943 resultados para Denture (partial, removable)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The free-end removable partial dentures (RPD) shows a complicated and peculiar biomechanical behavior that impose high occlusion forces to the abutment teeth. By this way, the aim of this study was to evaluate the several factors that influence the clasps indication to free-end RPD. It was analysed 84 designed and planned study models of 71 patients, involving 130 clasps near-by a free-end; followed by clinical and radiographical informations. It was observed that bar clasps (“T”, “Tmod”, “i”) were used in 88.46% of abutment teeth. In the others (11.55%), it was used simple, combinated or ring circumferential clasps, and MDL. In abutment teeth with high equator line the “i” clasps were predominant (48.48%). The “Tmod” clasps were predominant in abutment teeth with low equator line (50%) or in middle third (51.35%) and “T” clasps were predominant in inclined equators with mesio-buccal (56.52%) or disto-buccal (66.66%) retention. In the posterior abutment teeth, it was prevalent the distal rest (63.52%) and embracing to the adjacent tooth. Some others factors like long clinical crown (5.38%), wrong position of abutment teeth (4.61%), aesthetics (3.07%), retention in alveolar ridge (2.3%), fragility of abutment teeth (1.53%), short clinical crown (0.76%) and short space to the clasp (0.76%) influenced directly during the clasps selection. Factors like mobility of abutment teeth, height of muscular insertions, depth of buccal fornix and antagonist arch acted like secondary factors. After the informations analysis it may be concluded that the bar clasps with distal rest and embracing to the adjacent tooth were the most indicated to free-end RPD

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The immediate complete denture is defined as a removable or partial denture made to be installed immediately after the extraction of the natural teeth. This type of prosthesis can be used for a short period of time, for aesthetic reasons, mastication, occlusal support, convenience or for the adaptation of the patients to the edentulous state, until the final prosthesis is installed. The objective of this study was to report a surgical and prosthetic rehabilitation planning of a patient by means of an immediate complete maxillary denture, and the results obtained with this treatment modality. The immediate complete denture is a necessary, well-established, useful and effective prosthetic procedure for patients who, inevitably, will present an edentulous state, despite it is a slightly more expensive and it requires more sessions for adjust

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Removable partial denture improve functional and aesthetic failures caused by partial loss of teeth, however specific characteristics of each patients can determine the success of treatment, especially with regard to the support of the prosthesis, which may depend on teeth, the combination of teehe and mucosa and currently associated with the dental implants. The aim of this study is report a case in which there was the need of the association, to enable better aesthetics and self-esteem to the patients. After implant placement and fabrication of prosthetic patient reported satisfaction with the rehabilitation treatment, improving their quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The literature has suggested that the association of removable partial dentures with dental implants can improve the quality of life of patients. Thus, the purpose of this study was to present a case report. This case report describes the development of a removable partial denture associated with dental implants bilaterally been monitored for 12 years, and the efficacy of the proposed treatment. The radiographic controls demonstrated no changes on bone tissue. The maxillary arch was rehabilitated with metal-free crowns. The patient was fully satisfied with this technique providing stability, esthetics, and proper function. It was concluded that the technique of using removable partial dentures associated with dental implants is viable and show the advantages of improved function, aesthetics and cost reductions in rehabilitation treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present article describes the treatment planning and fabrication of overlay denture to restore the jaw relationship in a partial edentulous patient with bruxism. A male patient, 51 years old, was referred to the oral rehabilitation clinic complaining about the chewing and aesthetic. The occlusal surface of the superior teeth presented severe wear. The fabrication of an interim overlay denture to restore the jaw relationship was planned. The overlay had metallic projections and covered the occlusal surface of superior teeth. After overlay insertion both function and aesthetic of the patient were recovered. It was concluded that the use of overlay improved the physiological