907 resultados para Clinical analysis. Near-infrared spectroscopy. Multivariate calibration


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis some multivariate spectroscopic methods for the analysis of solutions are proposed. Spectroscopy and multivariate data analysis form a powerful combination for obtaining both quantitative and qualitative information and it is shown how spectroscopic techniques in combination with chemometric data evaluation can be used to obtain rapid, simple and efficient analytical methods. These spectroscopic methods consisting of spectroscopic analysis, a high level of automation and chemometric data evaluation can lead to analytical methods with a high analytical capacity, and for these methods, the term high-capacity analysis (HCA) is suggested. It is further shown how chemometric evaluation of the multivariate data in chromatographic analyses decreases the need for baseline separation. The thesis is based on six papers and the chemometric tools used are experimental design, principal component analysis (PCA), soft independent modelling of class analogy (SIMCA), partial least squares regression (PLS) and parallel factor analysis (PARAFAC). The analytical techniques utilised are scanning ultraviolet-visible (UV-Vis) spectroscopy, diode array detection (DAD) used in non-column chromatographic diode array UV spectroscopy, high-performance liquid chromatography with diode array detection (HPLC-DAD) and fluorescence spectroscopy. The methods proposed are exemplified in the analysis of pharmaceutical solutions and serum proteins. In Paper I a method is proposed for the determination of the content and identity of the active compound in pharmaceutical solutions by means of UV-Vis spectroscopy, orthogonal signal correction and multivariate calibration with PLS and SIMCA classification. Paper II proposes a new method for the rapid determination of pharmaceutical solutions by the use of non-column chromatographic diode array UV spectroscopy, i.e. a conventional HPLC-DAD system without any chromatographic column connected. In Paper III an investigation is made of the ability of a control sample, of known content and identity to diagnose and correct errors in multivariate predictions something that together with use of multivariate residuals can make it possible to use the same calibration model over time. In Paper IV a method is proposed for simultaneous determination of serum proteins with fluorescence spectroscopy and multivariate calibration. Paper V proposes a method for the determination of chromatographic peak purity by means of PCA of HPLC-DAD data. In Paper VI PARAFAC is applied for the decomposition of DAD data of some partially separated peaks into the pure chromatographic, spectral and concentration profiles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phase 1: To validate Near-Infrared Reflectance Analysis (NIRA) as a fast, reliable and suitable method for routine evaluation of human milk’s nitrogen and fat content. Phase 2: To determine whether fat content, protein content and osmolality of HM before and after fortification may affect gastroesophageal reflux (GER) in symptomatic preterm infants. Patients and Methods: Phase 1: 124 samples of expressed human milk (55 from preterm mothers and 69 from term mothers) were used to validate NIRA against traditional methods (Gerber method for fat and Kjeldhal method for nitrogen). Phase 2: GER was evaluated in 17 symptomatic preterm newborns fed naïve and fortified HM by combined pH/intraluminal-impedance monitoring (pH-MII). HM fat and protein content was analysed by a Near-Infrared-Reflectance-Analysis (NIRA). HM osmolality was tested before and after fortification. GER indexes measured before and after fortification were compared, and were also related with HM fat and protein content and osmolality before and after fortification. Results: Phase 1: · A strong agreement was found between traditional methods’ and NIRA’s results (expressed as g/100 g of milk), both for fat and nitrogen content in term (mean fat content: NIRA=2.76; Gerber=2.76; mean nitrogen content: NIRA=1.88; Kjeldhal =1.92) and preterm (mean fat content: NIRA=3.56; Kjeldhal=3.52; mean nitrogen content: NIRA=1.91; Kjeldhal =1.89) mother’s milk. · Nitrogen content of the milk samples, measured by NIRA, ranged from 1.18 to 2.71 g/100 g of milk in preterm milk and from 1.48 to 2.47 in term milk; fat content ranged from 1.27 to 6.23 g/100 g of milk in preterm milk and from 1.01 to 6.01 g/100 g of milk in term milk. Phase 2: · An inverse correlation was found between naïve HM protein content and acid reflux index (RIpH: p=0.041, rho=-0.501). · After fortification, osmolality often exceeded the values recommended for infant feeds; furthermore, a statistically significant (p<.05) increase in non acid reflux indexes was observed. Conclusions: NIRA can be used as a fast, reliable and suitable tool for routine monitoring of macronutrient content of human milk. Protein content of naïve HM may influence acid GER in preterm infants. A standard fortification of HM may worsen non acid GER indexes and, due to the extreme variability in HM composition, may overcome both recommended protein intake and HM osmolality. Thus, an individualized fortification, based on the analysis of the composition of naïve HM, could optimize both nutrient intake and feeding tolerance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

FIR spectroscopy is an alternative way of collecting spectra of many inorganic pigments and corrosion products found on art objects, which is not normally observed in the MIR region. Most FIR spectra are traditionally collected in transmission mode but as a real novelty it is now also possible to record FIR spectra in ATR (Attenuated Total Reflectance) mode. In FIR transmission we employ polyethylene (PE) for preparation of pellets by embedding the sample in PE. Unfortunately, the preparation requires heating of the PE in order to produces at transparent pellet. This will affect compounds with low melting points, especially those with structurally incorporated water. Another option in FIR transmission is the use of thin films. We test the use of polyethylene thin film (PETF), both commercial and laboratory-made PETF. ATR collection of samples is possible in both the MIR and FIR region on solid, powdery or liquid samples. Changing from the MIR to the FIR region is easy as it simply requires the change of detector and beamsplitter (which can be performed within a few minutes). No preparation of the sample is necessary, which is a huge advantage over the PE transmission method. The most obvious difference, when comparing transmission with ATR, is the distortion of band shape (which appears asymmetrical in the lower wavenumber region) and intensity differences. However, the biggest difference can be the shift of strong absorbing bands moving to lower wavenumbers in ATR mode. The sometimes huge band shift necessitates the collection of standard library spectra in both FIR transmission and ATR modes, provided these two methods of collecting are to be employed for analyses of unknown samples. Standard samples of 150 pigment and corrosion compounds are thus collected in both FIR transmission and ATR mode in order to build up a digital library of spectra for comparison with unknown samples. XRD, XRF and Raman spectroscopy assists us in confirming the purity or impurity of our standard samples. 