937 resultados para Control algorithm


Relevância:

60.00% 60.00%

Publicador:

Resumo:

在核酸扩增反应仪中,基因芯片核酸扩增反应过程要求实现温度高精度快速跟踪控制,常规温控方案和算法难以实现。将模糊推理系统与常规PID控制方式相结合,采用模糊自整定PID控制算法实现了温度快速跟踪控制。实验结果表明:模糊自整定PID控制算法比常规PID算法具有更强的鲁棒性,能够克服控制对象热惯性参数时变性的影响,降低了输出温度最大超调量,提高了稳态精度。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent measurement based studies reveal that most of the Internet connections are short in terms of the amount of traffic they carry (mice), while a small fraction of the connections are carrying a large portion of the traffic (elephants). A careful study of the TCP protocol shows that without help from an Active Queue Management (AQM) policy, short connections tend to lose to long connections in their competition for bandwidth. This is because short connections do not gain detailed knowledge of the network state, and therefore they are doomed to be less competitive due to the conservative nature of the TCP congestion control algorithm. Inspired by the Differentiated Services (Diffserv) architecture, we propose to give preferential treatment to short connections inside the bottleneck queue, so that short connections experience less packet drop rate than long connections. This is done by employing the RIO (RED with In and Out) queue management policy which uses different drop functions for different classes of traffic. Our simulation results show that: (1) in a highly loaded network, preferential treatment is necessary to provide short TCP connections with better response time and fairness without hurting the performance of long TCP connections; (2) the proposed scheme still delivers packets in FIFO manner at each link, thus it maintains statistical multiplexing gain and does not misorder packets; (3) choosing a smaller default initial timeout value for TCP can help enhance the performance of short TCP flows, however not as effectively as our scheme and at the risk of congestion collapse; (4) in the worst case, our proposal works as well as a regular RED scheme, in terms of response time and goodput.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this thesis, extensive experiments are firstly conducted to characterize the performance of using the emerging IEEE 802.15.4-2011 ultra wideband (UWB) for indoor localization, and the results demonstrate the accuracy and precision of using time of arrival measurements for ranging applications. A multipath propagation controlling technique is synthesized which considers the relationship between transmit power, transmission range and signal-to-noise ratio. The methodology includes a novel bilateral transmitter output power control algorithm which is demonstrated to be able to stabilize the multipath channel, and enable sub 5cm instant ranging accuracy in line of sight conditions. A fully-coupled architecture is proposed for the localization system using a combination of IEEE 802.15.4-2011 UWB and inertial sensors. This architecture not only implements the position estimation of the object by fusing the UWB and inertial measurements, but enables the nodes in the localization network to mutually share positional and other useful information via the UWB channel. The hybrid system has been demonstrated to be capable of simultaneous local-positioning and remote-tracking of the mobile object. Three fusion algorithms for relative position estimation are proposed, including internal navigation system (INS), INS with UWB ranging correction, and orientation plus ranging. Experimental results show that the INS with UWB correction algorithm achieves an average position accuracy of 0.1883m, and gets 83% and 62% improvements on the accuracy of the INS (1.0994m) and the existing extended Kalman filter tracking algorithm (0.5m), respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The amount of distributed generation connected to the distribution network is increasing. To use this resource more effectively, splitting of the distribution network, or islanding the system, for prevention of power outages is being considered by some utilities. In this paper an islanding method that avoids out-ofsynchronism re-closure is proposed. The island is kept in synchronism with the rest of the utility while it is not electrically connected. This is referred to as synchronous islanded operation. A phase difference control algorithm, developed by the authors, was tested in a single set scenario on a 50-kVA diesel generator using two different governors. These are the “standard product” variable gain governor of the diesel generator and a governor developed by the authors, which utilizes supplementary inputs in addition to engine speed. The results show that phase difference can be controlled within acceptable limits, both in steady state and after load disturbances are applied. The advantages of employing supplementary governor inputs are fully evaluated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dwindling fossil fuel resources and pressures to reduce greenhouse gas emissions will result in a more diverse range of generation portfolios for future electricity systems. Irrespective of the portfolio mix the overarching requirement for all electricity suppliers and system operators is to instantaneously meet demand, to operate to standards and reduce greenhouse gas emissions. Therefore all electricity market participants will ultimately need to use a variety of tools to balance the power system. Thus the role of demand side management with energy storage will be paramount to integrate future diverse generation portfolios. Electric water heating has been studied previously, particularly at the domestic level to provide load control, peak shave and to bene?t end-users ?nancially with lower bills, particularly in vertically integrated monopolies. In this paper a number of continuous direct load control demand response based electric water heating algorithms are modelled to test the effectiveness of wholesale electricity market signals to study the system bene?ts. The results are compared and contrasted to determine which control algorithm showed the best potential for energy savings, system marginal price savings and wind integration.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To optimize the performance of wireless networks, one needs to consider the impact of key factors such as interference from hidden nodes, the capture effect, the network density and network conditions (saturated versus non-saturated). In this research, our goal is to quantify the impact of these factors and to propose effective mechanisms and algorithms for throughput guarantees in multi-hop wireless networks. For this purpose, we have developed a model that takes into account all these key factors, based on which an admission control algorithm and an end-to-end available bandwidth estimation algorithm are proposed. Given the necessary network information and traffic demands as inputs, these algorithms are able to provide predictive control via an iterative approach. Evaluations using analytical comparison with simulations as well as existing research show that the proposed model and algorithms are accurate and effective.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper is concerned with the voltage and reactive power issues surrounding the connection of Distributed Generation (DG) on the low-voltage (LV) distribution network. The presented system-wide voltage control algorithm consists of three stages. Firstly available reactive power reserves are utilized. Then, if required, DG active power output is curtailed. Finally, curtailment of non-critical site demand is considered. The control methodology is tested on a variant of the 13-bus IEEE Node Radial Distribution Test Feeder. The presented control algorithm demonstrated that the distribution system operator (DSO) can maintain voltage levels within a desired statutory range by dispatching reactive power from DG or network devices. The practical application of the control strategy is discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The introduction of parallel processing architectures allowed the real time impelemtation of more sophisticated control algorithms with tighter specifications in terms of sampling time. However, to take advantage of the processing power of these architectures the control engeneer, due to the lack of appropriate tools, must spend a considerable amount of time in the parallelizaton of the control algorithm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a new rate-control algorithm for live video streaming over wireless IP networks, which is based on selective frame discarding. In the proposed mechanism excess 'P' frames are dropped from the output queue at the sender using a congestion estimate based on packet loss statistics obtained from RTCP feedback and from the Data Link (DL) layer. The performance of the algorithm is evaluated through computer simulation. This paper also presents a characterisation of packet losses owing to transmission errors and congestion, which can help in choosing appropriate strategies to maximise the video quality experienced by the end user. Copyright © 2007 Inderscience Enterprises Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En salle d’opération, les tâches de l’anesthésiste sont nombreuses. Alors que l’utilisation de nouveaux outils technologiques l’informe plus fidèlement sur ce qui se passe pour son patient, ces outils font que ses tâches deviennent plus exigeantes. En vue de diminuer cette charge de travail, nous avons considérer l’administration automatique d’agents anesthésiques en se servant de contrôle en boucle fermée. À cette fin, nous avons développé un système d’administration d’un agent anesthésique (le propofol) visant à maintenir à un niveau optimal la perte de conscience du patient pendant toute la durée d’une chirurgie. Le système comprend un ordinateur, un moniteur d’anesthésie et une pompe de perfusion. L’ordinateur est doté d’un algorithme de contrôle qui, à partir d’un indice (Bispectral IndexTM ou BIS) fournit par le moniteur d’anesthésie détermine le taux d’infusion de l’agent anesthésiant. Au départ, l’anesthésiste choisit une valeur cible pour la variable de contrôle BIS et l’algorithme, basé sur système expert, calcule les doses de perfusion de propofol de sorte que la valeur mesurée de BIS se rapproche le plus possible de la valeur cible établie. Comme interface-utilisateur pour un nouveau moniteur d’anesthésie, quatre sortes d’affichage ont été considérés: purement numérique, purement graphique, un mélange entre graphique et numérique et un affichage graphique intégré (soit bidimensionnel). À partir de 20 scenarios différents où des paramètres normaux et anormaux en anesthésie étaient présentés à des anesthésistes et des résidents, l’étude des temps de réaction, de l’exactitude des réponses et de la convivialité (évaluée par le NASA-TLX) a montré qu’un affichage qui combine des éléments graphiques et numériques était le meilleur choix comme interface du système. Une étude clinique a été réalisée pour comparer le comportement du système d’administration de propofol en boucle fermée comparativement à une anesthésie contrôlée de façon manuelle et conventionnelle où le BIS était aussi utilisé. Suite à l’approbation du comité d’éthique et le consentement de personnes ayant à subir des chirurgies générales et orthopédiques, 40 patients ont été distribués également et aléatoirement soit dans le Groupe contrôle, soit dans le Groupe boucle fermée. Après l’induction manuelle de propofol (1.5 mg/kg), le contrôle en boucle fermée a été déclenché pour maintenir l’anesthésie à une cible de BIS fixée à 45. Dans l’autre groupe, le propofol a été administré à l’aide d’une pompe de perfusion et