979 resultados para Dentistry, Operative


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The functional results associated with nonoperative treatment of severely impacted valgus fractures of the proximal part of the humerus are poor, and these injuries are difficult to treat with minimally invasive percutaneous fixation techniques. The aim of this study was to review the functional and radiographic results and complications of a new operative technique in a series of twenty-five patients.

Methods: Over a two-year period, we treated twenty-nine patients with a severely impacted valgus fracture of the proximal part of the humerus. Three patients were lost to follow-up and one died, leaving twenty-five patients who were available for the study. In all of the fractures, the head-shaft angle had been tilted into =160° of valgus and the greater tuberosity was displaced by >1 cm. All patients were treated with open reduction of the fracture, and the space created behind the humeral head was filled with Norian Skeletal Repair System (SRS) bone substitute. The fractures were stabilized with either screws or buttress plate fixation. Associated rotator cuff tears were repaired. All patients underwent functional outcome assessment with use of the Constant, DASH (Disabilities of the Arm, Shoulder and Hand), and SF-36 (Short Form-36) scores at one year, and twelve patients were followed for two years.

Results: All fractures united within the first year, all reductions were maintained, and no patient had signs of osteonecrosis of the humeral head on the latest follow-up radiographs. At one year, the median Constant score was 80 points and the median DASH score was 22 points. The functional results continued to be satisfactory in the twelve patients who were followed for two years. The results in our series were better than those achieved in studies of nonoperative treatment of similar fracture configurations. There were six clinically relevant complications, although none required a reoperation and all six patients had a satisfactory short-term functional outcome.

Conclusions: Internal fixation of severely impacted valgus fractures of the proximal part of the humerus, supplemented by Norian SRS bone substitute to fill the proximal humeral metaphyseal defect, produces good early functional and radiographic outcomes. Additional follow-up will be required to assess whether these initially satisfactory outcomes are maintained over the longer term.

Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Website design. Development and identity roll out for the Beggars Opera Co-Operative

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evidence from clinical practice and the extant literature suggests that post-operative pain assessment and treatment is often suboptimal. Poor pain management is likely to persist until pain management practices become consistent with guidelines developed from the best available scientific evidence. This work will address the priority in healthcare of improving the quality of pain management by standardising evidence-based care processes through the incorporation of an algorithm derived from best evidence into clinical practice. In this paper, the methodology for the creation and implementation of such an algorithm that will focus, in the first instance, on patients who have undergone total hip or knee replacement is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Use of surgery for the treatment of infective endocarditis (IE) as related to surgical indications and operative risk for mortality has not been well defined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Economic evaluation (EE) studies have been undertaken in dentistry since the late 20th century because economic data provide additional information to policy makers to develop guidelines and set future direction for oral health services. The objectives of this study were to assess the methodological quality of EEs in oral health. Electronic searching of Ovid MEDLINE, the Cochrane Library, and the NHS Economic Evaluation Database from 1975 to 2013 were undertaken to identify publications that include costs and outcomes in dentistry. Relevant reference lists were also searched for additional studies. Studies were retrieved and reviewed independently for inclusion by 3 authors. Furthermore, to appraise the EE methods, 1 author applied the Drummond 10-item (13-criteria) checklist tool to each study. Of the 114 publications identified, 79 studies were considered full EE and 35 partial. Twenty-eight studies (30%) were published between the years 2011 and 2013. Sixty-four (53%) studies focused on dental caries prevention or treatment. Median appraisal scores calculated for full and partial EE studies were 11 and 9 out of 13, respectively. Quality assessment scores showed that the quality of partial EE studies published after 2000 significantly improved (P = 0.02) compared to those published before 2000. Significant quality improvement was not found in full EE studies. Common methodological limitations were identified: absence of sensitivity analysis, discounting, and insufficient information on how costs and outcomes were measured and valued. EE studies in dentistry increased over the last 40 y in both quantity and quality, but a number of publications failed to satisfy some components of standard EE research methods, such as sensitivity analysis and discounting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: While the risk of adverse events following surgery has been identified, the impact of nursing care on early detection of these events is not well established. A systematic review of the evidence and an expert consensus study in post-anaesthetic care identified essential criteria for nursing assessment of patient readiness for discharge from the Post-Anaesthetic Care Unit. These criteria were included in a new nursing assessment tool, the Post-Anaesthetic Care Tool (PACT), and incorporated into the post-anaesthetic documentation at a large health service. The aim of this study is to test the clinical reliability of the PACT and evaluate whether use of PACT will i) enhance the recognition and response to patients at risk of deterioration in PACU; ii) improve documentation for handover from PACU nurse to ward nurse; iii) result in improved patient outcomes; and iv) reduce health care costs.

