956 resultados para Conventional water treatment
Resumo:
With the growth and development of modern society, arises the need to search for new raw materials and new technologies which present the "clean" characteristic, and do not harm the environment, but can join the energy needs of industry and transportation. The Moringa oleifera Lam, plant originating from India, and currently present in the Brazilian Northeast, presents itself as a multi-purpose plant, can be used as a coagulant in water treatment, as a natural remedy and as a feedstock for biodiesel production. In this work, Moringa has been used as a raw material for studies on the extraction and subsequently in the synthesis of biodiesel. Studies have been conducted on various techniques of Moringa oil extraction (solvents, mechanical pressing and enzymatic), being specially developed an experimental design for the aqueous extraction with the aid of the enzyme Neutrase© 0.8 L, with the aim of analyzing the influence variable pH (5.5-7.5), temperature (45-55°C), time (16-24 hours) and amount of catalyst (2-5%) on the extraction yield. In relation to study of the synthesis of biodiesel was initially carried out a conventional transesterification (50°C, KOH as a catalyst, methanol and 60 minutes reaction). Next, a study was conducted using the technique of in situ transesterification by using an experimental design variables as temperature (30-60°C), catalyst amount (2-5%), and molar ratio oil / ethanol (1:420-1:600). The extraction technique that achieved the highest extraction yield (35%) was the one that used hexane as a solvent. The extraction using 32% ethanol obtained by mechanical pressing and extraction reached 25% yield. For the enzymatic extraction, the experimental design indicated that the extraction yield was most affected by the effect of the combination of temperature and time. The maximum yield obtained in this extraction was 16%. After the step of obtaining the oil was accomplished the synthesis of biodiesel by the conventional method and the in situ technique. The method of conventional transesterification was obtained a content of 100% and esters by in situ technique was also obtained in 100% in the experimental point 7, with a molar ratio oil / alcohol 1:420, Temperature 60°C in 5% weight KOH with the reaction time of 1.5 h. By the experimental design, it was found that the variable that most influenced the ester content was late the percentage of catalyst. By physico-chemical analysis it was observed that the biodiesel produced by the in situ method fell within the rules of the ANP, therefore this technique feasible, because does not require the preliminary stage of oil extraction and achieves high levels of esters
Resumo:
Textile industry deals with a high diversity of processes and generation of wastewaters with a high content of pollutant material. Before being disposed of in water bodies, a pre-treatment of the effluent is carried out, which is sometimes ineffective. In order to be properly treated, physical and chemical properties of the effluent must be known, as well as the pollutant agents that might be present in it. This has turned out to be a great problem in the textile industry, for there is a variety of processes and the pollutant load is very diversified. The characterization of the effluent allows the identification of most critical points and, as a consequence, the most appropriate treatment procedure to be employed, may be chosen. This study presents the results obtained after characterizing the effluent of a textile industry that comprises knitting, dyeing and apparel sections, processing mainly polyester/cotton articles. In this work, twenty samples of the effluent were collected, and related to the changes in production. From the results, a statistical evaluation was applied, determined in function of the rate of flow. The following properties and pollutants agents were quantitatively analysed: temperature; pH; sulfides; chlorine; alcalinity; chlorides; cianides; phenols; color; COD (Chemical Oxygen Demand); TOC (Total Organic Carbon); oil and grease; total, fixed and volatile solids; dissolved, fixed and volatile solids; suspended, fixed and volatile solids; setteable solids and heavy metals such as cadmium, copper, lead, chromium, tin, iron, zinc and nickel. Analyses were carried out according to ABNT NBR 13402 norm, based upon Standard Methods for the Examination of Water and Wastewater. As a consequence, a global treatment proposal is presented, involving clean production practices as contaminant load reducer, followed by conventional (biological) treatment