l’anesthésiste avait aussi à garder manuellement l’indice BIS le plus proche possible de 45. En fonction du BIS mesuré, la performance du contrôle exercé a été définie comme excellente pendant les moments où la valeur du BIS mesurée se situait à ±10% de la valeur cible, bonne si comprise de ±10% à ±20%, faible si comprise de ±20% à ±30% ou inadéquate lorsque >±30%. Dans le Groupe boucle fermée, le système a montré un contrôle excellent durant 55% du temps total de l’intervention, un bon contrôle durant 29% du temps et faible que pendant 9% du temps. Le temps depuis l’arrêt de la perfusion jusqu’à l’extubation est de 9 ± 3.7 min. Dans le Groupe contrôle, un contrôle excellent, bon, et faible a été enregistré durant 33%, 33% et 15% du temps respectivement et les doses ont été changées manuellement par l’anesthésiste en moyenne 9.5±4 fois par h. L’extubation a été accomplie après 11.9 ± 3.3 min de l’arrêt de la perfusion. Dans le Groupe boucle fermée, un contrôle excellent a été obtenu plus longtemps au cours des interventions (P<0.0001) et un contrôle inadéquat moins longtemps (P=0.001) que dans le Groupe contrôle. Le système en boucle fermée d’administration de propofol permet donc de maintenir plus facilement l’anesthésie au voisinage d’une cible choisie que l’administration manuelle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the recent years, the unpredictable growth of the Internet has moreover pointed out the congestion problem, one of the problems that historicallyha ve affected the network. This paper deals with the design and the evaluation of a congestion control algorithm which adopts a FuzzyCon troller. The analogyb etween Proportional Integral (PI) regulators and Fuzzycon trollers is discussed and a method to determine the scaling factors of the Fuzzycon troller is presented. It is shown that the Fuzzycon troller outperforms the PI under traffic conditions which are different from those related to the operating point considered in the design.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A neural network enhanced self-tuning controller is presented, which combines the attributes of neural network mapping with a generalised minimum variance self-tuning control (STC) strategy. In this way the controller can deal with nonlinear plants, which exhibit features such as uncertainties, nonminimum phase behaviour, coupling effects and may have unmodelled dynamics, and whose nonlinearities are assumed to be globally bounded. The unknown nonlinear plants to be controlled are approximated by an equivalent model composed of a simple linear submodel plus a nonlinear submodel. A generalised recursive least squares algorithm is used to identify the linear submodel and a layered neural network is used to detect the unknown nonlinear submodel in which the weights are updated based on the error between the plant output and the output from the linear submodel. The procedure for controller design is based on the equivalent model therefore the nonlinear submodel is naturally accommodated within the control law. Two simulation studies are provided to demonstrate the effectiveness of the control algorithm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A nonlinear general predictive controller (NLGPC) is described which is based on the use of a Hammerstein model within a recursive control algorithm. A key contribution of the paper is the use of a novel, one-step simple root solving procedure for the Hammerstein model, this being a fundamental part of the overall tuning algorithm. A comparison is made between NLGPC and nonlinear deadbeat control (NLDBC) using the same one-step nonlinear components, in order to investigate NLGPC advantages and disadvantages.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The authors compare the performance of two types of controllers one based on the multilayered network and the other based on the single layered CMAC network (cerebellar model articulator controller). The neurons (information processing units) in the multi-layered network use Gaussian activation functions. The control scheme which is considered is a predictive control algorithm, along the lines used by Willis et al. (1991), Kambhampati and Warwick (1991). The process selected as a test bed is a continuous stirred tank reactor. The reaction taking place is an irreversible exothermic reaction in a constant volume reactor cooled by a single coolant stream. This reactor is a simplified version of the first tank in the two tank system given by Henson and Seborg (1989).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Energy storage is a potential alternative to conventional network reinforcementof the low voltage (LV) distribution network to ensure the grid’s infrastructure remainswithin its operating constraints. This paper presents a study on the control of such storagedevices, owned by distribution network operators. A deterministic model predictive control (MPC) controller and a stochastic receding horizon controller (SRHC) are presented, wherethe objective is to achieve the greatest peak reduction in demand, for a given storagedevice specification, taking into account the high level of uncertainty in the prediction of LV demand. The algorithms presented in this paper are compared to a standard set-pointcontroller and bench marked against a control algorithm with a perfect forecast. A specificcase study, using storage on the LV network, is presented, and the results of each algorithmare compared. A comprehensive analysis is then carried out simulating a large number of LV networks of varying numbers of households. The results show that the performance of each algorithm is dependent on the number of aggregated households. However, on a typical aggregation, the novel SRHC algorithm presented in this paper is shown to outperform each of the comparable storage control techniques.