981 resultados para CR superconducting magnet


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis introduces a search for a new design of the frame for a permanent magnet generator mounted at a windmill. The objective of this work is to offer new design ideas for the stator frame - new concepts for connecting stator core to stator frame in a generator. Desired aims of new design concepts are: simplification of the structure production; decrease of material use; use of standard components; light weight of construction and etc. Thesis contains several new possible designs for the stator frame structure. Also, it has a list of possible connection concepts, which can be used to join the stator to the frame. All new ideas are described and compared according to its match to the desired purposes of the work. New design concepts are modeled using modern software. The main part of the Thesis contains several approximate computer models of the current and new offered constructions, description of loads and stress in the current stator frame. It has evaluation of the most important stress and load characteristics. The final design is a result of all previous research. It has a description of a new frame structure and joining concept for it. This structure matched main aims of work, but it does not have detailed design with dimensions and check calculations of the frame and welds. Thesis gives representation about design search, evaluation and comparison of new concepts of generator structure. Also, it gives general representation of renewable energy technology, knowledge about windmill turbines and its contents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concentrated winding permanent magnet machines and their electromagnetic properties are studied in this doctoral thesis. The thesis includes a number of main tasks related to the application of permanent magnets in concentrated winding open slot machines. Suitable analytical methods are required for the first design calculations of a new machine. Concentrated winding machines differ from conventional integral slot winding machines in such a way that adapted analytical calculation methods are needed. A simple analytical model for calculating the concentrated winding axial flux machines is provided. The next three main design tasks are discussed in more detail in the thesis. The magnetic length of the rotor surface magnet machines is studied, and it is shown that the traditional methods have to be modified also in this respect. An important topic in this study has been to evaluate and minimize the rotor permanent magnet Joule losses by using segmented magnets in the calculations and experiments. Determination of the magnetizing and leakage inductances for a concentrated winding machine and the torque production capability of concentrated winding machines with different pole pair numbers are studied, and the results are compared with the corresponding properties of integral slot winding machines. The thesis introduces a new practical permanent magnet motor type for industrial use. The special features of the machine are based on the option of using concentrated winding open slot constructions of permanent magnet synchronous machines in the normal speed ranges of industrial motors, for instance up to 3000 min-1, without excessive rotor losses. By applying the analytical equations and methods introduced in the thesis, a 37 kW 2400 min-1 12-slot 10-pole axial flux machine with rotor-surfacemounted magnets is designed. The performance of the designed motor is determined by experimental measurements and finite element calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the use of wild animal hair of C. brachyurus, C. thous and L. pardalis as biomonitors of trace metal at Parque Nacional das Emas, Brazil. Results reveal a strong correlation between Cd and Pb as well as Cu and Zn, which suggests a single source of emission. Most metals showed a lower or equal concentration than those obtained in previous studies. The research shows that monitoring may be performed only with Zn, Pb, Cd, and Cr because of statistical similarity and of a non-natural occurrence of large amounts of the material under analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess a new monitoring technique of particulate and trace metals in the atmosphere via the use of a passive sampler of air pollutants in the city of Goiânia. The average particulate weight and average concentrations of metals Fe, Cr, Zn, Pb, Cu, Mn, and Cd were 0.1104 g and 257.5; 23.4; 17.8; 6.7; 1.9; 0.8; 0.2 μg/m²/day, respectively. Higher Pb and Cr concentrations were obtained in areas with intense