Resumo:
Effluent color resulting from textile dyeing processes has been one of the biggest environmental problems faced by the textile industry. In particular, reactive dyes are highly resistant to conventional wastewater treatment methods. New technologies have been contemplated, some of which have been applied in industrial treatment plants, but color removal has not been efficiently attained. Since microemulsion systems provide good results in heavy metals and proteins extraction processes, their use in dyes extraction has been suggested and investigated. In this work, a real textile wastewater from an exhaustion dyebath has been treated, which contains the following reactive dyes: Procion Yellow H-E4R (CI Reactive Yellow 84), Procion Blue H-ERD (CI Reactive Blue 160) and Procion Red H-E3B (CI Reactive Red 120), in addition to auxiliary compounds normally found in dyeing processes with reactive dyes. The dyes Remazol Blue RR and Remazol Turquoise Blue G (Reactive Blue 21) have also been examined in view of the presence of heavy metals in these molecules. The microemulsion system comprised dodecyl ammonium chloride (as a cationic surfactant), water or wastewater as aqueous phase, kerosene as oil phase, and one of the following alcohols as cosurfactant: isoamyl alcohol, n-butyl alcohol and n-octyl alcohol. The pseudo-ternary diagrams were constructed in order to define Winsor s equilibrium regions. The influence of parameters such as pH, C/S (cosurfactant/surfactant) ratio, distribution coefficient, initial dye concentration, salinity, temperature, phases relative amounts, loading capacity of the microemulsion phase and dye reextraction rate has also been investigated. An experimental planning (Scheffé Net) was used to optimize the extraction process. The removal of color and metals reached levels as high as 99%
Resumo:
In the state of Rio Grande do Norte (RN), Brazil, there are about 80 sewage treatment systems being the predominant technology waste stabilization ponds. The Baldo s WWTP , due to its location and low availability of area, was designed as a hybrid conventional system (UASB reactor followed by activated sludge with biodiscs) at a tertiary level, being the most advanced WWTP in the State and also with the larger treatment capacity (1620 m3/h) .The paper presents the results of its performance based on samples collections from May to December 2012. Composite samples of the effluent of the grit chamber, UASB reactors, anoxic chambers, aeration tanks and treated effluent were collected weekly, every 4 hours for 24 hours. The results showed that the WWTP effluent presented adequate ranges of temperatures, pH and DO, however removal efficiencies of BOD and TSS were below the predicted by design. The UASB reactors also showed removals of BOD and TSS less than expected, due to the accumulation of sludge in the reactors, which eventually, was washed out in the effluent. The nitrification process was not satisfactory mainly due to problems in the oxygen distribution in the aeration tanks. The removal of ammonia and TKN were high, probably by the assimilation process
Resumo:
Recently a textile azo dye processing plant effluent was identified as one of the sources of mutagenic activity detected in the Cristais River, a drinking water source in Brazil [G.A. Umbuzeiro, D.A. Roubicek, C.M. Rech, M.I.Z. Sato, L.D. Claxton, Investigating the sources of the mutagenic activity found in a river using the Salmonella assay and different water extraction procedures, Chemosphere 54 (2004) 1589-1597]. Besides presenting high mutagenic activity in the Salmonella/microsome assay, the mutagenic nitro-aminoazobenzenes dyes CI Disperse Blue 373, Cl Disperse Violet 93, and CI Disperse Orange 37 [G.A. Umbuzeiro, H.S. Freeman, S.H. Warren, D.P Oliveira, Y. Terao, T. Watanabe, L.D. Claxton, the contribution of azo dyes in the mutagenic activity of the Cristais river, Chemosphere 60 (2005) 55-64] as well as benzidine, a known carcinogenic compound [T.M. Mazzo, A.A. Saczk, G.A. Umbuzeiro, M.V.B. Zanoni, Analysis of aromatic amines in surface waters receiving wastewater from textile industry by liquid chromatographic with eletrochemical detection, Anal. Lett., in press] were found in this effluent. After similar to 6 km