965 resultados para DIAMETRO APICAL
Resumo:
Information about orthodontic movement of teeth with hypercementosis is scarce. As cementum deposition continues to occur, cementum is expected to change the shape of the root and apex over time, but this has not yet been demonstrated. Nor has it ever been established whether it increases or decreases the prevalence of root resorption during orthodontic treatment. The unique biological function of the interconnected network of cementocytes may play a role in orthodontic movement and its associated root resorptions, but no research has ever been conducted on the topic. Unlike cementum thickness and hypercementosis, root and apex shape has not yet been related to patient age. A study of the precise difference between increased cementum thickness and hypercementosis is warranted. Hypercementosis refers to excessive cementum formation above and beyond the extent necessary to fulfill its normal functions, resulting in abnormal thickening with macroscopic changes in the tooth root, which may require the delivery of forces that are different from conventional mechanics in their intensity, direction and distribution. What are the unique features and specificities involved in moving teeth that present with hypercementosis? Bodily movements would be expected to occur, since inclination might prove difficult to achieve, but would the root resorption index be higher or lower?
Resumo:
O tratamento endodôntico de dentes com forame apical amplo requer consideração especial, devido ao risco de extravasamento do material obturador nos tecidos periapicais durante a obturação, de maneira relevante em áreas próximas às fissuras labiopalatinas. A criação de uma barreira apical é indicada em casos de difícil travamento do cone principal e consequente deficiência do selamento apical. O MTA em decorrência de suas excelentes propriedades biológicas, é o material de escolha para permanecer em contato com tecidos periodontais e periapicais, fazendo parte do arsenal endodôntico especificamente nestes casos de ápice aberto para a confecção de plug apical. Relato clínico: Indivíduo do gênero feminino, com fissura labiopalatina bilateral transforame, a distal dos dentes 11 e 21; compareceu no setor de endodontia do Hospital de Reabilitação de Anomalias Craniofaciais (HRAC-USP), apresentando necrose pulpar do dente 21. Na primeira sessão foi realizado o acesso cirúrgico, neutralização do conteúdo séptico/tóxico em sentido corono-apical, odontometria, biomecânica, curativo intracanal (pasta Calen) selamento provisório com cimento de ionômero de vidro. Na segunda sessão, foi realizada a obturação onde ocorreu extravasamento de material obturador, verificado através da radiografia comprobatória; justificando sua remoção e nova obturação, com prévia confecção de plug apical com MTA. Foi realizada proservação aos 6 meses pós tratamento endodôntico. Conclusão: neste caso, o plug apical com MTA possibilitou a obturação final do canal radicular com segurança, pela confecção de um anteparo apical, evitando extravasamento de material obturador e preservando a área de fissura labiopalatina.
Resumo:
Lo scopo di questa tesi è l'installazione di un Rilassometro ottenuto a partire da un magnete permanente situato nel Dipartimento di Fisica e Astronomia (DIFA - via Irnerio, 46), al fine di eseguire misure attendibili di Rilassometria in mezzi porosi su campioni del diametro di alcuni centimetri. Attualmente nel Dipartimento è gia presente un elettromagnete adibito a misure di questo tipo; tuttavia, questo strumento permette lo studio di campioni di piccole dimensioni (circa 220mm3) e si rivela insuffciente per lo studio di rocce, coralli e altre strutture porose di più grande dimensione senza la frantumazione del campione stesso; per questa ragione si è presentata la necessità dell'istallazione di una nuova strumentazione. Parte della strumentazione utilizzata è in disuso da parecchi anni e le caratteristiche devono essere verificate. Dopo l'assemblaggio della strumentazione (magnete, console, probe), sono state determinate le migliori condizioni in cui effettuare le misure, ovvero i parametri fondamentali dell'elettronica (frequenza di risonanza, TATT, tempo morto del probe, tempo di applicazione dell'impulso 90°) e la zona di maggiore uniformità del campo magnetico. Quindi, sono state effettuate misure di T1 e T2 su campioni bulk e su un campione di roccia saturata d'acqua, confrontando i risultati con valori di riferimento ottenuti tramite elettromagnete. I risultati ottenuti risultano consistenti con i valori attesi, con scarti - inevitabili a causa della grande differenza di volume dei campioni - molto ridotti, pertanto l'installazione del nuovo Rilassometro risulta essere completata con successo.
