987 resultados para CT angiography
Resumo:
We assessed the prevalence of vertebral artery (VA) stenosis or occlusion and its influence on outcome in patients with acute basilar artery occlusion (BAO). We studied 141 patients with acute BAO enrolled in the Basilar Artery International Cooperation Study (BASICS) registry of whom baseline CT angiography (CTA) of the intracranial VAs was available. In 72 patients an additional CTA of the extracranial VAs was available. Adjusted risk ratios (aRRs) for death and poor outcome, defined as a modified Rankin Scale score ≥4, were calculated with Poisson regression in relation to VA occlusion, VA occlusion or stenosis ≥50 %, and bilateral VA occlusion. Sixty-six of 141 (47 %) patients had uni- or bilateral intracranial VA occlusion or stenosis ≥50 %. Of the 72 patients with intra- and extracranial CTA, 46 (64 %) had uni- or bilateral VA occlusion or stenosis ≥50 % and 9 (12 %) had bilateral VA occlusion. Overall, VA occlusion or stenosis ≥50 % was not associated with the risk of poor outcome. Patients with intra- and extracranial CTA and bilateral VA occlusion had a higher risk of poor outcome than patients without bilateral VA occlusion (aRR, 1.23; 95 % CI 1.02-1.50). The risk of death did not depend on the presence of unilateral or bilateral VA occlusion or stenosis ≥50 %. In conclusion, in patients with acute BAO, unilateral VA occlusion or stenosis ≥50 % is frequent, but not associated with an increased risk of poor outcome or death. Patients with BAO and bilateral VA occlusion have a slightly increased risk of poor outcome.
Resumo:
OBJECTIVE This study aims to report the management of patients with spontaneous isolated dissection of the abdominal aorta (sIAAD). METHODS A cohort of 18 consecutive patients (12 male, mean age 58 years) with sIAAD was treated between 1990 and 2009. Dissection was asymptomatic in ten and symptomatic in eight patients. Retrospective data analysis from patient charts was performed. Follow-up included clinical examination, ultrasound, and/or CT-angiography. Mean follow-up was 54 months (range 1-211). RESULTS In total, eight out of 18 received invasive treatment. All asymptomatic patients initially underwent conservative treatment and surveillance. Spontaneous false lumen thrombosis occurred in four (40 %), and three patients showed relevant aneurysmatic progression and underwent elective invasive treatment (open n = 2, endovascular n = 1), representing a crossover rate of 30 %. Late mortality was 20 % (n = 2) in this group. In symptomatic patients, five underwent urgent treatment due to persistent abdominal or back pain (n = 4) or contained rupture (n = 1); one was treated for claudication. The remaining two patients presented with irreversible spinal cord ischemia and were treated conservatively. Three patients were treated by open surgery and three by endovascular interventions (two stentgrafts, one Palmaz XXL stent). Early and late morbidity and mortality was 0 % in this group. There were no reinterventions CONCLUSION: The majority of patients with sIADD require invasive treatment, with EVAR being the preferable treatment option today. In asymptomatic IADD, primary surveillance is justifiable, but close surveillance due to expansion is necessary.
Resumo:
PURPOSE The purpose of this study was to identify morphologic factors affecting type I endoleak formation and bird-beak configuration after thoracic endovascular aortic repair (TEVAR). METHODS Computed tomography (CT) data of 57 patients (40 males; median age, 66 years) undergoing TEVAR for thoracic aortic aneurysm (34 TAA, 19 TAAA) or penetrating aortic ulcer (n = 4) between 2001 and 2010 were retrospectively reviewed. In 28 patients, the Gore TAG® stent-graft was used, followed by the Medtronic Valiant® in 16 cases, the Medtronic Talent® in 8, and the Cook Zenith® in 5 cases. Proximal landing zone (PLZ) was in zone 1 in 13, zone 2 in 13, zone 3 in 23, and zone 4 in 8 patients. In 14 patients (25%), the procedure was urgent or emergent. In each case, pre- and postoperative CT angiography was analyzed using a dedicated image processing workstation and complimentary in-house developed software based on a 3D cylindrical intensity model to calculate aortic arch angulation and conicity of the landing zones (LZ). RESULTS Primary type Ia endoleak rate was 12% (7/57) and subsequent re-intervention rate was 86% (6/7). Left subclavian artery (LSA) coverage (p = 0.036) and conicity of the PLZ (5.9 vs. 2.6 mm; p = 0.016) were significantly associated with an increased type Ia endoleak rate. Bird-beak configuration was observed in 16 patients (28%) and was associated with a smaller radius of the aortic arch curvature (42 vs. 65 mm; p = 0.049). Type Ia endoleak was not associated with a bird-beak configuration (p = 0.388). Primary type Ib endoleak rate was 7% (4/57) and subsequent re-intervention rate was 100%. Conicity of the distal LZ was associated with an increased type Ib endoleak rate (8.3 vs. 2.6 mm; p = 0.038). CONCLUSIONS CT-based 3D aortic morphometry helps to identify risk factors of type I endoleak formation and bird-beak configuration during TEVAR. These factors were LSA coverage and conicity within the landing zones for type I endoleak formation and steep aortic angulation for bird-beak configuration.