from the discharge of this effluent, a drinking water treatment plant treats and distributes the water to a population of approximate 60,000. As shown previously, the mutagens in the DWTP intake water are not completely removed by the treatment. The water used for human consumption presented mutagenic activity related to nitro-aromatics and aromatic amines compounds probably derived from the cited textile processing plant effluent discharge [G.A. Umbuzeiro, D.A. Roubicek, C.M. Rech, M.I.Z.. Sato, L.D. Claxton, Investigating the sources of the mutagenic activity found in a river using the Salmonella assay and different water extraction procedures, Chemosphere 54 (2004) 1589-1597; G.A. Umbuzeiro, H.S. Freeman, S.H. Warren, D.P. Oliveira, Y. Terao, T. Watanabe, L.D. Claxton, the contribution of azo dyes in the multagenic activity of the Cristais river, Chemosphere 60 (2005) 55-64]. Therefore, it is important to evaluate the possible risks involved in the human consumption of this contaminated water. With that objective, one sample of the cited industrial effluent was tested for carcinogenicity in the aberrant crypt foci medium-term assay in colon of Wistar rats. The rats received the effluent in natura through drinking water at concentrations of 0.1%, 1%, and 10%. The effluent mutagenicity was also confirmed in the Salmonella/microsome assay with the strains TA98 and YG1041. There was an increased number of preneoplastic lesions in the colon of rats exposed to concentrations of 1% and 10% of the effluent, and a positive response for both Salmonella strains tested. These results indicate that the discharge of the effluent should be avoided in waters used for human consumption and show the sensitivity of the ACF crypt foci assay as an important tool to evaluate the carcinogenic potential of environmental complex mixtures. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Water treatment uses chlorine for disinfection causing formation of trihalomethanes. In this work, an electrolytic water pre-treatment was studied and applied to the water from a fountainhead. The action against microorganisms was evaluated using cast-iron and aluminum electrodes. Assays were made in laboratory using the electrolytic treatment. After 5 min of electrolysis the heterotrophic bacteria count was below 500 cfu/mL and complete elimination of total and fecal coliforms was observed. Using electrolytic treatment as a pretreatment of conventional tap water treatment is proposed.
Resumo:
Estudou-se o reuso de água de um sistema composto por estação de tratamento de esgoto (ETE) com aeração prolongada e lodo ativado, e em uma estação compacta de tratamento de água (ECTA) de uma indústria metalúrgica. Os processos para obtenção da água de reuso foram: microbiológico e físico-químico. O esgoto doméstico foi bombeado para a ETE, onde houve formação de flocos biológicos e água clarificada. Avaliou-se a eficiência do processo microbiológico da ETE mediante a remoção de demanda bioquímica de oxigênio (DBO), demanda química de oxigênio (DQO) e sólidos sedimentáveis (SS). A eficiência do processo físico-químico de clarificação e desinfecção foi avaliada mediante análises de pH, turbidez, cor, contagem de bactérias heterotróficas aeróbias, cloro livre, dureza, alcalinidade, cloretos, sulfatos, sólidos totais dissolvidos (STD). Na água de reuso além desses parâmetros avaliou-se a toxicidade aguda ao microcrustáceo Daphnia similis.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The work reported here involved the characterization of sludges produced at water treatment plants in Jaboticabal-SP using FeCl3 as flocculant, and in Taquaritinga-SP and Manaus-AM using Al2(SO4)3 as flocculant. An evaluation was also made of the interaction of organic matter extracted from the sludges with different metal species. The results indicated that all the sludges produced at water treatment plants have an important agricultural potential and that their use depends on the characteristics of the raw water and the type of flocculant employed in conventional treatment. The humic substances extracted from the sludges showed different affinities for metal species, favoring eventual exchanges between potentially toxic metals and macro- and micronutrients. An alternative for the use of sludge in agriculture is to pretreat it to remove potentially toxic metals and enrich it with micro- and macronutrients that can be released to the plant.
