978 resultados para Diode array UV spectroscopy
Resumo:
Complexes of polyelectrolytes with defined charge distance and different dendrimer counterions Magdalena Chelmecka Max Planck Institute for Polymer Research; Ackermannweg 10; D-55128 Mainz ; Tel.: (+49) 06131- 379 – 226 A study of complexes in solution is of interest to investigate whether the formation of well-defined assemblies like in classical surfactant systems is possible. Aim of this thesis is to investigate the electrostatic self-assembly of linear polycations of varying charge distance with “large” counterions of varying architecture. We especially investigate the morphology of objects formed, but also their stability under salt free condition and after low molecular mass salt addition. As polycations, Poly(dialkylimino)-alkylene salts (Ionenes) I65MeBr and I25MeBr were chosen. Ionenes are synthesized via Menschutkin reaction and characterized by standard methods. Counterions are Polyamidoamine (PAMAM) dendrimers of generations G2.5, G5.5, G7.5 with -COONa surface groups and shape-persistent, Polyphenylene dendrimers of generation G1 with surface -COOH groups. A complex interplay of interactions is expected to direct the self assembly via electrostatic interaction, geometric factors, hydrophobic interaction or hydrogen bonds. Methods used for the investigation of complexes are: UV-spectroscopy, pH-metric techniques, dynamic and static light scattering, small angle neutron scattering, potential measurements and potentiometric titration. Under certain conditions, (i.e. charge ratio of compounds, charge density of ionene and dendrimer also concentration of sample) polyelectrolyte systems composed of ionenes and dendrimers build complexes in solution. System compounds are typical polyelectrolytes, but structures which they build behave not usual for typical polyelectrolytes. In a one diffusion mode regime aggregates of about 100 nm hydrodynamic radius have been found. Such aggregates are core-shell or anisotropic core shell structures in the case of ionenes/PAMAM dendrimers complexes. These complexes are stable even at high ionic strength. In case of ionenes with poly(phenylene) dendrimers, hard sphere-like objects or spherical objects with hairy-like surface have been found in a one diffusion mode regime. Their stability at high ionic strength is lower. For the ionenes/poly(phenylene) dendrimers systems one transition point has been found from one to two diffusion processes, towards increasing ionene concentration, i.e. for the samples with fixed dendrimer concentration towards increasing ionic strength. For the diffusion profile of ionene/PAMAM dendrimers in most cases two transition regimes are observed. One at very low ionene concentration, the second one at high ionene concentrations, which again means for the samples with fixed dendrimer concentration, also at higher ionic strength. Both two mode regimes are separated by the one mode regime. As was confirmed experimentally, the one diffusion mode regime is caused by the motion of well defined assemblies. The two diffusion mode regimes are caused by the movement of different sized species in solution, large aggregates and middle-size aggregates (oligoaggregates). The location and also the number of transition points in the diffusion profiles is dependent on the ionene to dendrimer charge ratio, charge density of the compounds and concentration. No influence of the molecular mass of the ionene has been found. The aggregates are found to be charged on the surface, however this surface charge does not significantly influence the diffusion properties of the system.
Resumo:
Drug abuse is a major global problem which has a strong impact not only on the single individual but also on the entire society. Among the different strategies that can be used to address this issue an important role is played by identification of abusers and proper medical treatment. This kind of therapy should be carefully monitored in order to discourage improper use of the medication and to tailor the dose according to the specific needs of the patient. Hence, reliable analytical methods are needed to reveal drug intake and to support physicians in the pharmacological management of drug dependence. In the present Ph.D. thesis original analytical methods for the determination of drugs with a potential for abuse and of substances used in the pharmacological treatment of drug addiction are presented. In particular, the work has been focused on the analysis of ketamine, naloxone and long-acting opioids (buprenorphine and methadone), oxycodone, disulfiram and bupropion in human plasma and in dried blood spots. The developed methods are based on the use of high performance liquid chromatography (HPLC) coupled to various kinds of detectors (mass spectrometer, coulometric detector, diode array detector). For biological sample pre-treatment different techniques have been exploited, namely solid phase extraction and microextraction by packed sorbent. All the presented methods have been validated according to official guidelines with good results and some of these have been successfully applied to the therapeutic drug monitoring of patients under treatment for drug abuse.