Resumo:
Les artéfacts métalliques entraînent un épaississement artéfactuel de la paroi des tuteurs en tomodensitométrie (TDM) avec réduction apparente de leur lumière. Cette étude transversale prospective, devis mesures répétées et observateurs avec méthode en aveugle, chez 24 patients consécutifs/71 tuteurs coronariens a pour objectif de comparer l’épaisseur de paroi des tuteurs en TDM après reconstruction par un algorithme avec renforcement des bords et un algorithme standard. Une angiographie coronarienne par TDM 256 coupes a été réalisée, avec reconstruction par algorithmes avec renforcement des bords et standard. L’épaisseur de paroi des tuteurs était mesurée par méthodes orthogonale (diamètres) et circonférentielle (circonférences). La qualité d’image des tuteurs était évaluée par échelle ordinale, et les données analysées par modèles linéaire mixte et régression logistique des cotes proportionnelles. L’épaisseur de paroi des tuteurs était inférieure avec l’algorithme avec renforcement des bords comparé à l’algorithme standard, avec les méthodes orthogonale (0,97±0,02 vs 1,09±0,03 mm, respectivement; p<0,001) et circonférentielle (1,13±0,02 vs 1,21±0,02 mm, respectivement; p<0,001). Le premier causait moins de surestimation par rapport à l’épaisseur nominale comparé au second, avec méthodes orthogonale (0,89±0,19 vs 1,00±0,26 mm, respectivement; p<0,001) et circonférentielle (1,06±0,26 vs 1,13±0,31 mm, respectivement; p=0,005) et diminuait de 6 % la surestimation. Les scores de qualité étaient meilleurs avec l’algorithme avec renforcement des bords (OR 3,71; IC 95% 2,33–5,92; p<0,001). En conclusion, la reconstruction des images avec l’algorithme avec renforcement des bords génère des parois de tuteurs plus minces, moins de surestimation, et de meilleurs scores de qualité d’image que l’algorithme standard.
Resumo:
Objectives: We present an atypical case of chronic mesenteric ischemia with weight loss as only clinical manifestation and endoscopic findings imitating Crohn´s disease. Materials and Methods: A CT Angiography of abdomen confirmed the diagnosis of mesenteric ischemia after total occlusion of celiac trunk and superior mesenteric artery. Results: The patient died due to severe sepsis, as a result of extended bowel infarction. Conclusions: The diagnosis of chronic mesenteric ischemia requires a high degree of clinical suspicion and can be life-saving if early conducted.
Resumo:
Introduction: The incidence of vertebral artery (VA) injury during cervical spine surgery is rare. Even though tamponade is effective in many cases, early consultation of an endovascular team is recommended if bleeding cannot be controlled. We report a case of emergent endovascular embolisation of left VA due to iatrogenic injury during anterior cervical disc removal and fusion. Case: A 47-year-old woman was admitted to our emergency department with serious arterial bleeding from the neck only hours after undergoing anterior cervical disc removal and fusion surgery. She was intubated and mechanically ventilated, however hemorrhage could not be successfully controlled by packing with surgical hemostatic agents. Cranial computed tomography, computed tomography of the cervical spine and CT angiography confirmed the suspected diagnosis of injury to the VA. Emergent endovascular embolisation successfully stopped the bleeding. Occlusion of the vessel was achieved by vascular plugging. The patient was discharged from our hospital 14 days after the intervention, receiving a revision surgery of the cervical spine on the day of embolisation. At the date of discharge she presented without any focal neurological deficit. Conclusion: Pre-operative radiographic imaging of the cervical spine should be used routinely to identify anatomic abnormalities of the vertebral arteries. Endovascular embolisation appears to be effective in treating acute iatrogenic dissection of the vertebral arteries.