traffic. This study revealed that it is possible to monitor trace metals with passive sampling, developed at a low cost and operational facility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The synthesis and characterization of crosslinked chitosan microbeads and their application in the removal of Cr(VI) are described. New kinetic and thermodynamic parameters of Cr(VI) adsorptions processes were found using continuous isothermal calorimetry. All adsorption processes are exothermic in nature. However, a multivariate statistical analysis have pointed out that adsorption enthalpies were affected by important binary interactions of the initial Cr(VI) in solution and temperature. The adsorption energetic data were well fitted to a kinetic exponential model, which have indicated fractionary adsorption kinetic orders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clay mineral montmorillonite-K10 (MT), treated under acidic medium and saturated with potassium ions (MTK), was employed in sorption and desorption studies aiming the preconcentration of Cr(III) and the speciation analysis of chromium. The sorption process of Cr(III) was close to 100%, suggesting that MTK was a good material for Cr(III) preconcentration, although, the maximum recovery in HNO3 solution was near 89%. On the other hand, Cr(VI) practically was not retained in MTK, suggesting this material as an appropriate mineral phase to be used in speciation analysis of chromium in aqueous medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procedure for the simultaneous determination of Cr, Ni, and V in urine by electrothermal atomic absorption spectrometry (ET AAS) was optimized by factorial design, and performed at a pyrolysis and atomization temperatures of 1300 and 2500 ºC, respectively, using 15 µg de Mg(NO3)2 as chemical modifier. Characteristics mass of 14, 6 and 220 ρg and detection limits of the method of 0.07, 0.38 and 0.75 µg L-1 were obtained for Cr, Ni and V respectively. The methodology was validated using a Liphochek Urine Metals Control sample (Bio-Rad) (P=0.05). The methodology was applied to samples of voluntary Venezuelan people, not environmentally exposed to specific emissions, and results ranging from < LOD-1.1 and 1.3-3.3 µg L-1 was observed for Cr and V, respectively, and not detectable levels for Ni.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trace metal content of three fish species harvested from a tank located in the City of Guarapuava-PR, Brazil were determined by digestion and voltametry. Trace metal content in fish samples were 0.10-1.30 µg/g (muscle) and 0.45-15.90 µg/g (liver) for chromium, 0.35-2.56 µg/g (muscle) and 2.32-34.30 µg/g (liver) for lead. The levels of lead and chromium in fish samples were higher than the recommended legal limits for human consumption. To assess the dietary intake of Cr and Pb by fish, weekly intake was calculated based on average metals contents and weekly consumption of fish and it compared with PTWI (Provisional Tolerable Weekly Intake). The Cr and Pb have achieved up to 25 and 45%, respectively, of PTWI recommended by WHO/FAO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A spectrophotometric method for the indirect determination of captopril (CP) in pharmaceutical formulations is proposed. The proposed procedure is based on the oxidation of captopril by potassium dichromate and the determination excess oxidant on the basis of its reaction with diphenylcarbazide (DPC). Under the optimum conditions, a good linear relationship (r = 0.9997) was obtained in the range of 0.08-3.5 µg mL-1. The assay limits of detection and quantitation were 0.024 and 0.08 µg mL-1, respectively. The results obtained for captopril determination in pharmaceuticals using the proposed method and those obtained with the US Pharmacopoeia method were in good agreement at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adsorption of Cr(VI) in aqueous solution by magnetic particles of crosslinked chitosan-ethylenediamine-Fe(III) (MPCh-EDA-FeCL) was studied in a batch system. Fe3+ in the MPCh-EDA-FeCL permitted that adsorption of Cr(VI) occurred with maximum efficiency between pH 3 and 11. The maximum adsorption capacity at pH 7.0 was 81.04 mg g-1 at 25 ºC. The adsorption kinetic process was described by the pseudo-second-order model. Thermodynamic parameters indicated spontaneous, exothermic and chemical adsorption nature. The adsorbent was successively regenerated using a 0.1 mol L-1 NaOH solution. Results were satisfactory for treatment of wastewater from the electroplating industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Mg-vacancy binding free enthalpy of Al-Cr