896 resultados para Contrast-enhanced study
Resumo:
Magnetic resonance angiography (MRA) provides a noninvasive means to detect the presence, location and severity of atherosclerosis throughout the vascular system. In such studies, and especially those in the coronary arteries, the vessel luminal area is typically measured at multiple cross-sectional locations along the course of the artery. The advent of fast volumetric imaging techniques covering proximal to mid segments of coronary arteries necessitates automatic analysis tools requiring minimal manual interactions to robustly measure cross-sectional area along the three-dimensional track of the arteries in under-sampled and non-isotropic datasets. In this work, we present a modular approach based on level set methods to track the vessel centerline, segment the vessel boundaries, and measure transversal area using two user-selected endpoints in each coronary of interest. Arterial area and vessel length are measured using our method and compared to the standard Soap-Bubble reformatting and analysis tool in in-vivo non-contrast enhanced coronary MRA images.
Resumo:
OBJECTIVES: To prospectively assess the stiffness of incidentally discovered focal liver lesions (FLL) with no history of chronic liver disease or extrahepatic cancer using shearwave elastography (SWE). METHODS: Between June 2011 and May 2012, all FLL fortuitously discovered on ultrasound examination were prospectively included. For each lesion, stiffness was measured (kPa). Characterization of the lesion relied on magnetic resonance imaging (MRI) and/or contrast-enhanced ultrasound, or biopsy. Tumour stiffness was analysed using ANOVA and non-parametric Mann-Whitney tests. RESULTS: 105 lesions were successfully evaluated in 73 patients (61 women, 84%) with a mean age of 44.8 (range: 20‒75). The mean stiffness was 33.3 ± 12.7 kPa for the 60 focal nodular hyperplasia (FNH), 19.7 ± 9.8 k Pa for the 17 hepatocellular adenomas (HCA), 17.1 ± 7 kPa for the 20 haemangiomas, 11.3 ± 4.3 kPa for the five focal fatty sparing, 34.1 ± 7.3 kPa for the two cholangiocarcinomas, and 19.6 kPa for one hepatocellular carcinoma (p < 0.0001). There was no difference between the benign and the malignant groups (p = 0.64). FNHs were significantly stiffer than HCAs (p < 0.0001). Telangiectatic/inflammatory HCAs were significantly stiffer than the steatotic HCAs (p = 0.014). The area under the ROC curve (AUROC) for differentiating FNH from other lesions was 0.86 ± 0.04. CONCLUSION: SWE may provide additional information for the characterization of FFL, and may help in differentiating FNH from HCAs, and in subtyping HCAs. KEY POINTS: ? SWE might be helpful for the characterization of solid focal liver lesions ? SWE cannot differentiate benign from malignant liver lesions ? FNHs are significantly stiffer than other benign lesions ? Telangiectatic/inflammatory HCA are significantly stiffer than steatotic ones.
Resumo:
With the steep increase in the use of cross-sectional imaging in recent years, the incidentally detected adrenal lesion, or "incidentaloma", has become an increasingly common diagnostic problem for the radiologist, and a need for an approach to classifying these lesions as benign, malignant or indeterminate with imaging has spurred an explosion of research. While most incidentalomas represent benign disease, typically an adenoma, the possibility of malignant involvement of the adrenal gland necessitates a reliance on imaging to inform management decisions. In this article, we review the literature on adrenal gland imaging, with particular emphasis on computed tomography, magnetic resonance imaging, and photon-emission tomography, and discuss how these findings relate to clinical practice. Emerging technologies, such as contrast-enhanced ultrasonography, dual-energy computed tomography, and magnetic resonance spectroscopic imaging will also be briefly addressed.
Resumo:
Multiparametric MR (mpMR) imaging is rapidly evolving into the mainstay in prostate cancer (PCa) imaging. Generally, the examination consists of T2-weighted sequences, diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE) evaluation, and less often proton MR spectroscopy imaging (MRSI). Those functional techniques are related to biological properties of the tumor, so that DWI correlates to cellularity and Gleason scores, DCE correlates to angiogenesis, and MRSI correlates to cell membrane turnover. The combined use of those techniques enhances the diagnostic confidence and allows for better characterization of PCa. The present article reviews and illustrates the technical aspects and clinical applications of each component of mpMR imaging, in a practical approach from the urological standpoint.
