921 resultados para Corneal hysteresis
Resumo:
Purpose: To describe corneal graft survival and visual outcome after therapeutic penetrating keratoplasty in patients with Acanthamoeba keratitis (AK) that is unresponsive to clinical treatment. Methods: Retrospective study. Thirty-two patients with AK who underwent therapeutic penetrating keratoplasty (tPK) from August 1996 to August 2005 were included. Data relating to clinical features, visual acuity, surgical technique, graft survival and complications were collected. Graft survival was evaluated by the Kaplan-Meier method and comparisons were performed using the Log-rank test. Results: Most patients (62.5%) were female. Mean age [+/- standard deviation (SD)] was 35 (+/- 13) years (range 15-68 years). All patients were contact lens wearers. Eighteen patients (56%) presented paralytic mydriasis and glaucoma during the treatment. Thirteen patients (40%) developed glaucoma after surgery; eight of them (61%) required a second PK because of graft failure. Of the 32 keratoplasty eyes, 56.2% presented graft failure at any follow-up point. Forty-five per cent of graft failures occurred before the 12 month follow-up, so 55% remained clear in the first year after surgery. Twelve patients underwent a second PK; seven of them failed and 45% were clear at 1 year. Two patients presented graft recurrence of amoebic infection. There was no significant difference in graft survival when eyes with or without mydriasis were compared (P = 0.40). Eyes with glaucoma presented a significantly shorter graft survival (P = 0.01). Conclusion: Penetrating keratoplasty is a treatment option for eyes that are unresponsive to clinical treatment infections. However, graft survival is poor; postoperative glaucoma is frequent and is associated with shorter graft survival.
Resumo:
The hysteretic behavior of mechanically alloyed nanocomposites FeCo + MnO was studied at high temperatures. These composites present an unusual high and thermally stable coercivity, compared to FeCo milled at equal conditions. Coercivity enhancement was observed in hysteresis loops obtained between room temperature and 750 K. It is attributed to the isolation of the FeCo ferromagnetic particles by the paramagnetic MnO (T(N) = 120 K). The M(rev)(M(irr))(H) curves are clearly linear for the composite, indicating that coherent rotation is the reversal mechanism in these materials. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Magnetic properties of nanocrystalline NiFe(2)O(4) spinel mechanically processed for 350 h have been studied using temperature dependent from both zero-field and in-field (57)Fe Mossbauer spectrometry and magnetization measurements. The hyperfine structure allows us to distinguish two main magnetic contributions: one attributed to the crystalline grain core, which has magnetic properties similar to the NiFe(2)O(4) spinel-like structure (n-NiFe(2)O(4)) and the other one due to the disordered grain boundary region, which presents topological and chemical disorder features(d-NiFe(2)O(4)). Mossbauer spectrometry determines a large fraction for the d-NiFe(2)O(4) region(62% of total area) and also suggests a speromagnet-like structure for it. Under applied magnetic field, the n-NiFe(2)O(4) spins are canted with angle dependent on the applied field magnitude. Mossbauer data also show that even under 120 kOe no magnetic saturation is observed for the two magnetic phases. In addition, the hysteresis loops, recorded for scan field of 50 kOe, are shifted in both field and magnetization axes, for temperatures below about 50 K. The hysteresis loop shifts may be due to two main contributions: the exchange bias field at the d-NiFe(2)O(4)/n-NiFe(2)O(4) interfaces and the minor loop effect caused by a high magnetic anisotropy of the d-NiFe(2)O(4) phase. It has also been shown that the spin configuration of the spin-glass like phase is modified by the consecutive field cycles, consequently the n-NiFe(2)O(4)/d-NiFe(2)O(4) magnetic interaction is also affected in this process. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The article suggests a new test for strong hysteresis in international trade. The variables that capture the effects of hysteresis are based on the model of Dixit (1989) with calibrations using a state-space model to determine the parameters for each point in time. These variables are then applied to a cointegration test with breaks, where it is possible to verify whether the hysteresis effect is essential in determining the long-term equilibrium.
Resumo:
Esta dissertação tem dois objetivos: (i) propor um novo teste para verificar a existência de hysteresis em comércio exterior; (ii) aplicá-lo para o Brasil e analisar o comportamento recente do setor externo deste país à luz desta teoria. O teste sugerido envolve duas etapas. A primeira é a de delimitação da zona de inação ao longo do tempo, utilizando calibrações para o modelo de Dixit (1989, 1994) combinadas com uma aplicação de um modelo de Estado-Espaço de coeficientes variando no tempo para estimar o movimento browniano da taxa de câmbio real com parâmetros variáveis no tempo. Esta etapa nos permitirá identificar, de acordo com a teoria de hysteresis, quando a taxa de câmbio real ultrapassou os limiares da zona de inação. A segunda etapa consiste em utilizar estes resultados, juntamente com a metodologia de análise de cointegração com quebra estrutural proposto por Johansen et al. (2000), para testar a hipótese de que variações temporárias no câmbio, desde que sejam suficientemente grandes para ultrapassar os limiares da zona de inação, afetam permanentemente as exportações. Os resultados encontrados não apresentaram evidências fortes de hysteresis para o volume total das exportações brasileiras, mas sugeriram que há alguma evidência de hysteresis para o volume das exportações de produtos manufaturados.
