986 resultados para CONTINUOUS POSITIVE AIRWAY PRESSURE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Cyclic recruitment and derecruitment of atelectasis can occur during mechanical ventilation, especially in injured lungs. Experimentally, cyclic recruitment and derecruitment can be quantified by respiration-dependent changes in PaO2 (ΔPaO2), reflecting the varying intrapulmonary shunt fraction within the respiratory cycle. This study investigated the effect of inspiration to expiration ratio upon ΔPaO2 and Horowitz index. DESIGN Prospective randomized study. SETTING Laboratory investigation. SUBJECTS Piglets, average weight 30 ± 2 kg. INTERVENTIONS At respiratory rate 6 breaths/min, end-inspiratory pressure (Pendinsp) 40 cm H2O, positive end-expiratory pressure 5 cm H2O, and FIO2 1.0, measurements were performed at randomly set inspiration to expiration ratios during baseline healthy and mild surfactant depletion injury. Lung damage was titrated by repetitive surfactant washout to induce maximal cyclic recruitment and derecruitment as measured by multifrequency phase fluorimetry. Regional ventilation distribution was evaluated by electrical impedance tomography. Step changes in airway pressure from 5 to 40 cm H2O and vice versa were performed after lavage to calculate PO2-based recruitment and derecruitment time constants (TAU). MEASUREMENTS AND MAIN RESULTS In baseline healthy, cyclic recruitment and derecruitment could not be provoked, whereas in model acute respiratory distress syndrome, the highest ΔPaO2 were routinely detected at an inspiration to expiration ratio of 1:4 (range, 52-277 torr [6.9-36.9 kPa]). Shorter expiration time reduced cyclic recruitment and derecruitment significantly (158 ± 85 torr [21.1 ± 11.3 kPa] [inspiration to expiration ratio, 1:4]; 25 ± 12 torr [3.3 ± 1.6 kPa] [inspiration to expiration ratio, 4:1]; p < 0.0001), whereas the PaO2/FIO2 ratio increased (267 ± 50 [inspiration to expiration ratio, 1:4]; 424 ± 53 [inspiration to expiration ratio, 4:1]; p < 0.0001). Correspondingly, regional ventilation redistributed toward dependent lung regions (p < 0.0001). Recruitment was much faster (TAU: fast 1.6 s [78%]; slow 9.2 s) than derecruitment (TAU: fast 3.1 s [87%]; slow 17.7 s) (p = 0.0078). CONCLUSIONS Inverse ratio ventilation minimizes cyclic recruitment and derecruitment of atelectasis in an experimental model of surfactant-depleted pigs. Time constants for recruitment and derecruitment, and regional ventilation distribution, reflect these findings and highlight the time dependency of cyclic recruitment and derecruitment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The geographically constrained distribution of Epstein-Barr virus (EBV)-associated nasopharyngeal carcinoma (NPC) in southeast Asian populations suggests that both viral and host genetics may influence disease risk. Although susceptibility loci have been mapped within the human genome, the role of viral genetics in the focal distribution of NPC remains an enigma. Here we report a molecular phylogenetic analysis of an NPC-associated viral oncogene, LMP1, in a large panel of EBV isolates from southeast Asia and from Papua New Guinea, Africa, and Australia, regions of the world where NPC is and is not endemic, respectively. This analysis revealed that LMP1 sequences show a distinct geographic structure, indicating that the southeast Asian isolates have evolved as a lineage distinct from those of Papua New Guinea, African, and Australian isolates. Furthermore, a likelihood ratio test revealed that the C termini of the LMP1 sequences of the southeast Asian lineage are under significant positive selection pressure, particularly at some sites within the C-terminal activator regions. We also present evidence that although the N terminus and transmembrane region of LMP1 have undergone recombination, the C-terminal region of the gene has evolved without any history of recombination. Based on these observations, we speculate that selection pressure may be driving the LMP1 sequences in virus isolates from southeast Asia towards a more malignant phenotype, thereby influencing the endemic distribution of NPC in this region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: La ventilation non invasive (VNI) est un outil utilisé en soins