968 resultados para DIAPHRAGM PUMP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prototype vortex-driven air lift pump was developed and experimentally evaluated. It was designed to be easily manufactured and scalable for arbitrary riser diameters. The model tested fit in a 2 inch diameter riser with six air injection nozzles through which airwas injected helically around the perimeter of the riser at an angle of 70º from pure tangential injection. The pump was intended to transport both water and sediment over a large range of submergence ratios. A test apparatus was designed to be able to simulate deep water or oceanic environments. The resulting test setup had a finite reservoir; over the course of a test, the submergence ratio varied from 0.48 to 0.39. For air injection pressures ranging from 10 to 60 psig and for air flow rates of 6 to 15 scfm, the induced water discharge flow rates varied only slightly, due to the limited range of available submergence ratios. The anticipated simulation of deep water environment, with a corresponding equivalent increase in thesubmergence ratio, proved unattainable. The pump prototype successfully transported both water and sediment (sand). Thepercent volume yield of the sediment was in an acceptable range. The pump design has been subsequently used successfully in a 4 inch configuration in a follow-on project. A computer program was written in Matlab to simulate the pump characteristics. The program output water pressures at the location of air injection which were physicallycompatible with the experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Mismatches between pump output and venous return in a continuous-flow ventricular assist device may elicit episodes of ventricular suction. This research describes a series of in vitro experiments to characterize the operating conditions under which the EVAHEART centrifugal blood pump (Sun Medical Technology Research Corp., Nagano, Japan) can be operated with minimal concern regarding left ventricular (LV) suction. Methods: The pump was interposed into a pneumatically driven pulsatile mock circulatory system (MCS) in the ventricular apex to aorta configuration. Under varying conditions of preload, afterload, and systolic pressure, the speed of the pump was increased step-wise until suction was observed. Identification of suction was based on pump inlet pressure. Results: In the case of reduced LV systolic pressure, reduced preload (=10 mmHg), and afterload (=60 mmHg), suction was observed for speeds =2,200 rpm. However, suction did not occur at any speed (up to a maximum speed of 2,400 rpm) when preload was kept within 10-14 mmHg and afterload =80 mmHg. Although in vitro experiments cannot replace in vivo models, the results indicated that ventricular suction can be avoided if sufficient preload and afterload are maintained. Conclusion: Conditions of hypovolemia and/or hypotension may increase the risk of suction at the highest speeds, irrespective of the native ventricular systolic pressure. However, in vitro guidelines are not directly transferrable to the clinical situation; therefore, patient-specific evaluation is recommended, which can be aided by ultrasonography at various points in the course of support.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial depression after cardiac surgery is modulated by cardiopulmonary bypass (CPB) and the underlying heart disease. The sodium pump is a key component for myocardial function. We hypothesized that the change in sodium pump expression during CPB correlates with intraoperative and postoperative laboratory and clinical parameters in neonates and children with various congenital heart defects. Sodium pump isoforms alpha1 (ATP1A1) and alpha3 (ATP1A3) mRNA expression in right atrial myocardium, excised before and after CPB, was quantified. Groups were assigned according to presence (VO group, n = 8) or absence (NO group, n = 8) of right atrial volume overload. CPB and aortic clamp time correlated with postoperative troponin-I values and ICU stay. ATP1A1 (P = 0.008) and ATP1A3 (P = 0.038) mRNA expression were significantly reduced during CPB. Longer aortic clamp times were associated with lower postoperative ATP1A1 (P = 0.045) and ATP1A3 (P = 0.002) mRNA expression. Low postoperative ATP1A1 (P = 0.043) and ATP1A3 (P = 0.002) expressions were associated with high troponin-I values. These results were restricted to the VO group. No correlation of sodium pump mRNA expression was found with the duration of ICU stay or ventilation. The postoperative troponin-I and clinical parameters correlated with the length of CPB, regardless of volume overload. In contrast, only dilated right atrium seemed to be susceptible to CPB in terms of sodium pump expression, showing a reduction during the operation and a correlation of sodium pump with postoperative troponin-I values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Episodes of respiratory distress with chest retraction and wheezing, sometimes associated with facial edema, were noted after administering the proton pump inhibitors omeprazole and esomeprazole in an infant with gastroesophageal reflux. The disturbances relieved dramatically after