948 resultados para Determinação da concentração


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eutrophication is a growing process present in the water sources located in the northeast of Brazil. Among the main consequences of these changes in trophic levels of a water source, stands out adding complexity to the treatment to achieve water standards. By these considerations, this study aimed to define, on a laboratory scale, products and operational conditions to be applied in the processing steps using raw water from Gargalheiras dam, RN, Brazil. The dam mentioned shows a high number of cyanobacteria, with a concentration of cells / ml higher than that established by Decree No. 518/04 MS. The same source was also considered by the state environmental agency in 2009 as hypereutrophic. The static tests developed in this research simulated direct filtration (laboratory filters) and pre-oxidation with chlorine and powdered activated carbon adsorption. The research included the evaluation of the coagulants aluminum hydrochloride (HCA) and alum (SA). The development of the research investigated the conditions for rapid mixing, the dosages of coagulants and pHs of coagulation by the drawing of diagrams. The interference of filtration rate and particle size of filtering means were evaluated as samples and the time of contact were tested with chlorine and activated carbon. By the results of the characterization of the raw water source it was possible to identify the presence of a high pH (7.34). The true color was significant (29 uH) in relation to the apparent color and turbidity (66 uH and 13.60 NTU), reflecting in the measurement of organic matter: MON (8.41 mg.L-1) and Abs254 (0.065 cm-1). The optimization of quick mix set time of 17", the speed gradient of 700 s-1 in the coagulation with HCA and the time of 20" with speed gradient of 800 s-1 for SA. The smaller particle sizes of sand filtering means helped the treatment and the variation in filtration rate did not affect significantly the efficiency of the process. The evaluation of the processing steps found adjustment in standard color and turbidity of the Decree nº 518/04 MS, taking in consideration the average values found in raw water. In the treatment using the HCA for direct filtration the palatable pattern based on the apparent color can be achieved with a dose of 25 mg L-1. With the addition of pre-oxidation step, the standard result was achieved with a reduced dose for 12 mgHCA.L-1. The turbidity standard for water was obtained by direct filtration when the dose exceeds 25 mg L-1 of HCA. With pre-oxidation step there is the possibility of reducing the dose to 20 mg L-1.The addition of CAP adsorption, promoted drinking water for both parameters, with even lower dosage, 13 mg L-1 of HCA. With coagulation using SA removal required for the parameter of apparent color it was achieved with pre-oxidation and 22 mgSA.L-1. Despite the satisfactory results of treatment with the alum, it was not possible to provide water with turbidity less than 1.00 NTU even with the use of all stages of treatment

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A percepção subjetiva de esforço (PSE) é determinada de forma não invasiva e utilizada juntamente com a resposta lactacidêmica como indicadores de intensidade durante teste incremental. em campo, especialmente na natação, há dificuldades nas coletas sanguíneas; por isso, utilizam-se protocolos alternativos para estimar o limiar anaeróbio. Assim, os objetivos do estudo foram: prescrever um teste incremental baseado na PSE (Borg 6-20) visando estimar os limiares metabólicos determinados por métodos lactacidêmicos [ajuste bi-segmentado (V LL), concentração fixa-3,5mM (V3,5mM) e distância máxima (V Dmáx)]; relacionar a PSE atribuída em cada estágio com a freqüência cardíaca (FC) e com parâmetros mecânicos de nado [freqüência (FB) e amplitude de braçada (AB)], analisar a utilização da escala 6-20 na regularidade do incremento das velocidades no teste e correlacionar os limiares metabólicos com a velocidade crítica (VC). Para isso, 12 nadadores (16,4 ± 1,3 anos) realizaram dois esforços máximos (200 e 400m); os dados foram utilizados para determinar a VC, velocidade de 400m (V400m) e a freqüência