intensifs pédiatriques (SIP) pour soutenir la détresse respiratoire aigüe. Un échec survient dans près de 25% des cas et une mauvaise synchronisation patient-ventilateur est un des facteurs impliqués. Le mode de ventilation NAVA (neurally adjusted ventilatory assist) est asservi à la demande ventilatoire du patient. L’objectif de cette étude est d’évaluer la faisabilité et la tolérance des enfants à la VNI NAVA et l’impact de son usage sur la synchronie et la demande respiratoire. Méthode: Étude prospective, physiologique, croisée incluant 13 patients nécessitant une VNI dans les SIP de l’hôpital Ste-Justine entre octobre 2011 et mai 2013. Les patients ont été ventilés successivement en VNI conventionnelle (30 minutes), en VNI NAVA (60 minutes) et en VNI conventionnelle (30 minutes). L’activité électrique du diaphragme (AEdi) et la pression des voies aériennes supérieures ont été enregistrées pour évaluer la synchronie. Résultats: La VNI NAVA est faisable et bien tolérée chez tous les enfants. Un adolescent a demandé l’arrêt précoce de l’étude en raison d’anxiété reliée au masque sans fuite. Les délais inspiratoires et expiratoires étaient significativement plus courts en VNI NAVA comparativement aux périodes de VNI conventionnelle (p< 0.05). Les efforts inefficaces étaient moindres en VNI NAVA (résultats présentés en médiane et interquartiles) : 0% (0 - 0) en VNI NAVA vs 12% (4 - 20) en VNI conventionnelle initiale et 6% (2 - 22) en VNI conventionnelle finale (p< 0.01). Globalement, le temps passé en asynchronie a été réduit à 8% (6 - 10) en VNI NAVA, versus 27% (19 - 56) et 32% (21 - 38) en périodes de VNI conventionnelle initiale et finale, respectivement (p= 0.05). Aucune différence en termes de demande respiratoire n’a été observée. Conclusion: La VNI NAVA est faisable et bien tolérée chez les enfants avec détresse respiratoire aigüe et permet une meilleure synchronisation patient-ventilateur. De plus larges études sont nécessaires pour évaluer l’impact clinique de ces résultats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: La ventilation non invasive (VNI) est un outil utilisé en soins intensifs pédiatriques (SIP) pour soutenir la détresse respiratoire aigüe. Un échec survient dans près de 25% des cas et une mauvaise synchronisation patient-ventilateur est un des facteurs impliqués. Le mode de ventilation NAVA (neurally adjusted ventilatory assist) est asservi à la demande ventilatoire du patient. L’objectif de cette étude est d’évaluer la faisabilité et la tolérance des enfants à la VNI NAVA et l’impact de son usage sur la synchronie et la demande respiratoire. Méthode: Étude prospective, physiologique, croisée incluant 13 patients nécessitant une VNI dans les SIP de l’hôpital Ste-Justine entre octobre 2011 et mai 2013. Les patients ont été ventilés successivement en VNI conventionnelle (30 minutes), en VNI NAVA (60 minutes) et en VNI conventionnelle (30 minutes). L’activité électrique du diaphragme (AEdi) et la pression des voies aériennes supérieures ont été enregistrées pour évaluer la synchronie. Résultats: La VNI NAVA est faisable et bien tolérée chez tous les enfants. Un adolescent a demandé l’arrêt précoce de l’étude en raison d’anxiété reliée au masque sans fuite. Les délais inspiratoires et expiratoires étaient significativement plus courts en VNI NAVA comparativement aux périodes de VNI conventionnelle (p< 0.05). Les efforts inefficaces étaient moindres en VNI NAVA (résultats présentés en médiane et interquartiles) : 0% (0 - 0) en VNI NAVA vs 12% (4 - 20) en VNI conventionnelle initiale et 6% (2 - 22) en VNI conventionnelle finale (p< 0.01). Globalement, le temps passé en asynchronie a été réduit à 8% (6 - 10) en VNI NAVA, versus 27% (19 - 56) et 32% (21 - 38) en périodes de VNI conventionnelle initiale et finale, respectivement (p= 0.05). Aucune différence en termes de demande respiratoire n’a été observée. Conclusion: La VNI NAVA est faisable et bien tolérée chez les enfants avec détresse respiratoire aigüe et permet une meilleure synchronisation patient-ventilateur. De plus larges études sont nécessaires pour évaluer l’impact clinique de ces résultats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mechanisms contributing to pulmonary and systemic injury induced by high tidal volume (VT) mechanical