983 resultados para Diagnostic-tests


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. Laboratory utilization has steadily increased with a corresponding increase in overall costs; several authors have attempted to measure the impact of inappropriateness on clinical outcomes but data are insufficient. The aim of the study is to assess the cost of inappropriateness of test-ordering behaviour for second-level coagulation tests (hemorrhagic diathesisand thrombophilia). Methods. We reviewed all second-level coagulation testrequests received by our department during a six months period. Clinicians must fill out a specific order form for these kind of tests, containing all informations deemed necessary for the laboratory specialist to evaluatethe appropriateness of the request. We identified all inappropriate requests and counted the numbers and types of all coagulation tests that were not performed during the period. An analysis of the laboratory activity costs was done in order to calculate the global costof each test in our department and to estimate the savings achieved. Results. On a total of 1664 second-level coagulationtest requests, we estimated 150 as completely inappropriate. We found an overall of 295 inappropriate testswhich were not performed. This resulted in an economic saving of 20.000 euro in 6 months. Conclusions. The analysis of cost of our intervention shows the urgent need for a definite and sustained reduction in inappropriate requests of second-level coagulation tests. Even though we estimated only the economic aspect of inappropriate testing, this is also associated with the overuse of diagnostic tests which entailsthe risk of generating erroneous results with potentialnegative consequences on patients' health.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The vulnerability of subpopulations of retinal neurons delineated by their content of cytoskeletal or calcium-binding proteins was evaluated in the retinas of cynomolgus monkeys in which glaucoma was produced with an argon laser. We quantitatively compared the number of neurons containing either neurofilament (NF) protein, parvalbumin, calbindin or calretinin immunoreactivity in central and peripheral portions of the nasal and temporal quadrants of the retina from glaucomatous and fellow non-glaucomatous eyes. There was no significant difference between the proportion of amacrine, horizontal and bipolar cells labeled with antibodies to the calcium-binding proteins comparing the two eyes. NF triplet immunoreactivity was present in a subpopulation of retinal ganglion cells, many of which, but not all, likely correspond to large ganglion cells that subserve the magnocellular visual pathway. Loss of NF protein-containing retinal ganglion cells was widespread throughout the central (59-77% loss) and peripheral (96-97%) nasal and temporal quadrants and was associated with the loss of NF-immunoreactive optic nerve fibers in the glaucomatous eyes. Comparison of counts of NF-immunoreactive neurons with total cell loss evaluated by Nissl staining indicated that NF protein-immunoreactive cells represent a large proportion of the cells that degenerate in the glaucomatous eyes, particularly in the peripheral regions of the retina. Such data may be useful in determining the cellular basis for sensitivity to this pathologic process and may also be helpful in the design of diagnostic tests that may be sensitive to the loss of the subset of NF-immunoreactive ganglion cells.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In most pathology laboratories worldwide, formalin-fixed paraffin embedded (FFPE) samples are the only tissue specimens available for routine diagnostics. Although commercial kits for diagnostic molecular pathology testing are becoming available, most of the current diagnostic tests are laboratory-based assays. Thus, there is a need for standardized procedures in molecular pathology, starting from the extraction of nucleic acids. To evaluate the current methods for extracting nucleic acids from FFPE tissues, 13 European laboratories, participating to the European FP6 program IMPACTS (www.impactsnetwork.eu), isolated nucleic acids from four diagnostic FFPE tissues using their routine methods, followed by quality assessment. The DNA-extraction protocols ranged from homemade protocols to commercial kits. Except for one homemade protocol, the majority gave comparable results in terms of the quality of the extracted DNA measured by the ability to amplify differently sized control gene fragments by PCR. For array-applications or tests that require an accurately determined DNA-input, we recommend using silica based adsorption columns for DNA recovery. For RNA extractions, the best results were obtained using chromatography column based commercial kits, which resulted in the highest quantity and best assayable RNA. Quality testing using RT-PCR gave successful amplification of 200 bp-250 bp PCR products from most tested tissues. Modifications of the proteinase-K digestion time led to better results, even when commercial kits were applied. The results of the study emphasize the need for quality control of the nucleic acid extracts with standardised methods to prevent false negative results and to allow data comparison among different diagnostic laboratories.