Resumo:
As the elastic response of cell membranes to mechanical stimuli plays a key role in various cellular processes, novel biophysical strategies to quantify the elasticity of native membranes under physiological conditions at a nanometer scale are gaining interest. In order to investigate the elastic response of apical membranes, elasticity maps of native membrane sheets, isolated from MDCK II (Madine Darby Canine kidney strain II) epithelial cells, were recorded by local indentation with an Atomic Force Microscope (AFM). To exclude the underlying substrate effect on membrane indentation, a highly ordered gold coated porous array with a pore diameter of 1.2 μm was used to support apical membranes. Overlays of fluorescence and AFM images show that intact apical membrane sheets are attached to poly-D-lysine coated porous substrate. Force indentation measurements reveal an extremely soft elastic membrane response if it is indented at the center of the pore in comparison to a hard repulsion on the adjacent rim used to define the exact contact point. A linear dependency of force versus indentation (-dF/dh) up to 100 nm penetration depth enabled us to define an apparent membrane spring constant (kapp) as the slope of a linear fit with a stiffness value of for native apical membrane in PBS. A correlation between fluorescence intensity and kapp is also reported. Time dependent hysteresis observed with native membranes is explained by a viscoelastic solid model of a spring connected to a Kelvin-Voight solid with a time constant of 0.04 s. No hysteresis was reported with chemically fixated membranes. A combined linear and non linear elastic response is suggested to relate the experimental data of force indentation curves to the elastic modulus and the membrane thickness. Membrane bending is the dominant contributor to linear elastic indentation at low loads, whereas stretching is the dominant contributor for non linear elastic response at higher loads. The membrane elastic response was controlled either by stiffening with chemical fixatives or by softening with F-actin disrupters. Overall, the presented setup is ideally suitable to study the interactions of the apical membrane with the underlying cytoskeleton by means of force indentation elasticity maps combined with fluorescence imaging.
Resumo:
This thesis presents a comparative developmental study of inflorescences and focuses on the production of the terminal flower (TF). Morphometric attributes of inflorescence meristems (IM) were obtained throughout the ontogeny of inflorescence buds with the aim of describing possible spatial constraints that could explain the failure in developing the TF. The study exposes the inflorescence ontogeny of 20 species from five families of the Eudicots (Berberidaceae, Papaveraceae-Fumarioideae, Rosaceae, Campanulaceae and Apiaceae) in which 745 buds of open (i.e. without TF) and closed (i.e. with TF) inflorescences were observed under the scanning electron microscope.rnThe study shows that TFs appear on IMs which are 2,75 (se = 0,38) times larger than the youngest lateral reproductive primordium. The shape of these IMs is characterized by a leaf arc (phyllotactic attribute) of 91,84° (se = 7,32) and a meristematic elevation of 27,93° (se = 5,42). IMs of open inflorescences show a significant lower relative surface, averaging 1,09 (se=0,26) times the youngest primordium size, which suggests their incapacity for producing TFs. The relative lower size of open IMs is either a condition throughout the complete ontogeny (‘open I’) or a result from the drastic reduction of the meristematic surface after flower segregation (‘open II’). rnIt is concluded that a suitable bulge configuration of the IM is a prerequisite for TF formation. Observations in the TF-facultative species Daucus carota support this view, as the absence of the TF in certain umbellets is correlated with a reduction of their IM dimensions. A review of literature regarding histological development of IMs and genetic regulation of inflorescences suggests that in ‘open I’ inflorescences, the histological composition and molecular activity at the tip of the IM could impede the TF differentiation. On the other side, in ‘open II’ inflorescences, the small final IM bulge could represent a spatial constraint that hinders the differentiation of the TF. The existence of two distinct kinds of ontogenies of open inflorescences suggests two ways in which the loss of the TF could have occurred in the course of evolution.rn
Resumo:
Valutazione della resistenza a taglio di un adesivo anaerobico forte, nel nostro caso Loctite 648, impiegato in un giunto albero-mozzo accoppiato per interferenza alla pressa al variare del rapporto lunghezza di accoppiamento su diametro di accoppiamento (L/D), nei casi in cui L/D valga 0,5, 1, 1,5 e 2.
Resumo:
I giunti ibridi sono impiegati in molte applicazioni meccaniche, avendo molti vantaggi, tra i quali quello di aumentare il carico trasferibile. Ci sono state ricerche in merito, le quali hanno valutato la dipendenza della resistenza a taglio di questi giunti rispetto a numerose variabili. Abbiamo poche informazioni, però, sulla dipendenza rispetto all'ER (Engagement Ratio, rapporto tra lunghezza e diametro di accoppiamento). Con questo lavoro la si vuole studiare nel caso di accoppiamenti con gioco in presenza di adesivo, considerando quattro livelli di ER. Per questo sono state effettuate prove di spiantaggio su pin e collar, dalle quali è risultata la presenza di una possibile dipendenza tra le due grandezze, seppur minima.
Resumo:
Studio dell'influenza del rapporto d'aspetto (lunghezza/diametro) sulla resistenza a taglio di un giunto incollato tramite adesivo epossidico in temperatura. Sono stati utilizzati quattro diversi rapporti d'aspetto e il materiale è un acciaio C40. Sono state eseguite prove di spiantaggio su diversi "pin" e "collar" e poi elaborati i dati con una metodologia statistica. La temperatura in questione è di 60 gradi e lo studio analizza se il rapporto d'aspetto ha influenza o meno sulla resistenza a taglio dell'adesivo epossidico.