ventilation are not well known. We tested the hypothesis that increased peroxynitrite formation is involved in organ injury and dysfunction induced by mechanical ventilation. Male Sprague-Dawley rats were subject to low- (VT, 9 mL/kg; positive end-expiratory pressure, 5 cmH2O) or high- (VT, 25 mL/kg; positive end-expiratory pressure, 0 cmH2O) VT mechanical ventilation for 120 min, and received 1 of 3 treatments: 3-aminobenzamide (3-AB, 10 mg/kg, intravenous, a poly adenosine diphosphate ribose polymerase [PARP] inhibitor), or the metalloporphyrin manganese(III) tetrakis(1-methyl-4-pyridyl)porphyrin (MnTMPyP, 5 mg/kg intravenous, a peroxynitrite scavenger), or no treatment (control group), 30 min before starting the mechanical ventilation protocol (n = 8 per group, 6 treatment groups). We measured mean arterial pressure, peak inspiratory airway pressure, blood chemistry, and gas exchange. Oxidation (fluorescence for oxidized dihydroethidium), protein nitration (immunofluorescence and Western blot for 3-nitrotyrosine), PARP protein (Western blot) and gene expression of the nitric oxide (NO) synthase (NOS) isoforms (quantitative real-time reverse transcription polymerase chain reaction) were measured in lung and vascular tissue. Lung injury was quantified by light microscopy. High-VT mechanical ventilation was associated with hypotension, increased peak inspiratory airway pressure, worsened oxygenation; oxidation and protein nitration in lung and aortic tissue; increased PARP protein in lung; up-regulation of NOS isoforms in lung tissue; signs of diffuse alveolar damage at histological examination. Treatment with 3AB or MnTMPyP attenuated the high-VT mechanical ventilation-induced changes in pulmonary and cardiovascular function; down-regulated the expression of NOS1, NOS2, and NOS3; decreased oxidation and nitration in lung and aortic tissue; and attenuated histological changes. Increased peroxynitrite formation is involved in mechanical ventilation-induced pulmonary and vascular dysfunction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Over-ventilation causing low arterial carbon dioxide levels (PaCO2) has been associated with the development of neonatal chronic lung disease and adverse outcomes. This may occur very soon after birth. Aim: To investigate the effect on PaCO2 and oxygenation of very premature lambs resuscitated with different tidal volumes and PEEP. Methods: Anaesthetised lambs delivered at 126 days gestation were randomised to 15 min resuscitation with 3 regimes: (1) Laerdal resuscitation bag (B) with 100% oxygen and no PEEP, (2) fixed tidal volume (VT) of 5 mL/kg, or (3) VT of 10 mL/kg, both delivered with a Babylog 8000 ventilator in volume guarantee mode with 8 cm H2O PEEP and variable FiO2. Frequent blood gases were measured and VT, mean airway pressure (Paw), minute volume (MV), ventilation rate (VR), respiratory system compliance (Crs) and alveolar/arterial oxygen difference (AaDO2) were recorded. Results: Twenty lambs were studied. B (1) was associated with more variable VT and peak inspiratory pressures (PIP) compared to fixed tidal volumes (2 and 3). The lambs ventilated with 10 mL/kg were over-ventilated, those ventilated with 5 mL/kg were slightly under-ventilated. Those ventilated with the Laerdal bag had a mean VT of 7.5 mL/kg and were normocarbic. The different tidal volumes had little effect on oxygenation. PEEP improved oxygenation. The table shows the values at 15 minutes expressed as mean and SEM. TABLE. No caption av... TABLE. No caption av... Image Tools Conclusion: Very premature lambs can be effectively resuscitated from birth using volume guarantee ventilation. Within minutes of birth different tidal volumes had a large effect on PaCO2 and no effect on oxygenation. Studies are needed to determine the appropriate tidal volume for resuscitating very premature infants to maintain acceptable levels of PaCO2. © International Pediatrics Research Foundation, Inc. 2004. All Rights Reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of prolonged recruitment manoeuvre (PRM) were compared with sustained inflation (SI) in paraquat-induced mild acute lung injury (ALI) in rats. Twenty-four hours after ALI induction, rats were anesthetized and mechanically ventilated with VT = 6 ml/kg and positive end-expiratory