Resumo:
Existing research investigating interactions between visual and oral sensory cues has tended to use model food systems. In contrast, this study compared product quality assessments of corn-fed and wheat-fed chicken products among persons recruited in Northern Ireland. Three approaches have been adopted to investigate the effect of colour upon consumer choice of chicken: sensory assessment under normal lighting; focus group discussion; and sensory assessment under controlled lighting conditions. Initial consumer sensory assessment indicated that wheat-fed chicken was perceived to be tenderer and to have a more intense flavour than that which was corn-fed. Qualitative enquiry discerned that this was because consumers perceived the yellow colour of corn-fed chicken negatively. Yellow-coloured corn-fed chicken was therefore again compared with wheat-fed chicken in terms of flavour, texture and overall liking with the flesh colour disguised by means of controlled lighting. Quality ratings for corn-fed chicken were more positive when the yellow flesh colour was disguised, with corn-fed chicken judged to be tenderer than wheat-fed chicken and more flavoursome. This study illustrates the importance of using a combination of methods to gain insight into interactions between different sensory modalities in consumer quality judgements and adds to previous research on the importance of colour upon consumer choice of real foods. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Literature on comparative capitalism remains divided between approaches founded on stylized case study evidence and descriptions of broad trends, and those that focus on macro data. In contrast, this study explores the relevance of Amable’s approach to understanding differences in employment relations practice, based on firm-level micro data. The article examines employee–employer interdependence (including turnover rates) in different categories of economy as classified by Amable. The findings confirm that exit – whether forced or voluntary – remains more common in market-based economies than in their continental counterparts and that institutionalized employee voice is an important variable in reducing turnover. However, there is as much diversity within the different country categories as between them, and across continental Europe. In Denmark’s case, high turnover is combined with high unionization, showing the effects of a ‘flexicurity’ strategy. While employee voice may be stronger in Scandinavia, interdependence is weaker than in continental Europe.
Resumo:
Background—A major problem in procurement of donor hearts is the limited time a donor heart remains viable. After cardiectomy, ischemic hypoxia is the main cause of donor heart degradation. The global myocardial ischemia causes a cascade of oxygen radical formation that cumulates in an elevation in hydrogen ions (decrease in pH), irreversible cellular injury, and potential microvascular changes in perfusion. Objective—To determine the changes of prolonged storage times on donor heart microvasculature and the effects of intermittent antegrade perfusion. Materials and Methods—Using porcine hearts flushed with a Ribosol-based cardioplegic solution, we examined how storage time affects microvascular myocardial perfusion by using contrast-enhanced magnetic resonance imaging at a mean (SD) of 6.1 (0.6) hours (n=13) or 15.6 (0.6) hours (n=11) after cardiectomy. Finally, to determine if administration of cardioplegic solution affects pH and microvascular perfusion, isolated hearts (group 1, n=9) given a single antegrade dose, were compared with hearts (group 2, n=8) given intermittent antegrade cardioplegia (150 mL, every 30 min, 150 mL/min) by a heart preservation device. Khuri pH probes in left and right ventricular tissue continuously measured hydrogen ion levels, and perfusion intensity on magnetic resonance images was plotted against time. Results—Myocardial perfusion measured via magnetic resonance imaging at 6.1 hours was significantly greater than at 15.6 hours (67% vs 30%, P= .00008). In group 1 hearts, the mean (SD) for pH at the end of 6 hours decreased to 6.2 (0.2). In group 2, hearts that received intermittent antegrade cardioplegia, pH at the end of 6 hours was higher at 6.7 (0.3) (P=.0005). Magnetic resonance imaging showed no significant differences between the 2 groups in contrast enhancement (group 1, 62%; group 2, 40%) or in the wet/dry weight ratio. Conclusion—Intermittent perfusion maintains a significantly higher myocardial pH than does a conventional single antegrade dose. This difference may translate into an improved quality of donor hearts procured for transplantation, allowing longer distance procurement, tissue matching, improved outcomes for transplant recipients, and ideally a decrease in transplant-related costs.
