1000 resultados para Concentração de Espermatozóides


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A column packed with 5-(4-dimethylaminobenzylidene)rhodanine adsorbed on silica gel was used for the preconcentration of Cd, Ni and Zn at different spiked solutions prior to their determination by inductively coupled plasma atomic emission spectrometry. This column allowed recoveries over than 98% for the above elements and accurate analyses of coastal sea-water certified reference material were also achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work discusses sample preparation processes for gas chromatography (GC) based on the technique of extraction through membrane permeation (MPE). The MPE technique may be easily coupled to GC via a relatively simple device, which is a module that holds the membrane and is directly connected to the GC column. The possibility of operational errors due to sample handling is substantially reduced in an MPE-GC system because the sample preparation and the chemical analysis are accomplished as a one-step process. The MPE technique is of relatively wide application as it can be used for aqueous samples, solid samples and gaseous samples. Depending on the type of sample the extraction is performed with the membrane in direct contact with the sample or in contact with its headspace. The MPE-GC technique is very useful in trace analysis, due to the time-dependent enrichment of the analyte. A typical application of MPE-GC is the analysis of VOCs present in water that may be accomplished with detection limits at the low ppb (mugL-1) level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When organic compounds present in biological fluids are analysed by chromatographic methods, it is generally necessary to carry out a prior sample preparation due the high complexity of this type of sample, especially when the compounds to be determinated are found in very low concentrations. This article describes some of the principal methods for sample preparation in analyses of substances present in biological fluids. The methods include liquid-liquid extraction, solid phase extraction, supercritical fluid extraction and extraction using solid and liquid membranes. The advantages and disadvantages of these methods are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reaction between hydroxy-terminated polybutadiene and isophorone diisocyanate constitutes the base of the curing process of the most composite solid propellant used in the propulsion of solid rocket propellant. In this work, differential scanning calorimetry and viscosity measurements were used to evaluate the effect of the ferric acetylacetonate catalyst concentration on the reaction between HTBR and IPDI. These analyses show one exotherm, which shifts to lower temperatures as the catalyst concentration increases. The viscosity analyses show that the increase of temperature causes, at first, a reduction in the mixture viscosity, reaching a minimum range called gelification region (increasing the crosslinking density).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to propose two different didactic experiments, which can be used in practical classes of analytical chemistry courses. More flexible experiments related to the theme, giving some options to the instructor are proposed. In this way, the Experiment 1 was divided in two parts. In the first one, the visualization of two distinct phases separation is emphasized: the rich and the poor phases in surfactant. In the second part, the metal pre-concentration (Co as example) is emphasized. The Experiment 2 has three different parts. In the first one, the complex formation is pointed out, in the second one, the pH influence is shown and in the last one, the influence of the complexation time is demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for determination of lead and cadmium in aqueous samples using solvent microextraction and dithizone as complexing agent with FAAS was developed. Solvent microextraction parameters were optimized. The effect of foreign ions on the extraction yields was studied. The extraction was carried out until the aqueous to organic phase ratio achieved a 250 fold preconcentration of metals. For preconcentration times of 4 min the 3sigma detection limits, relative standard deviations (n=7) and linear calibration ranges were 1.6 mug L-1, 5.8% and 10.0 -- 80.0 mug L-1 for lead and 11.1 ng L-1, 5.9% and 0.3 -- 3.0 mug L-1 for cadmium, respectively. The solvent microextraction procedure presented here was applied to the determination of lead and cadmium in natural waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automatic flow injection procedure for spectrophotometric aluminium determination in purified water and solutions containing high salts concentrations used for hemodyalisis treatment was developed. The method was base on reaction of Al3+ with cianine eriochrome R (ECR) after preconcentration using the AG50W-X8 cationic-exchange resin. Elution was carried out using a 1 % (m/v) calcium chloride solution. The manifold comprised an automatic proporcional injector controlled by a computer equipped with an eletronic interface and software written in QuicBASIC 4.5 with facilities to control the injector and perform data acquisition. Samples with concentration ranging from 4.96 to 19.90 µg L-1 Al were analyzed and recoveries between 88 and 113% were obtained by using the standard addition method. Other profitable analytical characteristics such as a relative standard deviation 1.3 % (n = 10) for a typical sample 14.5 µg L-1 Al, a linear response ranging up to 60.0 µg L-1Al, and a sampling throughput of 10 determinations per hour were achieved. A detection limit of 4.2 µg L-1 Al was estimated as suggested by IUPAC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to explore the possibility of the application of a non-ionic resin obtained by impregnation of Alizarin Red S (VAS) in Amberlite XAD-7 for manganese, copper and zinc separation and preconcentration in saline matrices. For these system, the metals were quantitatively retained, in the pH range 8.5-10.0, by using 0.50 g of solid phase, stirring time of five minutes and a total mass up to 200 mug of each cation. The sorbed elements were subsequently eluted and a fifty-fold, ten-fold and ten-fold preconcentration factor for to Zn, Cu and Mn were obtained, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last three decades carbonyl compounds, aldehydes and ketones, have received a great deal of attention due to their strong influence on photochemical smog formation and their recognized adverse human health effects. Carbonyl compounds are directly emitted into the atmosphere by combustion sources and also produced from photochemical oxidation of hydrocarbons and other organic compounds. In this paper it is presented a general overview about the carbonyl compounds sources, reactivity, concentration levels and toxicological effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of a methodology for solid phase extraction (SPE) and pre-concentration of nitrosamines from aqueous samples using granular activated charcoal as stationary phase. micelar electrokinetic capillary Chromatography (MEKC) was used for the separation and identification of the nitrosamines in the extracts. Using a sample with 50 µg l-1 of each nitrosamines standards (dimethylnitrosamine, DMN; diethylnitrosamine, DEN; N-nitrosopyrrolidine, NPYR; N-nitrosopiperidine, NPIP; N-nitrosomorpholine, NMOR), the methodology showed a range of recuperation from 29 to 107% with a linear zone between 10 and 500 µg l-1. The developed methodology can be applicable to the determination of these analytes in different aqueous samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dilutions of methylmetacrylate ranging between 1 and 50 ppm were obtained from a stock solution of 1 ml of monomer in 100 ml of deionised water, and were analyzed by an absorption spectrophotometer in the UV-visible. Absorbance values were used to develop a calibration model based on the PLS, with the aim to determine new sample concentrations. The number of latent variables used was 6, with the standard errors of calibration and prediction found to be 0,048 ml/100 ml and 0,058 ml/100 ml. The calibration model was successfully used to calculate the concentration of monomer released in water, where complete dentures were kept for one hour after polymerization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was the determination of the critical micelle concentration (CMC) of the sodium dodecyl sulfate (SDS) surfactant using spectroscopic and conductimetric determinations and to compare these methodologies in the determination of the CMC of different humic acids (HA). The CMC obtained by conductimetric determination was satisfactory. By spectroscopic determination two values of the CMC were obtained for HA. These values can be to due the intra and intermolecular interactions in the HA structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article gives an overview of polymer materials used for lead separation and preconcentration. Different kinds of polymer resins, commercial or not, are cited as well as the most used functional groups attached to polymer backbones. The synthesis of these resins and conditions of lead adsorption and elution are remarked. The influence of the porous structure of the polymer on the resines performance is described as well as the use of spacer arms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-element analyses of sediment samples from the Santos-Cubatão Estuarine System were carried out to investigate the spatial and seasonal variability of trace-element concentrations. The study area contains a rich mangrove ecosystem that is a habitat for tens of thousands of resident and migratory birds, some of them endangered globally. Enrichments of metals in fine-grained surface sediments are, in decreasing order, Hg, Mn, La, Ca, Sr, Cd, Zn, Pb, Ba, Cu, Cr, Fe, Nb, Y, Ni and Ga, relative to pre-industrial background levels. The maximum enrichment ranged from 49 (Hg) to 3.1 (Ga). Mercury concentrations were greater in the Cubatão river than in other sites, while the other elements showed greater concentrations in the Morrão river. Concentrations of Mn were significantly greater in winter and autumn than in summer and spring. However, other elements (e.g. Cd and Pb) showed the opposite, with greater concentrations in summer and spring. This study suggests that seasonal changes in physical and chemical conditions may affect the degree of sediment enrichment and therefore make the assessment of contamination difficult. Consequently, these processes need to be considered when assessing water quality and the potential contamination of biota.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a review about the use of Blue rayon in the extraction and concentration of environmental contaminants in the aquatic environment. Blue rayon is an adsorbent composed of fibers covalently linked with copper phthalocyanine trisulphonate that has the ability to selectively adsorb polycyclic compounds. Blue rayon can be used in situ, in columns or in flasks. This method showed to be efficient in the extraction of important classes of environmental contaminants like the polycyclic aromatic hydrocarbons (PAHs), aromatic amines and phenylbenzotriazoles (PBTAs) and can be an important tool in monitoring studies for the evaluation of water quality.