Resumo:
Introduction: Intravenous thrombolysis in acute ischaemic stroke with alteplase improves clinical outcomes, but it has limited efficacy and is associated with increased risk of intracranial haemorrhage. An improved tissue plasminogen activator, tenecteplase, was evidenced to be at least equally effective with lower risk of haemorrhage in acute myocardial infarction thrombolysis. To date, two completed phase II randomised controlled studies comparing tenecteplase and alteplase in acute ischaemic strokes showed variable results. Methods: A literature review of thrombolytic agents used in myocardial infarction and acute ischaemic stroke was performed, followed by a retrospective investigation of the bolus-to- infusion delay of alteplase administration. The main focus of this thesis is the report of our single centre phase II randomised controlled trial that compared tenecteplase (0.25mg/kg, maximum 25mg) and alteplase (0.9mg/kg, maximum 90mg, 10% as the initial bolus, following by one hour infusion with the rest of the dose) in acute ischaemic stroke thrombolysis using advanced imaging as biomarkers. Imaging comprised baseline computed tomography (CT), CT perfusion (CTP) and CT angiography (CTA), and CT+CTA at 24-48 hours. The primary end-point was penumbral salvage (CTP-defined penumbra volume minus follow-up CT infarct volume). A sub-study of coagulation and fibrinolysis analysis of the two agents was performed by comparing a group of coagulation variables measured pre-treatment, 3-12 hours, and 24±3 hours post thrombolysis. An individual patient data (IPD) meta-analysis was carried out using all three completed tenecteplase/alteplase comparison studies in stroke thrombolysis. We compared clinical outcomes including modified Rankin scale at 3 months, early neurological improvement at 24 hours, intracerebral haemorrhage rate and mortality at 3 months between all three tenecteplase doses (0.1mg/kg, 0.25 mg/kg, and 0.4mg/kg) examined and standard alteplase. Imaging outcomes including penumbra salvage, recanalisation rates were also compared using the data from the two studies that had advance imaging carried out. Results: Delay between the initial bolus and the subsequent infusion in administration of alteplase is common. This may reduce the likelihood of achieving a good functional outcome. Among the 104 patients recruited in ATTEST trial, 71 contributed to the imaging primary outcome. No significant differences were observed for penumbral salvage [68 (SD 28) % tenecteplase vs 68 (SD 23) % alteplase], mean difference 1% (95% confidence interval -10%, 12%, p=0·81) or for any secondary end-point. The SICH incidence (1/52, 2% vs 2/51, 4%, by SITS-MOST definition, p=0·55; by ECASS-2 definition, 3/52, 6% tenecteplase vs 4/51, 8% alteplase, p=0.59) did not differed significantly. There was a trend towards lower ICH risk in the tenecteplase group (8/52 tenecteplase, 15% vs 14/51 alteplase, 29%, p=0·091). Compared to baseline, alteplase caused significant hypofibrinogenaemia (p=0.002), prolonged Prothrombin Time (PT) (p=0.011), hypoplasminogenaemia (p=0.001) and lower Factor V (p=0.002) at 3-12 hours after administration with persistent hypofibrinogenaemia at 24h (p=0.011), while only minor hypoplasminogenaemia (P=0.029) was seen in the tenecteplase group. Tenecteplase consumed less plasminogen (p<0.001) and fibrinogen (p=0.002) compared with alteplase. In a pooled analysis, tenecteplase 0.25mg/kg had the greatest odds to achieve early neurological improvement (OR [95%CI] 3.3 [1.5, 7.2], p=0.093), excellent functional outcome (mRS 0-1) at three months (OR [95%CI] 1.9 [0.8, 4.4], p= 0.28), with reduced odds of ICH (OR [95%CI] 0.6 [0.2, 1.8], P=0.43) compared with alteplase. Only 19 patients were treated with tenecteplase 0.4mg/kg, which showed increased odds of SICH compared with alteplase (OR [95% CI] 6.2 [0.7, 56.3]). In the two studies where advanced imaging was performed, the imaging outcomes did not differ in the IPD analysis. Conclusion: Tenecteplase 0.25 mg/kg has the potential to be a better alternative to alteplase. It can be given as a single bolus, does not cause disruption to systemic coagulation, and is possibly safer and more effective in clot lysis. Further phase III study to compare tenecteplase and alteplase in acute ischaemic stroke is warranted.
Resumo:
International audience
Resumo:
Lo scopo dell’AngioTC è quello di ottenere un’opacizzazione adeguata del comparto vascolare esaminato, sincronizzata all’acquisizione della scansione TC. La distribuzione del mezzo di contrasto (mdc) e l’opacizzazione dei distretti corporei, definita enhancement, è influenzata da diversi fattori: relativi al paziente, al mdc o allo scanner TC. In Medicina Veterinaria sono presenti pochi studi indirizzati a valutare l’influenza di diversi fattori sull’enhancement. La ricerca è stata condotta seguendo le linee guida PRISMA (Preferred Reporting Items for Systematic Reviews, 2020). Il database online di diversi motori di ricerca scientifici (Web of Science, PubMed, Scopus e CABAbstract) è stato esaminato mediante combinazione di diverse parole chiave. Sono stati individuati 20 studi che rispettavano i criteri di inclusione, inseriti nel corpo finale della revisione sistematica e raggruppati sulla base della categoria di appartenenza. Si è visto come la quantità di tessuto adiposo addominale sull’enhancement rappresenti un fattore che permette di ridurre la dose di mezzo di contrasto utilizzato, riducendo effetti avversi o tossicità sull’animale. Per quanto riguarda l’iniezione del mdc, un fattore in grado di influenzare maggiormente l’enhancement sembra essere la velocità di trasporto dello Iodio, piuttosto che la durata di iniezione, soprattutto a livello arterioso ed epatico. Con uno scanner lento o una durata di scansione lunga, è consigliato utilizzare una durata fissa di iniezione del mdc per l’acquisizione delle diverse fasi vascolari. Al contrario, con scanner più performanti la tecnica di bolus tracking garantisce una maggior qualità tra le varie fasi vascolari. È indicato, infine, eseguire un flush con soluzione fisiologica al termine della somministrazione di mdc per incrementare l’enhancement arterioso e ridurre la dose di mdc somministrata. Questa revisione sistematica mette in evidenza alcuni fattori e può fare da base per l’ulteriore approfondimento di alcuni di questi fattori o per la valutazione altri non ancora esaminati in Medicina Veterinaria.
Resumo:
Objectives: Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods: 50 patients (aged 41-82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered "significant". Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm(3) were utilised and Pearson's correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results: Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate-strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm(3) was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion: This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a "score" that could predict high grade stenosis.
Resumo:
To identify reasons for ordering computed tomography pulmonary angiography (CTPA), to identify the frequency of reasons for CTPA reflecting defensive behavior and evidence-based behavior, and to identify the impact of defensive medicine and of training about diagnosing pulmonary embolism (PE) on positive results of CTPA.
Resumo:
A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.
Resumo:
PURPOSE: To prospectively assess the depiction rate and morphologic features of myocardial bridging (MB) of coronary arteries with 64-section computed tomographic (CT) coronary angiography in comparison to conventional coronary angiography. MATERIALS AND METHODS: Patients were simultaneously enrolled in a prospective study comparing CT and conventional coronary angiography, for which ethics committee approval and informed consent were obtained. One hundred patients (38 women, 62 men; mean age, 63.8 years +/- 11.6 [standard deviation]) underwent 64-section CT and conventional coronary angiography. Fifty additional patients (19 women, 31 men; mean age, 59.2 years +/- 13.2) who underwent CT only were also included. CT images were analyzed for the direct signs length, depth, and degree of systolic compression, while conventional angiograms were analyzed for the indirect signs step down-step up phenomenon, milking effect, and systolic compression of the tunneled segment. Statistical analysis was performed with Pearson correlation analysis, the Wilcoxon two-sample test, and Fisher exact tests. RESULTS: MB was detected with CT in 26 (26%) of 100 patients and with conventional angiography in 12 patients (12%). Mean tunneled segment length and depth at CT (n = 150) were 24.3 mm +/- 10.0 and 2.6 mm +/- 0.8, respectively. Systolic compression in the 12 patients was 31.3% +/- 11.0 at CT and 28.2% +/- 10.5 at conventional angiography (r = 0.72, P < .001). With CT, a significant correlation was not found between systolic compression and length (r = 0.16, P = .25, n = 150) but was found with depth (r = 0.65, P < .01, n = 150) of the tunneled segment. In 14 patients in whom MB was found at CT but not at conventional angiography, length, depth, and systolic compression were significantly lower than in patients in whom both modalities depicted the anomaly (P < .001, P < .01, and P < .001, respectively). CONCLUSION: The depiction rate of MB is greater with 64-section CT coronary angiography than with conventional coronary angiography. The degree of systolic compression of MB significantly correlates with tunneled segment depth but not length.