Methods and analysis
: A prospective, non-randomised, pre- and post-implementation design comparing: (i) patients (n=750) who have surgery prior to the implementation of the PACT and (ii) patients (n=750) who have surgery after PACT. The study will examine the use of the tool through the observation of patient care and nursing handover. Patient outcomes and cost effectiveness will be determined from health service data and medical record audit. Descriptive statistics will be used to describe the sample and compare the two patient groups (pre- and post-intervention). Differences in patient outcomes between the two groups will be compared using the Cochran-Mantel-Haenszel test and regression analyses and reported as odds ratios with the corresponding 95% confidence intervals.

Conclusion: This study will test the clinical reliability and cost-effectiveness of the PACT. It is hypothesised that the PACT will enable nurses to recognise and respond to patients at risk of deterioration, improve handover to ward nurses, improve patient outcomes, and reduce health care costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:
The factors influencing the decision making of operative treatment for fractures of the proximal humerus are debated. We hypothesized that there is no difference in treatment recommendations between surgeons shown radiographs alone and those shown radiographs and patient information. Secondarily, we addressed (1) factors associated with a recommendation for operative treatment, (2) factors associated with recommendation for arthroplasty, (3) concordance with the recommendations of the treating surgeons, and (4) factors affecting the inter-rater reliability of treatment recommendations.
Methods: A total of 238 surgeons of the Science of Variation Group rated 40 radiographs of patients with proximal humerus fractures. Participants were randomized to receive information about the patient and mechanism of injury. The response variables included the choice of treatment (operative vs nonoperative) and the percentage of matches with the actual treatment.
Results: Participants who received patient information recommended operative treatment less than those who received no information. The patient information that had the greatest influence on treatment recommendations included age (55%) and fracture me chanism (32%). The only other factor associated with a recommendation for operative treatment was region of practice. There was no significant difference between participants who were and were not provided with information regarding agreement with the actual treatment (operative vs nonoperative) provided by the treating surgeon.
Conclusion: Patient information - older age in particular - is associated with a higher likelihood of recommending nonoperative treatment than radiographs alone. Clinical information did not improve agreement of the Science of Variation Group with the actual treatment or the generally poor interobserver agreement on treatment recommendations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the Ergonomic Work Analysis method in a Brazilian Dentist's office. Through the study, the constraints and the strategies in avoiding them were identified. It was found that dentists hardly use the position most indicated by the International Organization for Standardization (ISO) and the Federation Dentaire Internacionale (FDI) for both the patient and the dentist, which is respectively supine and 9 o'clock, due to the limited space and layout. Five types of treatments performed by the professional have been studied. The frequency and duration of actions in these treatments were accounted for and the standard positions adopted were identified. The AET was found to be a very suitable method to grasp the dentist's activity and build a point of view of the profession, which is characterized as: stressful, perfectionist and restrictive. Time management is presented as an important strategy to control the tension arising from performing the treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectiveTo compare the post-operative analgesic effects of butorphanol or firocoxib in dogs undergoing ovariohysterectomy.Study designProspective, randomized, blinded, clinical trial.AnimalsTwenty-five dogs > 1 year of age.MethodsDogs received acepromazine intramuscularly (IM), 0.05 mg kg-1 and either butorphanol IM, 0.2 mg kg-1 (BG, n = 12) or firocoxib orally (PO), 5 mg kg-1 (FG, n = 13), approximately 30 minutes before induction of anesthesia with propofol. Anesthesia was maintained with isoflurane. Ovariohysterectomy was performed by the same surgeon. Pain scores using the dynamic and interactive visual analog scale (DIVAS) were performed before and at 1, 2, 3, 4, 6, 8 and 20 hours after the end of surgery by one observer, blinded to the treatment. Rescue analgesia was provided with morphine (0.5 mg kg-1) IM and firocoxib, 5 mg kg-1 (BG only) PO if DIVAS > 50. Groups were compared using paired t-tests and Fisher's exact test (p < 0.05). Data are presented as mean +/- SD.ResultsThe BG required significantly less propofol (BG: 2.6 +/- 0.59 mg kg-1; FG: 5.39 +/- 0.7 mg kg-1) (p < 0.05) but the anesthesia time was longer (BG: 14 +/- 6, FG: 10 +/- 4 minutes). There were no differences for body weight (BG: 7.9 +/- 5.0, FG: 11.5 +/- 4.6 kg), sedation scores, and surgery and extubation times (BG: 10 +/- 2, 8 +/- 5 minutes; FG: 9 +/- 3, 8 +/- 4 minutes, respectively) (p > 0.05). The FG had significantly lower pain scores than the BG at 1, 2 and 3 hours following surgery (p < 0.05). Rescue analgesia was administered to 11/12 (92%) and 2/13 (15%) dogs in the BG and FG, respectively (p < 0.05).Conclusion and clinical relevanceFirocoxib produced better post-operative analgesia than butorphanol. Firocoxib may be used as part of a multimodal analgesia protocol but may not be effective as a sole analgesic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of cycling various pH demineralizing solutions on the surface hardness, fluoride release and surface properties of restorative materials (Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil). Thirty specimens of each material were made and the surface hardness measured. The specimens were randomized into five groups according to the pH (4.3; 4.6; 5.0; 5.5 and 6.2) of the demineralizing solution. The specimens were submitted to pH-cycling for 15 days. The specimens remained in the demineralizing solution for six hours and in the remineralizing solution for 18 hours. Then, the surface hardness (SH) was remeasured and the surface properties were assessed. Fluoride release was determined daily. Data from SH and the percentage of alteration in surface hardness were analyzed by analysis of variance (p < 0.05); the Kruskal-Wallis test was performed for the fluoride release results. When hardness was compared, the variation in pH led to a positive correlation for glass ionomer cements and a negative correlation for fluoride release. For polyacid-modified resin composites, a negative correlation was found with regards to fluoride release; no significant correlation was observed for hardness. Surface properties were influenced: an acidic pH led to a greater alteration, except for polyacid-modified resin composites. The pH of the demineralizing solution influenced fluoride release from the tested materials. The pH variation altered hardness and surface properties of glass ionomer cements but did not influence polyacid-modified resin composites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of implant-supported prosthesis to replace missing teeth became a predictable treatment. Although high success rate has been reported, implant treatment is suitable to complications, failures, and limitations such as peri-implant bone loss after implant loading. Stress evaluation on the bone-abutment-implant interface has been carried out to develop new designs of prosthetic platform and to understand the stress distribution in this interface. Several types of prosthetic platforms are available such as external and internal hexagon, Morse cone connection, and the concept of platform switching. Therefore, this study aimed to critically describe the different options of prosthetic platforms in implant dentistry, by discussing their biomechanical concepts, clinical use, and advantages and disadvantages. It was observed that all types of prosthetic platforms provided high success rate of the implant treatment by following a strict criteria of indication and limitation. In conclusion, a reverse planning of implant treatment is strongly indicated to reduce implant overload, and the use of advanced surgical-prosthetic techniques is required to obtain a long-term success of oral rehabilitations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)