Resumo:
This article investigates the hypothesis of hysteresis for the Brazilian manufactured exports and imports in recent years. For that it was used an empirical measure of strong hysteresis (macroeconomic) developed by Piscitelli et al. (2000) and tested its significance in sectoral supply and demand equations for exports and in sectoral equations for import demand. The results shows that Brazilian manufactured exports are strongly determined by international demand, being the empirical measure of real exchange rate expressed by the ratio between international prices and export prices nationals the relevant measure to explain the export performance. With respect to the hysteresis hypothesis, it was rejected for the aggregate of manufactures exports, but accepted in some industrial sectors. For imports this hypothesis was accepted for aggregate of manufactured imports and for ten industrial sectors.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O endotélio corneal é uma monocamada de células poligonais. A integridade e saúde dessa camada são essenciais para a manutenção da transparência corneal normal. Este estudo reportou pela primeira vez, de forma detalhada, a morfologia ultra-estrutural e a morfometria do endotélio corneal de suínos adultos mestiços à microscopia eletrônica de varredura (MEV). A superfície endothelial corneal apresentou um padrão regular de células poligonais, com predomínio da forma hexagonal e de bordas celulares nítidas. O núcleo foi observado como protuberância arredondada no centro da célula. Também foram observados os cílios (2-4) em apenas algumas células da região periférica da córnea, as aberturas das vesículas pinocitóticas na proximidade dos cílios, as microvilosidades, as varas da borda e as bordas celulares em formato de zigzag. A área celular média foi significativamente maior (P<0,05) no centro da córnea do que na periferia, com um coeficiente de variação menor no centro da córnea. A densidade celular média foi significativamente maior na periferia (P<0,05) e 43,9% maior que os dados reportados por outros autores na microscopia especular, o que demonstra o efeito da retração celular durante o processamento das amostras. O valor médio do número de lados das células (pleomorfismo) foi de 5,9, o que evidencia um predomínio do formato hexagonal. A percentagem de células hexagonais foi significativamente maior no centro (P<0,001). Os parâmetros obtidos nesta pesquisa servirão de base para estudos futuros sobre o efeito de medicamentos, cirurgias intracamerulares ou soluções para armazenamento de córneas para transplantes no endotélio corneal do suíno.
Resumo:
The play operator has a fundamental importance in the theory of hysteresis. It was studied in various settings as shown by P. Krejci and Ph. Laurencot in 2002. In that work it was considered the Young integral in the frame of Hilbert spaces. Here we study the play in the frame of the regulated functions (that is: the ones having only discontinuities of the first kind) on a general time scale T (that is: with T being a nonempty closed set of real numbers) with values in a Banach space. We will be showing that the dual space in this case will be defined as the space of operators of bounded semivariation if we consider as the bilinearity pairing the Cauchy-Stieltjes integral on time scales.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
PURPOSE. Amniotic membrane transplantation (AMT) has been used as a graft or as a dressing in ocular surface reconstruction, facilitating epithelization, maintaining normal epithelial phenotype, and reducing inflammation, vascularization, and scarring. The corneal transparency is due, at least in part, to the arrangement in orthogonal lamellae of collagen fibrils, surrounded by proteoglycans (PGs). These PGs regulate fibrilogenesis, the matrix assembly, and ultimately the corneal transparency. The purpose of the present study was to investigate the effects of AMT upon the corneal PGs after severe limbal injury.METHODS. Experiments were performed on the right corneas of 22 New Zealand female albino rabbits, and their left corneas were used as matched controls. These animals were divided into 3 groups: G1 (n = 10): total peritomy and keratolimbectomy, followed by application of 0.5 M NaOH; G2 (n = 10): submitted to the same trauma as G1, and treated by AMT; G3: no trauma, only AMT (n = 2). The right corneas of G2 and G3 were covered by DMSO 4 cryopreserved human amniotic membrane, fixed by interrupted 9-0 mononylon sutures, with its stromal face toward the ocular surface. After 7 or 30 days, the corneas were removed and PGs were extracted.RESULTS. Normal corneas contained approximately 9 mg of PGs per gram of dry tissue. AMT on intact cornea (G3) did not cause any changes in the concentration of PGs. In contrast, injured corneas contained much less PGs, both on the seventh and on the 30th day posttrauma. The PG concentration was even lower in injured corneas treated by AMT. This decrease was due almost exclusively to dermatan sulfate PGs, and the structure of dermatan sulfate was also modified, indicating changes in the biosynthesis patterns.CONCLUSIONS. Although beneficial effects have been observed on clinical observation and concentration of soluble proteins after AMT, the normal PG composition of cornea was not attained, even 30 days postinjury, indicating that the normal ocular surface reconstruction, if possible, is a long-term process. (Eur J Ophthalmol 2010; 20: 290-9)
