968 resultados para Crack closure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is ample epidemiological and anecdotal evidence that a PFO increases the risk of stroke both in young and elderly patients, although only in a modest way: PFOs are more prevalent in patients with cryptogenic (unexplained) stroke than in healthy subjects, and are more prevalent in cryptogenic stroke than in strokes of other causes. Furthermore, multiple case series confirm an association of paradoxical embolism across a PFO in patients with deep vein thrombosis and/or pulmonary emboli.2. Is stroke recurrence risk in PFO-patients really not elevated when compared to PFO-free patients, as suggested by traditional observational studies? This finding is an epidemiological artifact called "the paradox of recurrence risk research" (Dahabreh & Kent, JAMA 2011) and is due to one (minor) risk factor, such as PFO, being wiped out by other, stronger risk factors in the control population.3. Having identified PFO as a risk factor for a first stroke and probably also for recurrences, we have to treat it, because treating risk factors always has paid off. No one would nowadays question the aggressive treatment of other risk factors of stroke such as hypertension, atrial fibrillation, smoking, or hyperlipidemia.4. In order to be effective, the preventive treatment has to control the risk factor (i.e. close effectively the PFO), and has to have little or no side effects. Both these conditions are now fulfilled thanks to increasing expertise of cardiologists with technically advanced closure devices and solid back up by multidisciplinary stroke teams.5. Closing a PFO does not dispense us from treating other stroke risk factors aggressively, given that these are cumulative with PFO.6. The most frequent reason why patients have a stroke recurrence after PFO closure is not that closure is ineffective, but that the initial stroke etiology is insufficiently investigated and not PFO related, and that the recurrence is due to another mechanism because of poor risk factor control.7. Similarly, the randomized CLOSURE study was negative because a) patients were included who had a low chance that their initial event was due to the PFO, b) patients were selected with a low chance that a PFO-related recurrence would occur, c) there was an unacceptable high rate of closure-related side effects, and d) the number of randomized patients was too small for a prevention trial.8. It is only a question of time until a sufficiently large randomized clinical trial with true PFO-related stroke patients and a high PFO-related recurrence risk will be performed and show the effectiveness of this closure9. PFO being a rather modest risk factor for stroke does not mean we should prevent our patients from getting the best available prevention by the best physicians in the best stroke centers Therefore, a PFO-closure performed by an excellent cardiologist following the recommendation of an expert neurovascular specialist after a thorough workup in a leading stroke center is one of the most effective stroke prevention treatments available in 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Infected postpneumonectomy chest cavities may be related to chronic postpneumonectomy empyema or arise in rare situations of necrotizing pneumonia with complete lung destruction where pneumonectomy and pleural debridement are required. We evaluated the safety and efficacy of an intrathoracic vacuum-assisted closure device (VAC) for the treatment of infected postpneumonectomy chest cavities. METHOD: A retrospective single institution review of all patients with infected postpneumonectomy chest cavities treated by VAC between 2005 and 2013. Patients underwent surgical debridement of the thoracic cavity, muscle flap closure of the bronchial stump when a fistula was present, and repeated intrathoracic VAC dressings until granulation tissue covered the entire chest cavity. After this, the cavity was obliterated by a Clagett procedure and closed. RESULTS: Twenty-one patients (14 men and 7 women) underwent VAC treatment of their infected postpneumonectomy chest cavity. Twelve patients presented with a chronic postpneumonectomy empyema (10 of them with a bronchopleural fistula) and 9 patients with an empyema occurring in the context of necrotizing pneumonia treated by pneumonectomy. In-hospital mortality was 23%. The median duration of VAC therapy was 23 days (range, 4-61 days) and the median number of VAC changes per patient was 6 (range, 2-14 days). Infection control and successful chest cavity closure was achieved in all surviving patients. One adverse VAC treatment-related event was identified (5%). CONCLUSIONS: The intrathoracic VAC application is a safe and efficient treatment of infected postpneumonectomy chest cavities and allows the preservation of chest wall integrity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To evaluate the very long-term risk of recurrent thromboembolic events in patients treated by percutaneous PFO closure. METHODS AND RESULTS: Between 1998 and 2008, a total of 232 consecutive patients with PFO and a high suspicion of paradoxical embolism were treated by percutaneous closure. The following major events were observed during hospitalisation: implantation failure (one patient) and appearance of an acute left-sided device thrombus requiring surgery (one patient). The primary endpoint of the study was a recurrent embolic event beyond at least five years' follow-up. During a mean follow-up of 7.6±2.4 years, this event occurred in five patients, representing a 0.28% annual/patient risk. Other major complications during follow-up were the following: late thrombus formation on the device (two patients) and transient atrial fibrillation (15 patients). Three patients died during follow-up from cardiovascular causes considered not related to the index procedure. The PFO was judged closed on follow-up echocardiography in 92.3% of patients. CONCLUSIONS: Long-term follow-up following percutaneous PFO closure for presumed paradoxical embolism reveals very low recurrence rates. This observation should be put in perspective with recent published randomised trials comparing percutaneous closure and medical therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines how plant closure affected individuals' careers and lives about two years after they lost their job. We analyze the displaced workers' reemployment prospects and study for reemployed workers the characteristics of their new jobs in terms of reemployment sectors, wages, and job quality. Additionally, we inquire how workers' sociability and subjective well-being were affected by job loss. Our analysis is based on our own survey conducted in Switzerland in 2011. The survey included the workforce of five manufacturing companies that had closed down two years earlier. We addressed the risk of biases typically prevailing with observational data by complementing it with register data from the public unemployment insurance. Moreover, we use a control group based on matched data from the Swiss Household Panel. We find that workers experience strongly diverging outcomes after plant closure: on the one hand, high proportions of the workers experience a smooth transition after plant closure. More than two-thirds of the workers returned to employment, more than half of them within less than six months. With respect to their social lives, we find that positive changes in relationships with their spouse, family and friends are more frequent than negative changes. On the other hand, for a small group of workers plant closure had a detrimental effect. Close to twenty percent remained unemployed. About ten percent of the workers were long-term unemployed and subsequently often were reemployed in jobs of lower quality. Unemployed workers and workers who dropped out of the labor force were particularly prone to find their subjective well-being decreasing. The most vulnerable subgroup in our study were workers over 55. This result stands in striking contrast to a large body of literature that considers labor market institutions to be primarily biased against young workers. Our findings show that older workers not only take longer to find a job but are also less likely to return to employment. Moreover, if they manage to find a job, they experience the severest cuts in wages and job quality of all cohorts. From a life-course perspective this result is remarkable since it shows that workers are not protected from hardship in their late careers. In light of the current demographic changes this finding may have important policy implications. -- Cette étude analyse l'impact des fermetures d'entreprises sur les travailleurs licenciés. Plus précisément, nous examinons les chances de réinsertion des travailleurs dans le marché du travail et - pour ceux qui l'ont fait avec succès - dans quels secteurs, pour quels salaires et avec quelle qualité d'emploi ils sont réengagés. Nous nous intéressons également aux répercussions engendrées par la perte de l'emploi sur la sociabilité et le bien-être subjectif des travailleurs concernés. Notre analyse se base sur les données d'une enquête que nous avons menée en 2011. Cette enquête cible le personnel de cinq entreprises industrielles suisses qui avaient fermé leurs portes deux ans auparavant. Pour dépasser les biais typiques liés aux données d'observation, nous utilisons en complément des données administratives issues de l'assurance chômage publique. De plus, nous utilisons un groupe de contrôle basé sur des données appariées provenant du Panel Suisse de Ménage. Nos analyses montrent des résultats fortement contrastés. D'un côté, la majeure partie des travailleurs ont vécu une transition professionnelle plutôt facile : plus des deux tiers des personnes ont retrouvé un travail et parmi elles plus de la moitié en moins de six mois. Par rapport aux relations sociales, tant avec leur partenaire, qu'avec les membres de leur famille et leurs amis, les changements expérimentés étaient plus fréquemment positifs que négatifs. De l'autre côté, cependant, pour une petite partie de travailleurs la fermeture de leur entreprise a eu des conséquences très négatives sur leur carrière et leur bien-être. Au moment de notre enquête, presque vingt pourcents des travailleurs étaient au chômage. Les personnes au chômage et celles qui avaient quitté le marché du travail ont été particulièrement affectées par une diminution de leur bien-être subjectif. Les plus vulnérables parmi les travailleurs licenciés étaient ceux qui étaient âgés de plus de 55 ans. Notre analyse montre que les travailleurs âgés ont beaucoup moins fréquemment retrouvé un travail. Pour les personnes de plus de 55 ans qui ont tout de même retrouvé un emploi, la réinsertion a durée plus longtemps, les pertes de salaire étaient plus conséquentes et la diminution de la qualité de l'emploi plus grande que pour les autres cohortes. Au vu des changements démographiques actuels, ce résultat interpellant peut avoir des implications politiques importantes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To predict the capacity of the structure or the point which is followed by instability, calculation of the critical crack size is important. Structures usually contain several cracks but not necessarily all of these cracks lead to failure or reach the critical size. So, defining the harmful cracks or the crack size which is the most leading one to failure provides criteria for structure’s capacity at