903 resultados para Curative Surgery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A transitory increase in blood pressure (BP) is observed following upper airway surgery for obstructive sleep apnea syndrome but the mechanisms implicated are not yet well understood. The objective of the present study was to evaluate changes in BP and heart rate (HR) and putative factors after uvulopalatopharyngoplasty and septoplasty in normotensive snorers. Patients (N = 10) were instrumented for 24-h ambulatory BP monitoring, nocturnal respiratory monitoring and urinary catecholamine level evaluation one day before surgery and on the day of surgery. The influence of postsurgery pain was prevented by analgesic therapy as confirmed using a visual analog scale of pain. Compared with preoperative values, there was a significant (P < 0.05) increase in nighttime but not daytime systolic BP (119 ± 5 vs 107 ± 3 mmHg), diastolic BP (72 ± 4 vs 67 ± 2 mmHg), HR (67 ± 4 vs 57 ± 2 bpm), respiratory disturbance index (RDI) characterized by apnea-hypopnea (30 ± 10 vs 13 ± 4 events/h of sleep) and norepinephrine levels (22.0 ± 4.7 vs 11.0 ± 1.3 µg l-1 12 h-1) after surgery. A positive correlation was found between individual variations of BP and individual variations of RDI (r = 0.81, P < 0.01) but not between BP or RDI and catecholamines. The visual analog scale of pain showed similar stress levels on the day before and after surgery (6.0 ± 0.8 vs 5.0 ± 0.9 cm, respectively). These data strongly suggest that the cardiovascular changes observed in patients who underwent uvulopalatopharyngoplasty and septoplasty were due to the increased postoperative RDI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laparoscopy is a surgical procedure on which operations in the abdomen are performed through small incisions using several specialized instruments. The laparoscopic surgery success greatly depends on surgeon skills and training. To achieve these technical high-standards, different apprenticeship methods have been developed, many based on in vivo training, an approach that involves high costs and complex setup procedures. This paper explores Virtual Reality (VR) simulation as an alternative for novice surgeons training. Even though several simulators are available on the market claiming successful training experiences, their use is extremely limited due to the economic costs involved. In this work, we present a low-cost laparoscopy simulator able to monitor and assist the trainee’s surgical movements. The developed prototype consists of a set of inexpensive sensors, namely an accelerometer, a gyroscope, a magnetometer and a flex sensor, attached to specific laparoscopic instruments. Our approach allows repeated assisted training of an exercise, without time constraints or additional costs, since no human artificial model is needed. A case study of our simulator applied to instrument manipulation practice (hand-eye coordination) is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sub adult Caretta caretta was found on the 23rd August, 2014 ca. 16 nautical miles south off S. Miguel Island, Azores (Northeast Atlantic), with a large pelagic trawl hook inside its mouth. The individual was kept in a basin of sea water and sent by boat to Terceira Island following instructions by the Azores Regional Government via the Environmental Authority in order to be examined by the author and, if possible, undergo the necessary hook removal procedures. In this note, we describe the surgical procedures and how the turtle was evaluated both pre- and post-surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 66-year-old female with Streptococcus viridans aortic and tricuspid infective endocarditis develops, during the course of antibiotic therapy, rupture of a right coronary sinus of Valsalva aneurysm to the right ventricle. An urgent cardiac surgery is preformed with implantation of a mechanical aortic prosthesis and a right coronary sinus plasty. Six months later a huge aortic pseudoaneurysm is diagnosed and she is submitted to a second uneventful surgery. A review is done for the significant features with discussion of diagnosis and therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Transthoracic echocardiography is the method of choice for the diagnosis of cardiac myxomas, but the transesophageal approach provides a better definition of the location and characteristics of the tumor. The authors review their thirteen years' experience on the echocardiographic diagnosis of this pathology. METHODS: From 1994 to 2007, 41 cardiac tumors were diagnosed in our echocardiographic laboratory, of which 27 (65.85%) were cardiac myxomas. The exams and the patients' clinical files were retrospectively reviewed. RESULTS: Of the 27 patients, 22 (81.5%) were female, with a