normal position of the jaw and could provide a favorable prognosis for a definitive oral rehabilitation with implant-supported fixed denture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Maxillofacial deformities may cause awkward and embarrassing bearer. These patients present serious psychological, family and social issues becoming traumatized and complexed. These deformities can have congenital origin, malformations and developmental disorders, or can be caused by pathological mutilation such as necrotizing diseases and surgical oncology, or traumas such as traffic and work accidents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The rehabilitation with mandibular distal extension removable partial dentures (DERPD) is complex and the use of implants has been improving the functioning of this approach. The insertion bony level around of the last support tooth is an aggravating factor, since it can harm the longevity of the treatment. Thus, the aim of this research was to evaluate the displacement tendency of a mandibular DERPD associated to an implant, with different insertion bony levels and different connections between the RPD and the support tooth, by finite element analysis. Eight models were made: MA - DERPD, incisal rest, no bony loss; MB - DERPD, distal plate, no bony loss; MC - DERPD, incisal rest, no bony loss, with implant and ERA system; MD - DERPD, distal plate, no bony loss, with implant and ERA system; ME - DERPD, incisal rest, bony loss; MF - DERPD, distal plate, bony loss; MG - DERPD, incisal rest, bony loss, with implant and ERA system; MH - DERPD, distal plate, bony loss, with implant and ERA system. Loads of 50 N in each peak were applied. Displacement maps were obtained and showed that implant favors this association and the bony loss harms the prognostic of the prosthesis. It is concluded that: the introduction of the implant with ERA system reduced the displacement tendency of the tooth and supporting structures; introduction of distal plate reduced the movement tendency of the support tooth; the decrease of the periodontal support didn't influence significantly the displacement tendency of the models with distal plate distal, but it influenced the models with distal incisal rest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Ectodermal Dysplasias are a heterogeneous group of inherited disorders characterized by dysplasia of tissues of ectodermal origin (hair, nails, teeth, skins and glands). Clinically, it may be divided into two broad categories: the X-linked hypoidrotic form and the hidrotic form. Hypohidrotic Ectodermal Dysplasia (H.E.D) is characterized by the triad oligo-anodontia, hypotricosis, hypo-anhydrosis (Christ-Siemens-Tourane syndrome). The incidence of HED is about 1/100,000. Mutation in the actodysplasin-A (EDA) and ectodysplasin-A receptor (EDAR) genes are responsible for X-linked and autosomal HED. The clinical features include sparse, fine hair, missing or conical-shaped teeth, decreased sweat and mucous glands, hypoplastic skin, and heat intolerance with exercise or increased ambient temperature. Complete or partial anodontia and malformation of teeth are the most frequent dental findings. Incisors and canines are often conical-shaped while primarily second molars, if present, are mostly affected by taurodontism. Treatment is supportive and includes protection from heat exposure, early prosthetic rehabilitation, skin, hair ear, nose and nail care, and genetic counseling for family planning. The diagnosis of HED in the neonatal and early infancy period may be difficult since sparse hair and absent teeth are normal finding at this age. In childhood the diagnosis is more easily made on the basis of history and clinical examination. Dental abnormalities are the most common complaint. Prosthetic rehabilitation has been recommended as an essential part of the management of HED because is important from functional, esthetic, and psychological standpoint. A team approach that includes input from a pediatric dentist, an orthodontist, a prosthodontist, and an oral and maxillofacial surgeon is necessary for a successful outcome. Conventional prosthodontic rehabilitation in young patient is often difficult because of the anatomical abnormalities of existing teeth and alveolar ridges. The conical shaped teeth and “knife-edge” alveolar ridges result in poor retention and instability of dentures. Moreover, denture must permit jaws expansion and a correct pattern of growth. Materials and Methods. Complete removable dentures were provided to allow for normal physiological development and a corrected masticatory function. Initial maxillary and mandibular impressions were made with smallest stock trays and irreversible hydrocolloid and then final impressions ware made with light-bodied polysulfide rubber base impression material. A base of autopolymerizing resin was constructed and a wax rim was added to the base. The patient’s vertical dimension of occlusion was established