Resumo:
O objetivo do presente artigo é investigar a relação fluorose/cáries em escolas, de acordo com o nível de fluoreto no abastecimento público de água. A amostra consistiu em 360 alunos de doze anos de idade, de ambos os sexos, que frequentam as escolas próximas da região em que nasceram. As escolas foram classificadas em três grupos de acordo com a presença de fluoreto no abastecimento de água: 1) fluoretação na Estação de Tratamento de Água (ETA); 2) fluoretação direta em poços; e 3) áreas não fluoretadas (ANF). Os testes deχe de Goodman (significância = 5%) foram utilizados para avaliar a associação entre a origem da água e o grau de fluorose. Os resultados mais predominantes foram presença de cáries em toda a amostra (P<0,05); ausência de fluorose em ambos gêneros, para indivíduos brancos e aqueles vivendo em áreas abastecidas com água fluoretada diretamente de poços e não fluoretadas (P<0,05). Não houve diferença no grau de severidade da fluorose entre as fontes de abastecimento de água (P>0,05). As cáries ainda são uma importante questão nessa população, apesar do estabelecimento de medida preventiva. A observação da fluorose em alunos vivendo em áreas não fluoretadas confirma a presença de outras fontes de fluorose.
Resumo:
The water produced by the Cristais River Drinking Water Treatment Plant (CR-DWTP) repeatedly produced mutagenic responses that could not be explained by the presence of disinfection byproducts (DBPs) generated by the reaction of humic acids and chlorine. In order to determine the possible role of chlorinated dye products in this mutagenic activity, solutions of a black dye commercial product (BDCP) composed of C. I. Disperse Blue 373, C. I. Disperse Orange 37, C. I. Disperse Violet 93, and chemically reduced BDCP (R-BDCP) were chlorinated in a manner similar to that used by the CR-DWTP. The resulting solutions were extracted with XAD-4 along with one drinking water sample collected from the CR-DWTP. All extracts showed mutagenic activity in the Salmonella/microsome assay. Dye components of the BDCP as well as its reduced chlorinated (Cl-R-BDCP) derivative were detected in the drinking water sample by analysis with a high performance liquid chromatography/diode array detector (HPLC/DAD). The mutagenicity results of these products suggest that they are, at least in part, accounting for the mutagenic activity detected in the drinking water samples from the Cristais River. The data obtained in this study have environmental and health implications because the chlorination of the BDCP and the R-BDCP leads to the formation of mutagenic compounds (Cl-BDCP and Cl-R-BDCP), which are potentially important disinfection byproducts that can contaminate the drinking water as well as the environment.
Resumo:
Presented here is a study about the capability of a sensing unit to detect changes in river water quality. In order to determine its accuracy, water quality was monitored at 11 points along the Veado River in Presidente Prudente, Brazil. To have a basis for comparison, a water quality index (WQI) was developed following methods previously applied in different watersheds. Results showed an accurate relationship between WQI and electric impedance readings detected by the sensing unit. Principal components analysis (PCA) was used to derive results in a form that can be correlated with WQI calculated for each sample point, which showed the potential application of this device.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Differences in culture duration, metamorphosis rate and the productivity in hatchery culture of M. rosenbergii using a closed system with natural and artificial brackish water were evaluated. Reuse of brackish water in more than one hatchery cycle was also evaluated. Natural and artificial brackish water constituted the two tested treatments, which were distributed in four independent recirculating systems (tank and respective biofilter). Four batches of cultures were conducted and the 2nd and 4th reused the water from the 1st and 3rd, respectively. Mean duration of the hatchery period was 28 d in natural brackish water and 31 d in artificial brackish water. The metamorphosis rate and the average productivity for the natural brackish water treatment were 74% and 60 postlarvae/ L. respectively, and values obtained with artificial brackish water were 55% and 44 postlarvae/L. The successful hatchery culture of M. rosenbergii in this specific artificial brackish water suggests its potential use in enterprises located far from the coast. Brackish water can be used in two consecutive cultures without a negative effect on productivity.