Resumo:
Synthese und photophysikalische Eigenschaften funktionalisierter 1-Oligoalkinylamide Torsten Schweikert Zusammenfassung der Dissertation zur Erlangung des Grades „Doktor der Naturwissenschaften“ Die Zielsetzung dieser Arbeit bestand aus der Synthese verschiedener 1-Oligoalkinylamide und deren Funktionalisierung mit endständigen Akzeptoreinheiten, um einen Zugang zu konjugierten Donor-Akzeptor-substituierten Acetylenchromophoren zu realisieren, welche die Aminogruppe direkt am Acetylenkohlenstoff tragen. In einer kupfer(I)-katalysierten Cadiot-Chodkiewicz-Reaktion konnten terminale 1-Alkinylamide 1 mit verschiedenen substituierten 1-Bromalkinen 2 zu den 1-Oligoalkinylamiden 3 umgesetzt werden. Die Reaktion zeichnet sich durch eine hohe Toleranz gegenüber verschiedenen funktionellen Gruppen aus und lieferte die 1-Oligoalkinylamide 3 in Ausbeuten von 34 bis 99 %. NR1EWGNR2R1EWGR2Br5 Mol-% CuI30 Mol-% NH2OH·H2O2.0 Äquiv. n-BuNH2MeOH0 °C - 40 °C, 0.5 - 2 h34 - 99 %1.5 Äquiv. 213R1: Phenyl, 2-Iodphenyl, Benzyl, AlkylR2: Alkyl, Hydroxyalkyl, O-Tetrahydropyranyloxyalkyl, Methylester, 4-Nitrophenyl, 4-Cyanophenyl, 4-Dimesitylborylphenylnn Mittels UV/Vis-Spektroskopie sind die verschiedenen Donor-Akzeptor-substituierten Chromophore auf ihre photophysikalischen Eigenschaften hin untersucht worden. Dabei zeigten sich verschiedene Effekte bei Variation der Donor- und Akzeptorgruppen sowie bei Verlängerung der Acetylenbrücke auf die Lage der Charge-Transfer-Bande. Die Solvatochromie der Absorptionsbanden zeigte das Vorhandensein eines permanenten Dipolmoments der Verbindungen. Die elektrooptische Absorptionsmessung konnte schließlich Informationen über die Größe der Dipolmomente im Grundzustand und im angeregten Franck-Condon-Zustand liefern. Die elektrischen Dipolmomente der Verbindungen im Grundzustand in 1,4-Dioxan und Cyclohexan liegen im Bereich von (9.4 – 12.2)10-30 Cm. Nach optischer Anregung erhöhen sich die Dipolmomente um (25.0 – 92.3)10-30 Cm, wobei die Änderung des Dipolmoments bei optischer Anregung ein Maximum für die 1-Diinylamide durchläuft und bei drei konjugierten Acetylenbindungen stark abnimmt. Die synthetisierten 1-Diinylamide fanden ferner Anwendung in der Synthese von funktionalisierten 3-Alkinylindolen, wobei mittels einer palladiumkatalysierten Heteroanellierungssequenz in 2-Position am Indol ein Schwefel- oder Stickstoffnucleophil eingeführt werden konnte.
Resumo:
Applikationsfertige Zytostatikazubereitungen werden heute unter der Verantwortung eines Apothekers in zentralisierten Herstellungsbereichen hergestellt. Weil die Verordnung der Chemotherapie ein großes Fehlerrisiko birgt, ist konsequentes Verordnungsmonitoring ein wesentlicher Teilprozess der zentralen Zytostatikazubereitung. rnDie aktuelle Umsetzung und die Ergebnisse des Verordnungsmonitorings in den Universitätskliniken Deutschlands wurden im Rahmen dieser Arbeit in einer prospektiven Erhebung erfasst. Als häufigste Verordnungsirrtümer wurden Dosisberechnungsfehler (48%), welche als von hoher Relevanz (78%) für die Patientensicherheit angesehen wurden, genannt. Die Inzidenz der Verordnungsfehler betrug durchschnittlich 0,77% bei rund 1950 Verordnungen pro Tag. Das konsequente Verordnungsmonitoring von pharmazeutischer Seite erfolgt höchst effizient und leistet einen hohen Beitrag zur Patienten- und Arzneimitteltherapiesicherheit in der Onkologie.rnFür die Herstellung der applikationsfertiger Zytostatika-Zubereitungen sind fundierte Kenntnisse zu deren physikalisch-chemischen Stabilität erforderlich. Zu neu zugelassenen Zytostatika und insbesondere Biologicals, stehen häufig noch keine Daten zur Stabilität der applikationsfertigen Lösungen zur Verfügung. Die Bestimmung der physikalisch-chemischen Stabilität war daher Gegenstand dieser Arbeit. Die applikationsfertigen Infusionslösungen der Purin-Analoga Nelarabin und Clofarabin (RP-HPLC), sowie des monoklonalen Antiköpers Trastuzumab (SEC, UV-Spektroskopie, SDS-Page), erwiesen sich über einen Zeitraum von mindestens 28 Tagen als stabil. Die Stabilität zweier Camptothecin-Derivate (Topotecan und Irinotecan) beladen auf DC Beads™, wie auch die Ladungskapazität und Kompatibilität mit Kontrastmitteln, wurde ebenfalls bewiesen. rn
Resumo:
Patienten mit Cystischer Fibrose müssen in der Regel verschiedene Arzneimittel mehrmals täglich inhalieren. Um den hohen Zeitaufwand dafür zu reduzieren werden die Arzneimittel häufig gemischt und simultan inhaliert. Die Kenntnis der physikalisch-chemischen Kompatibilität von Mischinhalationslösungen/ -suspensionen ist deshalb von großer Bedeutung. In der vorliegenden Arbeit wurden die Kompatibilitäten von Mischungen aus Colistimethat-Inhalationslösung (mikrobiologische Wertbestimmung) mit verschiedenen Tobramycin-Inhalationslösungen, Budesonid (HPLC) mit 5,85%-iger Natriumchlorid-Lösung sowie mit Colistimethat-Inhalationslösung und Dornase alfa (SE-HPLC, SDS-PAGE, UV-Spektrometrie, T-SCX-Chromatographie) mit verschiedenen Tobramycin-Inhalationslösungen (Fluoreszenzpolarisations-Immunoassay) nachgewiesen. Durch das Mischen mit Tobramycin-Inhalationslösungen wurden die aerodynamischen Eigenschaften (FPF, MMAD, GSD) von Dornase alfa bei simultaner Verneblung nicht verändert (bestimmt mittels Kaskadenimpaktion).rnDurch die physiologischen und anatomischen Gegebenheiten, sowie die kognitiven Fähigkeiten kleiner Kinder stellt die effektive inhalative Therapie eine große Herausforderung dar. Der Respimat® bietet mit seiner langen Sprühdauer und den kleinen Aerosolpartikeln eine vielversprechende Alternative für die Anwendung bei Kleinkindern. In der vorliegenden Studie wurde untersucht ob bei Kindern unter 5 Jahren der Respimat® als Inhalationsgerät verwendet werden kann und welchen Grad an Hilfestellung sie für ein erfolgreiches Inhalationsmanöver benötigen.rnDie Ergebnisse der Handhabungsuntersuchung, sowie die Bewertung aufgezeichneter Inhalationsprofile zeigten, dass der Respimat® für Kinder < 4 Jahre nur in Kombination mit einer Inhalierhilfe wie dem AeroChamber Plus® verwendet werden sollte. Kinder im Alter von 4 Jahren sind mit entsprechender Schulung in der Lage mit dem Respimat® alleine zu inhalieren.rn
Resumo:
This thesis work aims to develop original analytical methods for the determination of drugs with a potential for abuse, for the analysis of substances used in the pharmacological treatment of drug addiction in biological samples and for the monitoring of potentially toxic compounds added to street drugs. In fact reliable analytical techniques can play an important role in this setting. They can be employed to reveal drug intake, allowing the identification of drug users and to assess drug blood levels, assisting physicians in the management of the treatment. Pharmacological therapy needs to be carefully monitored indeed in order to optimize the dose scheduling according to the specific needs of the patient and to discourage improper use of the medication. In particular, different methods have been developed for the detection of gamma-hydroxybutiric acid (GHB), prescribed for the treatment of alcohol addiction, of glucocorticoids, one of the most abused pharmaceutical class to enhance sport performance and of adulterants, pharmacologically active compounds added to illicit drugs for recreational purposes. All the presented methods are based on capillary electrophoresis (CE) and high performance liquid chromatography (HPLC) coupled to various detectors (diode array detector, mass spectrometer). Biological samples pre-treatment was carried out using different extraction techniques, liquid-liquid extraction (LLE) and solid phase extraction (SPE). Different matrices have been considered: human plasma, dried blood spots, human urine, simulated street drugs. These developed analytical methods are individually described and discussed in this thesis work.
Resumo:
The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).