Resumo:
We present the case of a 54-year-old female with a previous history of lung fibrosis secondary to methotrexate used for rheumatoid arthritis who was referred to cardiology evaluation due to precordial pain. Echocardiography showed biatrial enlargement with an enlarged coronary sinus and tubular image posterior to the heart. On the coronary angiogram, the right coronary artery was enlarged, and a distal fistula was identified. The patient underwent a contrast enhanced cardiac computed tomography which demonstrated an aneurysmatic right coronary artery with a distal fistula to the right atrium and coronary sinus. As the chest pain did not recur and there was a high risk of the intervention to correct coronary fistula, the patient remained on conservative treatment.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background: The problem of diagnosing whether a solitary pulmonary nodule is benign or malignant is even greater in developing countries due to a higher prevalence of infectious diseases. These infections generate a large number of patients who are generally asymptomatic and with a pulmonary nodule that cannot be accurately defined as having benign or malignant etiology.Purpose: To verify the percentages of benign versus malignant non-calcified nodules, the length of time after contrast agent injection is spiral computed tomography (CT) most sensitive and specific, and whether three postcontrast phases are necessary.Material and Methods: We studied 23 patients with solitary pulmonary nodules identified on chest radiographs or CT. Spiral scans were obtained with Swensen protocol, but at 3, 4, and 5 min after contrast injection onset. Nodules were classified as benign or malignant by histopathological examination or by an absence or presence of growth after 2 years of follow-up CT.Results: Of the 23 patients studied, 18 (78.2%) showed a final diagnosis of benign and five (21.7%) malignant nodules. Despite the small sample size, we obtained results similar to those of Swensen et al., with 80.0% sensitivity, 55.5% specificity, and 60.8% accuracy. Four minutes gave the greatest mean enhancement in both malignant and benign lesions.Conclusion: Small non-calcified benign nodules were much more frequent than malignant nodules. The best time for dynamic contrast-enhanced CT density analysis was 4 min postcontrast. As well as saving time and money, this simplified Swensen protocol with only precontrast and 4 min postcontrast phases also reduces patient exposure to ionizing radiation.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
PURPOSE To ascertain whether the volume and circumference of the lacrimal sac and nasolacrimal duct as measured by contrast-enhanced computed tomographic dacryocystography (CT-DCG) before and after balloon dacryoplasty could be used to predict clinical success in children with congenital nasolacrimal obstruction. METHODS Nasolacrimal ducts of children aged 2 to 6 years with clinical signs of congenital nasolacrimal duct obstruction undergoing balloon dilation were imaged with contrast-enhanced CT-DCG before and 5 minutes after the procedure. The circumference of the most dilated portion of the lacrimal sac was measured on the axial plane. The volume of contrast within the nasolacrimal duct and sac was also measured before and after the procedure. Clinical success was defined as the disappearance of signs of epiphora. RESULTS A total of 18 nasolacrimal ducts of 13 children were included. The average circumference of the most dilated portion of the lacrimal sac was 1.30 +/- 0.45 cm (range, 0.64-2.50 cm) before the procedure. The average contrast volume was 0.12 +/- 0.08 cm(3) (range, 0.01-0.38 cm(3)) before and 0.07 +/- 0.06 cm(3) (range, 0.01-0.20 cm(3)) after (P = 0.01). Data were analyzed using multivariate logistic regression with a backward variable input model; a decrease in contrast volume before and after dilation (P = 0.04) was associated with clinical success, whereas the larger size of the most dilated portion of the lacrimal sac (P = 0.01) was associated with clinical failure. CONCLUSIONS Contrast-enhanced CT-DCG provides useful information about nasolacrimal anatomy in children with congenital nasolacrimal duct obstruction. The decrease in contrast volume before and after balloon dilation was predictive of success; A larger size of the most dilated portion of the lacrimal sac was associated with clinical failure. (J AAPOS 2012;16:464-467)
Resumo:
BACKGROUND: Because of their similar visual appearance, differentiation of left ventricular thrombotic material and myocardial wall can be difficult in contrast-enhanced coronary computed tomography (CT) angiography. OBJECTIVE: We identified typical thrombi attenuation of left ventricular thrombi with the use of CT measurement. METHODS: Over a time period of 6 years; we retrospectively identified 31 patients who showed a left ventricular thrombus in CT angiography datasets. Patients underwent routine contrast cardiac CT to investigate coronary artery disease. CT attenuation of each thrombus was assessed in the 4-chamber view. CT densities were also determined in the ascending aorta, left ventricle, and myocardial wall both in the mid-septal and mid-lateral segments. The mean CT attenuation of thrombi and the difference between attenuation in thrombi, left ventricular cavity, and myocardial wall were determined. The ratio of attenuation values in thrombus versus aorta and myocardium versus aorta were also determined. RESULTS: Mean (+/- SD) CT attenuation of all left ventricular thrombi in 31 patients was 43.2 +/- 15.3 HU (range, 25-80 HU). Mean CT densities of septal and lateral myocardial wall were 102.9 +/- 23.1 HU (range, 63-155 HU) and 99.3 +/- 28.7 HU (range, 72-191 HU), respectively, and were thus significantly higher than the CT attenuation of thrombi (P < 0.001). A threshold of 65 HU yielded a sensitivity, specificity, and positive and negative predictive values of 94%, 97%, 94%, and 97%, respectively, to differentiate thrombus from the myocardial wall. The mean ratio between CT attenuation of thrombus and CT attenuation within the ascending aorta was 0.11 +/- 0.05 (range, 0.04-0.23), which was significantly lower compared with the mean ratio between CT attenuation of the myocardial wall and the CT attenuation within the ascending aorta. CONCLUSION: CT attenuation within left ventricular thrombi was significantly lower than myocardial attenuation in CT angiography datasets. Assessment of CT attenuation may contribute to the differentiation of thrombi. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.