crítica de braçada (FCb); e um teste incremental com intensidade inicial baseada na PSE, respectivamente, 9, 11, 13, 15 e 17; sendo monitorados em todos os estágios a FC, lactacidêmia e os tempos de quatro ciclos de braçadas e das distâncias de 20m (parte central da piscina) e 50m. Posteriormente, foram calculadas as velocidades dos estágios, FB, AB, V LL, V3,5mM e V Dmáx. Utilizaram-se ANOVA e correlação de Pearson para análise dos resultados. Não foram encontradas diferenças entre VC, V Dmáx e V LL, porém a V3,5mM foi inferior às demais velocidades (P < 0,05). Correlações significativas (P < 0,05) foram observadas entre VC versus V400m, V Dmáx e V3,5mM; V400m versus V3,5mM e V Dmáx; V Dmáx versus V LL; e no teste incremental entre PSE versus velocidade, [Lac], FC, FB e AB (P < 0,05). Concluímos que a PSE é uma ferramenta confiável no controle da velocidade dos estágios durante teste incremental na natação.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Propõe-se metodologia analítica para a determinação da demanda química de oxigênio(DQO) em águas e efluentes pouco poluídos, pela espectrofotometria simultânea dos íons crômio(III) e dicromato, após a clássica oxidação sulfocrômica das amostras, à quente e catalisada por íons Ag+. Demonstra-se que a inter-relação entre as concentrações de DQO, de crômio(III) formado e de dicromato residual permite simplificar a resolução numérica do sistema - de multicomponente, envolvendo as concentrações desses dois íons, e medidas de absorbância em pelo menos dois comprimentos de onda para monocomponente, envolvendo diretamente a concentração em DQO, e medida de absorbância num único comprimento de onda.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to access the P-t(Lim) model in swimming, applying the load control available in full tethered swim condition. Its physiological meaning for the determination of boundary of heavy/severe domains was assessed from the relationships with critical velocity (CV), critical power (CP) and maximal lactate steady state (MLSS). The velocity at MLSS (v(MLSS) = 1.17 +/- 0.11 m/s) and CV (1.19 +/- 0.12 m/s) were significantly different. Similarly, the power at MLSS (p(MFEL) = 89.2 +/- 15.1 W) and CP (99.4 +/- 22.9 W) were significantly different. There was no difference between lactate concentration at vMLSS (3.54 +/- 0.9 mM) and p(MLSS) (3.76 +/- 0.6 mM). Significant Pearson's coefficients (r > 0.70) were observed among v(MLSS) and P-MLSS with their respective values on time-limited model. Thus, the tethered-crawl condition seems to be valid to determine the boundary of heavy/severe domains, and to access the aerobic capacity of swimmers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As isotermas de sorção da carne de tambaqui desidratada osmoticamente foram determinadas a três temperaturas (5, 17 e 29ºC) e com duas concentrações de solução osmótica (10 e 30% de NaCl), pelo método gravimétrico. Quatro modelos de sorção foram testados para verificar o melhor ajuste; GAB, Oswin, BET e PELEG. Os dados experimentais se ajustaram satisfatoriamente aos modelos. O modelo escolhido para este trabalho foi o de PELEG. Para o ajuste nas curvas de sorção, foi feita a análise de regressão não-linear, usada o programa estatístico ORIGIN 4.0 para estimar as constantes dos modelos. A avaliação do melhor ajuste foi feita pela análise do coeficiente de determinação do ajuste (r²) e teste de Qui-quadrado (x²). Foram analisadas as influências da variação da temperatura e concentração de NaCl na atividade de água da carne do tambaqui. À medida que decresce a temperatura há um decréscimo na atividade de água. Um aumento na concentração do NaCl diminui a atividade de água. A propriedade termodinâmica estudada foi o calor isostérico de sorção. A medida que aumenta a concentração da solução osmótica aumenta o valor do calor isostérico de sorção.