solid solution alloys with Mg addition was calculated by electrical resistivity measurements. The obtained value is lower than that obtained for dilute Al-Mg alloys with almost the same Mg content and may be attributed to the diffusion of Mg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudou-se a distribuição de Cr, Ni, Cu, Cd e Pb em frações de substâncias húmicas (SH) de diferentes tamanhos moleculares. As SH foram extraídas de amostras de água (SHA) e de sedimentos de superfície (SHSS), interface/água (SHSI) e fundo (SHSF) coletados no reservatório de captação de água superficial Anhumas, localizado no município de Araraquara-SP. Para a extração das SH utilizaram-se os procedimentos recomendados pela Sociedade Internacional de Substâncias Húmicas. Após purificação por diálise, as SH foram fracionadas com base no tamanho molecular utilizando-se sistema de fracionamento seqüencial por ultrafiltração e fluxo tangencial. O fracionamento das amostras de SHA permitiu caracterizar uma distribuição de massa relativamente uniforme dentre as frações de diferentes tamanhos moleculares, com valores maiores nas frações F2 (20,8%) e F4 (23,8%). Exceto para os íons Pb(II) e Cu(II) os quais apresentaram concentrações relativamente mais altas nas frações F2 e F4, respectivamente, de maneira geral, crômio, níquel, cádmio e chumbo têm distribuições similares nas cinco frações com tamanhos moleculares maiores e médios (F1 a F5). Quanto às distribuições de massa nas diferentes frações de substâncias húmicas extraídas de amostras de sedimento de superfície (SHSS), sedimento interface/água (SHSI) e sedimento de fundo (SHSF), as três amostras apresentaram 42-48% das SH nas frações com maiores tamanhos moleculares (F1 e F2), 29-31% nas frações intermediárias (F3 e F4) e 13-20% nas frações com menores tamanhos moleculares (F5 e F6). De modo geral, caracterizaram-se para os íons metálicos, distribuições similares dentre as respectivas frações F1 a F6. Exceções para Pb(II) e Ni(II) em sedimento de superfície com concentrações relativamente menores nas frações F2 e F4, respectivamente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The lability of Cd(II), Cr(III), Cu(II), Mn(II) and Pb(II) complexed by humic substances (HSs) was investigated by means of ion exchange on cellulose modified with p-aminobenzoic groups (Cell-PAB), using a batch procedure. The HSs were extracted from water samples using adsorption in a column packed with XAD 8 resin. The metal-HS complexes were prepared by adding solutions containing all the aforementioned metal ions ( Cd(II), Cr(III), Cu(II), Mn(II) and Pb(II) ). The results indicated that the distribution coefficients (Kd) of Cell-PAB decreased with the presence of HSs, and that the lability of metal fractions complexed by HSs decreases in pH values > 4.0, complexation time > 10 h and HS concentration > 500 mg L-1. The metal exchange between HSs and Cell-PAB exhibited the following order of metal ion lability: Cd < Pb < Mn @ Cr < Cu.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this thesis is to describe hybrid drive design problems, the advantages and difficulties related to the drive. A review of possible hybrid constructions, benefits of parallel, series and series-parallel hybrids is done. In the thesis analytical and finite element calculations of permanent magnet synchronous machines with embedded magnets were done. The finite element calculations were done using Cedrat’s Flux 2D software. This machine is planned to be used as a motor-generator in a low power parallel hybrid vehicle. The boundary conditions for the design were found from Lucas-TVS Ltd., India. Design Requirements, briefly: • The system DC voltage level is 120 V, which implies Uphase = 49 V (RMS) in a three phase system. • The power output of 10 kW at base speed 1500 rpm (Torque of 65 Nm) is desired. • The maximum outer diameter should not be more than 250 mm, and the maximum core length should not exceed 40 mm. The main difficulties which the author met were the dimensional restrictions. After having designed and analyzed several possible constructions they were compared and the final design selected. Dimensioned and detailed design is performed. Effects of different parameters, such as the number of poles, number of turns and magnetic geometry are discussed. The best modification offers considerable reduction of volume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to font problem on the tilte field the titlte of the thesis is corrected here. The title of the thesis is: Superconducting properties and their enhancement in ReBa2Cu3O7-delta (RE = Y and Gd) films prepared by pulsed laser deposition