926 resultados para Capacitor voltage equalization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC converters are now available. Using these new resources we developed a new electrical stimulus isolator circuit with selectable constant-current and constant-voltage modes, which are precise and easy to construct. The circuit works like a regulated power supply in both modes with output switched to zero or to free mode through an opto-isolator device. The isolator analyses showed good practical performance. The output to ground resistance was 1011 ohms and capacitance 35 picofarads. The rise time and fall time were identical (5 µs) and constant. The selectable voltage or current output mode made it very convenient to use. The current mode, with higher output resistance values in low current ranges, permits intracellular stimulation even with tip resistances close to 100 megaohms. The high compliance of 200 V guarantees the value of the current stimulus. The very low output resistance in the voltage mode made the device highly suitable for extracellular stimulation with low impedance electrodes. Most importantly, these characteristics were achieved with a circuit that was easy to build and modify and assembled with components available in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of the skin secretion of the amphibian Siphonops paulensis was investigated by monitoring the changes in conductance of an artificial planar lipid bilayer. Skin secretion was obtained by exposure of the animals to ether-saturated air, and then rinsing the animals with distilled water. Artificial lipid bilayers were obtained by spreading a solution of azolectin over an aperture of a Delrin cup inserted into a cut-away polyvinyl chloride block. In 9 of 12 experiments, the addition of the skin secretion to lipid bilayers displayed voltage-dependent channels with average unitary conductance of 258 ± 41.67 pS, rather than nonspecific changes in bilayer conductance. These channels were not sensitive to 4-acetamido-4'-isothiocyanatostilbene-2,2'-disulfonic acid or tetraethylammonium ion, but the experimental protocol used does not permit us to specify their characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today, renewable energy technologies and modern power electronics have made it feasible to implement low voltage direct current (LVDC) microgrids (MGs) ca-pable to island operation. Such LVDC networks are particularly useful in remote areas. However, there are still pending issues in island operated LVDC MGs like electrical safety and controlled operation, which should be addressed before wide-scale implementation. This thesis is focused on the overall protection of an island operated LVDC network concept, including protection against electrical shocks, mains equipment protection and protection of photovoltaic (PV) power sources and battery energy storage systems (BESSs). The topic is approached through ex-amination of the safety hazards and the appropriate methods to protect against them, comprising considerations for earthing system selection and realisation of the protection system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preventive maintenance of frequency converters has been based on pre-planned replace-ment of wearing or ageing components. Exchange intervals follow component life-time expectations which are based on empirical knowledge or schedules defined by manufac-turer. However, the lifetime of a component can vary significantly, because drives are used in very different operating environments and applications. The main objective of the research was to provide information on methods, i.e. how in-verter's operating condition can be measured reliably under field conditions. At first, the research focused on critical components such as current transducers, IGBTs and DC link capacitor bank, because these aging have already been identified. Of these, the DC link capacitor measurement method was selected for closer examination. With this method, the total capacitance and its total series resistance can be measured. The suitability of the measuring procedure was estimated on the basis of practical measurements. The research was made by using so called triangulation method, including a literature review, simulations and practical measurements. Based on the results, the new measu-rement method seems suitable with some reservations to practical measurements. How-ever, the measuring method should be further developed in order to improve its reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this bachelor’s thesis are examined the benefits of current distortion detection device application in customer premises low voltage networks. The purpose of this study was to find out if there are benefits for measuring current distortion in low-voltage residential networks. Concluding into who can benefit from measuring the power quality. The research focuses on benefits based on the standardization in Europe and United States of America. In this research, were also given examples of appliances in which current distortion detection device could be used. Along with possible illustration of user interface for the device. The research was conducted as an analysis of the benefits of current distortion detection device in residential low voltage networks. The research was based on literature review. The study was divided to three sections. The first explain the reasons for benefitting from usage of the device and the second portrays the low-cost device, which could detect one-phase current distortion, in theory. The last section discuss of the benefits of usage of current distortion detection device while focusing on the beneficiaries. Based on the result of this research, there are benefits from usage to the current distortion detection device. The main benefitting party of the current distortion detection device was found to be manufactures, as they are held responsible of limiting the current distortion on behalf of consumers. Manufactures could adjust equipment to respond better to the distortion by having access to on-going current distortion in network. The other benefitting party are system operators, who would better locate distortion issues in low-voltage residential network to start prevention of long-term problems caused by current distortion early on.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power line modelling has become an interesting research area in recent years as a result of advances in the power line distribution network system. Extensive knowledge about the power line cable characteristics can be implemented in a software algorithm in a modern broadband power-line communication modem. In this study, a novel approach for modelling power line cables (AMCMK) based on the broadband impedance spectroscopy (BIS) and transmission line matrix (TLM) techniques is recommended in characterizing a healthy cable and the various faults associated with low-voltage cables for both open and short circuit situation. Models for different cable conditions are developed and tuned, which include six models for both healthy and faulty cables situations. The models are on the basis of impedance response analysis of the cable. The resulting spectra from the simulations are also cross-correlated to determine the degree of similarities between the healthy cable spectra and their respective faulty spectra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis ( Maestro en Ciencias de la Ingeniería Mecánica, con Especialidad en Térmica y Fluidos) UANL, 2002

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Orientación en Química de los Materiales) UANL, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the conditions under which an inequality averse and additively separable welfarist constitution maker would always choose to set up a progressive equalization payments scheme in a federation with local public goods. A progressive equalization payments scheme is defined as a list of per capita net (possibly negative) subsidies - one such net subsidy for every jurisdiction - that are decreasing with respect to jurisdictions per capita wealth. We examine these questions in a setting in which the case for progressivity is a priori the strongest, namely, all citizens have the same utility function for the private and the public goods, inhabitants of a given jurisdiction are all identical, and they are not able to move across jurisdictions. We show that the constitution maker favors a progressive equalization payments scheme for all distributions of wealth and all population sizes if and only if its objective function is additively separable between each jurisdiction’s per capita wealth and number of inhabitants. When interpreted as a mean of order r social welfare function, this condition is shown to be equivalent to additive separability of the individual’s indirect utility function with respect to wealth and the price of the public good. Some implications of this restriction to the case where the individual’s direct utility function is additively separable are also derived.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de recherche

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les canaux potassiques dépendants du voltage sont formés de quatre sous-unités, chacune possédant six segments transmembranaires (S1-S6) et une boucle (p-loop) qui se trouve entre le cinquième et le sixième segment au niveau du pore. Il est connu que le segment senseur du voltage (S1-S4) subit un mouvement lorsque le potentiel membranaire change. Pour ouvrir le canal, il est nécessaire de transférer l'énergie du senseur du voltage (généré par le mouvement des charges positives de S4) au pore. Le mécanisme exact de ce couplage électromécanique est encore sous étude. Un des points de liaison entre le senseur de voltage et le pore est le lien physique fait par le segment S4-S5 (S45L). Le but de cette étude est de déterminer l'influence de la