion criteria of absence of information about the viral etiology, and at least probable mode of infection.Results: One hundred and forty-one scientific articles were obtained, 66 of which were included in the analysis. For arboviruses, 84% of the laboratory infections had aerosol as the source; for alphaviruses alone, aerosol exposure accounted for 94% of accidental infections. of laboratory arboviral infections, 15.7% were acquired percutaneously, whereas 41.6% of hospital infections were percutaneous. For airborne viruses, 81% of the infections occurred in laboratories, with hantavirus the leading causative agent. Aerosol inhalation was implicated in 96% of lymphocytic choriomeningitis virus infections, 99% of hantavirus infections, and 50% of coxsackievirus infections, but infective droplet inhalation was the leading mode of infection for severe acute respiratory syndrome coronavirus and the mucocutaneous mode of infection was involved in the case of infection with influenza B. For blood-borne viruses, 92% of infections occurred in hospitals and 93% of these had percutaneous mode of infection, while among laboratory infections 77% were due to infective aerosol inhalation. Among blood-borne virus infections there were six cases of particular note: three cases of acute hepatitis following hepatitis C virus infection with a short period of incubation, one laboratory case of human immunodeficiency virus infection through aerosol inhalation, one case of hepatitis following hepatitis G virus infection, and one case of fulminant hepatitis with hepatitis B virus infection following exposure of the worker's conjunctiva to hepatitis B virus e antigen-negative patient saliva. of the 12 infections with viruses with preferential mucocutaneous transmission, seven occurred percutaneously, aerosol was implicated as a possible source of infection in two cases, and one atypical infection with Macacine herpesvirus 1 with fatal encephalitis as the outcome occurred through a louse bite. One outbreak of norovirus infection among hospital staff had as its probable mode of infection the ingestion of inocula spread in the environment by fomites.Conclusions: The currently accepted and practiced risk analysis of accidental viral infections based on the conventional dynamics of infection of the etiological agents is insufficient to cope with accidental viral infections in laboratories and to a lesser extent in hospitals, where unconventional modes of infection are less frequently present but still have relevant clinical and potential epidemiological consequences. Unconventional modes of infection, atypical clinical development, or extremely severe cases are frequently present together with high viral loads and high virulence of the agents manipulated in laboratories. In hospitals by contrast, the only possible association of atypical cases is with the individual resistance of the worker. Current standard precaution practices are insufficient to prevent most of the unconventional infections in hospitals analyzed in this study; it is recommended that special attention be given to flaviviruses in these settings. (C) 2011 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mn(II) doped SnO2 thin films used for shielding fluoride glasses against corrosion were investigated by x-ray absorption spectroscopy (EXAFS and XANE)S at the Sn and Mn K-edges. The effect of firing treatment on the densification of the films was studied. It has been evidenced a partial change of Mn valence from 2.3 to 2.6 upon heating which is attributed to a change of ratios of two Mn sites: grafted divalent Mn ions at the surface of SnO 2 nanocrystallites and trivalent Mn ions embedded into a substitutional solid solution with Sn. © Physica Scripta 2005.