Resumo:
Background New potential hazards in the use of ultrasound (US) are implied in new diagnostic applications of US, such as contrast enhanced US. Aim To assess the level of awareness and knowledge on safety issues of clinical use of US among physicians who are members of the Italian National Society for Ultrasound (SIUMB) Materials and methods A questionnaire including 11 multiple choice quiz was sent by e-mail to members of SIUMB, who preliminarly agreed to participate in this initiative. The answers were received anonimously and statistically analyzed. Results The number of returned valid questionnaires was 97 (8 were considered not valid for less than 10 answers filled). Mean age of the responders was 44 years old, and the average time the physician has been performing ultrasound examinations was 13 years. The principal workplace (70%) was a public Hospital. Physicians seemed to know the general definitions of principal safety-parameters, but few of them knew the definition of specific indexes. There was a general knowledge about the safe use of ultrasound in obstetrics, but there was a poor knowledge of biological effects of US: only about 37% answered correctly to questions about damage of vasculature of lung by high Mechanical Index US investigation and about the increase of temperature under the probe, according to the thermal indexes. Conclusion In conclusion the present findings indicate that greater efforts of National Ultrasound Societies are warranted in disseminating knowledge about the bio-effects of diagnostic ultrasound modalities among their members to prevent possible hazards.
Resumo:
Aim: To evaluate the early response to treatment to an antiangiogenetic drug (sorafenib) in a heterotopic murine model of hepatocellular carcinoma (HCC) using ultrasonographic molecular imaging. Material and Methods: the xenographt model was established injecting a suspension of HuH7 cells subcutaneously in 19 nude mice. When tumors reached a mean diameter of 5-10 mm, they were divided in two groups (treatment and vehicle). The treatment group received sorafenib (62 mg/kg) by daily oral gavage for 14 days. Molecular imaging was performed using contrast enhanced ultrasound (CEUS), by injecting into the mouse venous circulation a suspension of VEGFR-2 targeted microbubbles (BR55, kind gift of Bracco Swiss, Geneve, Switzerland). Video clips were acquired for 6 minutes, then microbubbles (MBs) were destroyed by a high mechanical index (MI) impulse, and another minute was recorded to evaluate residual circulating MBs. The US protocol was repeated at day 0,+2,+4,+7, and +14 from the beginning of treatment administration. Video clips were analyzed using a dedicated software (Sonotumor, Bracco Swiss) to quantify the signal of the contrast agent. Time/intensity curves were obtained and the difference of the mean MBs signal before and after high MI impulse (Differential Targeted Enhancement-dTE) was calculated. dTE represents a numeric value in arbitrary units proportional to the amount of bound MBs. At day +14 mice were euthanized and the tumors analyzed for VEGFR-2, pERK, and CD31 tissue levels using western blot analysis. Results: dTE values decreased from day 0 to day +14 both in treatment and vehicle groups, and they were statistically higher in vehicle group than in treatment group at day +2, at day +7, and at day +14. With respect to the degree of tumor volume increase, measured as growth percentage delta (GPD), treatment group was divided in two sub-groups, non-responders (GPD>350%), and responders (GPD<200%). In the same way vehicle group was divided in slow growth group (GPD<400%), and fast growth group (GPD>900%). dTE values at day 0 (immediately before treatment start) were higher in non-responders than in responders group, with statistical difference at day 2. While dTE values were higher in the fast growth group than in the slow growth group only at day 0. A significant positive correlation was found between VEGFR-2 tissue levels and dTE values, confirming that level of BR55 tissue enhancement reflects the amount of tissue VEGF receptor. Conclusions: the present findings show that, at least in murine experimental models, CEUS with BR55 is feasable and appears to be a useful tool in the prediction of tumor growth and response to sorafenib treatment in xenograft HCC.