pressure (PEEP) = 5 cmH(2)O for 1 h. SI was performed with an instantaneous pressure increase of 40 cmH(2)O that was sustained for 40 s, while PRM was done by a step-wise increase in positive inspiratory pressure (PIP) of 15-20-25 cmH(2)O above a PEEP of 15 cm H(2)O (maximal PIP = 40 cmH(2)O), with interposed periods of PIP = 10 cmH(2)O above a PEEP = 15 cmH(2)O. Lung static elastance and the amount of alveolar collapse were more reduced with PRM than SI, yielding improved oxygenation. Additionally, tumour necrosis factor-alpha, interleukin-6, interferon-gamma, and type III procollagen mRNA expressions in lung tissue and lung epithelial cell apoptosis decreased more in PRM. In conclusion, PRM improved lung function, with less damage to alveolar epithelium, resulting in reduced pulmonary injury. (C) 2009 Elsevier BLV. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Few prospective data from the Asia Pacific region are available relating body mass index to the risk of diabetes. Our objective was to provide reliable age, sex and region specific estimates of the associations between body mass index and diabetes. Twenty-seven cohort studies from Asia, New Zealand and Australia, including 154,989 participants, contributed 1,244,793 person-years of follow-up. Outcome data included a combination of incidence of diabetes (based on blood glucose measurements) and fatal diabetes events. Hazard ratios were calculated from Cox models, stratified by sex and cohort, and adjusted for age at risk and smoking. During follow-up (mean = 8 years), 75 fatal diabetes events and 242 new cases of diabetes were documented. There were continuous positive associations between baseline body mass index and risk of diabetes with each 2 kg/m(2) lower body mass index associated with a 27% (23-30%) lower risk of diabetes. The associations were stronger in younger age groups, and regional comparisons demonstrated slightly stronger associations in Asian than in Australasian cohorts (P = 0.04). This overview provides evidence of a strong continuous association between body mass index and diabetes in the Asia Pacific region. The results indicate considerable potential for reduction in incidence of diabetes with population-wide lowering of body mass index in this region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the triggering performance of mid-level ICU mechanical ventilators with a standard ICU mechanical ventilator. Design: Experimental bench study. Setting: The respiratory care laboratory of a university-affiliated teaching hospital. Subject: A computerized mechanical lung model, the IngMar ASL5000. Interventions: Ten mid-level ICU ventilators were compared to an ICU ventilator at two levels of lung model effort, three combinations of respiratory mechanics (normal, COPD and ARDS) and two modes of ventilation, volume and pressure assist/control. A total of 12 conditions were compared. Measurements and main results: Performance varied widely among ventilators. Mean inspiratory trigger time was < 100 ms for only half of the tested ventilators. The mean inspiratory delay time (time from initiation of the breath to return of airway pressure to baseline) was longer than that for the ICU ventilator for all tested ventilators except one. The pressure drop during triggering (Ptrig) was comparable with that of the ICU ventilator for only two ventilators. Expiratory Settling Time (time for pressure to return to baseline) had the greatest variability among ventilators. Conclusions: Triggering differences among these mid-level ICU ventilators and with the ICU ventilator were identified. Some of these ventilators had a much poorer triggering response with high inspiratory effort than the ICU ventilator. These ventilators do not perform as well as ICU ventilators in patients with high ventilatory demand.