Resumo:
Purpose: To investigate the proliferative behavior of the corneal and limbal epithelia after debridement on the central region of the rabbit cornea. Methods: After scraping a circular epithelial area, 5 mm in diameter, in the center of the cornea, (3)H-thymidine ((3)H-TdR) was injected intravitreally, and the rabbits killed from 1 to 49 days afterward. The cornea, together with the adjacent conjunctiva, was processed for autoradiography. Results: The regenerating epithelium at the center of the cornea exhibited high frequencies of labeled nuclei when compared to controls. The mitotic indexes for the limbus were comparable in experimental and control eyes. The unique basal stratum of the limbal epithelium exhibited quick proliferation and vertical migration in all eyes. Cells that remained labeled for four weeks or more were observed throughout the corneal epithelium, including its basal stratum, and this did not depend on epithelial damage. Conclusion: Corneal epithelium wounds are healed by sliding and proliferation of cells surrounding the epithelial gap without any evidence for the participation of the limbal epithelium. Daughter cells labeled with (3)H-TdR were visualized in all layers of the corneal epithelium up to 7 weeks after the DNA precursor injection. However, at this long interval, the only labeled cells in the limbus were in the suprabasal layers.
Resumo:
Background Damage to the corneal epithelium causes not only a reaction for its repair but also affects other parts of the cornea as well as different components of the anterior segment of the eye. The purpose of this investigation was to analyze the consequences, following epithelial and limbal damage, to the iris of rabbits (Oryctolagus cuniculus).Methods The corneal epithelium was thoroughly scraped followed by surgical excision of the limbus. Next, (3)H-thymidine ((3)H-TdR) was injected intravitreally both into the right (experimental) and left (control) eyes which had their anterior segments processed for autoradiography at intervals of 2, 7 and 21 days after surgery (three rabbits per interval). The irises were also examined with scanning-electron and confocal microscopy after Evans blue injection.Results There was a high frequency of labeling in the cells of the iris blood vessels in the experimental eye, particularly the endothelial ones. The ratio of labeled cells between experimental and control irises was 40:1, with a population of nuclei increasing by 25% and remaining labeled up to 21 days. There was also an increase in the volume of the iris vasculature as shown by confocal microscopy. The high labeling frequencies of the vascular cells were observed throughout the iris from the ciliary to the pupillary regions.Conclusions The lesions on the corneal epithelium elicit proliferation of the iris vascular cells, mainly its endothelium, as well as an early breakdown of the blood-aqueous barrier. The daughter cells resulting from the damage to the eye surface were detected up to 21 days after a single injection of (3)H-TdR, most likely due to their slow turnover. As a consequence of this proliferation, the vasculature of the iris increased in volume.
Resumo:
The investigation was centered on the morphological features of the conjunctiva-cornea transition (limbus) of the rabbit eye and the proliferative behavior of its epithelium. The eyes were processed for examination with light and electron microscopy, as well as for autoradiography after intravitreal injection of [H-3]thymidine ([H-3]TdR). At the sites of extraocular muscle insertion, the vascularization of the stroma extended to the peripheral cornea, and the limbal epithelium was thin with its basal stratum made up by clear cuboidal cells. In between the muscle insertions, the cuboidal clear cells, as well as the stroma blood vessels; were scarce. At the light microscope level, the basement membrane was distinct in the cornea but not in the limbus or the conjunctiva. Autoradiographs demonstrated that, at the limbus, the basal cells migrated very quickly to the suprabasal region and remained there up to the 28-day interval. Labeled cells were identified in all epithelial layers of the cornea, including the basal one, at 21 and 28 days but not in the limbal basal clear cells. The rate of renewal of conjunctival epithelium was similar to that observed for the transition with scarce clear cells. The high-resolution autoradiographs demonstrated that the basal cuboidal clear limbal cells exhibit a quick renewal and that they are not label-retaining cells. These latter ones were detected all over the corneal epithelium and in the suprabasal layers of the limbus up to 28 days, in physiological conditions, without the need of stimulation by damage to the corneal epithelium.