by assessing phonetic and esthetic criteria. Preliminary occlusal relations were recorded, and the mandibular cast was mounted on the articulator. Acrylic resin teeth specific for children dentures were selected and mounted. The dentures were tried in and, after proper adjustments, were inserted. The patients were monitored clinically every month to fit prostheses. Cephalometric radiographs were taken every 6 month with the prostheses in place in order to evaluate correct pattern of growth. Cephalometric measurements were realized and used to evaluate the effect of rehabilitation on craniofacial growth. Cephalometric measurements of sound patients were compared with ED patients. After two month expander screws (three-way screw in the upper denture and two-way the lower one)were inserted in each denture in order to permit the expansion of the denture and the jaws growth. Where conical teeth were present, composite crown were realized and luted to improve the esthetic and phonesis. In order to improve retention the placement of endosseous implants was carried out. TC 3D Accuitomo was performed and a resin model of mandibular bone of the patient was realized. At the age of 11 years two implants were inserted into anterior mandible in a child with anodontia. Despite a remarkable multi-dimensional atrophy of the mandibular alveolar process, the insertion of two tapered screw implants (SAMO Smiler, diameter 3.8, length 10 mm). After a submerged healing period of two-three month, the implants were exposed. Implants were connected with an expansion guide that permits mandibular growth and prosthetic retention. The amount of mandibular growth was also evaluate dusing the expansion guide. Results. Early oral rehabilitation improve oral function, phonesis and esthetic, reducing social impairment. Treated patients showed normal cephalometric measurement. Early rehabilitation is able to prevent the prognatissm of the mandibula . The number of teeth was significantly related to several changes in craniofacial morphology. Discussion. In the present study the 5,3% of ED patients showed hypodontia, the l’89,4% di oligodontia, and the 5,3% di anodontia. The cephalometric analysis supports that ED patients showed midface hypoplasia. ED groups showed an increased pogonion to nasion measurement than sound patients, indicative of class III tendency. The present study demonstrated that number of teeth was significantly correlated with deviation of cephalometric measurements from normality. Oligoanodontia is responsible for changing of cephalometric measuraments also on sagittal plane with a class III tendency. Maxillary jaw showed a retrused position related to the presence of hypodontia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The new Swiss implant system SPI became available three years ago and is used in combination with fixed and removable prosthetic reconstructions. In a pilot study the clinical procedures were evaluated and data of prosthetic complications of maintenance service were collected. 25 patients participated in the study with a total of 79 SPI implants during the time period from 2003-2004. 37 implants were located in the maxilla and 42 implants in the mandible. Two implants failed during the healing period, but no loaded implant was lost. Thus, the survival rate was 97.5% (77/79). 44 implants supported a fixed prosthesis, including nine single crowns and 33 implants were used in combination with removable partial denture. Four implants were used with ball anchor retention, 29 with bar support. The ELEMENT implant with the low implant shoulder allows very good esthetics. Prosthetic complications and maintenance service during the first year of function was comparable with other implant systems. Since the design of the abutment screws, healing caps and screwdriver was changed, the system has become easier in its application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Different types of titanium-alloys instead of CoCr-alloys have been tested as material for the framework of removable partial dentures (RPD). Adequate casting and processing techniques have been developed which enable to fabricate frameworks of complex designs and the problem limits porosity. This opened new possibilities for the use of titanium-alloys with improved properties (E-module). The aim of this study was to summarise the use of titanium in removable prosthodontics and to evaluate prospectively the use of the Ti6A17Nb-alloy for RPDs in a small group of patients. Two identically designed RPDs from CoCr-alloy (remanium GM 800+) and Ti6A17Nb-alloy (girotan L) were produced for ten patients. They had to wear each RPD during six months, first the CoCr-RPD and then the Ti6A17Nb-RPD. A questionnaire (visual analogue scale = VAS) was completed by the patients after one, three and six months of function for each RPD. Prosthetic complications and service needed were recorded. After the end of the entire observation period of twelve