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The Flutter (R) VRP1 combines high frequency oscillation and positive expiratory pressure (PEP). Objective: To separately evaluate the effect of the Flutter (R) VRP1 components (high frequency oscillation and PEP) on mucus transportability in patients with bronchiectasis. Methods: Eighteen patients with bronchiectasis received sessions with the Flutter (R) VRP1 or PEP for 30 min daily in a randomized, crossover study. The treatment duration was four weeks with one of the therapies, one week of a ""wash-out"" period and followed by four more weeks with the other treatment. Weekly secretion samples were collected and evaluated for mucociliary relative transport velocity (RTV), displacement in a simulated cough machine (SCM) and contact angle measurement (CAM). For the proposed comparisons, a linear regression model was used with mixed effects with a significance level of 5%. Results: The Flutter (R) VRP1 treatment resulted in greater displacement in SCM and lower CAM when comparing results from the first (9.6 +/- 3.4 cm and 29.4 +/- 5.7 degrees, respectively) and fourth weeks of treatment (12.44 +/- 10.5 cm and 23.28 +/- 6.2, respectively; p < 0.05). There was no significant difference in the RTV between the treatment weeks for either the Flutter (R) VRP1 or PEP. Conclusion: The use of the Flutter (R) VRP1 for four weeks is capable of altering the respiratory secretion transport properties, and this alteration is related to the high frequency oscillation component. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neurally adjusted ventilatory assist (NAVA) is a ventilation assist mode that delivers pressure in proportionality to electrical activity of the diaphragm (Eadi). Compared to pressure support ventilation (PS), it improves patient-ventilator synchrony and should allow a better expression of patient's intrinsic respiratory variability. We hypothesize that NAVA provides better matching in ventilator tidal volume (Vt) to patients inspiratory demand. 22 patients with acute respiratory failure, ventilated with PS were included in the study. A comparative study was carried out between PS and NAVA, with NAVA gain ensuring the same peak airway pressure as PS. Robust coefficients of variation (CVR) for Eadi and Vt were compared for each mode. The integral of Eadi (ʃEadi) was used to represent patient's inspiratory demand. To evaluate tidal volume and patient's demand matching, Range90 = 5-95 % range of the Vt/ʃEadi ratio was calculated, to normalize and compare differences in demand within and between patients and modes. In this study, peak Eadi and ʃEadi are correlated with median correlation of coefficients, R > 0.95. Median ʃEadi, Vt, neural inspiratory time (Ti_ ( Neural )), inspiratory time (Ti) and peak inspiratory pressure (PIP) were similar in PS and NAVA. However, it was found that individual patients have higher or smaller ʃEadi, Vt, Ti_ ( Neural ), Ti and PIP. CVR analysis showed greater Vt variability for NAVA (p < 0.005). Range90 was lower for NAVA than PS for 21 of 22 patients. NAVA provided better matching of Vt to ʃEadi for 21 of 22 patients, and provided greater variability Vt. These results were achieved regardless of differences in ventilatory demand (Eadi) between patients and modes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE : To determine the prevalence of patient-ventilator asynchrony in patients receiving non-invasive ventilation (NIV) for acute respiratory failure. DESIGN : Prospective multicenter observation study. SETTING : Intensive care units in three university hospitals. METHODS: Patients consecutively admitted to ICU were included. NIV, performed with an ICU ventilator, was set by the clinician. Airway pressure, flow, and surface diaphragmatic electromyography were recorded continuously for 30 min. Asynchrony events and the asynchrony index (AI) were determined from visual inspection of the recordings and clinical observation. RESULTS: A total of 60 patients were included, 55% of whom were hypercapnic. Auto-triggering was present in 8 (13%) patients, double triggering in 9 (15%), ineffective breaths in 8 (13%), premature cycling 7 (12%) and late cycling in 14 (23%). An AI > 10%, indicating severe asynchrony, was present in 26 patients (43%), whose median (25-75 IQR) AI was 26 (15-54%). A significant correlation was found between the magnitude of leaks and the number of ineffective breaths and severity of delayed cycling. Multivariate analysis indicated that the level of pressure support and the magnitude of leaks were weakly, albeit significantly, associated with an AI > 10%. Patient comfort scale was higher in pts with an AI < 10%. CONCLUSION: Patient-ventilator asynchrony is common in patients