flexibilité du segment S45L sur le processus de couplage. Dans le S45L, trois glycines sont distribuées dans des positions différentes. Elles sont responsables de la flexibilité des hélices-alpha. Ces glycines (mais pas leurs positions exactes) sont conservées pour tous les canaux potassiques dépendants de potentiel. En utilisant la technique de mutagènes dirigé, la glycine a été remplacée dans chacune de ces différentes positions par une alanine et dans une deuxième étape, par une proline (pour introduire un angle dans l'hélice). Pour étudier le comportement des canaux dans cette nouvelle conformation, on a appliqué la technique de « patch clamp » pour déterminer les effets lors de l'ouverture du pore (courant ionique). Avec le « cut-open oocyte voltage-clamp », nous avons étudié les effets sur le mouvement du senseur de voltage (courant “gating”) et la coordination temporelle avec l'ouverture du pore (courant ionique). Les données ont montré qu’en réduisant la flexibilité dans le S45L, il faut avoir plus d'énergie pour faire ouvrir le canal. Le changement pour une proline suggère que le mouvement du senseur est indépendant du pore pendant l'ouverture du canal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les canaux potassiques voltage-dépendants forment des tétramères dont chaque sous-unité comporte six segments transmembranaires (S1 à S6). Le pore, formé des segments S5-S6 de chaque sous-unité, est entouré de quatre domaines responsables de la sensibilité au potentiel membranaire, les senseurs de voltage (VS; S1-S4). Lors d’une dépolarisation membranaire, le mouvement des résidus chargés situés dans le VS entraine un mouvement de charges détectable en électrophysiologie, le courant de « gating ». L’activation du VS conduit à l'ouverture du pore, qui se traduit par un changement de conformation en C-terminal du segment S6. Pour élucider les principes qui sous-tendent le couplage électromécanique entre ces deux domaines, nous avons étudié deux régions présumées responsables du couplage chez les canaux de type Shaker K+, soit la région carboxy-terminale du segment S6 et le lien peptidique reliant les segments transmembranaire S4-S5 (S4-5L). Avec la technique du « cut-open voltage clamp fluorometry » (COVCF), nous avons pu déterminer que l’interaction inter-sous-unitaire RELY, formée par des acides aminés situés sur le lien S4-5L et S6 de deux sous-unités voisines, est impliquée dans le développement de la composante lente observée lors du retour des charges de « gating » vers leur état de repos, le « OFF-gating ». Nous avons observé que l’introduction de mutations dans la région RELY module la force de ces interactions moléculaires et élimine l’asymétrie observée dans les courants de « gating » de type sauvage. D’ailleurs, nous démontrons que ce couplage inter-sous-unitaire est responsable de la stabilisation du pore dans l’état ouvert. Nous avons également identifié une interaction intra-sous-unitaire entre les résidus I384 situé sur le lien S4-5L et F484 sur le segment S6 d’une même sous-unité. La déstabilisation de cette interaction hydrophobique découple complètement le mouvement des senseurs de voltage et l'ouverture du pore. Sans cette interaction, l’énergie nécessaire pour activer les VS est moindre en raison de l’absence du poids mécanique appliqué par le pore. De plus, l’abolition du couplage électromécanique élimine également le « mode shift », soit le déplacement de la dépendance au voltage des charges de transfert (QV) vers des potentiels hyperpolarisants. Ceci indique que le poids mécanique du pore imposé au VS entraine le « mode shift », en modulant la conformation intrinsèque du VS par un processus allostérique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les ataxies épisodiques (EA) d’origine génétique sont un groupe de maladies possédant un phénotype et génotype hétérogènes, mais ont en commun la caractéristique d’un dysfonctionnement cérébelleux intermittent. Les EA de type 1 et 2 sont les plus largement reconnues des ataxies épisodiques autosomiques dominantes et sont causées par un dysfonctionnement des canaux ioniques voltage-dépendants dans les neurones. La présente étude se concentrera sur les mutations causant l'EA-1, retrouvées dans le senseur de voltage (VSD) de Kv1.1, un canal très proche de la famille des canaux Shaker. Nous avons caractérisé les propriétés électrophysiologiques de six mutations différentes à la position F244 et partiellement celles des mutations T284 A/M, R297 K/Q/A/H, I320T, L375F, L399I et S412 C/I dans la séquence du Shaker grâce à la technique du ‘’cut open voltage clamp’’ (COVC). Les mutations de la position F244 situées sur le S1 du canal Shaker sont caractérisées par un décalement des courbes QV et GV vers des potentiels dépolarisants et modifient le couplage fonctionnel entre le domaine VSD et le pore. Un courant de fuite est observé durant la phase d'activation des courants transitoires et peut être éliminé par l'application du 4-AP (4-aminopyridine) ou la réinsertion de l'inactivation de type N mais pas par le TEA (tétraéthylamonium). Dans le but de mieux comprendre les mécanismes moléculaires responsables de la stabilisation d’un état intermédiaire, nous avons étudié séparément la neutralisation des trois premières charges positives du S4 (R1Q, R2Q et R3Q). Il en est ressorti l’existence d’une interaction entre R2 et F244. Une seconde interface entre S1 et le pore proche de la surface extracellulaire agissant comme un second point d'ancrage et responsable des courants de fuite a été mis en lumière. Les résultats suggèrent une anomalie du fonctionnement du VSD empêchant la repolarisation normale de la membrane des cellules nerveuses affectées à la suite d'un potentiel d'action.