withdrawing the proton pump inhibitor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An active implanted pump was chosen to illustrate the method. A set of controlled experiments were proposed and performed to validate the numerical model. The calculated induced voltages in the important electronic components of the device showed dependence with the MRI field strength. For the MRI radiofrequency fields, significant induced voltages of up to 20 V were calculated for a 0.3T field-strength MRI. For the 1.5 and 3.0T MRIs, the calculated voltages were insignificant. On the other hand, induced voltages up to 11 V were calculated in the critical electronic components for the 3.0T MRI due to the gradient fields. Values obtained in this work reflect to the worst case situation which is virtually impossible to achieve in normal scanning situations. Since the calculated voltages may be removed by appropriate protection circuits, no critical problems affecting the normal operation of the pump were identified. This study showed that the proposed methodology helps the identification of the possible incompatibilities between active implants and MR imaging, and can be used to aid the design of critical electronic systems to ensure MRI-safety

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Residual airspace following thoracic resections is a common clinical problem. Persistent air leak, prolonged drainage time, and reduced hemostasis extend hospital stay and morbidity. We report a trial of pharmacologic-induced diaphragmatic paralysis through continuous paraphrenic injection of lidocaine to reduced residual airspace. The objectives were confirmation of diaphragmatic paralysis and possible procedure related complications. METHODS: Six eligible patients undergoing resectional surgery (lobectomy or bilobectomy) were included. Inclusion criteria consisted of: postoperative predicted FEV1 greater than 1300 ml, right-sided resection, absence of parenchymal lung disease, no class III antiarrhythmic therapy, absence of hypersensitivity reactions to lidocaine, no signs of infection, and informed consent. Upon completion of resection an epidural catheter was attached in the periphrenic tissue on the proximal pericardial surface, externalized through a separate parasternal incision, and connected to a perfusing system injecting lidocaine 1% at a rate of 3 ml/h (30 mg/h). Postoperative ICU surveillance for 24h and daily measurement of vital signs, drainage output, and bedside spirometry were performed. Within 48 h fluoroscopic confirmation of diaphragmatic paralysis was obtained. The catheter removal coincided with the chest tube removal when no procedural related complications occurred. RESULTS: None of the patients reported respiratory impairment. Diaphragmatic paralysis was documented in all patients. Upon removal of catheter or discontinuation of lidocaine prompt return of diaphragmatic motility was noticed. Two patients showed postoperative hemodynamic irrelevant atrial fibrillation. CONCLUSION: Postoperative paraphrenic catheter administration of lidocaine to ensure reversible diaphragmatic paralysis is safe and reproducible. Further studies have to assess a benefit in terms of reduction in morbidity, drainage time, and hospital stay, and determine the patients who will profit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FGFRL1 is a recently discovered member of the fibroblast growth factor receptor family that is lacking the intracellular tyrosine kinase domain. To elucidate the function of the novel receptor, we created mice with a targeted disruption of the Fgfrl1 gene. These mice develop normally until term, but die within a few minutes after birth due to respiratory failure. The respiratory problems are explained by a significant reduction in the size of the diaphragm muscle, which is not sufficient to inflate the lungs after birth. The remaining portion of the diaphragm muscle appears to be well developed and innervated. It consists of differentiated myofibers with nuclei at the periphery. Fast and slow muscle fibers occur in normal proportions. The myogenic regulatory factors MyoD, Myf5, myogenin and Mrf4 and the myocyte enhancer factors Mef2A, Mef2B, Mef2C and Mef2D are expressed at normal levels. Experiments with a cell culture model involving C2C12 myoblasts show that Fgfrl1 is expressed during the late stages of myotube formation. Other skeletal muscles do not appear to be affected in the Fgfrl1 deficient mice. Thus, Fgfrl1 plays a critical role in the development of the diaphragm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Despite advances in surgical and interventional techniques, the optimal surgical treatment of severe aortic (re) coarctation and hypoplastic aortic arch is still controversial. Anatomic repair may require extensive dissection, cardiopulmonary bypass, and deep hypothermic circulatory arrest with their inherent risks. The aim of this study was to analyze the outcome of off-pump extraanatomic aortic bypass as a surgical alternative to local repair. METHODS: From February 2000 to December 2005, ten consecutive patients (median age 20 years; range, 11 to 38 years) with severe aortic (re) coarctation (n = 