months, the patients remained with the Ti6A17Nb-RPD and answered the questionnaire after another six months. All parameters regarding the design of the RPDs were positively estimated by the dentist. Minimal, not significant differences were noted by the patients concerning comfort, stability and retention (VAS). Clinically, no differences in technical aspects or regarding biological complications were observed after six-months periods. The Ti6A17Nb-alloy (girotan L) for the framework of RPDs was judged by patients and professionals to be equivalent to RPDs made from CoCr-alloy. No differences in material aspects could objectively be observed. The Ti6A17Nb-alloy can be beneficial for patients with allergies or incompatibility with one or several components of the CoCr-alloy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To systematically appraise the impact of mechanical/technical risk factors on implant-supported reconstructions. MATERIAL AND METHODS: A MEDLINE (PubMed) database search from 1966 to April 2008 was conducted. The search strategy was a combination of MeSH terms and the key words: design, dental implant(s), risk, prosthodontics, fixed prosthodontics, fixed partial denture(s), fixed dental prosthesis (FDP), fixed reconstruction(s), oral rehabilitation, bridge(s), removable partial denture(s), overdenture(s). Randomized controlled trials, controlled trials, and prospective and retrospective cohort studies with a mean follow-up of at least 4 years were included. The material evaluated in each study had to include cases with/without exposure to the risk factor. RESULTS: From 3,568 articles, 111 were selected for full text analysis. Of the 111 articles, 33 were included for data extraction after grouping the outcomes into 10 risk factors: type of retentive elements supporting overdentures, presence of cantilever extension(s), cemented versus screw-retained FDPs, angled/angulated abutments, bruxism, crown/implant ratio, length of the suprastructure, prosthetic materials, number of implants supporting an FDP, and history of mechanical/technical complications. CONCLUSIONS: The absence of a metal framework in overdentures, the presence of cantilever extension(s) > 15 mm and of bruxism, the length of the reconstruction, and a history of repeated complications were associated with increased mechanical/technical complications. The type of retention, the presence of angled abutments, the crown-implant ratio, and the number of implants supporting an FDP were not associated with increased mechanical/technical complications. None of the mechanical/technical risk factors had an impact on implant survival and success rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this research was to study the impact of loading on partial dentures within the supporting soft tissue with respect to different attachment techniques. A finite element model was developed to calculate the stress and strain distribution in this tissue. The model consisted of the left half of a mandible with three remaining teeth that had suffered an atrophy in the anterior region, and a partial denture over the toothless area that was connected at the left mandibular canine using an attachment system. Resulting stress/strain distributions are presented for different load cases using a commercially available prefabricated attachment system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare and to evaluate the stability of the retentive force of cobalt-chromium (Co-Cr) circumferential clasps (control) to those with an acetyl resin retentive arm. METHODS: Sixteen specimens with a couple of circumferential clasps were made using Co-Cr over a metal model providing 0.25 mm undercuts. Eight specimens were fabricated without the anterior retentive arm, which was made later using acetyl resin (Dental D). Insertion and removal simulation test was performed through 7250 cycles. The retentive force was recorded in Newtons (N) for periods corresponding to 0, 1, 2, 3, 4, and 5 years. The data were subjected to ANOVA and Tukey test to compare periods and to Student's t test to compare groups (α=0.05). RESULTS: Mean (SD) is presented for Co-Cr and resin groups, respectively: 8.09(3.05) and 2.79(1.57) in period 0; 10.48(4.25) and 3.32(1.92) in 1 year; 10.09(4.15) and 3.47(1.81) in 2 years; 9.87(4.30) and 3.46(1.87) in 3 years; 9.46(3.93) and 3.27(1.59) in 4 years; 9.63(3.79) and 3.41(1.59) in 5 years. There were significant differences for Co-Cr between periods of 0 and 1 (p<0.001), 0 and 2 (p<0.01) and 0 and 3 (p<0.05). In the resin group, no significant differences were found between periods (p>0.05). Comparisons between the groups showed statistical differences for all tested periods: 0 (p=0.0012), 1 (p=0.0013), 2 (p=0.0019), 3 (p=0.0031), 4 (p=0.0027) and 5 years (p=0.0014). CONCLUSIONS: Acetyl resin retentive arms, even if only in the anterior clasps, can significantly reduce the retentive force, but this force remained stable after 5 years of simulated use.