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La fonction des canaux ioniques est finement régulée par des changements structuraux de sites clés contrôlant l’ouverture du pore. Ces modulations structurales découlent de l’interaction du canal avec l’environnement local, puisque certains domaines peuvent être suffisamment sensibles à des propriétés physico-chimiques spécifiques. Les mouvements engendrés dans la structure sont notamment perceptibles fonctionnellement lorsque le canal ouvre un passage à certains ions, générant ainsi un courant ionique mesurable selon le potentiel électrochimique. Une description détaillée de ces relations structure-fonction est cependant difficile à obtenir à partir de mesures sur des ensembles de canaux identiques, puisque les fluctuations et les distributions de différentes propriétés individuelles demeurent cachées dans une moyenne. Pour distinguer ces propriétés, des mesures à l’échelle de la molécule unique sont nécessaires. Le but principal de la présente thèse est d’étudier la structure et les mécanismes moléculaires de canaux ioniques par mesures de spectroscopie de fluorescence à l’échelle de la molécule unique. Les études sont particulièrement dirigées vers le développement de nouvelles méthodes ou leur amélioration. Une classe de toxine formeuse de pores a servi de premier modèle d’étude. La fluorescence à l’échelle de la molécule unique a aussi été utilisée pour l’étude d’un récepteur glutamate, d’un récepteur à la glycine et d’un canal potassique procaryote. Le premier volet porte sur l’étude de la stœchiométrie par mesures de photoblanchiment en temps résolu. Cette méthode permet de déterminer directement le nombre de monomères fluorescents dans un complexe isolé par le décompte des sauts discrets de fluorescence suivant les événements de photoblanchiment. Nous présentons ici la première description, à notre connaissance, de l’assemblage dynamique d’une protéine membranaire dans un environnement lipidique. La toxine monomérique purifiée Cry1Aa s’assemble à d’autres monomères selon la concentration et sature en conformation tétramérique. Un programme automatique est ensuite développé pour déterminer la stœchiométrie de protéines membranaires fusionnées à GFP et exprimées à la surface de cellules mammifères. Bien que ce système d’expression soit approprié pour l’étude de protéines d’origine mammifère, le bruit de fluorescence y est particulièrement important et augmente significativement le risque d’erreur dans le décompte manuel des monomères fluorescents. La méthode présentée permet une analyse rapide et automatique basée sur des critères fixes. L’algorithme chargé d’effectuer le décompte des monomères fluorescents a été optimisé à partir de simulations et ajuste ses paramètres de détection automatiquement selon la trace de fluorescence. La composition de deux canaux ioniques a été vérifiée avec succès par ce programme. Finalement, la fluorescence à l’échelle de la molécule unique est mesurée conjointement au courant ionique de canaux potassiques KcsA avec un système de fluorométrie en voltage imposé. Ces enregistrements combinés permettent de décrire la fonction de canaux ioniques simultanément à leur position et densité alors qu’ils diffusent dans une membrane lipidique dont la composition est choisie. Nous avons observé le regroupement de canaux KcsA pour différentes compositions lipidiques. Ce regroupement ne paraît pas être causé par des interactions protéine-protéine, mais plutôt par des microdomaines induits par la forme des canaux reconstitués dans la membrane. Il semble que des canaux regroupés puissent ensuite devenir couplés, se traduisant en ouvertures et fermetures simultanées où les niveaux de conductance sont un multiple de la conductance « normale » d’un canal isolé. De plus, contrairement à ce qui est actuellement suggéré, KcsA ne requiert pas de phospholipide chargé négativement pour sa fonction. Plusieurs mesures indiquent plutôt que des lipides de forme conique dans la phase cristalline liquide sont suffisants pour permettre l’ouverture de canaux KcsA isolés. Des canaux regroupés peuvent quant à eux surmonter la barrière d’énergie pour s’ouvrir de manière coopérative dans des lipides non chargés de forme cylindrique.