Resumo:
I salumi fermentati sono prodotti caratterizzati da grandi differenze che riguardano la materia prima, gli ingredienti, le dimensioni e le condizioni di maturazione. Questa differenziazione è dovuta a pratiche storiche, culturali e tradizionali che variano da zona a zona. Il processo produttivo nel nostro Paese è però cambiato radicalmente grazie alle innovazioni tecnologiche. Tra queste l’introduzione delle colture starter ha rappresentato una garanzia di maggiore sicurezza igienica e sanitaria ma ha determinato una standardizzazione delle caratteristiche qualitative dei prodotti. Infatti, tutte le trasformazioni biochimiche che avvengono durante la maturazione possono essere influenzate dall’uso degli starter, così come dal diametro dei salami, che influenza la cinetica di perdita dell’acqua e la disponibilità di ossigeno all’interno del prodotto. Lo scopo del lavoro descritto nel mio elaborato è stato quello di valutare l’effetto di queste due variabili su alcune caratteristiche fisico-chimiche, microbiologiche e sul contenuto in amine biogene di salami prodotti industrialmente a partire dalla stessa miscela di ingredienti. Questo impasto carneo è stato addizionato di due starter diversi: oltre all’impiego di Staphylococcus carnosus, un primo lotto è stato inoculato con Lactobacillus sakei mentre un secondo con Pediococcus pentosaceus. Successivamente i due lotti sono stati insaccati in budelli sintetici aventi dimensioni diverse (grande con peso del prodotto all’insacco di 5.3kg e piccolo, con peso all’insacco di 385g). I risultati ottenuti da questa sperimentazione confermano il fatto che la dimensione è uno degli aspetti che maggiormente influenza la caratteristiche del prodotto. Inoltre, anche le colture starter hanno dato risultati diversi indipendentemente dal diametro, dimostrando la necessità di una più approfondita conoscenza tecnologica dei prodotti studiati in relazione alle attività microbiche che si svolgono durante la fermentazione e la maturazione.
Resumo:
INTRODUCTION: The aim of apical surgery is to hermetically seal the root canal system after root-end resection, thereby enabling periradicular healing. The objective of this nonrandomized prospective clinical study was to report results of 2 different root-end preparation and filling methods, ie, mineral trioxide aggregate (MTA) and an adhesive resin composite (Retroplast). METHODS: The study included 353 consecutive cases with endodontic lesions limited to the periapical area. Root-end cavities were prepared with sonic microtips and filled with MTA (n = 178), or alternatively, a shallow concavity was prepared in the cut root face, with subsequent placement of an adhesive resin composite (Retroplast) (n = 175). Patients were recalled after 1 year. Cases were defined as healed when no clinical signs or symptoms were present and radiographs demonstrated complete or incomplete (scar tissue) healing of previous radiolucencies. RESULTS: The overall rate of healed cases was 85.5%. MTA-treated teeth demonstrated a significantly (P = .003) higher rate of healed cases (91.3%) compared with Retroplast-treated teeth (79.5%). Within the MTA group, 89.5%-100% of cases were classified as healed, depending on the type of treated tooth. In contrast, more variable rates ranging from 66.7%-100% were found in the Retroplast group. In particular, mandibular premolars and molars demonstrated considerably lower rates of healed cases when treated with Retroplast. CONCLUSIONS: MTA can be recommended for root-end filling in apical surgery, irrespective of the type of treated tooth. Retroplast should be used with caution for root-end sealing in apical surgery of mandibular premolars and molars.
Resumo:
To compare the haemostatic effect and tissue reactions of different agents and methods used for haemorrhage control in apical surgery.
Resumo:
AIM: To describe a method of carrying out apical surgery of a maxillary molar using ultrasonics to create a lateral sinus window into the maxillary sinus and an endoscope to enhance visibility during surgery. SUMMARY: A 37-year-old female patient presented with tenderness to percussion of the maxillary second right molar. Root canal treatment had been undertaken, and the tooth restored with a metal-ceramic crown. Radiological examination revealed an apical radiolucency in close proximity to the maxillary sinus. Apical surgery of the molar was performed through the maxillary sinus, using ultrasonics for the osteotomy, creating a window in the lateral wall of the maxillary sinus. During surgery, the lining of the sinus was exposed and elevated without perforation. The root-end was resected using a round tungsten carbide drill, and the root-end cavity was prepared with ultrasonic retrotips. Root-end filling was accomplished with MTA(®) . An endoscope was used to examine the cut root face, the prepared cavity and the root-end filling. No intraoperative or postoperative complications were observed. At the 12-month follow-up, the tooth had no clinical signs or symptoms, and the radiograph demonstrated progressing resolution of the radiolucency. KEY LEARNING POINTS: When conventional root canal retreatment cannot be performed or has failed, apical surgery may be considered, even in maxillary molars with roots in close proximity to the maxillary sinus. Ultrasonic sinus window preparation allows more control and can minimize perforation of the sinus membrane when compared with conventional rotary drilling techniques. The endoscope enhances visibility during endodontic surgery, thus improving the quality of the case.