receiving NIV for acute respiratory failure. Our results suggest that leaks play a major role in generating patient-ventilator asynchrony and discomfort, and point the way to further research to determine if ventilator functions designed to cope with leaks can reduce asynchrony in the clinical setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine if, compared to pressure support (PS), neurally adjusted ventilatory assist (NAVA) reduces patient-ventilator asynchrony in intensive care patients undergoing noninvasive ventilation with an oronasal face mask. METHODS: In this prospective interventional study we compared patient-ventilator synchrony between PS (with ventilator settings determined by the clinician) and NAVA (with the level set so as to obtain the same maximal airway pressure as in PS). Two 20-min recordings of airway pressure, flow and electrical activity of the diaphragm during PS and NAVA were acquired in a randomized order. Trigger delay (T(d)), the patient's neural inspiratory time (T(in)), ventilator pressurization duration (T(iv)), inspiratory time in excess (T(iex)), number of asynchrony events per minute and asynchrony index (AI) were determined. RESULTS: The study included 13 patients, six with COPD, and two with mixed pulmonary disease. T(d) was reduced with NAVA: median 35 ms (IQR 31-53 ms) versus 181 ms (122-208 ms); p = 0.0002. NAVA reduced both premature and delayed cyclings in the majority of patients, but not the median T(iex) value. The total number of asynchrony events tended to be reduced with NAVA: 1.0 events/min (0.5-3.1 events/min) versus 4.4 events/min (0.9-12.1 events/min); p = 0.08. AI was lower with NAVA: 4.9 % (2.5-10.5 %) versus 15.8 % (5.5-49.6 %); p = 0.03. During NAVA, there were no ineffective efforts, or late or premature cyclings. PaO(2) and PaCO(2) were not different between ventilatory modes. CONCLUSION: Compared to PS, NAVA improved patient ventilator synchrony during noninvasive ventilation by reducing T(d) and AI. Moreover, with NAVA, ineffective efforts, and late and premature cyclings were absent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION. The role of turbine-based NIV ventilators (TBV) versus ICU ventilators with NIV mode activated (ICUV) to deliver NIV in case of severe respiratory failure remains debated. OBJECTIVES. To compare the response time and pressurization capacity of TBV and ICUV during simulated NIV with normal and increased respiratory demand, in condition of normal and obstructive respiratory mechanics. METHODS. In a two-chamber lung model, a ventilator simulated normal (P0.1 = 2 mbar, respiratory rate RR = 15/min) or increased (P0.1 = 6 mbar, RR = 25/min) respiratory demand. NIV was simulated by connecting the lung model (compliance 100 ml/mbar; resistance 5 or 20 l/mbar) to a dummy head equipped with a naso-buccal mask. Connections allowed intentional leaks (29 ± 5 % of insufflated volume). Ventilators to test: Servo-i (Maquet), V60 and Vision (Philips Respironics) were connected via a standard circuit to the mask. Applied pressure support levels (PSL) were 7 mbar for normal and 14 mbar for increased demand. Airway pressure and flow were measured in the ventilator circuit and in the simulated airway. Ventilator performance was assessed by determining trigger delay (Td, ms), pressure time product at 300 ms (PTP300, mbar s) and inspiratory tidal volume (VT, ml) and compared by three-way ANOVA for the effect of inspiratory effort, resistance and the ventilator. Differences between ventilators for each condition were tested by oneway ANOVA and contrast (JMP 8.0.1, p\0.05). RESULTS. Inspiratory demand and resistance had a significant effect throughout all comparisons. Ventilator data figure in Table 1 (normal demand) and 2 (increased demand): (a) different from Servo-i, (b) different from V60.CONCLUSION. In this NIV bench study, with leaks, trigger delay was shorter for TBV with normal respiratory demand. By contrast, it was shorter for ICUV when respiratory demand was high. ICUV afforded better pressurization (PTP 300) with increased demand and PSL, particularly with increased resistance. TBV provided a higher inspiratory VT (i.e., downstream from the leaks) with normal demand, and a significantly (although minimally) lower VT with increased demand and PSL.