mean age of 62.1 +/- 13.6 years (25-84 years). The predominant clinical features were due to the obstruction caused by the tumor in more than two thirds of the patients, followed by constitutional symptoms in one third and embolic events in 30%. In the lab results, anemia was found in three patients and elevated sedimentation rate and CRP in two. In two patients the myxoma was found by chance. All the cases were of the sporadic type, although we found a prevalence of thyroid disease of 14% (4 patients). All patients underwent urgent surgical resection except one, in whom surgery was refused due to advanced age and comorbidities. The myxomas followed a typical distribution with 24 (88.8%) located in the left atrium, 18 of them attached to the atrial septum (AS) and two to the mitral valve. In one patient, the tumor involved both atria. The other two cases originated in the right atrium at the AS. Embolic phenomena were more frequent in small tumors (p = 0.027) and in those with a villous appearance (p = 0.032). Obstructive manifestations were associated with larger tumors (p = 0.046) and larger left atria (p = 0.048). In our series, there were no deaths during hospitalization or in the follow-up period of 5.2 +/- 3.7 years in 19 patients. There were two recurrences, both patients being successfully reoperated. CONCLUSION: Myxoma is the most common cardiac tumor. Transesophageal echocardiography provides excellent morphologic definition, aiding in diagnosis and follow-up. Most clinical manifestations are obstructive and are associated with larger tumors. Small tumors with a friable appearance have a higher chance of embolization. Surgical resection is usually curative and the long-term prognosis is excellent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Surgery for congenital heart disease (CHD) has changed considerably during the last three decades. The results of primary repair have steadily improved, to allow treating almost all patients within the pediatric age; nonetheless an increasing population of adult patients requires surgical treatment. The objective of this study is to present the early surgical results of patients who require surgery for CHD in the adult population within a multicentered European study population. METHODS: Data relative to the hospital course of 2,012 adult patients (age > or = 18 years) who required surgical treatment for CHD from January 1, 1997 through December 31, 2004 were reviewed. Nineteen cardiothoracic centers from 13 European countries contributed to the data collection. RESULTS: Mean age at surgery was 34.4 +/- 14.53 years. Most of the operations were corrective procedures (1,509 patients, 75%), followed by reoperations (464 patients, 23.1%) and palliative procedures (39 patients, 1.9%). Six hundred forty-nine patients (32.2%) required surgical closure of an isolated ostium secundum atrial septal defect. Overall hospital mortality was 2%. Preoperative cyanosis, arrhythmias, and NYHA class III-IV, proved significant risk factors for hospital mortality. Follow-up data were available in 1,342 of 1,972 patients (68%) who were discharged home. Late deaths occurred in 6 patients (0.5%). Overall survival probability was 97% at 60 months, which is higher for corrective procedures (98.2%) if compared with reoperations (94.1%) and palliations (86.1%). CONCLUSIONS: Surgical treatment of CHD in adult patients, in specialized cardiac units, proved quite safe, beneficial, and low-risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Carotid body tumours (CBT) are neoplasms that develop from paragangionic cells of this structure. They are rare, with an estimated incidence of 1:30000 and can be associated with other neuro-endocrine neoplasia. The authors report their experience in the management of the disease, in the last 10 years. MATERIAL AND METHODS: Eight patients (with eight tumours) were treated, all submitted to tumour resection. 75% were female and the mean age was 56 years. We report a 12,5% incidence of neurological sequelae from surgery, and no mortality. In the follow-up (which varied between 1 and 10 years), no local or contralateral recurrence or metastasis were registered. Also, we did not found family cases of this disease. CONCLUSIONS: The authors noticed an unusually high proportion of female patients. The tumour resection was curative in all patients, with a rate of neurological complications inferior to that reported in other published series. These neurological sequelae were reported in patients with large tumours, thus reinforcing the outmost importance of an early diagnosis. Pre-operative selective embolization of these tumours can be helpful in the resection of large tumours, allowing a potential reduction in neurological complications.

Relevância:

20.00% 20.00%

Publicador: