945 resultados para Computerized Axial Tomography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: This study evaluated the interobserver reliability of plain radiograpy versus computed tomography (CT) for the Universal and AO classification systems for distal radius fractures. Patients and methods: Five observers classified 21 sets of distal radius fractures using plain radiographs and CT independently. Kappa statistics were used to establish a relative level of agreement between observers for both readings. Results: Interobserver agreement was rated as moderate for the Universal classification and poor for the AO classification. Reducing the AO system to 9 categories and to its three main types reliability was raised to a ""moderate"" level. No difference was found for interobserver reliability between the Universal classification using plain radiographs and the Universal classification using computed tomography. Interobserver reliability of the AO classification system using plain radiographs was significantly higher than the interobserver reliability of the AO classification system using only computed tomography. Conclusion: From these data, we conclude that classification of distal radius fractures using CT scanning without plain radiographs is not beneficial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The development of products and services for health care systems is one of the most important phenomena to have occurred in the field of health care over the last 50 years. It generates significant commercial, medical and social results. Although much has been done to understand how health technologies are adopted and regulated in developed countries, little attention has been paid to the situation in low- and middle-income countries (LMICs). Here we examine the institutional environment in which decisions are made regarding the adoption of expensive medical devices into the Brazilian health care system. Methods We used a case study strategy to address our research question. The empirical work relied on in-depth interviews (N = 16) with representatives of a wide range of actors and stakeholders that participate in the process of diffusion of CT (computerized tomography) scanners in Brazil, including manufacturers, health care organizations, medical specialty societies, health insurance companies, regulatory agencies and the Ministry of Health. Results The adoption of CT scanners is not determined by health policy makers or third-party payers of public and private sectors. Instead, decisions are primarily made by administrators of individual hospitals and clinics, strongly influenced by both physicians and sales representatives of the medical industry who act as change agents. Because this process is not properly regulated by public authorities, health care organizations are free to decide whether, when and how they will adopt a particular technology. Conclusions Our study identifies problems in how health care systems in LMICs adopt new, expensive medical technologies, and suggests that a set of innovative approaches and policy instruments are needed in order to balance the institutional and professional desire to practise a modern and expensive medicine in a context of health inequalities and basic health needs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Functional brain variability has been scarcely investigated in cognitively healthy elderly subjects, and it is currently debated whether previous findings of regional metabolic variability are artifacts associated with brain atrophy. The primary purpose of this study was to test whether there is regional cerebral age-related hypometabolism specifically in later stages of life. MATERIALS AND METHODS: MR imaging and FDG-PET data were acquired from 55 cognitively healthy elderly subjects, and voxel-based linear correlations between age and GM volume or regional cerebral metabolism were conducted by using SPM5 in images with and without correction for PVE. To investigate sex-specific differences in the pattern of brain aging, we repeated the above voxelwise calculations after dividing our sample by sex. RESULTS: Our analysis revealed 2 large clusters of age-related metabolic decrease in the overall sample, 1 in the left orbitofrontal cortex and the other in the right temporolimbic region, encompassing the hippocampus, the parahippocampal gyrus, and the amygdala. The division of our sample by sex revealed significant sex-specific age-related metabolic decrease in the left temporolimbic region of men and in the left dorsolateral frontal cortex of women. When we applied atrophy correction to our PET data, none of the above-mentioned correlations remained significant. CONCLUSIONS: Our findings suggest that age-related functional brain variability in cognitively healthy elderly individuals is largely secondary to the degree of regional brain atrophy, and the findings provide support to the notion that appropriate PVE correction is a key tool in neuroimaging investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Increasing age and cholesterol levels, male gender, and family history of early coronary heart disease (CHD) are associated with early onset of CHD in familial hypercholesterolemia (FH). Objective: Assess subclinical atherosclerosis by computed tomography coronary angiography (CTCA) and its association with clinical and laboratorial parameters in asymptomatic FH subjects. Methods: 102 FH subjects (36% male, 45 +/- 13 years, LDL-c 280 +/- 54 mg/dL) and 35 controls (40% male, 46 +/- 12 years, LDL-c 103 +/- 18 mg/dL) were submitted to CTCA. Plaques were divided into calcified, mixed and non-calcified; luminal stenosis was characterized as >50% obstruction. Results: FH had a greater atherosclerotic burden represented by higher number of patients with: plaques (48% vs. 14%, p = 0.0005), stenosis (19% vs. 3%, p = 0.015), segments with plaques (2.05 +/- 2.85 vs. 0.43 +/- 1.33, p = 0.0016) and calcium scores (55 perpendicular to 129 vs. 38 perpendicular to 140, p = 0.0028). After multivariate analysis, determinants of plaque presence were increasing age (OR = 2.06, for age change of 10 years, CI95%: 1.38-3.07, p < 0.001) and total cholesterol (OR = 1.86, for cholesterol change by 1 standard deviation, CI95%: 1.09-3.15, p = 0.027). Coronary calcium score was associated with the presence of stenosis (OR = 1.54; CI95%: 1.27-1.86, p < 0.001, for doubling the calcium score). Male gender was directly associated with the presence of non-calcified plaques (OR: 15.45, CI95% 1.72-138.23, p = 0.014) and inversely with calcified plaques (OR = 0.21, CI95%: 0.05-0.84, p = 0.027). Family history of early CHD was associated with the presence of mixed plaques (OR = 4.90, CI95%: 1.32-18.21, p = 0.018). Conclusions: Patients with FH had an increased burden of coronary atherosclerosis by CTCA. The burden of atherosclerosis and individual plaque subtypes differed with the presence of other associated risk factors, with age and cholesterol being most important. A coronary calcium score of zero ruled out obstructive disease in this higher risk population. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. Chronic rhinosinusitis (CRS) is a risk factor for asthma exacerbations and is associated with greater clinical severity. Discrepancies may exist between CRS clinical diagnosis and data from paranasal sinus (PS) X-ray or computed tomography (CT) scans. The objective was to compare PS involvement using low-dose CT and plain X-ray in allergic asthmatic patients with rhinitis. Methods. Patients underwent PS radiography in the frontal and mentonian positions and low-dose CT consisting of six to eight coronal scans performed on the central region of the sphenoidal, ethmoidal, maxillary, and frontal sinuses. Possible results for each sinus were a normal aspect or the presence of mucosal thickening, opacification, and/or air-fluid level. Results. Eighty-five (93.4%) of 91 study patients had radiological changes on radiography or CT. In only six (6.6%) were both tests normal. The maxillary was the most involved sinus by both methods. Simultaneous PS abnormalities were observed in 40.5% on X-ray and 56.7% on CT. For the frontal, ethmoidal, and sphenoidal sinuses, the proportion of normal results differed significantly between X-ray and CT: 80.2% versus 89%, 76.9% versus 63.7% and 96.7% versus 70.3%, respectively (p <.05). Agreement was over 70% for the maxillary and frontal sinuses. CT also provided a better diagnosis of air-fluid level changes than X-ray. Conclusions. Low-dose CT significantly showed larger number of normal PS results and diagnosed more severe PS lesions. As the determination of true sinus severity lesion impacts in asthma control, low-dose CT may replace PS plain X-ray and conventional CT to support better clinical decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visceral abdominal fat has been associated to cardiovascular risk factors and coronary artery disease (CAD). Computed tomography (CT) coronary angiography is an emerging technology allowing detection of both obstructive and nonobstructive CAD adding information to clinical risk strati. cation. The aim of this study was to evaluate the association between CAD and adiposity measurements assessed clinically and by CT. We prospectively evaluated 125 consecutive subjects (57% men, age 56.0 +/- 12 years) referred to perform CT angiography. Clinical and laboratory variables were determined and CT angiography and abdominal CT were performed in a 64-slice scanner. CAD was defined as any plaque calcified or not detected by CT angiography. Visceral and subcutaneous adiposity areas were determined at different intervertebral levels. CT angiography detected CAD in 70 (56%) subjects, and no association was found with usual anthropometric adiposity measurements (waist and hip circumferences and body mass index). Otherwise, CT visceral fat areas (VFA) were significantly related to CAD. VFA T12-L1 values >= 145 cm(2) had an odds ratio of 2.85 (95% CI 1.30-6.26) and VFA L4-L5 >= 150 cm(2) had a 2.87-fold (95% CI 1.31-6.30) CAD risk. The multivariate analysis determined age and VFA T12-L1 as the only independent variables associated to CAD. Visceral fat assessed by CT is an independent marker of CAD determined by CT angiography. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To assess the cost effectiveness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in patients with Hodgkin`s lymphoma (HL) with unconfirmed complete remission (CRu) or partial remission (PR) after first-line treatment. Patients and Methods One hundred thirty patients with HL were prospectively studied. After treatment, all patients with CRu/PR were evaluated with FDG-PET. In addition, PET-negative patients were evaluated with standard follow-up, and PET-positive patients were evaluated with biopsies of the positive lesions. Local unit costs of procedures and tests were evaluated. Cost effectiveness was determined by evaluating projected annual economic impact of strategies without and with FDG-PET on HL management. Results After treatment, CRu/PR was observed in 50 (40.0%) of the 127 patients; the sensitivity, specificity, and positive and negative predictive values of FDG-PET were 100%, 92.0%, 92.3%, and 100%, respectively (accuracy of 95.9%). Local restaging costs without PET were $350,050 compared with $283,262 with PET, a 19% decrease. The incremental cost-effectiveness ratio is -$3,268 to detect one true case. PET costs represented 1% of total costs of HL treatment. Simulated costs in the 974 patients registered in the 2008 Brazilian public health care database showed that the strategy including restaging PET would have a total program cost of $56,498,314, which is $516,942 less than without restaging PET, resulting in a 1% cost saving. Conclusion FDG-PET demonstrated 95.9% accuracy in restaging for patients with HL with CRu/PR after first-line therapy. Given the observed probabilities, FDG-PET is highly cost effective and would reduce costs for the public health care program in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare SEMG activities during axial load exercises on a stable base of support and on a medicine ball (relatively unstable). Twelve healthy male volunteers were tested (x = 23 +/- 7y). Surface EMG was recorded from the biceps brachii, anterior deltoid, clavicular portion of pectoralis major, upper trapezius and serratus anterior using surface differential electrodes. All SEMG data are reported as percentage of RMS mean values obtained in maximal voluntary contractions for each muscle studied. A 3-way within factor repeated measures analysis of variance was performed to compare RMS normalized values. The RMS normalized values of the deltoid were always greater during the exercises performed on a medicine ball in relation to those performed on a stable base of support. The trapezius showed greater mean electric activation amplitude values on the wall-press exercise on a medicine ball, and the pectoralis major on the push-up. The serratus and biceps did not show significant differences of electric activation amplitude in relation to both tested bases of support. Independent of the base of support, none of the studied muscles showed significant differences of electric activation amplitude during the bench-press exercise. The results contribute to the identification of the levels of muscular activation amplitude during exercises that are common in clinical practice of rehabilitation of the shoulder and the differences in terms of type of base of support used. (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The development of newer diagnostic technologies has reduced the need for invasive electroencephalographic (EEG) studies in identifying the epileptogenic zone, especially in adult patients with mesial temporal lobe epilepsy and hippocampal sclerosis (MTLE-HS). OBJECTIVE: To evaluate ictal single photon emission computed tomography (SPECT) in the evaluation and treatment of patients with MTLE-HS. METHODS: MTLE patients were randomly assigned to those with (SPECT, n = 124) and without ictal SPECT (non-SPECT, n = 116) in an intent-to-treat protocol. Primary end points were the proportion of patients with invasive EEG studies, and those offered surgery. Secondary end points were the length of hospital stay and the proportion of patients with secondarily generalized seizures (SGS) during video-EEG, postsurgical seizure outcome, and hospital cost. RESULTS: The proportion of patients offered surgery was similar in the SPECT (85%) and non-SPECT groups (81%), as well as the proportion that had invasive EEG studies (27% vs 23%). The mean duration of hospital stay was 1 day longer for the SPECT group (P < 0.001). SGS occurred in 51% of the SPECT and 26% of the non-SPECT group (P < 0.001). The cost of the presurgical evaluation was 35% higher for the SPECT compared with the non-SPECT group (P < 0.001). The proportion of patients seizure-free after surgery was similar in the SPECT (59%) compared with non-SPECT group (54%). CONCLUSION: Ictal-SPECT did not add localizing value beyond what was provided by EEG-video telemetry and structural MRI that altered the surgical decision and outcome for MTLE-HS patients. Ictal-SPECT increased hospital stay was associated with increased costs and a higher chance of SGS during video-EEG monitoring. These findings support the notion that a protocol including ictal SPECT is equivalent to one without SPECT in the presurgical evaluation of adult patients with MTLE-HS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Noninvasive assessment of cardiac structure and function is essential to understand the natural course of murine infection with Trypanosoma cruzi. Magnetic resonance imaging (MRI) and echocardiography have been used to monitor anatomy and function; positron emission tomography (PET) is ideal for monitoring metabolic events in the myocardium. Mice infected with T. cruzi (Brazil strain) were imaged 15-100 days post infection (dpi). Quantitative (18)F-FDG microPET imaging, MRI and echocardiography were performed and compared. Tracer ((18)F-FDG) uptake was significantly higher in infected mice at all days of infection, from 15 to 100 dpi. Dilatation of the right ventricular chamber was observed by MRI from 30 to 100 dpi in infected mice. Echocardiography revealed significantly reduced ejection fraction by 60 dpi. Combination of these three complementary imaging modalities makes it possible to noninvasively quantify cardiovascular function, morphology, and metabolism from the earliest days of infection through the chronic phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is virtually no literature on the effect of correction of syndromal faciocraniosynostosis with monobloc advancement on the palpebral fissure shape. Using image processing software, we measured the effect of monobloc advancement on the position of the upper and lower eyelids as well as the palpebral fissure slant in a series of 18 patients with syndromal faciocraniosynostosis who had undergone surgery for correction of orbital and midface hypoplasia. For both eyed of each patient, 3 variables were measured on the pre- and postoperative photographs: the linear distances between the upper and lower eyelid margins, the pupil center and the angle between the inner and outer canthi. The globe protrusion was also measured on axial computed tomography scans before and after surgery. The results indicate that the exorbitism reduction induced by monobloc advancement is accompanied by a diminution of the distance between both eyelids and the pupil center. However, the downward slant of the palpebral fissure is increased after surgery. The data suggest that the lower and upper eyelid retraction seen preoperatively in the majority of patients with faciocraniosynostosis tend to be corrected when the frontofacial region is advanced by the monobloc. On the other hand, the surgery tends to lower the outer canthus, increasing the negative slant of the fissure. The postoperative changes induced by the frontofacial monobloc advancement need to be taken into account when the surgery is going to be performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row computed tomographic coronary angiography (CTCA). We studied five HoFH patients (three females, two males, mean age 19.8 +/- 2.9 years, age range 15-23 years, with a mean low density lipoprotein (LDL) cholesterol 618 +/- 211 mg/dL) using 64 slice CTCA. None of the patients showed evidence of ischemia with standard exercise testing. Calcified and mixed atherosclerotic plaques adjacent to or compromising the coronary artery ostia were found in all study subjects. Coronary plaques causing significant obstruction were found in one patient, who had previously undergone coronary artery bypass surgery and aortic valve replacement. Two other patients were noted to have non-obstructive calcified, mixed and non-calcified coronary artery plaques. Our data suggest that CTCA could be a useful non-invasive method for detection of early aortic and coronary atherosclerosis specifically affecting the coronary ostia in HoFH subjects. (c) 2007 Elsevier Ireland Ltd. All rights reserved.