elevated temperature. The scope of this thesis was to calculate fracture parameters like stress intensity factor, the J integral and plastic and ultimate capacity of the structure to estimate critical crack size for this specific structure. Several three dimensional (3D) simulations using finite element method by Ansys program and boundary element method by Frank 3D program were carried out to calculate fracture parameters and results with the aid of laboratory tests (loaddisplacement curve, the J resistance curve and yield or ultimate stress) leaded to extract critical size of the crack. Two types of the fracture which is usually affected by temperature, Elastic and Elasti-Plastic fractures were simulated by performing several linear elastic and nonlinear elastic analyses. Geometry details of the weldment; flank angle and toe radius were also studied independently to estimate the location of crack initiation and simulate stress field in early stages of crack extension in structure. In this work also overview of the structure’s capacity in room temperature (20 ºC) was studied. Comparison of the results in different temperature (20 ºC and -40 ºC) provides a threshold of the structure’s behavior within the defined range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: to present our experience with scheduled reoperations in 15 patients with intra-abdominal sepsis. METHODS: we have applied a more effective technique consisting of temporary abdominal closure with a nylon mesh sheet containing a zipper. We performed reoperations in the operating room under general anesthesia at an average interval of 84 hours. The revision consisted of debridement of necrotic material and vigorous lavage of the involved peritoneal area. The mean age of patients was 38.7 years (range, 15 to 72 years); 11 patients were male, and four were female. RESULTS: forty percent of infections were due to necrotizing pancreatitis. Sixty percent were due to perforation of the intestinal viscus secondary to inflammation, vascular occlusion or trauma. We performed a total of 48 reoperations, an average of 3.2 surgeries per patient. The mesh-zipper device was left in place for an average of 13 days. An intestinal ostomy was present adjacent to the zipper in four patients and did not present a problem for patient management. Mortality was 26.6%. No fistulas resulted from this technique. When intra-abdominal disease was under control, the mesh-zipper device was removed, and the fascia was closed in all patients. In three patients, the wound was closed primarily, and in 12 it was allowed to close by secondary intent. Two patients developed hernia; one was incisional and one was in the drain incision. CONCLUSION: the planned reoperation for manual lavage and debridement of the abdomen through a nylon mesh-zipper combination was rapid, simple, and well-tolerated. It permitted effective management of severe septic peritonitis, easy wound care and primary closure of the abdominal wall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: to verify the effectiveness of the rubber elastic band in the treatment of large wounds of the body wall of rabbits by means of traction of its edges. METHODS: we studied 30 New Zealand rabbits, divided into three groups (n=10): Group 1- healing by secondary intention; Group 2- removal and eutopic repositioning of skin as full thickness skin graft; Group 3- Approximation of wound edges with elastic rubber band. In all animals, we removed a segment of the back skin and subcutaneous tissue down to the fascia, in accordance with an acrylic mold of 8cm long by 12cm wide. All animals were observed for 21 days. RESULTS: two animals of groups 1 and 2 had wound abscess. In Group 2, there was partial or total graft loss in 90% of animals. The complete closure of the wounds was observed in four animals of Group 1, six of Group 2 and eight of Group 3. There was no difference between the scar resistance values of groups 2 and 3, which were higher than those in Group 1. The scars of the three groups were characterized by the presence of mature connective tissue mixed with blood vessels and inflammatory infiltration, predominantly polymorphonuclear. CONCLUSION: the tensile strength of the wound edges with rubber elastic band is as efficient as the skin graft to treat rabbits' large body wounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Postharvest lettuce often lose water, thus affecting both its market value and consumer acceptance. However, the mechanism of the water-loss is still waiting well exploration. The aim of the present study was to investigate the effect of a foliar application of ABA on the fresh weight-loss and the chlorophyll content of postharvest lettuce as well as its association with the regulation of stomata. The present data demonstrated that exogenously application of ABA, in a concentration range of 0 to 100 µM, significantly lowered the fresh weight-loss of postharvest lettuce. ABA also delayed chlorophyll reduction during ambient storage, but this protective effect was ABA concentration-dependent. Among the tested ABA concentrations, 50 µM or lower ABA produced an inhibition effect on chlorophyll degradation in postharvest lettuce leaves. The results demonstrated that the exogenous ABA treatment can obviously reduce the transpiration rate of lettuce leaves by promoting the stomatal closure of postharvest lettuce, therefore eventually delay fresh weight-loss. The present study primarily showed that the application of exogenous ABA, which originated from a naturally-produced phytohormone, has a great potential in retaining the freshness of postharvest lettuce that is stored in an ambient condition, although possible practical application still need to be further evaluated.