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Education and diagnostic tests capable of early detection represent our most effective means of preventing transmission of human immunodeficiency virus (HIV). The importance of early detection is underlined by studies demonstrating increased life expectancy following early initiation of antiviral treatment. The Elecsys(®) HIV combi PT assay is a fourth-generation antigen-antibody combination assay developed to allow earlier detection of seroconversion, and to have increased sensitivity and improved specificity. We aimed to determine how early the assay could detect infection compared with existing assays; whether all HIV variants could be detected; and the assay's specificity using samples from blood donors, routine specimens, and patients with potential cross-reacting factors. Samples were identified as positive by the Elecsys(®) assay 4.9 days after a positive polymerase chain reaction result (as determined by the panel supplier), which was earlier than the 5.3-7.1 days observed with comparators. The analytical sensitivity of the Elecsys(®) HIV combi PT assay for the HIV-1 p24 antigen was 1.05 IU/mL, which compares favorably with the comparator assays. In addition, the Elecsys(®) assay identified all screened HIV subtypes and displayed greater sensitivity to HIV-2 homologous antigen and antibodies to HIV-1 E and O and HIV-2 than the other assays. Overall, the specificity of the Elecsys(®) assay was 99.88 % using samples from blood donors and 99.81 % when analyzing unselected samples. Potential cross-reacting factors did not interfere with assay performance. The Elecsys(®) HIV combi PT assay is a sensitive and specific assay that has been granted the CE mark according to Directive 2009/886/EC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To extract and to validate a brief version of the DISCERN which could identify mental health-related websites with good content quality. METHOD: The present study is based on the analysis of data issued from six previous studies which used DISCERN and a standardized tool for the evaluation of content quality (evidence-based health information) of 388 mental health-related websites. After extracting the Brief DISCERN, several psychometric properties (content validity through a Factor analysis, internal consistency by the Cronbach's alpha index, predictive validity through the diagnostic tests, concurrent validity by the strength of association between the Brief DISCERN and the original DISCERN scores) were investigated to ascertain its general applicability. RESULTS: A Brief DISCERN composed of two factors and six items was extracted from the original 16 items version of the DISCERN. Cronbach's alpha coefficients were more than acceptable for the complete questionnaire (alpha=0.74) and for the two distinct domains: treatments information (alpha=0.87) and reliability (alpha=0.83). Sensibility and specificity of the Brief DISCERN cut-off score > or =16 in the detection of good content quality websites were 0.357 and 0.945, respectively. Its predictive positive and negative values were 0.98 and 0.83, respectively. A statistically significant linear correlation was found between the total scores of the Brief DISCERN and those of the original DISCERN (r=0.84 and p<0.0005). CONCLUSION: The Brief DISCERN seems to be a reliable and valid instrument able to discriminate between websites with good and poor content quality. PRACTICE IMPLICATIONS: The Brief DISCERN is a simple tool which could facilitate the identification of good information on the web by patients and general consumers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: In haemodynamically stable patients with acute symptomatic pulmonary embolism (PE), studies have not evaluated the usefulness of combining the measurement of cardiac troponin, transthoracic echocardiogram (TTE), and lower extremity complete compression ultrasound (CCUS) testing for predicting the risk of PE-related death. Methods: The study assessed the ability of three diagnostic tests (cardiac troponin I (cTnI), echocardiogram, and CCUS) to prognosticate the primary outcome of PE-related mortality during 30 days of follow-up after a diagnosis of PE by objective testing. Results: Of 591 normotensive patients diagnosed with PE, the primary outcome occurred in 37 patients (6.3%; 95% CI 4.3% to 8.2%). Patients with right ventricular dysfunction (RVD) by TTE and concomitant deep vein thrombosis (DVT) by CCUS had a PE-related mortality of 19.6%, compared with 17.1% of patients with elevated cTnI and concomitant DVT and 15.2% of patients with elevated cTnI and RVD. The use of any two-test strategy had a higher specificity and positive predictive value compared with the use of any test by itself. A combined three-test strategy did not further improve prognostication. For a subgroup analysis of high-risk patients, according to the pulmonary embolism severity index (classes IV and V), positive predictive values of the two-test strategies for PE-related mortality were 25.0%, 24.4% and 20.7%, respectively. Conclusions: In haemodynamically stable patients with acute symptomatic PE, a combination of echocardiography (or troponin testing) and CCUS improved prognostication compared with the use of any test by itself for the identification of those at high risk of PE-related death.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Urinary indices are classically believed to allow differentiation of transient (or pre-renal) acute kidney injury (AKI) from persistent (or acute tubular necrosis) AKI. However, the data validating urinalysis in critically ill patients are weak. In the previous issue of Critical Care, Pons and colleagues demonstrate in a multicenter observational study that sodium and urea excretion fractions as well as urinary over plasma ratios performed poorly as diagnostic tests to separate such entities. This study confirms the limited diagnostic and prognostic ability of urine testing. Together with other studies, this study raises more fundamental questions about the value, meaning and pathophysiologic validity of the pre-renal AKI paradigm and suggests that AKI (like all other forms of organ injury) is a continuum of injury that cannot be neatly divided into functional (pre-renal or transient) or structural (acute tubular necrosis or persistent).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: As the incidence of malaria diminishes, a better understanding of nonmalarial fever is important for effective management of illness in children. In this study, we explored the spectrum of causes of fever in African children. METHODS: We recruited children younger than 10 years of age with a temperature of 38°C or higher at two outpatient clinics--one rural and one urban--in Tanzania. Medical histories were obtained and clinical examinations conducted by means of systematic procedures. Blood and nasopharyngeal specimens were collected to perform rapid diagnostic tests, serologic tests, culture, and molecular tests for potential pathogens causing acute fever. Final diagnoses were determined with the use of algorithms and a set of prespecified criteria. RESULTS: Analyses of data derived from clinical presentation and from 25,743 laboratory investigations yielded 1232 diagnoses. Of 1005 children (22.6% of whom had multiple diagnoses), 62.2% had an acute respiratory infection; 5.0% of these infections were radiologically confirmed pneumonia. A systemic bacterial, viral, or parasitic infection other than malaria or typhoid fever was found in 13.3% of children, nasopharyngeal viral infection (without respiratory symptoms or signs) in 11.9%, malaria in 10.5%, gastroenteritis in 10.3%, urinary tract infection in 5.9%, typhoid fever in 3.7%, skin or mucosal infection in 1.5%, and meningitis in 0.2%. The cause of fever was undetermined in 3.2% of the children. A total of 70.5% of the children had viral disease, 22.0% had bacterial disease, and 10.9% had parasitic disease. CONCLUSIONS: These results provide a description of the numerous causes of fever in African children in two representative settings. Evidence of a viral process was found more commonly than evidence of a bacterial or parasitic process. (Funded by the Swiss National Science Foundation and others.).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Community-acquired pneumonia (CAP) is a major cause of death in developing countries and of morbidity in developed countries. The objective of the study was to define the causative agents among children hospitalized for CAP defined by WHO guidelines and to correlate etiology with clinical severity and surrogate markers. Investigations included an extensive etiological workup. A potential causative agent was detected in 86% of the 99 enrolled patients, with evidence of bacterial (53%), viral (67%), and mixed (33%) infections. Streptococcus pneumoniae was accounted for in 46% of CAP. Dehydration was the only clinical sign associated with bacterial pneumonia. CRP and PCT were significantly higher in bacterial infections. Increasing the number of diagnostic tests identifies potential causes of CAP in up to 86% of children, indicating a high prevalence of viruses and frequent co-infections. The high proportion of pneumococcal infections re-emphasizes the importance of pneumococcal immunization.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To identify a distinctive chronic visual complication of lysergic acid diethylamide (LSD) use. DESIGN: Description of the clinical findings in three patients with this disorder. SETTING: A neuro-ophthalmology referral center. RESULTS: All three patients experienced prolonged afterimages (palinopsia) during LSD intoxication and have continued to be symptomatic up to 3 years after they ceased to ingest the drug. Results of neuro-ophthalmologic and neurologic examinations and neuroimaging and electrophysiologic studies were normal. CONCLUSIONS: We have described three patients in whom persistent palinopsia developed following ingestion of LSD. Clinicians should inquire about past LSD use in all patients who initially have seemingly spontaneous, isolated palinopsia. Recognition of this distinctive clinical syndrome associated with LSD use might avoid unnecessary anxiety and excessive diagnostic tests for patients with this disorder.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent construction of new generation power plants burning western coal within Iowa has resulted in fly Ash production on the order of 760,000 tons annually. Although fly ash has long been accepted as a valuable replacement for portland cement in concrete, most experience has been with fly ash generated from eastern bituminous coals. A few years ago, fly ash in Iowa was not a significant factor because production was small and economics dictated disposal as the better alternative than construction use. Today, the economic climate, coupled with abundance of the material, makes constructive use in concrete feasible. The problem is, however, fly ash produced from new power plants is different than that for which information was available. It seems fly ash types have outgrown existing standards. The objective of this study was to develop fundamental information about fly ashes available to construction in Iowa such that its advantages and limitations as replacement to portland cement can be defined. Evaluative techniques used in this work involve sophisticated laboratory equipment, not readily available to potential fly ash users, so a second goal was preliminary development of rapid diagnostic tests founded on fundamental information. Lastly, Iowa Department of Transportation research indicated an interesting interdependency among coarse aggregate type, fly ash and concrete's resistance to freeze-thaw action. Thus a third charge of this research project was to verify and determine the cause for the phenomena. One objective of this project was to determine properties of Iowa fly ashes and evaluate their relevance to use of the material as an admixture of PCC. This phase of the research involved two approaches. The first involved the development of a rapid method for determining quantitative elemental composition while the second was aimed at both qualitative and quantitative determination of compounds. X-ray fluorescence techniques were adapted for rapid determination of elemental composition of fly ash. The analysis was performed using a Siemens SR-200 sequential x-ray spectrometer controlled by a PDP-11-03 microcomputer. The spectrometer was equipped with a ten sample specimen chamber and four interchangeable analyzing crystals. Unfiltered excitation radiation was generated using a chromium tube at 50 KV and 48 ma. Programs for the spectrometer were developed by the Siemens Corporation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Although prosthetic joint infection (PJI) is a rare event after arthroplasty, it represents a significant complication that is associated with high morbidity, need for complex treatment, and substantial healthcare costs. An accurate and rapid diagnosis of PJI is crucial for treatment success. Current diagnostic methods in PJI are insufficient with 10-30% false-negative cultures. Consequently, there is a need for research and development into new methods aimed at improving diagnostic accuracy and speed of detection. In this article, we review available conventional diagnostic methods for the diagnosis of PJI (laboratory markers, histopathology, synovial fluid and periprosthetic tissue cultures), new diagnostic methods (sonication of implants, specific and multiplex PCR, mass spectrometry) and innovative techniques under development (new laboratory markers, microcalorimetry, electrical method, reverse transcription [RT]-PCR, fluorescence in situ hybridization [FISH], biofilm microscopy, microarray identification, and serological tests). The results of highly sensitive diagnostic techniques with unknown specificity should be interpreted with caution. The organism identified by a new method may represent a real pathogen that was unrecognized by conventional diagnostic methods or contamination during specimen sampling, transportation, or processing. For accurate interpretation, additional studies are needed, which would evaluate the long-term outcome (usually >2 years) with or without antimicrobial treatment. It is expected that new rapid, accurate, and fully automatic diagnostic tests will be developed soon.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of preoperative assessment is to evaluate the patient's health status, to address known or unidentified co-morbidities and to perform adequate complementary exams if necessary. On the other hand, it allows to prepare and protect the patient in order to reduce perioperative risk. The assessment consists of patient's history and physical examination, both focusing on cardiovascular and respiratory assessment. Complementary exams have to be chosen selectively depending on the patient's risk factors and the type of surgery. They are indicated if their result leads to a potential patient's benefit only, either by a modification in anesthetic and/or surgical management or by introduction of a pharmacological strategy, adequate and maximal if necessary, especially for cardioprotection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tuberculosis is unique among the major infectious diseases in that it lacks accurate rapid point-of-care diagnostic tests. Failure to control the spread of tuberculosis is largely due to our inability to detect and treat all infectious cases of pulmonary tuberculosis in a timely fashion, allowing continued Mycobacterium tuberculosis transmission within communities. Currently recommended gold-standard diagnostic tests for tuberculosis are laboratory based, and multiple investigations may be necessary over a period of weeks or months before a diagnosis is made. Several new diagnostic tests have recently become available for detecting active tuberculosis disease, screening for latent M. tuberculosis infection, and identifying drug-resistant strains of M. tuberculosis. However, progress toward a robust point-of-care test has been limited, and novel biomarker discovery remains challenging. In the absence of effective prevention strategies, high rates of early case detection and subsequent cure are required for global tuberculosis control. Early case detection is dependent on test accuracy, accessibility, cost, and complexity, but also depends on the political will and funder investment to deliver optimal, sustainable care to those worst affected by the tuberculosis and human immunodeficiency virus epidemics. This review highlights unanswered questions, challenges, recent advances, unresolved operational and technical issues, needs, and opportunities related to tuberculosis diagnostics.