Resumo:
Carbon dioxide (CO2) has been of recent interest due to the issue of greenhouse cooling in the upper atmosphere by species such as CO2 and NO. In the Earth’s upper atmosphere, between altitudes of 75 and 110 km, a collisional energy exchange occurs between CO2 and atomic oxygen, which promotes a population of ground state CO2 to the bend excited state. The relaxation of CO2 following this excitation is characterized by spontaneous emission of 15-μm. Most of this energy is emitted away from Earth. Due to the low density in the upper atmosphere, most of this energy is not reabsorbed and thus escapes into space, leading to a local cooling effect in the upper atmosphere. To determine the efficiency of the CO2- O atom collisional energy exchange, transient diode laser absorption spectroscopy was used to monitor the population of the first vibrationally excited state, 13CO2(0110) or ν2, as a function of time. The rate coefficient, kO(ν2), for the vibrational relaxation 13CO2 (ν2)-O was determined by fitting laboratory measurements using a home-written linear least squares algorithm. The rate coefficient, kO(ν2), of the vibrational relaxation of 13CO2(ν2), by atomic oxygen at room temperature was determined to be (1.6 ± 0.3 x 10-12 cm3 s-1), which is within the uncertainty of the rate coefficient previously found in this group for 12CO2(ν2) relaxation. The cold temperature kO(ν2) values were determined to be: (2.1 ± 0.8) x 10-12 cm3 s-1 at Tfinal = 274 K, (1.8 ± 0.3) x 10-12 cm3 s-1 at Tfinal = 239 K, (2 ± 1) x 10-12 cm3 s-1 at Tfinal = 208 K, and (1.7 ± 0.3) x 10-12 cm3 s-1 at Tfinal = 186 K. These data did not show a definitive negative temperature dependence comparable to that found for 12CO2 previously.
Resumo:
Transient Diode Laser Absorption Spectroscopy (TDLAS) was used to perform vibrational state population studies of the CO2 product from the hyperthermal reaction between C2H4 and O(3P) at room temperature using O3 as the O-atom precursor. Photodissociation of O3 using a frequency quadrupled Q-switch Nd:YAG laser pulse at 266 nm produced O(3P) atoms at high velocities which subsequently reacted with C2H4, producing several primary and secondary products including CO2. The CO2 product was detected using high-resolution TDLAS under five unique sets of reaction conditions. The vibrational distribution of the CO2 product did not follow a Boltzmann distribution at all five sets of conditions. The experiments showed a distribution in which there was a surprisingly high population in the (1000) (symmetric stretching) state compared with the other states probed, all of which contained bend excitation. In general, the CO2 population in the (1000) state was about 15-20% more populated than the Boltzmann distribution predicts. A possible explanation for this result may lie in the mechanism of CO2 evolution from the C2H4 + O(3P) reaction.
Resumo:
Laboratory measurements of the rate coefficient for quenching of O3(nu2) by ground-state atomic oxygen, kO(nu2), at room temperature are presented. kO(nu2) is currently not well known and is necessary for appropriate nonlocal thermodynamic equilibrium modeling of the upper mesosphere and lower thermosphere. In this work, a 266 nm laser pulse photolyzes a small amount of O3 in a slow-flowing gas mixture of O3, Xe, and Ar. This process simultaneously produces atomic oxygen and increases the temperature of the gas mixture slightly, thereby increasing the population in the O3(nu2) state. Transient diode laser absorption spectroscopy is used to monitor the populations of the O3(nu2) and ground vibrational states as the system re-equilibrates. Relaxation rates are measured over a range of quencher concentrations to extract the rate coefficient of interest. The value of kO(nu2) was determined to be (2.2 0.5) * 10(-12) cm(3) s(-1).