24 didactic test tables, with known pigment and binder painted on the surface of a limestone tablet, are used for testing the established library and different ways of collecting in ATR and transmission mode. In ATR, micro samples are scratched from the surface and examined in both the MIR and FIR region. Additionally, direct surface contact of the didactic tablets with the ATR crystal are tested together with water enhanced surface contact. In FIR transmission we compare the powder from our test tablet on the laboratory PETF and embedded in PE. We also compare the PE pellets collected using a 4x beam condenser, focusing the IR beam area from 8 mm to 2 mm. A few samples collected from a mural painting in a Nepalese temple, corrosion products collected from archaeological Chinese bronze objects and samples from a mural paintings in an Italian abbey, are examined by ATR or transmission spectroscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Perforating arteries are commonly involved during the surgical dissection and clipping of intracranial aneurysms. Occlusion of perforating arteries is responsible for ischemic infarction and poor outcome. The goal of this study is to describe the usefulness of near-infrared indocyanine green videoangiography (ICGA) for the intraoperative assessment of blood flow in perforating arteries that are visible in the surgical field during clipping of intracranial aneurysms. In addition, we analyzed the incidence of perforating vessels involved during the aneurysm surgery and the incidence of ischemic infarct caused by compromised small arteries. METHODS: Sixty patients with 64 aneurysms were surgically treated and prospectively included in this study. Intraoperative ICGA was performed using a surgical microscope (Carl Zeiss Co., Oberkochen, Germany) with integrated ICGA technology. The presence and involvement of perforating arteries were analyzed in the microsurgical field during surgical dissection and clip application. Assessment of vascular patency after clipping was also investigated. Only those small arteries that were not visible on preoperative digital subtraction angiography were considered for analysis. RESULTS: The ICGA was able to visualize flow in all patients in whom perforating vessels were found in the microscope field. Among 36 patients whose perforating vessels were visible on ICGA, 11 (30%) presented a close relation between the aneurysm and perforating arteries. In one (9%) of these 11 patients, ICGA showed occlusion of a P1 perforating artery after clip application, which led to immediate correction of the clip confirmed by immediate reestablishment of flow visible with ICGA without clinical consequences. Four patients (6.7%) presented with postoperative perforating artery infarct, three of whom had perforating arteries that were not visible or distant from the aneurysm. CONCLUSION: The involvement of perforating arteries during clip application for aneurysm occlusion is a usual finding. Intraoperative ICGA may provide visual information with regard to the patency of these small vessels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reproduced from typewritten copy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present Spitzer IRS mid-infrared spectra for 15 gravitationally lensed, 24 μm-selected galaxies, and combine the results with four additional very faint galaxies with IRS spectra in the literature. The median intrinsic 24 μm flux density of the sample is 130 μJy, enabling a systematic survey of the spectral properties of the very faint 24 μm sources that dominate the number counts of Spitzer cosmological surveys. Six of the 19 galaxy spectra (32%) show the strong mid-IR continuua expected of AGNs; X-ray detections confirm the presence of AGNs in three of these cases, and reveal AGNs in two other galaxies. These results suggest that nuclear accretion may contribute more flux to faint 24 μm-selected samples than previously assumed. Almost all the spectra show some aromatic (PAH) emission features; the measured aromatic flux ratios do not show evolution from z = 0. In particular, the high signal-to-noise mid-IR spectrum of SMM J163554.2+661225 agrees remarkably well with low-redshift, lower luminosity templates. We compare the rest-frame 8 μm and total infrared luminosities of star-forming galaxies, and find that the behavior of this ratio with total IR luminosity has evolved modestly from z = 2 to z = 0. Since the high aromatic-to-continuum flux ratios in these galaxies rule out a dominant contribution by AGNs, this finding implies systematic evolution in the structure and/or metallicity of infrared sources with redshift. It also has implications for the estimates of star-forming rates inferred from 24 μm measurements, in the sense that at z ~ 2, a given observed frame 24 μm luminosity corresponds to a lower bolometric luminosity than would be inferred from low-redshift templates of similar luminosity at the corresponding rest wavelength.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dolomite mineral samples having white and light green colours of Indian origin have been characterized by EPR, optical and NIR spectroscopy. The optical spectrum exhibits a number of electronic bands due to presence of Fe(III) ions in the mineral. From EPR studies, the parameters of g for Fe(III) and g, A and D for Mn(II) are evaluated and the data confirm that the ions are in distorted octahedron. Optical absorption studies reveal that Fe(III) is in distorted octahedron. The bands in NIR spectra are due to the overtones and combinations of water molecules. Thus EPR and optical absorption spectral studies have proven useful for the study of the chemistry of dolomite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mottramite mineral originated from Tsumeb Corporation Mine, Tsumeb, Otavi, Namibia, is used in the present work. The mineral contains of vanadium and copper to the extent of 22.73% and 16.84% by weight respectively as V2O5 and CuO. An EPR study of sample confirms the presence of Cu(II) with g = 2.2. Optical absorption spectrum of mottramite indicates that Cu(II) is present in rhombic environment. NIR results are due to water fundamentals.