4) and (or) hypoplastic aortic arch (n = 7) underwent off-pump extraanatomic aortic bypass through median sternotomy. All but three patients had undergone previous surgery for coarctation and angioplasty or stenting. Three patients underwent concomitant replacement of the ascending aorta because of an aneurysm using cardiopulmonary bypass. RESULTS: Postoperative hospital course was uneventful in all patients. There was no perioperative mortality or significant morbidity. During a mean follow-up of 48 +/- 22 months no patient required additional procedures. All patients were free of symptoms; no patient showed signs of heart failure after follow-up. At last follow-up, no patient presented with claudication, nor any patient experienced orthostatic problems due to a steal phenomenon. During follow-up, hypertension resolved in all patients with residual mild hypertension in two patients. CONCLUSIONS: Off-pump extraanatomic aortic bypass is an attractive treatment option for complex aortic (re) coarctation and hypoplastic aortic arch. Perioperative risks are minimized, hypertension is influenced favorably, and midterm survival is event-free.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to determine anticoagulation strategies in OPCAB a questionnaire survey among 750 European cardio-thoracic surgeons was performed. Questions addressed volume of OPCAB procedures performed, intra- and perioperative heparinization and antiplatelet therapy, as well as perioperative management. A total of 325 (43.7%) questionnaires were returned and validated. Perioperative protocols for administration of antiplatelets differed among the respondent surgeons. Perioperative prophylaxis of thrombosis (low or high molecular weight heparin) is performed by 78%. Intraoperative heparin dosage range between 70 U/kg to 500 U/kg, 60% of respondents prefer a low-dose regimen (< or = 150 U/kg). Correspondingly, the lowest activated clotting time (ACT) during surgery is accepted to be 200 s by 24%, 250 s by 18% and 300 s by 26% of surgeons. Protamine is used by 91% of respondents, while 52% perform a 1:1 reversal. A cell-saver and antifibrinolytics are used by 70% and 40%, respectively. Interestingly, 56% of respondents think bleeding in OPCAB patients is not reduced when compared to on-pump CABG. In addition, 34% of respondents believe there is an increased risk of early graft occlusion following OPCAB. This survey demonstrates widely different intra- and perioperative anticoagulation strategies for OPCAB procedures among European surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gene transfer using electroporation is an essential method for the study of developmental biology, especially to understand the internal control of degeneration and apoptosis of the muscle cells that occurs earlier and quicker than the usual degeneration process occurring by aging. Such experimental studies may have a role in developing new strategies for treating patients suffering from inherited primary myopathies such as Duchenne muscular dystrophy (DMD). The present study was designed to evaluate the feasibility of electroporation mediated transfer of reporter genes to the diaphragm in vivo. This is the first report of gene transfer of naked plasmid DNA into the diaphragm muscle in vivo using electroporation. Our results showed that in vivo gene transfer of naked plasmid DNA into the diaphragm muscle using electroporation is feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study analyzes the effects on coagulation and fibrinolysis comparing off-pump coronary artery bypass (OPCAB) and on-pump CABG operations. METHODS: In a prospective, nonrandomized, comparative evaluation, patients scheduled for elective myocardial revascularization were studied. Due to possible confounding factors patients with postoperative retransfusion of mediastinal shed blood were excluded. Nine patients underwent OPCAB operation and 16 underwent on-pump CABG. Activated clotting time (ACT) was adjusted to 250 seconds in OPCAB (81 +/- 18 [mean +/- SD] IU/kg heparin) and to more than 480 seconds in on-pump CABG (400 IU/kg heparin, additional 10,000 IU in pump prime). Perioperatively blood samples were collected and hematologic and hemostatic variables including fibrinopeptide A (FPA), fibrin monomer (FM), thrombin-antithrombin complex (TAT), and D-dimer were analyzed. RESULTS: Both groups showed comparable demographic variables. Number of grafts per patient was slightly higher in the on-pump group (3.6 +/- 0.6 versus 3.0 +/- 1.1, p = 0.23). The FPA levels did not differ significantly between the groups. The FM, TAT, and D-dimer values were significantly higher in on-pump CABG (p < 0.0001, p < 0.01, and p < 0.0001, respectively), reflecting increased coagulant and fibrinolytic activity. This was also the case when values were corrected for hemodilution. CONCLUSIONS: Despite lower systemic anticoagulation activation of coagulation and fibrinolysis is reduced in OPCAB compared with on-pump CABG. Reduced thrombin generation and reduced fibrinolytic activity in OPCAB indicates better preservation of hemostasis. We suggest the term "preserved hemostasis" instead of "hypercoagulant activity" with respect to OPCAB.