Resumo:
An HPLC-DAD method for the quantitative analysis of Δ(9)-tetrahydrocannabinol (THC), Δ(9)-tetrahydrocannabinolic acid-A (THCA-A), cannabidiol (CBD), and cannabinol (CBN) in confiscated cannabis products has been developed, fully validated and applied to analyse seized cannabis products. For determination of the THC content of plant material, this method combines quantitation of THCA-A, which is the inactive precursor of THC, and free THC. Plant material was dried, homogenized and extracted with methanol by ultrasonication. Chromatographic separation was achieved with a Waters Alliance 2695 HPLC equipped with a Merck LiChrospher 60 RP-Select B (5μm) precolumn and a Merck LiChroCart 125-4 LiChrospher 60 RP-Select B (5μm) analytical column. Analytes were detected and quantified using a Waters 2996 photo diode array detector. This method has been accepted by the public authorities of Switzerland (Bundesamt für Gesundheit, Federal Office of Public Health), and has been used to analyse 9092 samples since 2000. Since no thermal decarboxylation of THCA-A occurs, the method is highly reproducible for different cannabis materials. Two calibration ranges are used, a lower one for THC, CBN and CBD, and a higher one for THCA-A, due to its dominant presence in fresh plant material. As provider of the Swiss proficiency test, the robustness of this method has been tested over several years, and homogeneity tests even in the low calibration range (1%) show high precision (RSD≤4.3%, except CBD) and accuracy (bias≤4.1%, except CBN).
Resumo:
To ensure the integrity of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard among clinical institutions, and many devices and action levels are used. Since the acceptance criteria determines if the dosimetric tools’ output passes the patient plan, it is important to see how these parameters influence the performance of the QA device. While analyzing the results of IMRT QA, it is important to understand the variability in the measurements. Due to the different form factors of the many QA methods, this reproducibility can be device dependent. These questions of patient-specific IMRT QA reproducibility and performance were investigated across five dosimeter systems: a helical diode array, radiographic film, ion chamber, diode array (AP field-by-field, AP composite, and rotational composite), and an in-house designed multiple ion chamber phantom. The reproducibility was gauged for each device by comparing the coefficients of variation (CV) across six patient plans. The performance of each device was determined by comparing each one’s ability to accurately label a plan as acceptable or unacceptable compared to a gold standard. All methods demonstrated a CV of less than 4%. Film proved to have the highest variability in QA measurement, likely due to the high level of user involvement in the readout and analysis. This is further shown by how the setup contributed more variation than the readout and analysis for all of the methods, except film. When evaluated for ability to correctly label acceptable and unacceptable plans, two distinct performance groups emerged with the helical diode array, AP composite diode array, film, and ion chamber in the better group; and the rotational composite and AP field-by-field diode array in the poorer group. Additionally, optimal threshold cutoffs were determined for each of the dosimetry systems. These findings, combined with practical considerations for factors such as labor and cost, can aid a clinic in its choice of an effective and safe patient-specific IMRT QA implementation.
Resumo:
Introdução: Diante das mudanças nos hábitos de consumo alimentar da população brasileira, suplementos vitamínicos e alimentos enriquecidos são veículos comumente empregados para atender as necessidades de ingestão de micronutrientes. A diversidade de suplementos vitamínicos comercializados atualmente leva à necessidade de desenvolvimento de métodos analíticos de fácil execução e alta produtividade. Informações confiáveis sobre os teores de vitaminas poderão ser obtidas somente com métodos analíticos validados. Objetivos: Validar metodologias analíticas e avaliar o teor de vitaminas antioxidantes em suplementos adquiridos no comércio do município de São Paulo - Brasil, o efeito do armazenamento nestes compostos e confrontar os valores analisados com os valores declarados na rotulagem. Métodos: As metodologias analíticas para determinação de vitaminas antioxidantes por cromatografia líquida de alta eficiência com detector de arranjo de diodos (CLAE-DAD) e de vitamina C por titulação potenciométrica foram validadas para as matrizes sólidas, oleosas e líquidas de suplementos vitamínicos. A estabilidade das vitaminas foi avaliada a cada 6 meses durante 12 meses de armazenamento e a avaliação da rotulagem foi realizada de acordo com as legislações vigentes no Brasil. Resultados: Para os métodos cromatográficos, os limites de detecção (LDs) e de quantificação (LQs) variaram entre 0,3 e 4,3 µg/mL, e entre 0,5 e 14,0 µg/mL respectivamente. As recuperações dos padrões adicionados nas matrizes variaram entre 92 por cento e 109 por cento e entre 86 por cento e 108 por cento no material de referência. A repetitividade foi calculada pelo desvio padrão relativo (RSD), apresentando valores entre 0,2 por cento e 9,6 por cento . Para a determinação de vitamina C pelo método potenciométrico, o LD e o LQ foram respectivamente 1 mg e 3 mg; a recuperação no material de referência foi de 99,8 por cento e a precisão variou entre 0,4 e 3,9 por cento . Das 57 amostras avaliadas, 59 por cento e 35 por cento apresentaram teores de vitaminas A e E respectivamente, abaixo dos valores declarados no rótulo; por outro lado, 20 por cento das amostras apresentaram teores de vitamina E acima dos valores declarados. Em relação aos teores de vitamina C, 60 por cento das amostras estavam de acordo com os valores declarados. O estudo da estabilidade demonstrou degradação significativa das vitaminas A, E e C em aproximadamente 90 por cento das amostras com 12 meses de armazenamento. Na avaliação da rotulagem dos suplementos vitamínicos, 47 das amostras apresentaram uma ou mais irregularidades. Conclusão: Os métodos propostos se mostraram adequados para análise de diferentes matrizes de suplementos vitamínicos. Os resultados das análises de vitaminas nestes produtos mostraram a necessidade urgente de monitoramento em conjunto com ações de fiscalização, pois verificou-se que a maioria das amostras não atenderam a legislação, principalmente quanto aos teores declarados na informação nutricional da rotulagem. A sobredosagem de vitaminas pode ser necessária para manter os teores declarados durante o armazenamento, porém, a quantidade adicional de vitamina a ser incluída no suplemento deve estar dentro de limites seguros e depende de cada amostra, pois além da matriz, diversos fatores relacionados aos compostos e à embalagem também podem influenciar na estabilidade das vitaminas.