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Um método envolvendo a pré-concentração e redissolução anódica em condições de voltametria de pulso diferencial empregando um eletrodo de pasta de carbono modificado (EPCM) com uma resina de troca iônica Amberlite IR120 foi proposto para a determinação de íons chumbo em álcool combustível. O procedimento é baseado em um pico de oxidação do analito observado em -0,53 V(vs. Ag/AgCl) em solução de HCl. As melhores condições experimentais encontradas foram: 5% (m/m) da Amberlite IR120 para a construção do eletrodo, solução de HCl 0,1 mol L-1, velocidade de varredura de 10 mVs-1, tempo de pré-concentração de 15 min e amplitude de pulso de 100 mV. Utilizando essas condições, o EPCM apresentou uma resposta linear entre a corrente de pico anódica e a concentração de íons chumbo para o intervalo entre 9,9 x 10-9 e 1,2 x 10-6 mol L-1 e um limite de detecção de 7,2 x 10-9 mol L-1. Valores de recuperação entre 96 % e 102 % foram encontrados para amostras de álcool combustível enriquecidas com Pb2+ em níveis de 10-7 mol L-1. O efeito da presença de outros íons concomitantes sobre a resposta voltamétrica do eletrodo também foi avaliado.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo do presente estudo foi verificar a utilização da velocidade de 30 minutos (VT-30), freqüência de braçada (fB), comprimento de braçada (CB) e índice de braçada (IB), obtidos no teste T-30, como métodos não-invasivos para determinação da performance aeróbia e técnica de nadadores treinados. Catorze nadadores submeteram-se a três esforços de 400m (85, 90 e 100% do esforço máximo) para determinação da velocidade de limiar anaeróbio (VLan) correspondente à concentração fixa de 3,5mM de lactato e um esforço máximo de 30 minutos (VT-30). fB, CB e IB foram calculados nos 10m centrais da piscina (nado limpo) para o teste T-30 (fBT-30, CBT-30 e IBT-30) e progressivo. Através da relação entre VLan e parâmetros de braçada no teste progressivo, determinaram-se freqüência de braçada de limiar (fBLan), comprimento de braçada de limiar (CBLan) e índice de braçada de limiar (IBLan). O tempo para realizar 400m em máximo esforço foi considerado como parâmetro de performance (P400). Não foi encontrada diferença significativa entre VLan (1,29 ± 0,07m.s-1) e VT-30 (1,29 ± 0,08m.s-1), que ainda apresentaram alta correlação (r = 0,90). Os valores de fBLan (33,6 ± 4,14 ciclos/min) e fBT-30 (34,9 ± 3,53 ciclos/min) e de CBLan (2,09 ± 0,20m/ciclo) e CBT-30 (2,09 ± 0,20m/ciclo) também não foram significativamente diferentes. Correlações significativas (p < 0,05) também foram encontradas entre VT-30 e P400 (r = 0,95); fBLan e fBT-30 (r = 0,73); CBLan e CBT-30 (r = 0,89) e IBLan e IBT-30 (r = 0,94). Conclui-se que a VT30 se mostrou confiável para o monitoramento do treinamento, predição da performance e determinação de parâmetros relacionados à técnica de nadadores.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Realizou-se pesquisa objetivando determinar o melhor entre quatro pontos de colheita da haste floral de crisântemos de maço do tipo pompom cv. White Polaris a concentração mais adequada de sacarose para tratamento de pulsing dessas hastes: estas foram colhidas em estufa de produção comercial, nos pontos preestabelecidos e transportadas para laboratório, onde foram totalmente imersas em água de torneira, à sombra, durante três horas. Selecionaram-se as hastes pela uniformidade do seu desenvolvimento e cortaram-nas sob água na base do caule, entre 50 e 60 cm, e identificadas, o que permitiu avaliar as mudanças morfológicas associadas às inflorescências individuais. As hastes foram distribuídas e mantidas nos diferentes tratamentos de pulsing durante 24 horas, à luz branca contínua de 1.500 lux, 60 a 90% de umidade relativa do ar e temperatura ambiente de 25 ± 2°C. Após o tratamento de pulsing, as hastes foram transferidas para água destilada, permanecendo por 10 horas sob luz branca contínua, nas mesmas condições de laboratório citadas. A vida floral em vaso começou a ser avaliada na instalação do experimento, após o tratamento de pulsing, e terminou quando as folhas e pétalas perderam a turgescência e o valor decorativo. As hastes colhidas em estádio de botão (25 e 50% de abertura das inflorescências apicais) não alcançaram o ponto de abertura adequado em nenhuma das seis concentrações de sacarose (0 a 146,07 mol/m³); as concentrações de 116,9 146,1 mol/m³, porém, estimularam, em geral, a abertura de botões. Os pontos de colheita 1 e 2 (100 e 75% de abertura das inflorescências apicais respectivamente) apresentaram bons resultados em todas as concentrações de sacarose.