Resumo:
Tetrazolo[1,5-a] quinazoline (9) is converted to 2-azidoquinazoline (10) on sublimation at 200 degrees C and above, and the azide-tetrazole equilibrium is governed by entropy. 2-Quinazolylnitrenes 11 and 27 and/ or their ring expansion products 14 and 29 can undergo type I (ylidic) and type II (diradicaloid) ring opening. Argon matrix photolysis of 9/10 affords 2-quinazolylnitrene (11), which has been characterized by ESR, UV, and IR spectroscopy. A minor amount of a second nitrene, formed by rearrangement or ring opening, is also observed. A diradical (19) is formed rapidly by type II ring opening and characterized by ESR spectroscopy; it decays thermally at 15 K with a half-life of ca. 47 min, in agreement with its calculated facile intersystem crossing (19T -> 19OSS) followed by facile cyclization/rearrangement to 1-cyanoindazole (21) (calculated activation barrier 1- 2 kcal/mol) and N-cyanoanthranilonitrile (22). 21 and 22 are the isolated end products of photolysis. 21 is also the end product of flash vacuum thermolysis. An excellent linear correlation between the zero-field splitting parameter D (cm(-1)) and the spin density F on the nitrene N calculated at the B3LYP/EPRIII level is reported (R-2 = 0.993 for over 100 nitrenes). Matrix photolysis of 3-phenyltetrazolo[1,5-a] quinazoline (25) affords the benzotriazacycloheptatetraene 29, which can be photochemically interconverted with the type I ring opening product 2-isocyano-alpha-diazo-alpha- phenyltoluene (33) as determined by IR and UV spectroscopy. The corresponding carbene 37, obtained by photolysis of 33, was detected by matrix ESR spectroscopy.
Resumo:
Alpha-fetoprotein (AFP) is a commercially important polypeptide with important diagnostic. physiological and immunomodulatory functions. Previous studies into the refolding of this macromolecule are contradictory. and variously suggest that AFP denaturation may be irreversible or that refolding may be achieved by reducing denaturant concentration through dilution but not dialysis. Importantly, these same previous studies do not provide quantitative metrics by which the Success of refolding, and the potential for bioprocess development. can be assessed. Moreover, these same studies do not optimize and control refolding redox potential - an important factor considering that AFP contains 32 cysteines which form 16 disulfide bonds. In this current study, a quantitative comparison of recombinant human AFP (rhAFP) refolding by dilution and dialysis is conducted under optimized redox conditions. rhAFP refolding yields were > 35% (dialysis refolding) and > 75% (dilution refolding) as assessed by RP-HPLC and ELISA, with structural Similarity to the native state confirmed by UV spectroscopy. Dialysis refolding yield was believed to be lower because the gradual reduction in denaturant concentration allowed extended conformational searching. enabling more time for undesirable interaction with other protein molecules and/or the dialysis membrane, leading to a Sub-optimal process outcome. Significant yield sensitivity to redox environment was also observed, emphasizing the importance of physicochemical optimization. This study demonstrates that very high refolding yields can be obtained, for a physiologically relevant protein, with optimized dilution refolding. The study also highlights the quantitative metrics and macromolecular physical spectroscopic 'fingerprints' required to facilitate transition from laboratory to process scale.